期刊文献+
共找到79,236篇文章
< 1 2 250 >
每页显示 20 50 100
Assessing the corrosion protection property of coatings loaded with corrosion inhibitors using the real-time atmospheric corrosion monitoring technique
1
作者 Xiaoxue Wang Lulu Jin +8 位作者 Jinke Wang Rongqiao Wang Xiuchun Liu Kai Gao Jingli Sun Yong Yuan Lingwei Ma Hongchang Qian Dawei Zhang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS 2025年第1期119-126,共8页
The atmospheric corrosion monitoring(ACM)technique has been widely employed to track the real-time corrosion behavior of metal materials.However,limited studies have applied ACM to the corrosion protection properties ... The atmospheric corrosion monitoring(ACM)technique has been widely employed to track the real-time corrosion behavior of metal materials.However,limited studies have applied ACM to the corrosion protection properties of organic coatings.This study compared a bare epoxy coating with one containing zinc phosphate corrosion inhibitors,both applied on ACM sensors,to observe their corrosion protection properties over time.Coatings with artificial damage via scratches were exposed to immersion and alternating dry and wet environments,which allowed for monitoring galvanic corrosion currents in real-time.Throughout the corrosion tests,the ACM currents of the zinc phosphate/epoxy coating were considerably lower than those of the blank epoxy coating.The trend in ACM current variations closely matched the results obtained from regular electrochemical tests and surface analysis.This alignment highlights the potential of the ACM technique in evaluating the corrosion protection capabilities of organic coatings.Compared with the blank epoxy coating,the zinc phosphate/epoxy coating showed much-decreased ACM current values that confirmed the effective inhibition of zinc phosphate against steel corrosion beneath the damaged coating. 展开更多
关键词 atmospheric corrosion monitoring technology corrosion inhibitor coatING carbon steel corrosion protection
下载PDF
High corrosion and wear resistant electroless Ni–P gradient coatings on aviation aluminum alloy parts 被引量:2
2
作者 Bo Wang Jiawei Li +2 位作者 Zhihui Xie Gengjie Wang Gang Yu 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CSCD 2024年第1期155-164,共10页
A Ni–P alloy gradient coating consisting of multiple electroless Ni–P layers with various phosphorus contents was prepared on the aviation aluminum alloy. Several characterization and electrochemical techniques were... A Ni–P alloy gradient coating consisting of multiple electroless Ni–P layers with various phosphorus contents was prepared on the aviation aluminum alloy. Several characterization and electrochemical techniques were used to characterize the different Ni–P coatings’ morphologies, phase structures, elemental compositions, and corrosion protection. The gradient coating showed good adhesion and high corrosion and wear resistance, enabling the application of aluminum alloy in harsh environments. The results showed that the double zinc immersion was vital in obtaining excellent adhesion (81.2 N). The optimal coating was not peeled and shredded even after bending tests with angles higher than 90°and was not corroded visually after 500 h of neutral salt spray test at 35℃. The high corrosion resistance was attributed to the misaligning of these micro defects in the three different nickel alloy layers and the amorphous structure of the high P content in the outer layer. These findings guide the exploration of functional gradient coatings that meet the high application requirement of aluminum alloy parts in complicated and harsh aviation environments. 展开更多
关键词 aluminum alloy ELECTROLESS nickel coating CORROSION ADHESION
下载PDF
Design multifunctional Mg–Zr coatings regulating Mg alloy bioabsorption 被引量:2
3
作者 Zohra Benzarti Sandesh Itani +2 位作者 JoséDavid Castro Sandra Carvalho Ana Sofia Ramos 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第4期1461-1478,共18页
Magnesium(Mg)alloys are widely used for temporary bone implants due to their favorable biodegradability,cytocompatibility,hemocompatibility,and close mechanical properties to bone.However,rapid degradation and inadequ... Magnesium(Mg)alloys are widely used for temporary bone implants due to their favorable biodegradability,cytocompatibility,hemocompatibility,and close mechanical properties to bone.However,rapid degradation and inadequate strength limit their applicability.To overcome this,the direct current magnetron sputtering technique is employed for surface coating in Mg-based alloys using various zirconium(Zr)content.This approach presents a promising strategy for simultaneously improving corrosion resistance,maintaining biocompatibility,and enhancing strength without compromising osseointegration.By leveraging Mg’s inherent biodegradability,it has the potential to minimize the need for secondary surgeries,thereby reducing costs and resources.This paper is a systematic study aimed at understanding the corrosion mechanisms of Mg–Zr coatings,denoted Mg-xZr(x=0–5 at.%).Zr-doped coatings exhibited columnar growth leading to denser and refined structures with increasing Zr content.XRD analysis confirmed the presence of the Mg(00.2)basal plane,shifting towards higher angles(1.15°)with 5 at.%Zr doping due to lattice parameter changes(i.e.,decrease and increase of“c”and“a”lattice parameters,respectively).Mg–Zr coatings exhibited“liquidphilic”behavior,while Young’s modulus retained a steady value around 80 GPa across all samples.However,the hardness has significantly improved across all samples’coating,reaching the highest value of(2.2±0.3)GPa for 5 at.%Zr.Electrochemical testing in simulated body fluid(SBF)at 37℃ revealed a significant enhancement in corrosion resistance for Mg–Zr coatings containing 1.0–3.4 at.%Zr.Compared with the 5 at.%Zr coating which exhibited a corrosion rate of 32 mm/year,these coatings displayed lower corrosion rates,ranging from 1 to 12 mm/year.This synergistic enhancement in mechanical properties and corrosion resistance,achieved with 2.0–3.4 at.%Zr,suggests potential ability for reducing stress shielding and controlled degradation performance,and consequently,promising functional biodegradable materials for temporary bone implants. 展开更多
关键词 Mg-Zr coatings Magnetron sputtering NANOINDENTATION Corrosion resistance Bone implants
下载PDF
High-grade pancreatic intraepithelial neoplasia diagnosed based on changes in magnetic resonance cholangiopancreatography findings:A case report 被引量:2
4
作者 Nao Furuya Atsushi Yamaguchi +13 位作者 Naohiro Kato Syuhei Sugata Takuro Hamada Takeshi Mizumoto Yuzuru Tamaru Ryusaku Kusunoki Toshio Kuwai Hirotaka Kouno Kazuya Kuraoka Yoshiyuki Shibata Sho Tazuma Takeshi Sudo Hiroshi Kohno Shiro Oka 《World Journal of Clinical Cases》 SCIE 2024年第8期1487-1496,共10页
BACKGROUND High-grade pancreatic intraepithelial neoplasia(PanIN)exhibits no mass and is not detected by any examination modalities.However,it can be diagnosed by pancreatic juice cytology from indirect findings.Most ... BACKGROUND High-grade pancreatic intraepithelial neoplasia(PanIN)exhibits no mass and is not detected by any examination modalities.However,it can be diagnosed by pancreatic juice cytology from indirect findings.Most previous cases were diagnosed based on findings of a focal stricture of the main pancreatic duct(MPD)and caudal MPD dilatation and subsequent pancreatic juice cytology using endoscopic retrograde cholangiopancreatography(ERCP).We experienced a case of high-grade PanIN with an unclear MPD over a 20-mm range,but without caudal MPD dilatation on magnetic resonance cholangiopancreatography(MRCP).CASE SUMMARY A 60-year-old female patient underwent computed tomography for a follow-up of uterine cancer post-excision,which revealed pancreatic cysts.MRCP revealed an unclear MPD of the pancreatic body at a 20-mm length without caudal MPD dilatation.Thus,course observation was performed.After 24 mo,MRCP revealed an increased caudal MPD caliber and a larger pancreatic cyst.We performed ERCP and detected atypical cells suspected of adenocarcinoma by serial pancreatic juice aspiration cytology examination.We performed a distal pancreatectomy and obtained a histopathological diagnosis of high-grade PanIN.Pancreatic parenchyma invasion was not observed,and curative resection was achieved.CONCLUSION High-grade Pan-IN may cause MPD narrowing in a long range without caudal MPD dilatation. 展开更多
关键词 Pancreatic cancer Pancreatic intraepithelial neoplasm high-grade pancreatic intraepithelial neoplasm Magnetic resonance cholangiopancreatography Carcinoma in situ Case report
下载PDF
Surface Metallization of Glass Fiber(GF)/Polyetheretherketone(PEEK) Composite with Cu Coatings Deposited by Magnetron Sputtering and Electroplating 被引量:1
5
作者 钟利 金凡亚 +2 位作者 朱剑豪 TONG Honghui DAN Min 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS CSCD 2024年第1期213-220,共8页
Surface metallization of glass fiber(GF)/polyetheretherketone(PEEK)[GF/PEEK] is conducted by coating copper using electroplating and magnetron sputtering and the properties are determined by X-ray diffraction(XRD), sc... Surface metallization of glass fiber(GF)/polyetheretherketone(PEEK)[GF/PEEK] is conducted by coating copper using electroplating and magnetron sputtering and the properties are determined by X-ray diffraction(XRD), scanning electron microscopy(SEM), and electron backscatter diffraction(EBSD).The coating bonding strength is assessed by pull-out tests and scribing in accordance with GB/T 9286-1998.The results show that the Cu coating with a thickness of 30 μm deposited on GF/PEEK by magnetron sputtering has lower roughness, finer grain size, higher crystallinity, as well as better macroscopic compressive stress,bonding strength, and electrical conductivity than the Cu coating deposited by electroplating. 展开更多
关键词 surface metallization Cu coating magnetron sputtering ELECTROPLATING
下载PDF
Bio-Based Waterborne Poly(Vanillin-Butyl Acrylate)/MXene Coatings for Leather with Desired Warmth Retention and Antibacterial Properties 被引量:1
6
作者 Jianzhong Ma Li Ma +3 位作者 Lei Zhang Wenbo Zhang Qianqian Fan Buxing Han 《Engineering》 SCIE EI CAS CSCD 2024年第5期250-263,共14页
This study presents a solvent-free,facile synthesis of a bio-based green antibacterial agent and aromatic monomer methacrylated vanillin(MV)using vanillin.The resulting MV not only imparted antibacterial properties to... This study presents a solvent-free,facile synthesis of a bio-based green antibacterial agent and aromatic monomer methacrylated vanillin(MV)using vanillin.The resulting MV not only imparted antibacterial properties to coatings layered on leather,but could also be employed as a green alternative to petroleum-based carcinogen styrene(St).Herein,MV was copolymerized with butyl acrylate(BA)to obtain waterborne bio-based P(MV-BA)miniemulsion via miniemulsion polymerization.Subsequently,MXene nanosheets with excellent photothermal conversion performance and antibacterial properties,were introduced into the P(MV-BA)miniemulsion by ultrasonic dispersion.During the gradual solidification of P(MV-BA)/MXene nanocomposite miniemulsion on the leather surface,MXene gradually migrated to the surface of leather coatings due to the cavitation effect of ultrasonication and amphiphilicity of MXene,which prompted its full exposure to light and bacteria,exerting the maximum photothermal conversion efficiency and significant antibacterial efficacy.In particular,when the dosage of MXene nanosheets was 1.4 wt%,the surface temperature of P(MV-BA)/MXene nanocomposite miniemulsioncoated leather(PML)increased by about 15℃ in an outdoor environment during winter,and the antibacterial rate against Escherichia coli and Staphylococcus aureus was nearly 100%under the simulated sunlight treatment for 30 min.Moreover,the introduction of MXene nanosheets increased the air permeability,water vapor permeability,and thermal stability of these coatings.This study provides a new insight into the preparation of novel,green,and waterborne bio-based nanocomposite coatings for leather,with desired warmth retention and antibacterial properties.It can not only realize zerocarbon heating based on sunlight in winter,reducing the use of fossil fuels and greenhouse gas emissions,but also improve ability to fight off invasion by harmful bacteria,viruses,and other microorganisms. 展开更多
关键词 MXene nanosheets VANILLIN Styrene substitute Leather coating Photothermal conversion Warmth retention Antibacterial properties
下载PDF
Bulk geochemistry,Rb-Sr,Sm-Nd,and stable O-H isotope systematics of the Metzimevin high-grade iron ore deposit,Mbalam iron ore district,southern Cameroon
7
作者 Samndong Cyril Tufoin Cheo Emmanuel Suh +1 位作者 Tabod Charles Tabod George Lemewihbwen Ngiamte 《Acta Geochimica》 EI CAS CSCD 2024年第4期677-706,共30页
Bulk geochemistry,Sr,Nd,and O-H isotope systematics are reported for the first time on banded iron formation(BIF)-hosted high-grade iron ore at the northwestern segment of Congo Craton(CC).Located in Mbalam iron ore d... Bulk geochemistry,Sr,Nd,and O-H isotope systematics are reported for the first time on banded iron formation(BIF)-hosted high-grade iron ore at the northwestern segment of Congo Craton(CC).Located in Mbalam iron ore district,Southern Cameroon,Metzimevin iron ore deposit is a hematite-magnetite BIF system,dominated by SiO_(2)+Fe_(2)O_(3)(97.1 to 99.84 wt%),with low concentrations of clastic elements e.g.,Al_(2)O_(3),TiO_(2),and HFSE,depicting a nearly pure chemical precipitate.The REE+Y signature of the iron deposit displays strong positive Eu anomaly,strong negative Ce anomaly,and chondritic to superchondritic Y/Ho ratios,suggestive of formation by mixed seawater-high temperature hydrothermal fluids in oxidising environment.The^(87)Sr/^(86)Sr ratios of the BIF are higher than the maximum^(87)Sr/^(86)Sr evolution curves for all Archean reservoirs(bulk silicate earth,Archean crust and Archean seawater),indicating involvement of continentally-derived components during BIF formation and alteration.TheƐ_(Nd)(t)(+2.26 to+3.77)and Nd model age indicate that chemical constituents for the BIF were derived from undifferentiated crustal source,between 3.002 and 2.88 Ga.The variable and diverse O and H isotope data(−1.9‰to 17.3‰and−57‰to 136‰respectively)indicate that the Metzimevin iron ore formed initially from magmatic plumes and later enriched by magmatic-metamorphic-modified meteoric fluids.Mass balance calculations indicate mineralisation by combined leaching and precipitation,with an average iron enrichment factor of>2.67 and SiO_(2)depletion factor of>0.99.This is associated with an overall volume reduction of 28.27%,reflecting net leaching and volume collapse of the BIF protholith. 展开更多
关键词 Bulk geochemistry RB-SR SM-ND Mitzimevin high-grade iron ore
下载PDF
Developing an atmospheric aging evaluation model of acrylic coatings:A semi-supervised machine learning algorithm
8
作者 Yiran Li Zhongheng Fu +5 位作者 Xiangyang Yu Zhihui Jin Haiyan Gong Lingwei Ma Xiaogang Li Dawei Zhang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第7期1617-1627,共11页
To study the atmospheric aging of acrylic coatings,a two-year aging exposure experiment was conducted in 13 representative climatic environments in China.An atmospheric aging evaluation model of acrylic coatings was d... To study the atmospheric aging of acrylic coatings,a two-year aging exposure experiment was conducted in 13 representative climatic environments in China.An atmospheric aging evaluation model of acrylic coatings was developed based on aging data including11 environmental factors from 567 cities.A hybrid method of random forest and Spearman correlation analysis was used to reduce the redundancy and multicollinearity of the data set by dimensionality reduction.A semi-supervised collaborative trained regression model was developed with the environmental factors as input and the low-frequency impedance modulus values of the electrochemical impedance spectra of acrylic coatings in 3.5wt%NaCl solution as output.The model improves accuracy compared to supervised learning algorithms model(support vector machines model).The model provides a new method for the rapid evaluation of the aging performance of acrylic coatings,and may also serve as a reference to evaluate the aging performance of other organic coatings. 展开更多
关键词 acrylic coatings coatings aging atmospheric environment machine learning
下载PDF
Management of retroperitoneal high-grade serous carcinoma of unknown origin:A case report
9
作者 Wen-Lin Hsieh Dah-Ching Ding 《World Journal of Clinical Cases》 SCIE 2024年第6期1190-1195,共6页
BACKGROUND Retroperitoneal high-grade serous carcinoma(HGSC)of unknown origin is a sporadic tumor that can originate from ovarian cancer.Herein,we report the case of a woman with retroperitoneal HGSC of unknown origin... BACKGROUND Retroperitoneal high-grade serous carcinoma(HGSC)of unknown origin is a sporadic tumor that can originate from ovarian cancer.Herein,we report the case of a woman with retroperitoneal HGSC of unknown origin and describe how she was diagnosed and treated.CASE SUMMARY A 71-year-old female presented with the tumor marker CA125 elevated to 1041.9 U/mL upon a regular health examination.Computed tomography revealed retroperitoneal lymph node enlargement.Subsequently,positron emission tomography scanning revealed lesions with increased F-18 fluorodeoxyglucose uptake at the nodes.As a result,she underwent laparoscopic lymph node resection,and pathology revealed metastatic adenocarcinoma with CK7(+),PAX8(+),WT1(+),PR(-),and p53 mutational loss of expression,indicating that the origin may be from the adnexa.The patient was admitted to our ward and underwent laparoscopic staging;however,the pathological results were negative.Under the suspicion of retroperitoneal HGSC of unknown origin,chemotherapy and targeted therapy were initiated.Tumor marker levels decreased after treatment.CONCLUSION We present a case of HGSC of unknown origin managed using retroperitoneal lymphadenectomy,staging surgery,chemotherapy,and targeted therapy. 展开更多
关键词 high-grade serous carcinoma RETROPERITONEUM ORIGIN CHEMOTHERAPY Lymph node Case report
下载PDF
Multiscale Simulation of Microstructure Evolution during Preparation and Service Processes of Physical Vapor Deposited c-TiAlN Coatings
10
作者 Yehao Long Jing Zhong +2 位作者 Tongdi Zhang Li Chen Lijun Zhang 《Computers, Materials & Continua》 SCIE EI 2024年第6期3435-3453,共19页
Physical Vapor Deposited(PVD)TiAlN coatings are extensively utilized as protective layers for cutting tools,renowned for their excellent comprehensive performance.To optimize quality control of TiAlN coatings for cutt... Physical Vapor Deposited(PVD)TiAlN coatings are extensively utilized as protective layers for cutting tools,renowned for their excellent comprehensive performance.To optimize quality control of TiAlN coatings for cutting tools,a multi-scale simulation approach is proposed that encompasses the microstructure evolution of coatings considering the entire preparation and service lifecycle of PVD TiAlN coatings.This scheme employs phase-field simulation to capture the essential microstructure of the PVD-prepared TiAlN coatings.Moreover,cutting simulation is used to determine the service temperature experienced during cutting processes at varying rates.Cahn-Hilliard modeling is finally utilized to consume the microstructure and service condition data to acquaint the microstructure evolution of TiAlN coatings throughout the cutting processes.This methodology effectively establishes a correlation between service temperature and its impact on the microstructure evolution of TiAlN coatings.It is expected that the present multi-scale numerical simulation approach will provide innovative strategies for assisting property design and lifespan prediction of TiAlN coatings. 展开更多
关键词 Multiscale PHASE-FIELD TiAlN coatings PVD CUTTING
下载PDF
Characteristics and risk factor analyses of high-grade intraepithelial neoplasia in older patients with colorectal polyps
11
作者 Xin Zhang Ying Wang +2 位作者 Tong Zhu Jian Ge Jun-Hua Yuan 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第10期4129-4137,共9页
BACKGROUND According to the degree of intradermal neoplasia in the colorectal exhalation,it can be divided into two grades:Low-grade intraepithelial neoplasia(LGIN)and high-grade intraepithelial neoplasia(HGIN).Curren... BACKGROUND According to the degree of intradermal neoplasia in the colorectal exhalation,it can be divided into two grades:Low-grade intraepithelial neoplasia(LGIN)and high-grade intraepithelial neoplasia(HGIN).Currently,it is difficult to accurately diagnose LGIN and HGIN through imaging,and clinical diagnosis depends on postoperative histopathological diagnosis.A more accurate method for evaluating HGIN preoperatively is urgently needed in the surgical treatment and nursing intervention of colorectal polyps.AIM To explore the characteristics and risk factors of HGIN in older patients with colorectal polyps.METHODS We selected 84 older patients diagnosed with HGIN as the HGIN group(n=95 colonic polyps)and 112 older patients diagnosed with LGIN as the LGIN group(n=132 colonic polyps)from Shandong Provincial Hospital Affiliated to Shandong First Medical University.The endoscopic features,demographic characteristics,and clinical manifestations of the two patient groups were compared,and a logistic regression model was used to analyze the risk factors for HGIN in these patients.RESULTS The HGIN group was older and had a higher number of sigmoid colon polyps,rectal polyps,pedunculated polyps,polyps≥1.0 cm in size,polyps with surface congestion,polyps with surface depression,and polyps with villous/tubular adenomas,a higher proportion of patients with diabetes and a family history of colorectal cancer,patients who experienced rectal bleeding or occult blood,patients with elevated carcinoembryonic antigen(CEA)and cancer antigen 199(CA199),and lower nutritional levels and higher frailty levels.The polyp location(in the sigmoid colon or rectum),polyp diameter(≥1.0 cm),pathological diagnosis of(villous/tubular adenoma),family history of colorectal cancer,rectal bleeding or occult blood,elevated serum CEA and CA199 levels,lower nutritional levels and higher frailty levels also are independent risk factors for HGIN.CONCLUSION The occurrence of high-grade neoplastic transformation in colorectal polyps is closely associated with their location,size,villous/tubular characteristics,family history,elevated levels of tumor markers,and lower nutritional levels and higher frailty levels. 展开更多
关键词 ELDERLY Colorectal polyps high-grade intraepithelial neoplasia Low-grade intraepithelial neoplasia Risk factors
下载PDF
High-grade serous carcinoma of the fallopian tube in a young woman with chromosomal 4q abnormality:A case report
12
作者 Kai-Cheng Zhang Shao-Yin Chu Dah-Ching Ding 《World Journal of Clinical Cases》 SCIE 2024年第18期3539-3547,共9页
BACKGROUND Few studies have reported an association between an increased risk of acquiring cancers and survival in patients with 4q deletion syndrome.This study presents a rare association between chromosome 4q abnorm... BACKGROUND Few studies have reported an association between an increased risk of acquiring cancers and survival in patients with 4q deletion syndrome.This study presents a rare association between chromosome 4q abnormalities and fallopian tube highgrade serous carcinoma(HGSC)in a young woman.CASE SUMMARY A 35-year-old woman presented with acute dull abdominal pain and a known chromosomal abnormality involving 4q13.3 duplication and 4q23q24 deletion.Upon arrival at the emergency room,her abdomen appeared ovoid and distended with palpable shifting dullness.Ascites were identified through abdominal ultrasound,and computed tomography revealed an omentum cake and an enlarged bilateral adnexa.Blood tests showed elevated CA-125 levels.Paracentesis was conducted,and immunohistochemistry indicated that the cancer cells favored an ovarian origin,making us suspect ovarian cancer.The patient underwent debulking surgery,which led to a diagnosis of stage IIIC HGSC of the fallopian tube.Subsequently,the patient received adjuvant chemotherapy with carboplatin and paclitaxel,resulting in stable current condition.CONCLUSION This study demonstrates a rare correlation between a chromosome 4q abnormality and HGSC.UBE2D3 may affect crucial cancer-related pathways,including P53,BRCA,cyclin D,and tyrosine kinase receptors,thereby possibly contributing to cancer development.In addition,ADH1 and DDIT4 may be potential influencers of both carcinogenic and therapeutic responses. 展开更多
关键词 high-grade serous carcinoma Fallopian tube Young age Chromosomal abnormality Mental retardation AGING Case report
下载PDF
Degradation and biocompatibility of one-step electrodeposited magnesium thioctic acid/magnesium hydroxide hybrid coatings on ZE21B alloys for cardiovascular stents
13
作者 Zhao-Qi Zhang Bing-Zhi Li +5 位作者 Pei-Duo Tong Shao-Kang Guan Li Wang Zheng-Hui Qiu Cun-Guo Lin Rong-Chang Zeng 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第1期120-138,共19页
Constructing a functional hybrid coating appears to be a promising strategy for addressing the poor corrosion resistance and insufficient endothelialization of Mg-based stents.Nevertheless,the steps for preparing comp... Constructing a functional hybrid coating appears to be a promising strategy for addressing the poor corrosion resistance and insufficient endothelialization of Mg-based stents.Nevertheless,the steps for preparing composite coatings are usually complicated and time-consuming.Herein,a novel composite coating,composed of bioactive magnesium thioctic acid(MTA)layer formed by deposition and corrosion-resistant magnesium hydroxide(Mg(OH)_(2))layer grown in situ,is simply fabricated on ZE21B alloys via one-step electrodeposition.Scanning electron microscopy(SEM)shows that the electrodeposited coating has a compact and uniform structure.And the high adhesion of the MTA/Mg(OH)_(2)hybrid coating is also confirmed by the micro-scratch test.Electrochemical test,scanning kelvin probe(SKP),and hydrogen evolution measurement indicate that the hybrid coating effectively reduces the degradation rate of Mg substrates.Haemocompatibility experiment and cell culture trial detect that the composite coating is of fine biocompatibility.Finally,the preparation mechanism of MTA/Mg(OH)_(2)hybrid coatings is discussed and proposed.This coating shows a great potential application for cardiovascular stents. 展开更多
关键词 Magnesium alloy Corrosion resistance Hybrid coating ENDOTHELIALIZATION BIOCOMPATIBILITY
下载PDF
HVOF-sprayed HAp/S53P4 BG composite coatings on an AZ31 alloy for potential applications in temporary implants
14
作者 Carlos A.Poblano-Salas John Henao +6 位作者 Astrid L.Giraldo-Betancur Paola Forero-Sossa Diego German Espinosa-Arbelaez Jorge A.González-Sánchez Luis R.Dzib-Pérez Susana T.Estrada-Moo Idelfonso E.Pech-Pech 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第1期345-360,共16页
Bioactive thermal spray coatings produced via high-velocity oxygen fuel spray(HVOF)from hydroxyapatite(HAp)and bioactive glasses(BG)have the potential to be employed on temporary implants due to the ability of both HA... Bioactive thermal spray coatings produced via high-velocity oxygen fuel spray(HVOF)from hydroxyapatite(HAp)and bioactive glasses(BG)have the potential to be employed on temporary implants due to the ability of both HAp and BG to dissolve and promote osseointegration,considering that both phases have different reaction and dissolution rates under in-vitro conditions.In the present work,75%wt.HAp-25%wt.S53P4 bioactive glass powders were HVOF-sprayed to obtain HAp/S53P4 BG composite coatings on a bioresorbable AZ31 alloy.The study is focused on exploring the effect of the stand-off distance and fuel/oxygen ratio variation as HVOF parameters to obtain stable structural coatings and to establish their effect on the phases and microstructure produced in those coatings.Different characterization techniques,such as scanning electron microscopy,X-ray diffraction,and Fourier transform infrared spectroscopy,were employed to characterize relevant structural and microstructural properties of the composite coatings.The results showed that thermal gradients during coating deposition must be managed to avoid delamination due to the high temperature achieved(max 550℃)and the differences in coefficients of thermal expansion.It was also found that both spraying distance and oxygen/fuel ratio allowed to keep the hydroxyapatite as the main phase in the coatings.In addition,in-vitro electrochemical studies were performed on the obtained HAp/S53P4 BG composite coatings and compared against the uncoated AZ31 alloy.The results showed a significant decrease in hydrogen evolution(at least 98%)when the bioactive coating was applied on the Mg alloy during evaluation in simulated body fluid(SBF). 展开更多
关键词 coatings Composites Thermal spray Temporary implants Hydrogen evolution
下载PDF
Transformation of marginal zone lymphoma into high-grade B-cell lymphoma expressing terminal deoxynucleotidyl transferase:A case report
15
作者 Zhi-Min Fan Dao-Lei Wu +4 位作者 Neng-Wen Xu Li Ye Li-Ping Yan Lin-Jie Li Jun-Yu Zhang 《World Journal of Clinical Cases》 SCIE 2024年第15期2655-2663,共9页
BACKGROUND High-grade B-cell lymphoma(HGBL)is an unusual malignancy that includes myelocytomatosis viral oncogene(MYC),B-cell lymphoma-2(BCL-2),and/or BCL-6 rearrangements,termed double-hit or triple-hit lymphomas,and... BACKGROUND High-grade B-cell lymphoma(HGBL)is an unusual malignancy that includes myelocytomatosis viral oncogene(MYC),B-cell lymphoma-2(BCL-2),and/or BCL-6 rearrangements,termed double-hit or triple-hit lymphomas,and HGBL-not otherwise specific(HGBL-NOS),which are morphologically characteristic of HGBL but lack MYC,BCL-2,or BCL-6 rearrangements.HGBL is partially transformed by follicular lymphoma and other indolent lymphoma,with few cases of marginal zone lymphoma(MZL)transformation.HGBL often has a poor prognosis and intensive therapy is currently mainly advocated,but there is no good treatment for these patients who cannot tolerate chemotherapy.CASE SUMMARY We reported a case of MZL transformed into HGBL-NOS with TP53 mutation and terminal deoxynucleotidyl transferase expression.Gene analysis revealed the gene expression profile was identical in the pre-and post-transformed tissues,suggesting that the two diseases are homologous,not secondary tumors.The chemotherapy was ineffective and the side effect was severe,so we tried combination therapy including venetoclax and obinutuzumab.The patient tolerated treatment well,and reached partial response.The patient had recurrence of hepatocellular carcinoma and died of multifunctional organ failure.He survived for 12 months after diagnosis.CONCLUSION Venetoclax combined with obinutuzumab might improve the survival in some HGBL patients,who are unsuitable for chemotherapy. 展开更多
关键词 Marginal zone lymphoma high-grade B-cell lymphoma Terminal deoxynucleotidyl transferase Venetoclax TP53 mutation Case report
下载PDF
Antibacterial HA-coatings on bioresorbable Mg alloy
16
作者 K.V.Nadaraia D.V.Mashtalyar +13 位作者 M.A.Piatkova A.I.Pleshkova I.M.Imshinetskiy M.S.Gerasimenko E.A.Belov V.V.Kumeiko D.N.Kozyrev K.A.Fomenko V.V.Mostovaya B.R.Torpanov A.R.Biktimirov I.S.Osmushko S.L.Sinebryukhov S.V.Gnedenkov 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第5期1965-1985,共21页
In this study,a calcium-phosphate coating was formed on a Mg-Mn-Ce alloy by the plasma electrolytic oxidation(PEO).The antibiotic vancomycin,widely used in the treatment of infections caused by Staphylococcus aureus(S... In this study,a calcium-phosphate coating was formed on a Mg-Mn-Ce alloy by the plasma electrolytic oxidation(PEO).The antibiotic vancomycin,widely used in the treatment of infections caused by Staphylococcus aureus(S.aureus),was impregnated into the coating.Samples with vancomycin showed high bactericidal activity against S.aureus.The mechanical and electrochemical properties of the formed coatings were studied,as well as in vitro cytotoxicity tests and in vivo tests on mature male rats were performed.According to SEM,EDS,XRD and XPS data,coatings had a developed morphology and contained hydroxyapatite,which indicates high biocompatibility.The analysis of roughness of coatings without and with vancomycin did not reveal any differences,confirming the high roughness of the samples.During electrochemical tests,an increase in corrosion resistance by more than two times after the application of PEO coatings was revealed.According to the results of an in vivo study,after 28 days of the implantation of samples with calcium phosphate PEO coating and vancomycin,no signs of inflammation were observed,while an inflammatory reaction developed in the area of implantation of bare alloy,followed by encapsulation.Antibiotic release tests from the coatings show a sharp decrease in the concentration of the released antibiotic on day 7 and then a gradual decrease until day 28.Throughout the experiment,no significant deviations in the condition and behavior of the animals were observed;clinical tests did not reveal a systemic toxic reaction. 展开更多
关键词 Bioactive coatings BIOCOMPATIBILITY Mg alloy Plasma electrolytic oxidation Hydroxyapatite VANCOMYCIN
下载PDF
Structure and corrosion behavior of FeCoCrNiMo high-entropy alloy coatings prepared by mechanical alloying and plasma spraying
17
作者 Yun Tian Jianing Liu +5 位作者 Mingming Xue Dongyao Zhang Yuxin Wang Keping Geng Yanchun Dong Yong Yang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第12期2692-2705,共14页
FeCoCrNiMox composite powders were prepared using the mechanical alloying technique and made into high-entropy alloy(HEA)coatings with the face-centered cubic phase using plasma spraying to address the element segrega... FeCoCrNiMox composite powders were prepared using the mechanical alloying technique and made into high-entropy alloy(HEA)coatings with the face-centered cubic phase using plasma spraying to address the element segregation problem in HEAs and pre-pare uniform HEA coatings.Scanning electron microscopy,transmission electron microscopy,and X-ray diffractometry were employed to characterize these coatings’microstructure and phase composition.The hardness,elastic modulus,and fracture toughness of coatings were tested,and the corrosion resistance was analyzed in simulated seawater.Results show that the hardness of the coating is HV0.1606.15,the modulus of elasticity is 128.42 GPa,and the fracture toughness is 43.98 MPa·m^(1/2).The corrosion potential of the coating in 3.5wt%NaCl solution is-0.49 V,and the corrosion current density is 1.2×10^(−6)A/cm^(2).The electrochemical system comprises three parts:the electrolyte,the adsorption and metallic oxide films produced during immersion,and the FeCoNiCrMo HEA coating.Over in-creasingly long periods,the corrosion reaction rate increases first and then decreases,the corrosion product film comprising metal oxides reaches a dynamic balance between formation and dissolution,and the internal reaction of the coating declines. 展开更多
关键词 high-entropy alloy coatings plasma spray mechanical alloying microstructure corrosion behavior mechanical property
下载PDF
Optical facet coatings for high-performance LWIR quantum cascade lasers atλ∼8.5μm
18
作者 MA Yuan LIN Yu-Zhe +5 位作者 WAN Chen-Yang WANG Zi-Xian ZHOU Xu-Yan ZHANG Jin-Chuan LIU Feng-Qi ZHENG Wan-Hua 《红外与毫米波学报》 SCIE EI CAS CSCD 北大核心 2024年第4期497-502,共6页
We report on the performance improvement of long-wave infrared quantum cascade lasers(LWIR QCLs)by studying and optimizing the anti-reflection(AR)optical facet coating.Compared to the Al2O3 AR coat⁃ing,the Y_(2)O_(3)A... We report on the performance improvement of long-wave infrared quantum cascade lasers(LWIR QCLs)by studying and optimizing the anti-reflection(AR)optical facet coating.Compared to the Al2O3 AR coat⁃ing,the Y_(2)O_(3)AR coating exhibits higher catastrophic optical mirror damage(COMD)level,and the optical facet coatings of both material systems have no beam steering effect.A 3-mm-long,9.5-μm-wide buried-heterostruc⁃ture(BH)LWIR QCL ofλ~8.5μm with Y_(2)O_(3)metallic high-reflection(HR)and AR of~0.2%reflectivity coating demonstrates a maximum pulsed peak power of 2.19 W at 298 K,which is 149%higher than that of the uncoated device.For continuous-wave(CW)operation,by optimizing the reflectivity of the Y_(2)O_(3)AR coating,the maximum output power reaches 0.73 W,which is 91%higher than that of the uncoated device. 展开更多
关键词 quantum cascade lasers long-wave infrared optical facet coatings catastrophic optical mirror damage
下载PDF
Ti3C2Tx MXene-functionalized Hydroxyapatite/Halloysite nanotube filled poly-(lactic acid)coatings on magnesium:In vitro and antibacterial applications
19
作者 Mehmet Topuz Yuksel Akinay +1 位作者 Erkan Karatas Tayfun Cetin 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第9期3758-3771,共14页
Magnesium(Mg)stands out in temporary biomaterial applications due to its biocompatibility,biodegradability,and low Young’s modulus.However,controlling its corrosion through next-generation polymer-based functional co... Magnesium(Mg)stands out in temporary biomaterial applications due to its biocompatibility,biodegradability,and low Young’s modulus.However,controlling its corrosion through next-generation polymer-based functional coatings is crucial due to the rapid degradation behavior of Mg.In this study,the function of 2D lamellar Ti_(3)C_(2)T_(x)(MXene)in Hydroxyapatite(HA)and Halloysite nanotube(HNT)hybrid coatings in biodegradable poly-(lactic acid)(PLA)was investigated.The morphological and structural characterizations of the coatings on Mg were revealed through HRTEM,XPS,SEM-EDX,XRD,FTIR,and contact angle analyses/tests.Electrochemical in vitro corrosion tests(OCP,PDS,and EIS-Nyquist)were conducted for evaluate corrosion resistance under simulated body fluid(SBF)conditions.The bioactivity of the coatings in SBF have been revealed in accordance with the ISO 23,317 standard.Finally,antibacterial disk diffusion tests were conducted to investigate the functional effect of MXene in coatings.It has been determined that the presence of MXene in the coating increased not only surface wettability(131°,85°,77°,and 74°for uncoated,pH,PHH,and PHH/MXene coatings,respectively)but also increased corrosion resistance(1857.850,42.357,1.593,and 0.085×10^(-6),A/cm^(2) for uncoated,pH,PHH,and PHH/MXene coatings,respectively).It has been proven that the in vitro bioactivity of PLA-HA coatings is further enhanced by adding HNT and MXene,along with SEM morphologies after SBF.Finally,2D lamellar MXene-filled coating exhibits antibacterial behavior against both E.coli and S.aureus bacteria. 展开更多
关键词 MAGNESIUM Pla coating Ti3c2tx mxene In-vitro bioactivity Disk diffusion
下载PDF
Effects of plasma spraying process on microstructure and mechanical properties of Cr_(2)AlC/410 composite coatings
20
作者 Yihu Ma Chaosheng Ma +1 位作者 Guozheng Ma Wenbo Yu 《High-Speed Railway》 2024年第2期110-115,共6页
To investigate the influences of Cr_(2)AlC mass fraction and supersonic plasma spraying process on the microstructure and mechanical properties of Cr_(2)AlC reinforced 410 stainless steel composite coatings,the coatin... To investigate the influences of Cr_(2)AlC mass fraction and supersonic plasma spraying process on the microstructure and mechanical properties of Cr_(2)AlC reinforced 410 stainless steel composite coatings,the coatings containing different mass fractions of Cr_(2)AlC were prepared and investigated.The composite coating exhibited low porosity and high adhesion strength.The addition of Cr_(2)AlC significantly enhanced the hardness of the composite coatings through particle strengthening.However,when the mass fraction of Cr_(2)AlC was 20%,the aggregation of Cr_(2)AlC resulted in a strong decrease in the coating preparation efficiency,as well as a decline in adhesion strength.In the supersonic plasma spraying process,the Ar flow rate mainly influenced the flight velocity of the particles,while the H_(2) flow rate and the current mainly affected the temperature of the plasma torch.Consequently,all of them influenced the melting degree of particles and the quality of the coating.The lowest porosity and the highest hardness and adhesion strength could be obtained when the Ar flow rate is 125 L/min,the H_(2) flow rate is 25 L/min,and the current is 385 A. 展开更多
关键词 MAX phase Plasma spray PARAMETER coating
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部