期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Transient Stability Assessment of Synchronous Generator in Power System with High-Penetration Photovoltaics 被引量:2
1
作者 Masaki Yagami Takahiko Hasegawa Junji Tamura 《Journal of Mechanics Engineering and Automation》 2012年第12期762-768,共7页
As photovoltaic (PV) capacity in power system increases, the capacity of synchronous generator needs to be reduced relatively. This leads to the lower system inertia and the higher generator reactance, and hence the... As photovoltaic (PV) capacity in power system increases, the capacity of synchronous generator needs to be reduced relatively. This leads to the lower system inertia and the higher generator reactance, and hence the generator transient stability may negatively be affected. In particular, the impact on the transient stability may become more serious when the considerable amounts of PV systems are disconnected simultaneously during voltage sag. In this work, the generator transient stability in the power system with significant PV penetration is assessed by a numerical simulation. In order to assess the impact from various angles, simulation parameters such as levels of PV penetration, variety of power sources (inverter or rotational machine), and existence of LVRT capability are considered. The simulation is performed by using PSCAD/EMTDC software. 展开更多
关键词 high-penetration photovoltaics low-voltage ride-through (LVRT) synchronous generator transient stability.
下载PDF
Transient Stability Assessment of Synchronous Generator in Power System with High-Penetration Photovoltaics (Part 2)
2
作者 Masaki Yagami Seiichiro lshikawa +2 位作者 Yoshihiro Ichinohe Kenji Misawa Junji Tamura 《Journal of Mechanics Engineering and Automation》 2015年第7期401-406,共6页
In the previous paper [1], the transient stability of synchronous generator in power system with high-penetration PV (photovoltaic) was assessed by simulation analysis of a single-machine infinite-bus system model. ... In the previous paper [1], the transient stability of synchronous generator in power system with high-penetration PV (photovoltaic) was assessed by simulation analysis of a single-machine infinite-bus system model. Through the simulation analysis, we have obtained some conclusions in terms of the impact of high-penetration PV on the stability. However, for more accurate assessment of the transient stability, it is necessary to analyze various simulation models considering many other power system conditions. This paper presents the results of the analysis for the transient stability simulation performed for IEEE 9-bus system model, in which the effects of various conditions, such as variety of power sources (inverter or rotational machine), load characteristics, existence of LVRT (low-voltage ride-through) capability and fault locations, on the transient stability are investigated. 展开更多
关键词 high-penetration photovoltaics LVRT (low-voltage ride-through) synchronous generator transient stability
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部