The Gaoloushan Tunnel in Longnan City,Gansu Province,China,frequently experiences rockburst disasters due to high in-situ stress.Managing rockburst in deep-buried tunnels remains a challenging issue.This paper employs...The Gaoloushan Tunnel in Longnan City,Gansu Province,China,frequently experiences rockburst disasters due to high in-situ stress.Managing rockburst in deep-buried tunnels remains a challenging issue.This paper employs RFPA(Rock Failure Process Analysis)software to establish a calculation model of constant resistance and large deformation(CRLD)anchorages and analyzes the effects of different support methods and pre-stress levels on rockburst.We simulate the process of tunnel rockburst disasters and find that ordinary anchor support incurs rockburst on the right arch waist and arch top,forming a V-shaped explosion pit.CRLD anchor support has several advantages in rockburst control,such as more uniform stress distribution in the surrounding rock,a uniform distribution of plastic zones,less noticeable damage to the tunnel,and effective control of the arch top displacement.The effectiveness of the CRLD anchor support under varying pre-stress conditions shows that a higher prestress results in a smaller plastic zone of the surrounding rock and arch top displacement and a lower number of acoustic emission signals,which better explains the excavation compensation effect.Moreover,adding long anchorages in the deep surrounding rock area can better control rockburst and reduce surrounding rock deformation.Based on these findings,we propose a comprehensive control system that combines long and short anchorages and provides the optimal scheme based on calculations.Therefore,by using high-prestress CRLD anchor support and the combination of long and short anchorages at critical positions,we can enhance the integrity of the surrounding rock,effectively absorb the energy released by the surrounding rock deformation,and reduce the incidence of rockburst disasters.展开更多
To calculate the flow resistance of a main cable dehumidification system,this study considers the air flow in the main cable as the flow in a porous medium,and adopts the Hagen–Poiseuille equation by using average hy...To calculate the flow resistance of a main cable dehumidification system,this study considers the air flow in the main cable as the flow in a porous medium,and adopts the Hagen–Poiseuille equation by using average hydraulic radius and capillary bundle models.A mathematical derivation is combined with an experimental study to obtain a semi-empirical flow resistance formula.Additionally,Fluent software is used to simulate the flow resistance across the main cable relative to the experimental values.Based on the actual measured results for a Yangtze River bridge,this study verifies the semi-empirical formula,and indicates that it can be applied in actual engineering.展开更多
In an integrated structure low resistance CICC joint, current is conducted by outer cable strands coming into touch with the conductive Cu sole. So it is an important condition for satisfying joint performance that ea...In an integrated structure low resistance CICC joint, current is conducted by outer cable strands coming into touch with the conductive Cu sole. So it is an important condition for satisfying joint performance that each strand of the cable inside the joint is able to come to the outermost by transposition. This paper presents analysis, calculation and figures for the strand transposition. According to the twist procedures of the superconducting cable, the author computed the actual pitch of each stage cable, consecutively computed the projection of each stage cable on the axis of the cable (z axis) and the corresponding twist angle as the z coordinate changes, which is then drawn by AutoCAD. From the results shown in the figures, the minimal cable length, which enables each strand to transpose almost equally to the outermost of the cable in such a length, call be determined as the optimal joint length.展开更多
A new method is developed for removing the nickel coating on ITER superconducting cables by mechanical polishing.The obvious advantage of the mechanical method,which uses a nylon brush,is that there is no chemical res...A new method is developed for removing the nickel coating on ITER superconducting cables by mechanical polishing.The obvious advantage of the mechanical method,which uses a nylon brush,is that there is no chemical residual left in the cable,which would otherwise result in passive effects on the joint resistance.The coating resistance test results of this newly developed method are compared with those of the two other methods that can meet the requirements of ITER.An automatic polishing machine is designed and manufactured for the procedure to provide quality under precise control.This new technique can replace the conventional manual method due to its improved efficiency.展开更多
Considering the insulators ageing in a mixture of PVC and dye, set following operating conditions and time to ensure proper operation and perfect safety of industrial installations using insulated conductors. The resu...Considering the insulators ageing in a mixture of PVC and dye, set following operating conditions and time to ensure proper operation and perfect safety of industrial installations using insulated conductors. The results showed that the insulation carried out by the L.C main office was a good quality (on thermal aspect), because the resistance of the insulation is so high (i.e. 3940 Mega Ohms under normal conditions). The results showed a lifespan of 50 years at a temperature of 40°C (close to ambient temperature), plus minus 33 years at a temperature of 70°C;plus minus 22 years at a temperature of 100°C and 12 years at a temperature of 160°C. Furthermore, information on chemical attack, the results showed that PVC cables have poor resistance to sulfuric acid attack (having a pH of 1.5 and a density of 1.84 g/cm<sup>3</sup>). LC/Gecamines is able to produce locally a good quality of electrical cables.展开更多
基金funded by the National Natural Science Foundation of China(52174096,42277174)the Fundamental Research Funds for the Central Universities(2022YJSSB03)the Scientific and Technological Projects of Henan Province(232102320238)。
文摘The Gaoloushan Tunnel in Longnan City,Gansu Province,China,frequently experiences rockburst disasters due to high in-situ stress.Managing rockburst in deep-buried tunnels remains a challenging issue.This paper employs RFPA(Rock Failure Process Analysis)software to establish a calculation model of constant resistance and large deformation(CRLD)anchorages and analyzes the effects of different support methods and pre-stress levels on rockburst.We simulate the process of tunnel rockburst disasters and find that ordinary anchor support incurs rockburst on the right arch waist and arch top,forming a V-shaped explosion pit.CRLD anchor support has several advantages in rockburst control,such as more uniform stress distribution in the surrounding rock,a uniform distribution of plastic zones,less noticeable damage to the tunnel,and effective control of the arch top displacement.The effectiveness of the CRLD anchor support under varying pre-stress conditions shows that a higher prestress results in a smaller plastic zone of the surrounding rock and arch top displacement and a lower number of acoustic emission signals,which better explains the excavation compensation effect.Moreover,adding long anchorages in the deep surrounding rock area can better control rockburst and reduce surrounding rock deformation.Based on these findings,we propose a comprehensive control system that combines long and short anchorages and provides the optimal scheme based on calculations.Therefore,by using high-prestress CRLD anchor support and the combination of long and short anchorages at critical positions,we can enhance the integrity of the surrounding rock,effectively absorb the energy released by the surrounding rock deformation,and reduce the incidence of rockburst disasters.
基金Ministry of Communications and Provincial and Joint Research Project[2008-353-332-170].
文摘To calculate the flow resistance of a main cable dehumidification system,this study considers the air flow in the main cable as the flow in a porous medium,and adopts the Hagen–Poiseuille equation by using average hydraulic radius and capillary bundle models.A mathematical derivation is combined with an experimental study to obtain a semi-empirical flow resistance formula.Additionally,Fluent software is used to simulate the flow resistance across the main cable relative to the experimental values.Based on the actual measured results for a Yangtze River bridge,this study verifies the semi-empirical formula,and indicates that it can be applied in actual engineering.
文摘In an integrated structure low resistance CICC joint, current is conducted by outer cable strands coming into touch with the conductive Cu sole. So it is an important condition for satisfying joint performance that each strand of the cable inside the joint is able to come to the outermost by transposition. This paper presents analysis, calculation and figures for the strand transposition. According to the twist procedures of the superconducting cable, the author computed the actual pitch of each stage cable, consecutively computed the projection of each stage cable on the axis of the cable (z axis) and the corresponding twist angle as the z coordinate changes, which is then drawn by AutoCAD. From the results shown in the figures, the minimal cable length, which enables each strand to transpose almost equally to the outermost of the cable in such a length, call be determined as the optimal joint length.
基金supported by ITER Research Project of China Matched Program(No.2008GB102000)
文摘A new method is developed for removing the nickel coating on ITER superconducting cables by mechanical polishing.The obvious advantage of the mechanical method,which uses a nylon brush,is that there is no chemical residual left in the cable,which would otherwise result in passive effects on the joint resistance.The coating resistance test results of this newly developed method are compared with those of the two other methods that can meet the requirements of ITER.An automatic polishing machine is designed and manufactured for the procedure to provide quality under precise control.This new technique can replace the conventional manual method due to its improved efficiency.
文摘Considering the insulators ageing in a mixture of PVC and dye, set following operating conditions and time to ensure proper operation and perfect safety of industrial installations using insulated conductors. The results showed that the insulation carried out by the L.C main office was a good quality (on thermal aspect), because the resistance of the insulation is so high (i.e. 3940 Mega Ohms under normal conditions). The results showed a lifespan of 50 years at a temperature of 40°C (close to ambient temperature), plus minus 33 years at a temperature of 70°C;plus minus 22 years at a temperature of 100°C and 12 years at a temperature of 160°C. Furthermore, information on chemical attack, the results showed that PVC cables have poor resistance to sulfuric acid attack (having a pH of 1.5 and a density of 1.84 g/cm<sup>3</sup>). LC/Gecamines is able to produce locally a good quality of electrical cables.