期刊文献+
共找到935篇文章
< 1 2 47 >
每页显示 20 50 100
Influence of alloy components on arc erosion morphology of Ag/MeO electrical contact materials 被引量:8
1
作者 吴春萍 易丹青 +2 位作者 翁桅 李素华 周孑民 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2016年第1期185-195,共11页
Arc erosion morphologies of Ag/MeO(10) electrical contact materials after 50000 operations under direct current of 19 V and 20 A and resistive load conditions were investigated using scanning electron microscope(SE... Arc erosion morphologies of Ag/MeO(10) electrical contact materials after 50000 operations under direct current of 19 V and 20 A and resistive load conditions were investigated using scanning electron microscope(SEM) and a 3D optical profiler(3DOP). The results indicated that 3DOP could supply clearer and more detailed arc erosion morphology information. Arc erosion resistance of Ag/SnO_2(10) electrical contact material was the best and that of Ag/CuO(10) was the worst. Arc erosion morphology of Ag/MeO(10) electrical contact materials mainly included three different types. Arc erosion morphologies of Ag/ZnO(10) and Ag/SnO_2(10) electrical contact materials were mainly liquid splash and evaporation, and those of Ag/CuO(10) and Ag/CdO(10) were mainly material transfer from anode to cathode. Arc erosion morphology of Ag/SnO_2(6)In_2O_3(4) electrical contact materials included both liquid splash, evaporation and material transfer. In addition, the formation process and mechanism on arc erosion morphology of Ag/MeO(10) electrical contact materials were discussed. 展开更多
关键词 Ag/MeO electrical contact material alloy component arc erosion morphology three-dimensional optical profiler
下载PDF
Differences in body components and electrical characteristics between youth soccer players and non-athletes
2
作者 Seung-Min Yang Won-Deok Lee +2 位作者 Ju-Hyun Kim Mee-Young Kim Junghwan Kim 《Health》 2013年第6期1010-1015,共6页
Many previous studies have focused on youth soccer player injuries without body component analysis compared to non-athletes. Only a few studies which have investigated body components of youth soccer players, and stud... Many previous studies have focused on youth soccer player injuries without body component analysis compared to non-athletes. Only a few studies which have investigated body components of youth soccer players, and studies that look at electrical characteristics used by rheobase and chronaxie as well as body components are even scarcer. Therefore, we feel that there is a need for a study investigating objective clinical analysis of the body components (body structure and body composition) and electrical characteristics of both youth soccer players and non-athletes. Sixty subjects participated in our study, comprising of thirty youth soccer players and thirty non-athletes. The Inbody 520 was used to measure and analyze body composition and the Duo 500 was employed to measure electrical characteristics. It was observed that the soccer players showed markedly lower total impedance compared to the non-athletes. In both legs, it was particularly noted that there were significant differences between the right and left sides. The soccer players showed a higher skeletal muscle mass and lean/ideal lean × 100% compared to the non-athletes. Furthermore, the soccer players had a lower rheobase and higher chronaxie. A comparison of the genders showed a similar pattern. In this study, we were able to separate the differences in body components and electrical characteristics between the subject groups using a systemic approach. Future studies on diverse types of athletes would contribute further to the development of clinical physiotherapy and sports rehabilitation. 展开更多
关键词 BODY componentS electrical Characteristics YOUTH SOCCER Players
下载PDF
The Electrical Conductive Effect of Nickel-coated Graphite/Two-component Silicone-rubber Sealant 被引量:1
3
作者 胡圣飞 LI Hui +2 位作者 CHEN Xiangxing ZHANG Chong LIU Zuifang 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2013年第3期429-436,共8页
Nickel-coated graphite particles and two-component silicone-rubber were compounded to form a conductive composite system. The electrical volume resistivity of the composites were examined and compared under constant t... Nickel-coated graphite particles and two-component silicone-rubber were compounded to form a conductive composite system. The electrical volume resistivity of the composites were examined and compared under constant tensile strains, cyclic heating-cooling, electric field and repeated cyclic tensile strains in order to study the mechanism of electrical conductivity behaviors of the conductive composites under stress, temperature and current. The results showed that a peak value of the electrical resistivity appeared previously and then gradually increasing with increasing tensile strain. The electrical resistivity displayed positive temperature coefficient effect during the temperature increasing and decreasing. Applying 5A direct current to the conductive composites lesulted in an increase in the electrical resistance immediately, but no changes were detected under lower currents. Under the repeated cyclic strain, the peak value of the electrical resistivity of each cycle increased with the test cycle. All the electrical resistivity changes were attributed to the conductive networks broken-up and rebuilt in the conductive composites. 展开更多
关键词 two-component silicone-rubber nickel-coated graphite volume resistivity electric current cyclic strain
下载PDF
Safety Requirements And Inspections Methods For Insulating Components Used In Electrical Accessories
4
作者 Chen Weidong Guo Chunyu 《International Journal of Technology Management》 2014年第8期43-45,共3页
This paper covers the safely requirements and inspection methods for insulating components used in electrical accessories by an analyzing the properties of the insulating components used in electrical accessories base... This paper covers the safely requirements and inspection methods for insulating components used in electrical accessories by an analyzing the properties of the insulating components used in electrical accessories based on the standard of IEC 60884. 展开更多
关键词 electrical accessories Insulating components Safety requirements Inspection methods
下载PDF
Electricity price forecasting using generalized regression neural network based on principal components analysis 被引量:1
5
作者 牛东晓 刘达 邢棉 《Journal of Central South University》 SCIE EI CAS 2008年第S2期316-320,共5页
A combined model based on principal components analysis (PCA) and generalized regression neural network (GRNN) was adopted to forecast electricity price in day-ahead electricity market. PCA was applied to mine the mai... A combined model based on principal components analysis (PCA) and generalized regression neural network (GRNN) was adopted to forecast electricity price in day-ahead electricity market. PCA was applied to mine the main influence on day-ahead price, avoiding the strong correlation between the input factors that might influence electricity price, such as the load of the forecasting hour, other history loads and prices, weather and temperature; then GRNN was employed to forecast electricity price according to the main information extracted by PCA. To prove the efficiency of the combined model, a case from PJM (Pennsylvania-New Jersey-Maryland) day-ahead electricity market was evaluated. Compared to back-propagation (BP) neural network and standard GRNN, the combined method reduces the mean absolute percentage error about 3%. 展开更多
关键词 electrICITY PRICE forecasting GENERALIZED regression NEURAL NETWORK principal componentS analysis
下载PDF
Effects of acrous gramimeus and its main component alpha-asarone on the reactivity and convulsive threshold of immature rats to electric stimulation 被引量:3
6
作者 Libin Yang Shulei Li +1 位作者 Yuhong Wang Yanzhi Huang 《Neural Regeneration Research》 SCIE CAS CSCD 2006年第1期78-80,共3页
BACKGROUND: The traditional Chinese medicine acrous gramimeus is the dry rhizome of Acrous gramimeus Soland, a kind of Araceae familial perennial herb, which has a sedation action, anticonvulsant and antiepileptic ef... BACKGROUND: The traditional Chinese medicine acrous gramimeus is the dry rhizome of Acrous gramimeus Soland, a kind of Araceae familial perennial herb, which has a sedation action, anticonvulsant and antiepileptic effect. Its effective component has not been known yet, and α-asarone, the major component of the volatile oil extracted from acrous gramineus, has been supposed to play a necessary role in it. OBJECTIVE: To explore the effects of acrous gramimeu and α-asarone on the reactivity and convulsive threshold to electric stimulation in immature rats, furthermore, attempt to definitize the anticonvulsant effect of α-asarone. DESIGN: A randomized controlled study.SETTINGS: Department of Pediatrics, First Hospital of Jilin University; Department of Histology and Embryology, School of Basic Medical Sciences of Jilin University; Department of Neurology, First Clinical Hospital affiliated to Harbin Medical University; Department of Internal Medicine, Children's Hospital of Changchun City. MATERIALS : Seventy 3-week immature Wistar rats (either males or females) of 34-40 g were used. Acrous gramimeu (1 g/bag, the content of α-oasarone was 0.046 26%-0.070 16%) with the batch number of 0307113 was provided by Tianjiang Medicine Company Limited, Jiangyin City. α-asarone tablet (60 mg per tablet) with the batch number of 030219 was provided by Tianwei Pharmaceutical Factory, Shenyang City. α-asarone injectable preparation (2 mL per piece) with the batch number of 030105 was provided by Shuanghe Medicine Limited Company, Beijing City. METHODS : The experiments were carried out in the Neurological Laboratory of the First Hospital of Jilin University between August and October in 2004.① The 70 rats were randomly divided into intragastric subset and intraperitoneal subset. The intragastric subset included four groups of control, phenobarbital sodium, acrous gramimeu and α-asarone; the intraperitoneal subset included three groups of control, phenobarbital sodium and α-asarone. There were 10 rats per group. ② In the intragastric subset, different group was treated with saline (1 mL for each time, phenobarbital sodium (18 mg/kg per day), acrous gramineu (2 350 mg/kg per day) and α-asarone (29 mg/kg per day) respectively twice every day for 5 days. In the intraperitoneal subset, different group was treated with saline (0.5 mL), phenobarbital sodium (29 mg/kg) and α-asarone (2.9 mg/kg) respectively. ③ Before and after administration for 5 days in the intragastric subset as well as before and after administration for about 1 hour in the intraperitoneal subset respectively, the rats were given electric stimulation with the NIHOM KOMDEM multifunctional electrophysiological recorder, and the reactivity and convulsive threshold to electric stimulation of the rats were recorded. MAIN OUTCOME MEASURES: The reactivity and convulsive threshold to electric stimulation in immature rats were compared. RESULTS: All the rats were involved in the analysis of results. ① Results for intragastric administration: Before intragastric administration, there were no obvious differences in the reactivity and convulsive threshold to electric stimulation among the groups (P 〉 0.05). After intragastric administration for 5 days, the reactivity and convulsive threshold to the electric stimulation had no obvious changes in the control group, but those were significantly higher than before administration in the drug administration groups (t=-3.317-7.401, P 〈 0.01), which were also obviously higher than those in the control group (t=3.027-8.941, P 〈 0.01), and those in the acrous gramimeu group and α-asarone group were not markedly different from those in the phenobarbital sodium group. ② Results for intraperitoneal injection: Before intraperitoneal injection, the reactivity and convulsive threshold to the electric stimulation had no obvious differences among the groups. After the intraperitoneal injection for 1 hour, the reactivity and convulsive threshold to the electric stimulation had no obvious change in the control group, but those were significantly higher than before administration in the drug administration groups (P 〈 0.01), which were also obviously higher than those in the control group (t=6.211-7.237, P 〈 0.01; t=4.085-5.633, P 〈 0.05), and there was no marked difference between α-asarone group and phenobarbital sodium group (P 〉 0.05).CONCLUSION : ① As effective anticonvulsants, both acrous gramineu and α-asarone can enhance the reactivity and convulsive threshold of immature rats to electric stimulation. ② As one of the major effective components against convulsion of acrous gramineu, α-asarone is equivalent to phenobarbital sodium. 展开更多
关键词 Effects of acrous gramimeus and its main component alpha-asarone on the reactivity and convulsive threshold of immature rats to electric stimulation THAN
下载PDF
Study on the Lightning-radaited Electric Field Components at Mesospheric Altitudes
7
作者 Fangrong ZHOU Yi MA +2 位作者 Hao PAN Bin ZOU Ye TIAN 《Meteorological and Environmental Research》 CAS 2021年第4期1-8,12,共9页
In this paper we have extended the semi-analytical model presented by Yashunin et al.to compute both of the lightning vertical and horizontal electric field considering the effect of nonlinear atmospheric electric par... In this paper we have extended the semi-analytical model presented by Yashunin et al.to compute both of the lightning vertical and horizontal electric field considering the effect of nonlinear atmospheric electric parameters,and validate its accuracy by using our 2-D FDTD method.It is noted that the semi-analytical model can predict not only the lightning vertical field,but also the horizontal electric field with a satisfied accuracy in a small region with a radius ranging from 5 to 30 km at a height from 80 to 90 km above the lightning strike point.Compared with the results in the free space with a vacuum,the conducting altitude atmosphere has a relatively little effect on the radiated field component,but it has much effect on the electrostatic and induction component because their duration times are longer than the local relaxation time.For example,the induction field component in the conducting nonlinear medium decreases by about 43%,compared with that in the free space with a vacuum.The induction field is larger than the radiation field component within a radius of 25 km at a height of 80 km above the lightning strike point.Therefore,although the induction component may be likely one extra energy source(except for the radiation field)for creating the pancake shape of some elves with a luminous central part,we have to take into account the effect of nonlinear atmospheric electric parameters on the prediction of induced field component peak value that is needed for the production of elves. 展开更多
关键词 Induction field component ELVES Semi-analytical model Nonlinear atmospheric electric parameters Effect
下载PDF
Design of Parallel Electrical Resistance Tomography System for Measuring Multiphase Flow 被引量:3
8
作者 董峰 许聪 +1 位作者 张志强 任尚杰 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2012年第2期368-379,共12页
ERT(electrical resistance tomography) is effective method for visualization of multiphase flows,offering some advantages of rapid response and low cost,so as to explore the transient hydrodynamics.Aiming at this targe... ERT(electrical resistance tomography) is effective method for visualization of multiphase flows,offering some advantages of rapid response and low cost,so as to explore the transient hydrodynamics.Aiming at this target,a fully programmable and reconfigurable FPGA(field programmable gate array)-based Compact PCI(peripheral component interconnect) bus linked sixteen-channel ERT system has been presented.The data acquisition system is carefully designed with function modules of signal generator module;Compact PCI transmission module and data processing module(including data sampling,filtering and demodulating).The processing module incorporates a powerful FPGA with Compact PCI bus for communication,and the measurement process management is conducted in FPGA.Image reconstruction algorithms with different speed and accuracy are also coded for this system.The system has been demonstrated in real time(1400 frames per second for 50 kHz excitation) with signal-noise-ratio above 62 dB and repeatability error below 0.7%.Static experiments have been conducted and the images manifested good resolution relative to the actual object distribution.The parallel ERT system has provided alternative experimental platform for the multiphase flow measurements by the dynamic experiments in terms of concentration and velocity. 展开更多
关键词 electrical resistance tomography data acquisition compact peripheral component interconnect field programmable gate array digital filter digital demodulation
下载PDF
Time Series of EIT Measurements and Images During Lung Ventilation Based on Principal Component Analysis
9
作者 范文茹 王化祥 +1 位作者 杨程屹 马世文 《Transactions of Tianjin University》 EI CAS 2010年第5期366-372,共7页
The aim of this paper is to propose a useful method for exploring regional ventilation and perfusion in the chest and also separation of pulmonary and cardiac changes.The approach is based on estimating both electrica... The aim of this paper is to propose a useful method for exploring regional ventilation and perfusion in the chest and also separation of pulmonary and cardiac changes.The approach is based on estimating both electrical impedance tomography(EIT) measurements and reconstructed images by means of principal component analysis(PCA).In the experiments in vivo,43 cycles of heart-beat rhythm could be detected by PCA when the volunteer held breath;9 breathing cycles and 50 heart-beat cycles could be detected by PCA ... 展开更多
关键词 electrical impedance tomography image reconstruction principal component analysis
下载PDF
Preventive condition-based maintenance model of EMU components based on stochastic differential equation
10
作者 HUANGFU Lanlan ZHAO Yifan SU Hongsheng 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2022年第3期345-351,共7页
To improve the operation and maintenance management level of large repairable components,such as electrical equipment,large nuclear power facilities,and high-speed electric multiple unit(EMU),and increase economic ben... To improve the operation and maintenance management level of large repairable components,such as electrical equipment,large nuclear power facilities,and high-speed electric multiple unit(EMU),and increase economic benefits,preventive maintenance has been widely used in industrial enterprises in recent years.Focusing on the problems of high maintenance costs and considerable failure hazards of EMU components in operation,we establish a state preventive maintenance model based on a stochastic differential equation.Firstly,a state degradation model of the repairable components is established in consideration of the degradation of the components and external random interference.Secondly,based on topology and martingale theory,the state degradation model is analyzed,and its simplex,stopping time,and martingale properties are proven.Finally,the monitoring data of the EMU components are taken as an example,analyzed and simulated to verify the effectiveness of the model. 展开更多
关键词 preventive maintenance stochastic differential equation SIMPLEX MARTINGALE electric multiple unit components
下载PDF
Numerical investigations on performance improvement mechanism of a high-power vertical centrifugal pump with special emphasis on hydraulic component matching
11
作者 Gang Yang Xi Shen +3 位作者 De-sheng Zhang Wen-hua Luo Jia Meng Xu-tao Zhao 《Journal of Hydrodynamics》 SCIE EI CSCD 2023年第4期649-667,共19页
The purpose of this paper is to investigate the performance improvement mechanism of a high power vertical centrifugal pump by using numerical calculations.Therefore,a comparative study of energy losses and internal f... The purpose of this paper is to investigate the performance improvement mechanism of a high power vertical centrifugal pump by using numerical calculations.Therefore,a comparative study of energy losses and internal flow characteristics in the original and optimized models was carried out with special attention to the hydraulic component matching.The optimized model(model B)was obtained by optimizing the vaned diffuser and volute based on the original model(model A),mainly the diffuser inlet diameter,diffuser inlet vane angle,volute channel inlet width and volute throat area were changed.Firstly,the comparative results on performance and energy losses of two models showed that the efficiency and head of model B was significantly increased under design and part-load conditions.It is mainly due to the dramatic reduction of energy loss PL in the diffuser and volute.Then,the comparisons of PL and flow patterns in the vaned diffuser showed that the matching optimization between the model B impeller outlet flow angle and diffuser inlet vane angle resulted in a better flow pattern in both the circumferential and axial directions of the diffuser,which leads to the PL3 reduction.The meridian velocity Vm of model B was significantly increased at diffuser inlet regions and resulted in improvements of flow patterns at diffuser middle and outlet regions as well as pressure expansion capacity.Finally,the comparisons of PL and flow characteristics in the volute showed that the turbulence loss reduction in the model B volute was due to the flow pattern improvement at diffuser outlet regions which provided better flow conditions at volute inlet regions.The matching optimization between the diffuser and volute significantly reduced the turbulence loss in volute sections 1–4 and enhanced the pressure expansion capacity in sections 8–10. 展开更多
关键词 high-power vertical centrifugal pump performance improvement mechanism hydraulic component matching flow pattern energy balance equation
原文传递
Fault Tree Analysis of the Reliability of Electric Vehicles in India
12
作者 Ritu Gupta 《Journal of Applied Mathematics and Physics》 2023年第7期1930-1944,共15页
Innovations for electric vehicles have advanced quickly in latest decades. Large-scale business use of these vehicles is still constrained by reliability-related issues. By utilising fault tree (FT) and Monte Carlo si... Innovations for electric vehicles have advanced quickly in latest decades. Large-scale business use of these vehicles is still constrained by reliability-related issues. By utilising fault tree (FT) and Monte Carlo simulation, a mathematical prototype is created that includes the reliability traits of all major electrical parts of the vehicle system, including the battery, motor, drive, controllers. The research demonstrates that by raising the component restoration rates, the vehicle’s survivability can be raised. A thorough discussion of this paradigm is provided, along with a presentation and analysis of the reliability estimations based on an electric vehicle. This research on the reliability design and maintenance of an electric vehicle can be supported by the ideas that are outlined in the paper. Additionally, the findings of this study may be helpful to those who build electric vehicle, especially when upgrading the components efficiency and planning for reliability increase. 展开更多
关键词 electric Vehicle Fault Tree Monte Carlo Simulation EV component Analysis
下载PDF
基于电成像的孔洞型碳酸盐岩储层连通性评价 被引量:1
13
作者 孙建孟 程耀东 +2 位作者 何娟 刘璋 陈培元 《测井技术》 CAS 2024年第1期75-83,116,共10页
碳酸盐岩储层非均质性强,孔隙结构复杂,相较于常规碎屑岩储层,其孔隙度、渗透率关系的规律及特征不明显。碳酸盐岩储层的连通性与孔洞特征具有强相关性,且连通性是影响储层渗透率的重要因素,因此,对碳酸盐岩孔洞连通性的评价是孔洞型碳... 碳酸盐岩储层非均质性强,孔隙结构复杂,相较于常规碎屑岩储层,其孔隙度、渗透率关系的规律及特征不明显。碳酸盐岩储层的连通性与孔洞特征具有强相关性,且连通性是影响储层渗透率的重要因素,因此,对碳酸盐岩孔洞连通性的评价是孔洞型碳酸盐岩储层评价的关键问题。以伊拉克东南部B油田FQ-1井M组MB21亚油组孔洞型碳酸盐岩储层为例,基于地层微电阻率扫描成像(FMI)测井的高分辨率动态图像,利用最大类间方差算法(OTSU)进行二次迭代分割,识别电成像图像孔洞;根据8连通域标记法标记连通孔洞;提取每个连通孔洞的特征孔径、内部最长通道距离、内部最长通道与水平方向夹角、平均通道宽度这4个几何参数,最终构建孔洞型碳酸盐岩储层连通指数。连通指数在伊拉克东南部B油田FQ-1井M组MB21亚油组孔洞型碳酸盐岩储层的应用表明,利用此方法建立的连通指数与FQ-1井碳酸盐岩储层岩心渗透率相关系数达0.8437,并且连通指数曲线的趋势符合岩心渗透率在储层不同深度的分布情况,证明了连通指数可以指示储层孔隙结构较好、溶蚀孔洞发育的深度段,并可以划分储层中连通性较好的深度区间,该参数对于寻找碳酸盐岩储层渗透层具有重要意义。 展开更多
关键词 孔洞型碳酸盐岩 连通指数 电成像测井 孔洞识别 连通域标记
下载PDF
基于相位差的轴向磁通无铁心电机早期轻微匝间短路故障诊断 被引量:1
14
作者 王晓光 陈梦凯 +2 位作者 周一帆 岳明强 陈亚红 《河北科技大学学报》 CAS 北大核心 2024年第2期111-121,共11页
针对轴向磁通定子无铁心电机早期匝间短路故障问题,提出一种基于零序分量和定子电流分量相位差的轴向磁通定子无铁心电机的早期匝间短路故障诊断和定位方法。首先,根据定子绕组电感极小的特点建立了匝间短路故障数学模型;其次,对故障前... 针对轴向磁通定子无铁心电机早期匝间短路故障问题,提出一种基于零序分量和定子电流分量相位差的轴向磁通定子无铁心电机的早期匝间短路故障诊断和定位方法。首先,根据定子绕组电感极小的特点建立了匝间短路故障数学模型;其次,对故障前后的短路电流、相电流、零序分量等进行了傅里叶分析,通过零序电压基波幅值变化对匝间短路故障进行识别;最后,通过对比零序电压基波与定子三相电流初相位差来进行故障相定位。结果表明,匝间短路故障相的相电流基波初始相位与零序电压基波初相位差的绝对值近似180°,而健康相的相位差与180°相差较大。基于相位差可以实现轴向磁通无铁心电机早期匝间短路故障的诊断与定位,为永磁电机的匝间短路故障诊断提供了参考。 展开更多
关键词 电机学 匝间短路 无铁心电机 故障诊断 零序分量 傅里叶分析
下载PDF
电气部件三维建模方法探析——以交流接触器为例
15
作者 刘艺柱 王珍海 王占辉 《天津中德应用技术大学学报》 2024年第5期65-69,共5页
介绍数字化电气设计中电气部件常用的两种三维建模方法,详细描述基于外形尺寸的三维绘制和借助扫描仪进行三维扫描建模的具体操作流程及注意事项。通过比较两种建模方法的优缺点,供设计者在实践中选择合适的建模方法,提高设计效率和准... 介绍数字化电气设计中电气部件常用的两种三维建模方法,详细描述基于外形尺寸的三维绘制和借助扫描仪进行三维扫描建模的具体操作流程及注意事项。通过比较两种建模方法的优缺点,供设计者在实践中选择合适的建模方法,提高设计效率和准确性。 展开更多
关键词 电气部件 三维建模 交流接触器 三维扫描
下载PDF
基于电学特性识别贺兰山东麓年份葡萄酒研究
16
作者 朱娟娟 马海军 +2 位作者 杨胜云 梁洪 安雅静 《中外葡萄与葡萄酒》 北大核心 2024年第2期37-47,共11页
以贺兰山东麓3个年份两个品种的葡萄酒为试材,运用LCR仪测定其电学特性,分析不同激励电压(1、3、5 V)和不同频率(0.1、1.0、10.0、100.0、1000.0 kHz)下葡萄酒间电学特性的差异,筛选出识别年份葡萄酒的最适激励电压、频率和有效电学参数... 以贺兰山东麓3个年份两个品种的葡萄酒为试材,运用LCR仪测定其电学特性,分析不同激励电压(1、3、5 V)和不同频率(0.1、1.0、10.0、100.0、1000.0 kHz)下葡萄酒间电学特性的差异,筛选出识别年份葡萄酒的最适激励电压、频率和有效电学参数,探索利用电学特性识别贺兰山东麓年份葡萄酒的可行性。结果表明,在本研究中葡萄酒电学参数在不同电压下随频率的增加变化趋势一致,但不同年份间分离程度有所差异。在本研究中,随着频率的增加,葡萄酒电学参数Z值和Cp值逐渐减小,G值逐渐增加,θ值先增后减,B值则先减后增;而D值仅‘赤霞珠’葡萄酒在1 V+0.1 kHz条件下存在显著差异。通过多元统计分析,LCR仪在5 V激励电压+1.0 kHz频率条件下,能够利用Z、Cp、G、θ和B这5个电学参数来识别贺兰山东麓‘赤霞珠’和‘雷司令’年份葡萄酒。 展开更多
关键词 年份葡萄酒 电学特性 主成分分析 正交偏最小二乘判别分析
下载PDF
基于电学参数的贺兰山东麓赤霞珠葡萄酒子产区判别
17
作者 马海军 朱娟娟 +2 位作者 周乃帅 安雅静 侯丽君 《农业机械学报》 EI CAS CSCD 北大核心 2024年第3期375-382,共8页
本研究以宁夏贺兰山东麓5个子产区(银川、青铜峡、红寺堡、石嘴山和农垦产区)自然发酵的赤霞珠干红葡萄酒为研究对象,测定其基本理化指标和电学特性,分析不同产区葡萄酒间电学特性的差异,筛选出区分不同产区葡萄酒的特征频率和有效电学... 本研究以宁夏贺兰山东麓5个子产区(银川、青铜峡、红寺堡、石嘴山和农垦产区)自然发酵的赤霞珠干红葡萄酒为研究对象,测定其基本理化指标和电学特性,分析不同产区葡萄酒间电学特性的差异,筛选出区分不同产区葡萄酒的特征频率和有效电学参数,初步探索基于电学特性识别宁夏贺兰山东麓不同子产区葡萄酒的能力,以期为简捷快速有效识别产区葡萄酒提供新方法。结果表明,宁夏贺兰山东麓5个子产区的葡萄酒理化指标间存在显著性差异,农垦产区的葡萄酒可滴定酸含量最高,而还原糖含量最低;银川产区的葡萄酒挥发酸含量最低,石嘴山产区的葡萄酒酒精度最高。通过相关性分析、方差分析和多重比较,筛选出电压2 V下,区分不同产区葡萄酒的电学特性特征频率为0.1 kHz,有效电学参数为Z、L_(p)、X、C_(p)和Q。主成分分析和判别分析均显示,利用葡萄酒电学参数能够明显区分贺兰山东麓5个子产区,采用Fisher-判别分析建立的预测模型,其回代检测和交叉验证正确率均为100%。因此,利用葡萄酒电学特性识别产区具有可行性。 展开更多
关键词 葡萄酒产区判别 赤霞珠 自然发酵葡萄酒 电学特性 主成分分析 判别分析
下载PDF
CEEMD-FastICA-CWT联合瞬态响应阶次的电驱总成噪声源识别
18
作者 张威 景国玺 +2 位作者 武一民 杨征睿 高辉 《中国测试》 CAS 北大核心 2024年第4期144-152,共9页
以某增程式电驱动总成为研究对象,提出基于联合算法的噪声分离识别模型。首先,采用互补集合经验模态分解(complementary ensemble empirical mode decomposition,CEEMD)联合快速独立分量分析(fast independent component analysis,FastI... 以某增程式电驱动总成为研究对象,提出基于联合算法的噪声分离识别模型。首先,采用互补集合经验模态分解(complementary ensemble empirical mode decomposition,CEEMD)联合快速独立分量分析(fast independent component analysis,FastICA)方法提取纯电模式稳态工况下单一通道噪声信号特征,利用复Morlet小波变换及FFT对各分量信号时频特性进行识别。其次,采用阶次分析法和声能叠加法对稳态分量信号对应的各瞬态响应阶次能量进行对比分析,并结合皮尔逊积矩相关系数(Pearson product moment correlation coefficient,PPMCC)相似性识别确定不同噪声激励源贡献度。结果表明:减速齿副啮合噪声对该增程式电驱总成纯电模式运行噪声整体贡献度最大。 展开更多
关键词 电驱动总成 噪声源识别 互补集合经验模态分解 快速独立分量分析 连续小波变换 阶次分析
下载PDF
神东煤矿机电设备大型部件安全库存分析
19
作者 谢明军 白晶 +3 位作者 郭建军 李阴保 谢小飞 李婷 《陕西煤炭》 2024年第6期148-152,共5页
为探讨煤矿机电设备大型部件安全库存的必要性以及对煤企安全生产的影响,通过调研国能神东机电设备大型部件库存的现状,给出了保障国能神东煤矿机电设备大型部件安全库存的具体措施。分析认为,开展机电设备大型部件库存统计对实现国能... 为探讨煤矿机电设备大型部件安全库存的必要性以及对煤企安全生产的影响,通过调研国能神东机电设备大型部件库存的现状,给出了保障国能神东煤矿机电设备大型部件安全库存的具体措施。分析认为,开展机电设备大型部件库存统计对实现国能神东在管理上的提质降本增效有重要的作用,且在实践中应建立一套符合神东模式的机电设备大型部件安全库存储备标准,有助于为设备管理提供科学精准的参考。 展开更多
关键词 神东煤矿 降本增效 机电设备 大型部件 安全库存
下载PDF
热态C_(5)F_(10)O/CO_(2)混合气体电击穿特性研究 被引量:1
20
作者 崔兆轩 林莘 +1 位作者 徐建源 李磊 《高压电器》 CAS CSCD 北大核心 2024年第4期10-16,23,共8页
热态气体的临界击穿场强是评估高压断路器弧后电击穿特性的基础数据,文中研究了C_(5)F_(10)O/CO_(2)混合气体在C_(5)F_(10)O混合比例k=0~10%、压强0.1~2.0 MPa、温度300~4 000 K范围内的临界击穿场强。基于质量作用定律数学模型,得到不... 热态气体的临界击穿场强是评估高压断路器弧后电击穿特性的基础数据,文中研究了C_(5)F_(10)O/CO_(2)混合气体在C_(5)F_(10)O混合比例k=0~10%、压强0.1~2.0 MPa、温度300~4 000 K范围内的临界击穿场强。基于质量作用定律数学模型,得到不同温度下混合气体的平衡组分,采用两项近似方法求解玻尔兹曼方程,分析混合气体的电子能量分布函数、折合电离和吸附系数,获得混合气体的临界折合击穿场强和临界击穿场强。结果表明:0.6 MPa下,温度低于3 000 K时,随着温度降低,k=0~10%混合气体的临界击穿场逐渐低于SF_(6);在温度高于3 000 K时,混合气体的临界击穿场强为SF_(6)的1.2倍以上,具有较强的绝缘能力。研究结果可为C_(5)F_(10)O/CO_(2)混合气体高压断路器弧后电击穿特性研究提供参考。 展开更多
关键词 C_(5)F_(10)O/CO_(2)混合气体 SF_(6)替代气体 电击穿特性 临界击穿场强 粒子组分 玻尔兹曼方程
下载PDF
上一页 1 2 47 下一页 到第