Arc erosion morphologies of Ag/MeO(10) electrical contact materials after 50000 operations under direct current of 19 V and 20 A and resistive load conditions were investigated using scanning electron microscope(SE...Arc erosion morphologies of Ag/MeO(10) electrical contact materials after 50000 operations under direct current of 19 V and 20 A and resistive load conditions were investigated using scanning electron microscope(SEM) and a 3D optical profiler(3DOP). The results indicated that 3DOP could supply clearer and more detailed arc erosion morphology information. Arc erosion resistance of Ag/SnO_2(10) electrical contact material was the best and that of Ag/CuO(10) was the worst. Arc erosion morphology of Ag/MeO(10) electrical contact materials mainly included three different types. Arc erosion morphologies of Ag/ZnO(10) and Ag/SnO_2(10) electrical contact materials were mainly liquid splash and evaporation, and those of Ag/CuO(10) and Ag/CdO(10) were mainly material transfer from anode to cathode. Arc erosion morphology of Ag/SnO_2(6)In_2O_3(4) electrical contact materials included both liquid splash, evaporation and material transfer. In addition, the formation process and mechanism on arc erosion morphology of Ag/MeO(10) electrical contact materials were discussed.展开更多
Many previous studies have focused on youth soccer player injuries without body component analysis compared to non-athletes. Only a few studies which have investigated body components of youth soccer players, and stud...Many previous studies have focused on youth soccer player injuries without body component analysis compared to non-athletes. Only a few studies which have investigated body components of youth soccer players, and studies that look at electrical characteristics used by rheobase and chronaxie as well as body components are even scarcer. Therefore, we feel that there is a need for a study investigating objective clinical analysis of the body components (body structure and body composition) and electrical characteristics of both youth soccer players and non-athletes. Sixty subjects participated in our study, comprising of thirty youth soccer players and thirty non-athletes. The Inbody 520 was used to measure and analyze body composition and the Duo 500 was employed to measure electrical characteristics. It was observed that the soccer players showed markedly lower total impedance compared to the non-athletes. In both legs, it was particularly noted that there were significant differences between the right and left sides. The soccer players showed a higher skeletal muscle mass and lean/ideal lean × 100% compared to the non-athletes. Furthermore, the soccer players had a lower rheobase and higher chronaxie. A comparison of the genders showed a similar pattern. In this study, we were able to separate the differences in body components and electrical characteristics between the subject groups using a systemic approach. Future studies on diverse types of athletes would contribute further to the development of clinical physiotherapy and sports rehabilitation.展开更多
Nickel-coated graphite particles and two-component silicone-rubber were compounded to form a conductive composite system. The electrical volume resistivity of the composites were examined and compared under constant t...Nickel-coated graphite particles and two-component silicone-rubber were compounded to form a conductive composite system. The electrical volume resistivity of the composites were examined and compared under constant tensile strains, cyclic heating-cooling, electric field and repeated cyclic tensile strains in order to study the mechanism of electrical conductivity behaviors of the conductive composites under stress, temperature and current. The results showed that a peak value of the electrical resistivity appeared previously and then gradually increasing with increasing tensile strain. The electrical resistivity displayed positive temperature coefficient effect during the temperature increasing and decreasing. Applying 5A direct current to the conductive composites lesulted in an increase in the electrical resistance immediately, but no changes were detected under lower currents. Under the repeated cyclic strain, the peak value of the electrical resistivity of each cycle increased with the test cycle. All the electrical resistivity changes were attributed to the conductive networks broken-up and rebuilt in the conductive composites.展开更多
This paper covers the safely requirements and inspection methods for insulating components used in electrical accessories by an analyzing the properties of the insulating components used in electrical accessories base...This paper covers the safely requirements and inspection methods for insulating components used in electrical accessories by an analyzing the properties of the insulating components used in electrical accessories based on the standard of IEC 60884.展开更多
A combined model based on principal components analysis (PCA) and generalized regression neural network (GRNN) was adopted to forecast electricity price in day-ahead electricity market. PCA was applied to mine the mai...A combined model based on principal components analysis (PCA) and generalized regression neural network (GRNN) was adopted to forecast electricity price in day-ahead electricity market. PCA was applied to mine the main influence on day-ahead price, avoiding the strong correlation between the input factors that might influence electricity price, such as the load of the forecasting hour, other history loads and prices, weather and temperature; then GRNN was employed to forecast electricity price according to the main information extracted by PCA. To prove the efficiency of the combined model, a case from PJM (Pennsylvania-New Jersey-Maryland) day-ahead electricity market was evaluated. Compared to back-propagation (BP) neural network and standard GRNN, the combined method reduces the mean absolute percentage error about 3%.展开更多
BACKGROUND: The traditional Chinese medicine acrous gramimeus is the dry rhizome of Acrous gramimeus Soland, a kind of Araceae familial perennial herb, which has a sedation action, anticonvulsant and antiepileptic ef...BACKGROUND: The traditional Chinese medicine acrous gramimeus is the dry rhizome of Acrous gramimeus Soland, a kind of Araceae familial perennial herb, which has a sedation action, anticonvulsant and antiepileptic effect. Its effective component has not been known yet, and α-asarone, the major component of the volatile oil extracted from acrous gramineus, has been supposed to play a necessary role in it. OBJECTIVE: To explore the effects of acrous gramimeu and α-asarone on the reactivity and convulsive threshold to electric stimulation in immature rats, furthermore, attempt to definitize the anticonvulsant effect of α-asarone. DESIGN: A randomized controlled study.SETTINGS: Department of Pediatrics, First Hospital of Jilin University; Department of Histology and Embryology, School of Basic Medical Sciences of Jilin University; Department of Neurology, First Clinical Hospital affiliated to Harbin Medical University; Department of Internal Medicine, Children's Hospital of Changchun City. MATERIALS : Seventy 3-week immature Wistar rats (either males or females) of 34-40 g were used. Acrous gramimeu (1 g/bag, the content of α-oasarone was 0.046 26%-0.070 16%) with the batch number of 0307113 was provided by Tianjiang Medicine Company Limited, Jiangyin City. α-asarone tablet (60 mg per tablet) with the batch number of 030219 was provided by Tianwei Pharmaceutical Factory, Shenyang City. α-asarone injectable preparation (2 mL per piece) with the batch number of 030105 was provided by Shuanghe Medicine Limited Company, Beijing City. METHODS : The experiments were carried out in the Neurological Laboratory of the First Hospital of Jilin University between August and October in 2004.① The 70 rats were randomly divided into intragastric subset and intraperitoneal subset. The intragastric subset included four groups of control, phenobarbital sodium, acrous gramimeu and α-asarone; the intraperitoneal subset included three groups of control, phenobarbital sodium and α-asarone. There were 10 rats per group. ② In the intragastric subset, different group was treated with saline (1 mL for each time, phenobarbital sodium (18 mg/kg per day), acrous gramineu (2 350 mg/kg per day) and α-asarone (29 mg/kg per day) respectively twice every day for 5 days. In the intraperitoneal subset, different group was treated with saline (0.5 mL), phenobarbital sodium (29 mg/kg) and α-asarone (2.9 mg/kg) respectively. ③ Before and after administration for 5 days in the intragastric subset as well as before and after administration for about 1 hour in the intraperitoneal subset respectively, the rats were given electric stimulation with the NIHOM KOMDEM multifunctional electrophysiological recorder, and the reactivity and convulsive threshold to electric stimulation of the rats were recorded. MAIN OUTCOME MEASURES: The reactivity and convulsive threshold to electric stimulation in immature rats were compared. RESULTS: All the rats were involved in the analysis of results. ① Results for intragastric administration: Before intragastric administration, there were no obvious differences in the reactivity and convulsive threshold to electric stimulation among the groups (P 〉 0.05). After intragastric administration for 5 days, the reactivity and convulsive threshold to the electric stimulation had no obvious changes in the control group, but those were significantly higher than before administration in the drug administration groups (t=-3.317-7.401, P 〈 0.01), which were also obviously higher than those in the control group (t=3.027-8.941, P 〈 0.01), and those in the acrous gramimeu group and α-asarone group were not markedly different from those in the phenobarbital sodium group. ② Results for intraperitoneal injection: Before intraperitoneal injection, the reactivity and convulsive threshold to the electric stimulation had no obvious differences among the groups. After the intraperitoneal injection for 1 hour, the reactivity and convulsive threshold to the electric stimulation had no obvious change in the control group, but those were significantly higher than before administration in the drug administration groups (P 〈 0.01), which were also obviously higher than those in the control group (t=6.211-7.237, P 〈 0.01; t=4.085-5.633, P 〈 0.05), and there was no marked difference between α-asarone group and phenobarbital sodium group (P 〉 0.05).CONCLUSION : ① As effective anticonvulsants, both acrous gramineu and α-asarone can enhance the reactivity and convulsive threshold of immature rats to electric stimulation. ② As one of the major effective components against convulsion of acrous gramineu, α-asarone is equivalent to phenobarbital sodium.展开更多
In this paper we have extended the semi-analytical model presented by Yashunin et al.to compute both of the lightning vertical and horizontal electric field considering the effect of nonlinear atmospheric electric par...In this paper we have extended the semi-analytical model presented by Yashunin et al.to compute both of the lightning vertical and horizontal electric field considering the effect of nonlinear atmospheric electric parameters,and validate its accuracy by using our 2-D FDTD method.It is noted that the semi-analytical model can predict not only the lightning vertical field,but also the horizontal electric field with a satisfied accuracy in a small region with a radius ranging from 5 to 30 km at a height from 80 to 90 km above the lightning strike point.Compared with the results in the free space with a vacuum,the conducting altitude atmosphere has a relatively little effect on the radiated field component,but it has much effect on the electrostatic and induction component because their duration times are longer than the local relaxation time.For example,the induction field component in the conducting nonlinear medium decreases by about 43%,compared with that in the free space with a vacuum.The induction field is larger than the radiation field component within a radius of 25 km at a height of 80 km above the lightning strike point.Therefore,although the induction component may be likely one extra energy source(except for the radiation field)for creating the pancake shape of some elves with a luminous central part,we have to take into account the effect of nonlinear atmospheric electric parameters on the prediction of induced field component peak value that is needed for the production of elves.展开更多
ERT(electrical resistance tomography) is effective method for visualization of multiphase flows,offering some advantages of rapid response and low cost,so as to explore the transient hydrodynamics.Aiming at this targe...ERT(electrical resistance tomography) is effective method for visualization of multiphase flows,offering some advantages of rapid response and low cost,so as to explore the transient hydrodynamics.Aiming at this target,a fully programmable and reconfigurable FPGA(field programmable gate array)-based Compact PCI(peripheral component interconnect) bus linked sixteen-channel ERT system has been presented.The data acquisition system is carefully designed with function modules of signal generator module;Compact PCI transmission module and data processing module(including data sampling,filtering and demodulating).The processing module incorporates a powerful FPGA with Compact PCI bus for communication,and the measurement process management is conducted in FPGA.Image reconstruction algorithms with different speed and accuracy are also coded for this system.The system has been demonstrated in real time(1400 frames per second for 50 kHz excitation) with signal-noise-ratio above 62 dB and repeatability error below 0.7%.Static experiments have been conducted and the images manifested good resolution relative to the actual object distribution.The parallel ERT system has provided alternative experimental platform for the multiphase flow measurements by the dynamic experiments in terms of concentration and velocity.展开更多
The aim of this paper is to propose a useful method for exploring regional ventilation and perfusion in the chest and also separation of pulmonary and cardiac changes.The approach is based on estimating both electrica...The aim of this paper is to propose a useful method for exploring regional ventilation and perfusion in the chest and also separation of pulmonary and cardiac changes.The approach is based on estimating both electrical impedance tomography(EIT) measurements and reconstructed images by means of principal component analysis(PCA).In the experiments in vivo,43 cycles of heart-beat rhythm could be detected by PCA when the volunteer held breath;9 breathing cycles and 50 heart-beat cycles could be detected by PCA ...展开更多
To improve the operation and maintenance management level of large repairable components,such as electrical equipment,large nuclear power facilities,and high-speed electric multiple unit(EMU),and increase economic ben...To improve the operation and maintenance management level of large repairable components,such as electrical equipment,large nuclear power facilities,and high-speed electric multiple unit(EMU),and increase economic benefits,preventive maintenance has been widely used in industrial enterprises in recent years.Focusing on the problems of high maintenance costs and considerable failure hazards of EMU components in operation,we establish a state preventive maintenance model based on a stochastic differential equation.Firstly,a state degradation model of the repairable components is established in consideration of the degradation of the components and external random interference.Secondly,based on topology and martingale theory,the state degradation model is analyzed,and its simplex,stopping time,and martingale properties are proven.Finally,the monitoring data of the EMU components are taken as an example,analyzed and simulated to verify the effectiveness of the model.展开更多
The purpose of this paper is to investigate the performance improvement mechanism of a high power vertical centrifugal pump by using numerical calculations.Therefore,a comparative study of energy losses and internal f...The purpose of this paper is to investigate the performance improvement mechanism of a high power vertical centrifugal pump by using numerical calculations.Therefore,a comparative study of energy losses and internal flow characteristics in the original and optimized models was carried out with special attention to the hydraulic component matching.The optimized model(model B)was obtained by optimizing the vaned diffuser and volute based on the original model(model A),mainly the diffuser inlet diameter,diffuser inlet vane angle,volute channel inlet width and volute throat area were changed.Firstly,the comparative results on performance and energy losses of two models showed that the efficiency and head of model B was significantly increased under design and part-load conditions.It is mainly due to the dramatic reduction of energy loss PL in the diffuser and volute.Then,the comparisons of PL and flow patterns in the vaned diffuser showed that the matching optimization between the model B impeller outlet flow angle and diffuser inlet vane angle resulted in a better flow pattern in both the circumferential and axial directions of the diffuser,which leads to the PL3 reduction.The meridian velocity Vm of model B was significantly increased at diffuser inlet regions and resulted in improvements of flow patterns at diffuser middle and outlet regions as well as pressure expansion capacity.Finally,the comparisons of PL and flow characteristics in the volute showed that the turbulence loss reduction in the model B volute was due to the flow pattern improvement at diffuser outlet regions which provided better flow conditions at volute inlet regions.The matching optimization between the diffuser and volute significantly reduced the turbulence loss in volute sections 1–4 and enhanced the pressure expansion capacity in sections 8–10.展开更多
Innovations for electric vehicles have advanced quickly in latest decades. Large-scale business use of these vehicles is still constrained by reliability-related issues. By utilising fault tree (FT) and Monte Carlo si...Innovations for electric vehicles have advanced quickly in latest decades. Large-scale business use of these vehicles is still constrained by reliability-related issues. By utilising fault tree (FT) and Monte Carlo simulation, a mathematical prototype is created that includes the reliability traits of all major electrical parts of the vehicle system, including the battery, motor, drive, controllers. The research demonstrates that by raising the component restoration rates, the vehicle’s survivability can be raised. A thorough discussion of this paradigm is provided, along with a presentation and analysis of the reliability estimations based on an electric vehicle. This research on the reliability design and maintenance of an electric vehicle can be supported by the ideas that are outlined in the paper. Additionally, the findings of this study may be helpful to those who build electric vehicle, especially when upgrading the components efficiency and planning for reliability increase.展开更多
基金Project(2012QNZT003)supported by the Fundamental Research Funds for the Central Universities,ChinaProject(2012M521542)supported by the Postdoctoral Science Foundation of China+1 种基金Project(14JJ3014)supported by the Hunan Provincial Natural Science Foundation of ChinaProject(BSh1202)supported by the Zhejiang Provincial Postdoctoral Scientific Research Foundation of China
文摘Arc erosion morphologies of Ag/MeO(10) electrical contact materials after 50000 operations under direct current of 19 V and 20 A and resistive load conditions were investigated using scanning electron microscope(SEM) and a 3D optical profiler(3DOP). The results indicated that 3DOP could supply clearer and more detailed arc erosion morphology information. Arc erosion resistance of Ag/SnO_2(10) electrical contact material was the best and that of Ag/CuO(10) was the worst. Arc erosion morphology of Ag/MeO(10) electrical contact materials mainly included three different types. Arc erosion morphologies of Ag/ZnO(10) and Ag/SnO_2(10) electrical contact materials were mainly liquid splash and evaporation, and those of Ag/CuO(10) and Ag/CdO(10) were mainly material transfer from anode to cathode. Arc erosion morphology of Ag/SnO_2(6)In_2O_3(4) electrical contact materials included both liquid splash, evaporation and material transfer. In addition, the formation process and mechanism on arc erosion morphology of Ag/MeO(10) electrical contact materials were discussed.
文摘Many previous studies have focused on youth soccer player injuries without body component analysis compared to non-athletes. Only a few studies which have investigated body components of youth soccer players, and studies that look at electrical characteristics used by rheobase and chronaxie as well as body components are even scarcer. Therefore, we feel that there is a need for a study investigating objective clinical analysis of the body components (body structure and body composition) and electrical characteristics of both youth soccer players and non-athletes. Sixty subjects participated in our study, comprising of thirty youth soccer players and thirty non-athletes. The Inbody 520 was used to measure and analyze body composition and the Duo 500 was employed to measure electrical characteristics. It was observed that the soccer players showed markedly lower total impedance compared to the non-athletes. In both legs, it was particularly noted that there were significant differences between the right and left sides. The soccer players showed a higher skeletal muscle mass and lean/ideal lean × 100% compared to the non-athletes. Furthermore, the soccer players had a lower rheobase and higher chronaxie. A comparison of the genders showed a similar pattern. In this study, we were able to separate the differences in body components and electrical characteristics between the subject groups using a systemic approach. Future studies on diverse types of athletes would contribute further to the development of clinical physiotherapy and sports rehabilitation.
基金Funded by Wuhan Science and Technology Bureau (No.200710321090-18)
文摘Nickel-coated graphite particles and two-component silicone-rubber were compounded to form a conductive composite system. The electrical volume resistivity of the composites were examined and compared under constant tensile strains, cyclic heating-cooling, electric field and repeated cyclic tensile strains in order to study the mechanism of electrical conductivity behaviors of the conductive composites under stress, temperature and current. The results showed that a peak value of the electrical resistivity appeared previously and then gradually increasing with increasing tensile strain. The electrical resistivity displayed positive temperature coefficient effect during the temperature increasing and decreasing. Applying 5A direct current to the conductive composites lesulted in an increase in the electrical resistance immediately, but no changes were detected under lower currents. Under the repeated cyclic strain, the peak value of the electrical resistivity of each cycle increased with the test cycle. All the electrical resistivity changes were attributed to the conductive networks broken-up and rebuilt in the conductive composites.
文摘This paper covers the safely requirements and inspection methods for insulating components used in electrical accessories by an analyzing the properties of the insulating components used in electrical accessories based on the standard of IEC 60884.
基金Project(70671039) supported by the National Natural Science Foundation of China
文摘A combined model based on principal components analysis (PCA) and generalized regression neural network (GRNN) was adopted to forecast electricity price in day-ahead electricity market. PCA was applied to mine the main influence on day-ahead price, avoiding the strong correlation between the input factors that might influence electricity price, such as the load of the forecasting hour, other history loads and prices, weather and temperature; then GRNN was employed to forecast electricity price according to the main information extracted by PCA. To prove the efficiency of the combined model, a case from PJM (Pennsylvania-New Jersey-Maryland) day-ahead electricity market was evaluated. Compared to back-propagation (BP) neural network and standard GRNN, the combined method reduces the mean absolute percentage error about 3%.
基金grants from Changchun Bureau of Science and Technology, No. 20030430 Traditional Chinese Medicine and Drug Administration of Jilin Province, No. 2004079
文摘BACKGROUND: The traditional Chinese medicine acrous gramimeus is the dry rhizome of Acrous gramimeus Soland, a kind of Araceae familial perennial herb, which has a sedation action, anticonvulsant and antiepileptic effect. Its effective component has not been known yet, and α-asarone, the major component of the volatile oil extracted from acrous gramineus, has been supposed to play a necessary role in it. OBJECTIVE: To explore the effects of acrous gramimeu and α-asarone on the reactivity and convulsive threshold to electric stimulation in immature rats, furthermore, attempt to definitize the anticonvulsant effect of α-asarone. DESIGN: A randomized controlled study.SETTINGS: Department of Pediatrics, First Hospital of Jilin University; Department of Histology and Embryology, School of Basic Medical Sciences of Jilin University; Department of Neurology, First Clinical Hospital affiliated to Harbin Medical University; Department of Internal Medicine, Children's Hospital of Changchun City. MATERIALS : Seventy 3-week immature Wistar rats (either males or females) of 34-40 g were used. Acrous gramimeu (1 g/bag, the content of α-oasarone was 0.046 26%-0.070 16%) with the batch number of 0307113 was provided by Tianjiang Medicine Company Limited, Jiangyin City. α-asarone tablet (60 mg per tablet) with the batch number of 030219 was provided by Tianwei Pharmaceutical Factory, Shenyang City. α-asarone injectable preparation (2 mL per piece) with the batch number of 030105 was provided by Shuanghe Medicine Limited Company, Beijing City. METHODS : The experiments were carried out in the Neurological Laboratory of the First Hospital of Jilin University between August and October in 2004.① The 70 rats were randomly divided into intragastric subset and intraperitoneal subset. The intragastric subset included four groups of control, phenobarbital sodium, acrous gramimeu and α-asarone; the intraperitoneal subset included three groups of control, phenobarbital sodium and α-asarone. There were 10 rats per group. ② In the intragastric subset, different group was treated with saline (1 mL for each time, phenobarbital sodium (18 mg/kg per day), acrous gramineu (2 350 mg/kg per day) and α-asarone (29 mg/kg per day) respectively twice every day for 5 days. In the intraperitoneal subset, different group was treated with saline (0.5 mL), phenobarbital sodium (29 mg/kg) and α-asarone (2.9 mg/kg) respectively. ③ Before and after administration for 5 days in the intragastric subset as well as before and after administration for about 1 hour in the intraperitoneal subset respectively, the rats were given electric stimulation with the NIHOM KOMDEM multifunctional electrophysiological recorder, and the reactivity and convulsive threshold to electric stimulation of the rats were recorded. MAIN OUTCOME MEASURES: The reactivity and convulsive threshold to electric stimulation in immature rats were compared. RESULTS: All the rats were involved in the analysis of results. ① Results for intragastric administration: Before intragastric administration, there were no obvious differences in the reactivity and convulsive threshold to electric stimulation among the groups (P 〉 0.05). After intragastric administration for 5 days, the reactivity and convulsive threshold to the electric stimulation had no obvious changes in the control group, but those were significantly higher than before administration in the drug administration groups (t=-3.317-7.401, P 〈 0.01), which were also obviously higher than those in the control group (t=3.027-8.941, P 〈 0.01), and those in the acrous gramimeu group and α-asarone group were not markedly different from those in the phenobarbital sodium group. ② Results for intraperitoneal injection: Before intraperitoneal injection, the reactivity and convulsive threshold to the electric stimulation had no obvious differences among the groups. After the intraperitoneal injection for 1 hour, the reactivity and convulsive threshold to the electric stimulation had no obvious change in the control group, but those were significantly higher than before administration in the drug administration groups (P 〈 0.01), which were also obviously higher than those in the control group (t=6.211-7.237, P 〈 0.01; t=4.085-5.633, P 〈 0.05), and there was no marked difference between α-asarone group and phenobarbital sodium group (P 〉 0.05).CONCLUSION : ① As effective anticonvulsants, both acrous gramineu and α-asarone can enhance the reactivity and convulsive threshold of immature rats to electric stimulation. ② As one of the major effective components against convulsion of acrous gramineu, α-asarone is equivalent to phenobarbital sodium.
基金Supported by the Application of the Forecasting Warning System for Lightning Disaster in Yunan Plateau(YNKJXM20190733)National Natural Science Foundation of China(41775006).
文摘In this paper we have extended the semi-analytical model presented by Yashunin et al.to compute both of the lightning vertical and horizontal electric field considering the effect of nonlinear atmospheric electric parameters,and validate its accuracy by using our 2-D FDTD method.It is noted that the semi-analytical model can predict not only the lightning vertical field,but also the horizontal electric field with a satisfied accuracy in a small region with a radius ranging from 5 to 30 km at a height from 80 to 90 km above the lightning strike point.Compared with the results in the free space with a vacuum,the conducting altitude atmosphere has a relatively little effect on the radiated field component,but it has much effect on the electrostatic and induction component because their duration times are longer than the local relaxation time.For example,the induction field component in the conducting nonlinear medium decreases by about 43%,compared with that in the free space with a vacuum.The induction field is larger than the radiation field component within a radius of 25 km at a height of 80 km above the lightning strike point.Therefore,although the induction component may be likely one extra energy source(except for the radiation field)for creating the pancake shape of some elves with a luminous central part,we have to take into account the effect of nonlinear atmospheric electric parameters on the prediction of induced field component peak value that is needed for the production of elves.
基金Supported by the National Natural Science Foundation of China (51176141)the Natural Science Foundation of Tianjin(11JCZDJC22500)
文摘ERT(electrical resistance tomography) is effective method for visualization of multiphase flows,offering some advantages of rapid response and low cost,so as to explore the transient hydrodynamics.Aiming at this target,a fully programmable and reconfigurable FPGA(field programmable gate array)-based Compact PCI(peripheral component interconnect) bus linked sixteen-channel ERT system has been presented.The data acquisition system is carefully designed with function modules of signal generator module;Compact PCI transmission module and data processing module(including data sampling,filtering and demodulating).The processing module incorporates a powerful FPGA with Compact PCI bus for communication,and the measurement process management is conducted in FPGA.Image reconstruction algorithms with different speed and accuracy are also coded for this system.The system has been demonstrated in real time(1400 frames per second for 50 kHz excitation) with signal-noise-ratio above 62 dB and repeatability error below 0.7%.Static experiments have been conducted and the images manifested good resolution relative to the actual object distribution.The parallel ERT system has provided alternative experimental platform for the multiphase flow measurements by the dynamic experiments in terms of concentration and velocity.
基金Supported by National Natural Science Foundation of China (No.60532020,No.60820106002,No.60672076)Supporting Program of the Ministry of Science and Technology of China (No.2006BAI03A00)
文摘The aim of this paper is to propose a useful method for exploring regional ventilation and perfusion in the chest and also separation of pulmonary and cardiac changes.The approach is based on estimating both electrical impedance tomography(EIT) measurements and reconstructed images by means of principal component analysis(PCA).In the experiments in vivo,43 cycles of heart-beat rhythm could be detected by PCA when the volunteer held breath;9 breathing cycles and 50 heart-beat cycles could be detected by PCA ...
基金National Natural Science Foundation of China(No.61867003)Youth Science Fund Program of Lanzhou Jiaotong University(No.2019031)。
文摘To improve the operation and maintenance management level of large repairable components,such as electrical equipment,large nuclear power facilities,and high-speed electric multiple unit(EMU),and increase economic benefits,preventive maintenance has been widely used in industrial enterprises in recent years.Focusing on the problems of high maintenance costs and considerable failure hazards of EMU components in operation,we establish a state preventive maintenance model based on a stochastic differential equation.Firstly,a state degradation model of the repairable components is established in consideration of the degradation of the components and external random interference.Secondly,based on topology and martingale theory,the state degradation model is analyzed,and its simplex,stopping time,and martingale properties are proven.Finally,the monitoring data of the EMU components are taken as an example,analyzed and simulated to verify the effectiveness of the model.
基金Project supported by the National Natural Science Foundation of China(Grant No.51979125)supported by the Jiangsu Provincial Science Fund for Distinguished Young Scholars(Grant No.BK20211547)+2 种基金the Technological Innovation Team Project in Colleges and Universities of Jiangsu Province(Grant No.SKJ(2021)-1)the Open Research Subject of Key Laboratory of Fluid Machinery and Engineering(Xihua University)of Sichuan Province(Grant No.LTDL-2022007)the Graduate Research and Innovation Projects of Jiangsu Province(Grant No.KYCX23_3701).
文摘The purpose of this paper is to investigate the performance improvement mechanism of a high power vertical centrifugal pump by using numerical calculations.Therefore,a comparative study of energy losses and internal flow characteristics in the original and optimized models was carried out with special attention to the hydraulic component matching.The optimized model(model B)was obtained by optimizing the vaned diffuser and volute based on the original model(model A),mainly the diffuser inlet diameter,diffuser inlet vane angle,volute channel inlet width and volute throat area were changed.Firstly,the comparative results on performance and energy losses of two models showed that the efficiency and head of model B was significantly increased under design and part-load conditions.It is mainly due to the dramatic reduction of energy loss PL in the diffuser and volute.Then,the comparisons of PL and flow patterns in the vaned diffuser showed that the matching optimization between the model B impeller outlet flow angle and diffuser inlet vane angle resulted in a better flow pattern in both the circumferential and axial directions of the diffuser,which leads to the PL3 reduction.The meridian velocity Vm of model B was significantly increased at diffuser inlet regions and resulted in improvements of flow patterns at diffuser middle and outlet regions as well as pressure expansion capacity.Finally,the comparisons of PL and flow characteristics in the volute showed that the turbulence loss reduction in the model B volute was due to the flow pattern improvement at diffuser outlet regions which provided better flow conditions at volute inlet regions.The matching optimization between the diffuser and volute significantly reduced the turbulence loss in volute sections 1–4 and enhanced the pressure expansion capacity in sections 8–10.
文摘Innovations for electric vehicles have advanced quickly in latest decades. Large-scale business use of these vehicles is still constrained by reliability-related issues. By utilising fault tree (FT) and Monte Carlo simulation, a mathematical prototype is created that includes the reliability traits of all major electrical parts of the vehicle system, including the battery, motor, drive, controllers. The research demonstrates that by raising the component restoration rates, the vehicle’s survivability can be raised. A thorough discussion of this paradigm is provided, along with a presentation and analysis of the reliability estimations based on an electric vehicle. This research on the reliability design and maintenance of an electric vehicle can be supported by the ideas that are outlined in the paper. Additionally, the findings of this study may be helpful to those who build electric vehicle, especially when upgrading the components efficiency and planning for reliability increase.