In recent years, Z-source inverters (ZSI) have been proposed as an replacement power conversion concept which it has both voltage buck and boost abilities. In addition, ZSI doesn’t require dead-time to protection sho...In recent years, Z-source inverters (ZSI) have been proposed as an replacement power conversion concept which it has both voltage buck and boost abilities. In addition, ZSI doesn’t require dead-time to protection short circuit at two switches any of the same phase leg in the inverter bridge and to achieve optimal harmonic of current, voltage. This paper presents two different control methods (CM) for ZSI. The aim of this study to compare between two modulation methods, there are modi?ed space vector pulse width modulation method (MSVM) and the simple boost control (SBC) about the unique harmonic performance features, the total average and peak switching device power of the inverter system. In addition, this paper also analyzes about the ability exceed modulation index in linear region of two CM using MATLAB/Simulink.展开更多
This paper proposes a new concept of synthesized voltage vector to address dead-time effect issue for Finite Control Set Model Predictive Control(FCS-MPC)technique.For a voltage source inverter(VSI),dead-time is inevi...This paper proposes a new concept of synthesized voltage vector to address dead-time effect issue for Finite Control Set Model Predictive Control(FCS-MPC)technique.For a voltage source inverter(VSI),dead-time is inevitably inserted between the turn off and turn on instants of power devices to avoid short circuit phenomenon.The influence of dead-time leads to output voltage vector error of three-phase inverters.Furthermore,it will result in computing deviation in cost function,and will deteriorate the performance of the system if not properly dealt with.In this paper,the problem is clearly analyzed,and the solution to this issue is proposed by introducing a synthesized voltage vector.The proposed solution is verified by Hardware-in-the-loop(HiL)test in real time,and results validate the effectiveness of the proposed solution.展开更多
Research progresses on Cherenkov and transit-time high-power microwave(HPM)sources in National University of Defense Technology(NUDT)of China are presented.The research issues are focused on the following aspects.The ...Research progresses on Cherenkov and transit-time high-power microwave(HPM)sources in National University of Defense Technology(NUDT)of China are presented.The research issues are focused on the following aspects.The pulse-shortening phenomenon in O-type Cerenkov HPM devices is suppressed.The compact coaxial relativistic backward-wave oscillators(RBWOs)at low bands are developed.The power efficiency in M-Type HPM tubes without guiding magnetic field increased.The power capacities and power efficiencies in the triaxial klystron amplifier(TKA)and relativistic transit-time oscillator(TTO)at higher frequencies increased.In experiments,some exciting results were obtained.The X-band source generated 2 GW microwave power with a pulse duration of 110 ns in 30 Hz repetition mode.Both L-and P-band compact RBWOs generated over 2 GW microwave power with a power efficiency of over 30%.There is approximately a 75% decline of the volume compared with that of conventional RBWO under the same power capacity conditions.A 1.755 GHz MILO produced 3.1 GW microwave power with power efficiency of 10.4%.A 9.37 GHz TKA produced the 240 MW microwave power with the gain of 34 dB.A 14.3 GHz TTO produced 1 GW microwave power with power efficiency of 20%.展开更多
Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used t...Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients.展开更多
This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power osci...This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power oscillations and current distortions are inevitable.In the proposed strategy,the extended power theory is introduced to compute the power feedbacks together with the classical power theory.Based on the combination of the classical and extended power theory,the proposed strategy can achieve the sinusoidal current provision and the flexible regulation between three common targets,i.e.,constant active power,balanced current,and constant reactive power.Meanwhile,the proposed strategy is associated with a power limiter,which is capable to keep the currents under the pre-defined threshold and to compute the maximum apparent power for better utilization of the inverter capacity.With this power limiter,the rated inverter capacity is fully used for both the active and reactive power provisions under unbalanced grid faults.Using the proposed power regulation and limitation,the VSI can avoid overcurrent tripping and flexibly regulate its power under unbalanced grid faults.All the conclusions are verified by the real-time hardware-in-loop tests.展开更多
An advanced configuration for multilevel voltage source converters is proposed. The proposed converter is able to apply asymmetrical DC sources. The configuration of the proposed inverter is well designed in order to ...An advanced configuration for multilevel voltage source converters is proposed. The proposed converter is able to apply asymmetrical DC sources. The configuration of the proposed inverter is well designed in order to provide the maximum number of voltage levels in output terminals using lower number of circuit devices. The authority of the proposed inverter versus the conventional H-bridge cascaded inverter and the most recently introduced ones, is verified with a provided comparison study. The proposed inverter is able to generate the desired voltage levels using a lower number of circuit devices including power semi-conductor switches, IGBTs, diodes, related gate driver circuits of switches and DC voltage sources. As a result, the total cost and installation area are considerably reduced and the control scheme gets simpler. To confirm the feasibility of the proposed multilevel structure, both the simulation and experimental results are provided and compared which shows good agreements.展开更多
Multilevel inverter has become increasingly popular in recent years due to advantages of high power quality waveforms, low switching losses, and high-voltage capability. A novel multilevel inverter with minimum number...Multilevel inverter has become increasingly popular in recent years due to advantages of high power quality waveforms, low switching losses, and high-voltage capability. A novel multilevel inverter with minimum number of separated DC sources is presented in this paper. Three-phase output voltages of this inverter can easily be balanced because they are synthesized by using the same DC sources. A harmonic reduction method eliminating both the 5th and 7th harmonics is proposed. Finally, comparison results and spectral analysis are presented. Key words multilevel inverter - topology - DC source - harmonic reduction - spectrum Project supported by the Postdoctoral Science Foundation of Shanghai (Grant No. kO7)展开更多
A type of novel inverter power supply system for high-power twin-wire pulsed gas metal arc welding (GMAW) is presented mainly for dealing with the disadvantages of the conventional power supply for twin-wire pulsed ...A type of novel inverter power supply system for high-power twin-wire pulsed gas metal arc welding (GMAW) is presented mainly for dealing with the disadvantages of the conventional power supply for twin-wire pulsed GMA W of which the output power is generally difficult to increase due to limitations of the power of semiconductors and the power density of magnetic devices. In the power supplies for the master and slave arcs, the digital signal processor (DSP) TMS320F28335 is used to form the DSP- based synergic control system for parallel high-power pulsed GMA W, which achieves high-power output of two parallel inverters controlled by a single DSP ; master-slave communication is achieved by using e controller area network (eCAN)module of DSP, thas realizing anti-phase pulse output of high-power twin-wire pulsed GMA W and reducing the interference between twin arcs. The experiment results demonstrate that the designed inverter power supply system for high-power twin-wire pulsed GMAW can bring about high-power efficiency of welding, stable welding process and proper formation of welds.展开更多
Harmonic content of the voltage source inverters is important and must be in the allowed ranges. Different method are proposed to decrease the Total Harmonic Distortion (THD) and caused to be sinusoidal the output vol...Harmonic content of the voltage source inverters is important and must be in the allowed ranges. Different method are proposed to decrease the Total Harmonic Distortion (THD) and caused to be sinusoidal the output voltage of inverters. One of these methods is using multilevel structure. In this structure many important parameters which are effective on voltage source inverter operation that among them we can mention to modulation index (MI). Variation of modulation index can change the THD. One of the harmonic reduction methods is using multilevel structure. In this paper, a sample 5-level SHE-PWM voltage source inverter is presented and all equation and choosing switching angles for elimination desired harmonics from different order. To investigate the effective parameters on the inverter operation, a typical 5-level inverter is simulated in PSPICE software. The simulation has been done for different values of modulation and its effect on the inverter operation is evaluated.展开更多
The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid.Its high-quality operation is directly related to the output power quality of the powe...The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid.Its high-quality operation is directly related to the output power quality of the power grid.In order to further optimize the control effect of the quasi-Z source grid-connected photovoltaic inverter,a fuzzy proportional complex integral control(PCI)method is proposed for the current internal loop control.This method can eliminate the steady-state error,and has the characteristic of zero steady-state error adjustment for the AC disturbance signal of a specific frequency.The inductance-capacitance-inductance(LCL)filter is adopted in the grid-connected circuit,and the feedback capacitive current is taken as the control variable of the inner loop to form the active damping control method,which can not only effectively suppress the resonance of the LCL circuit,but also significantly inhibit the high-order harmonics in the grid-connected current.Finally,a system simulation model is built in MATLAB/Simulink to verify the superiority and effectiveness of the proposed method.展开更多
A novel topology of the current-source grid-connected inverter is proposed based on the immittance converter theory. A control strategy of sine-sine pulse width modulation (PWM) is studied. Compared with the traditi...A novel topology of the current-source grid-connected inverter is proposed based on the immittance converter theory. A control strategy of sine-sine pulse width modulation (PWM) is studied. Compared with the traditional current-source inverter, the power frequency inductors and power frequency transformer are replaced with high frequency inductors and a high frequency transformer. Thus, the proposed inverter has advantages of small volume, low cost, low total harmonic distortion (THD), low power losses, high power factor (PF) and simple control. Furthermore, grid voltage cannot influence output current of the grid-connected inverter and the current-source inverter with a high PF that approaches one has been realized. Finally, validity of the theory analysis and feasibility of the control scheme are shown by simulation and experimental results.展开更多
The paper proposes a Current Source Multilevel Inverter (CSMLI) with single rating inductor topology. Multilevel inverters are most familiar with power converter’s applications due to reduced dv/dt, di/dt stress, and...The paper proposes a Current Source Multilevel Inverter (CSMLI) with single rating inductor topology. Multilevel inverters are most familiar with power converter’s applications due to reduced dv/dt, di/dt stress, and very efficient for reducing harmonic distortion in the output voltage and output current. The proposed nine-level current source inverter has been tested under symmetrical and asymmetrical modes of operation, and their activities are compared using PI and Fuzzy PI (Proportional Integral) controllers with multicarrier PWM (Pulse Width Modulation) strategy. MATLAB/Simulink simulation has been made for the proposed converter to obtain its performance measures. Some experimental results are given to verify the presented Current Source Multilevel Inverter.展开更多
Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth le...Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth leg of the three-phase four-leg inverter so the three-phase four-leg inverter can work with unbalanced load. This paper presents a Z-source three-phase four-leg inverter which combines a Z-source network with three-phase four-leg inverter. The circuit uses simple SPWM modulation technique and the fourth bridge arm uses fully compensated control method. The inverter can maintain a symmetrical output voltage when the proposed scheme under the unbalanced load.展开更多
This paper focuses on a Z source cascaded multilevel inverter which is designed to minimize harmonics in the output voltage. A balanced dc-link peak voltage can be achieved. The power generation module is built by PV ...This paper focuses on a Z source cascaded multilevel inverter which is designed to minimize harmonics in the output voltage. A balanced dc-link peak voltage can be achieved. The power generation module is built by PV panels which are connected to Z-Source Cascade H-bridge inverter. Cascaded multilevel inverter can achieve the distributed maximum power point tracking to increase the system efficiency and achieve high voltage/high power grid tie without a transformer. This paper analyzes the different PWM switching scheme and the operating states of a ZSI module and comparison is made with different PWM and total harmonic distortion of various PWM schemes.展开更多
In this manuscript it is proposed and demonstrated that how an ANFIS (Adaptive Neuro Fuzzy Inference System) can be used in the control of a Voltage Source Inverter (VSI) connected to the grid. Volatile changes in the...In this manuscript it is proposed and demonstrated that how an ANFIS (Adaptive Neuro Fuzzy Inference System) can be used in the control of a Voltage Source Inverter (VSI) connected to the grid. Volatile changes in the gird parameters rising by its variable demands and other related issues may humiliate the efficiency with which power can be injected into the grid. The system becomes a higher order one with the filters used at the terminal of the Voltage Source Inverter (VSI) along with the parameters of the grid which change from time to time. Single time tuned mathematical controllers like the PID variants are not suitable for such applications. Considering the increased order of the system and the associated non-linearity we have to look out for intelligent controllers. An ANFIS based control is found to be promising;the development and implementation of one such are demonstrated in this paper using the MATLAB SIMULINK platform and through experimental verification using the Reduced Instruction Set Computer (RISC) Microcontroller Advanced RISC Machine (ARM) processor as the central controller for the VSI.展开更多
Asymmetric three-phase cascading Trinary-DC source Multilevel Inverter which can achieve reduced harmonics and superior root mean square (RMS) values of the output voltage is proposed. This topology can achieve cascad...Asymmetric three-phase cascading Trinary-DC source Multilevel Inverter which can achieve reduced harmonics and superior root mean square (RMS) values of the output voltage is proposed. This topology can achieve cascaded full bridge inverter operation with dissimilar (unequal) DC Source and it is fired by using variable frequency pulse with modulation technique as a switching strategy. This pulse width modulation switching strategy has a newly adopted multicarrier single reference technique. The performance parameter factors like Form Factor (FF), Crest Factor (CF), Total Harmonic Distortion (THD) and fundamental RMS output voltage (V<sub>RMS</sub>) are estimated by using proposed asymmetrical three-phase cascading multilevel inverter for several modulation indices (0.8 - 1). The research study carries with MATLAB/SIMULINK based simulation and experimental results obtained using appropriate prototype (test board) to prove the viability of the proposed concept.展开更多
This paper presents a simple approach of a topology already known in the literature, applied in active power transfer from direct current source to any alternating current voltage source, whether the utility power or ...This paper presents a simple approach of a topology already known in the literature, applied in active power transfer from direct current source to any alternating current voltage source, whether the utility power or a voltage inverter that is forming an isolated AC grid. The photovoltaic inverter works as current controlled voltage source inverter that provides a sinusoidal current to the AC grid. The inverter is insulated from the grid by a transformer. The system is discussed and modeled. Simulation results of this application are presented and experimental results validate this topology.展开更多
3.SWITCHING ANGLES If the nominal capacitor voltage is chosen as Vdc/2, then one can compute the switching anglesθ1,θ2,andθ3.Following the development,the Fourier series expan- sion of the(staircase)output voltage ...3.SWITCHING ANGLES If the nominal capacitor voltage is chosen as Vdc/2, then one can compute the switching anglesθ1,θ2,andθ3.Following the development,the Fourier series expan- sion of the(staircase)output voltage waveform of the multilevel inverter as shown in Fig.2(a)展开更多
This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (f...This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (finite set-model predictive control) strategy for a three-phase VSI for RES (renewable energy systems) applications is implemented. The renewable energy systems model is used in this paper to investigate the system performance when power is supplied to resistive-inductive load. With three different cases, the evaluation of the system is done. Firstly, the robustness of control strategy under variable DC-Link is done in terms of the THD (total harmonic distortion). Secondly, with one prediction step, the system performance is tested using different sampling time, and lastly, the dynamic response of the system with step change in the amplitude of the reference is investigated. The simulations and result analyses are carried out using Matlab/Simulink to test the effectiveness and robustness of FS-MPC for two-level VSI with AC filter for resistive-inductive load supplied by a renewable energy system.展开更多
文摘In recent years, Z-source inverters (ZSI) have been proposed as an replacement power conversion concept which it has both voltage buck and boost abilities. In addition, ZSI doesn’t require dead-time to protection short circuit at two switches any of the same phase leg in the inverter bridge and to achieve optimal harmonic of current, voltage. This paper presents two different control methods (CM) for ZSI. The aim of this study to compare between two modulation methods, there are modi?ed space vector pulse width modulation method (MSVM) and the simple boost control (SBC) about the unique harmonic performance features, the total average and peak switching device power of the inverter system. In addition, this paper also analyzes about the ability exceed modulation index in linear region of two CM using MATLAB/Simulink.
文摘This paper proposes a new concept of synthesized voltage vector to address dead-time effect issue for Finite Control Set Model Predictive Control(FCS-MPC)technique.For a voltage source inverter(VSI),dead-time is inevitably inserted between the turn off and turn on instants of power devices to avoid short circuit phenomenon.The influence of dead-time leads to output voltage vector error of three-phase inverters.Furthermore,it will result in computing deviation in cost function,and will deteriorate the performance of the system if not properly dealt with.In this paper,the problem is clearly analyzed,and the solution to this issue is proposed by introducing a synthesized voltage vector.The proposed solution is verified by Hardware-in-the-loop(HiL)test in real time,and results validate the effectiveness of the proposed solution.
基金supported by the National Natural Science Funds Fund of China under Grant No.11505288Provincial Natural Science Foundation of Hunanscientific effort project of NUDT.
文摘Research progresses on Cherenkov and transit-time high-power microwave(HPM)sources in National University of Defense Technology(NUDT)of China are presented.The research issues are focused on the following aspects.The pulse-shortening phenomenon in O-type Cerenkov HPM devices is suppressed.The compact coaxial relativistic backward-wave oscillators(RBWOs)at low bands are developed.The power efficiency in M-Type HPM tubes without guiding magnetic field increased.The power capacities and power efficiencies in the triaxial klystron amplifier(TKA)and relativistic transit-time oscillator(TTO)at higher frequencies increased.In experiments,some exciting results were obtained.The X-band source generated 2 GW microwave power with a pulse duration of 110 ns in 30 Hz repetition mode.Both L-and P-band compact RBWOs generated over 2 GW microwave power with a power efficiency of over 30%.There is approximately a 75% decline of the volume compared with that of conventional RBWO under the same power capacity conditions.A 1.755 GHz MILO produced 3.1 GW microwave power with power efficiency of 10.4%.A 9.37 GHz TKA produced the 240 MW microwave power with the gain of 34 dB.A 14.3 GHz TTO produced 1 GW microwave power with power efficiency of 20%.
文摘Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients.
基金This work is supported by the National Key Research and Development Program of China under Project 2021YFB2601600。
文摘This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power oscillations and current distortions are inevitable.In the proposed strategy,the extended power theory is introduced to compute the power feedbacks together with the classical power theory.Based on the combination of the classical and extended power theory,the proposed strategy can achieve the sinusoidal current provision and the flexible regulation between three common targets,i.e.,constant active power,balanced current,and constant reactive power.Meanwhile,the proposed strategy is associated with a power limiter,which is capable to keep the currents under the pre-defined threshold and to compute the maximum apparent power for better utilization of the inverter capacity.With this power limiter,the rated inverter capacity is fully used for both the active and reactive power provisions under unbalanced grid faults.Using the proposed power regulation and limitation,the VSI can avoid overcurrent tripping and flexibly regulate its power under unbalanced grid faults.All the conclusions are verified by the real-time hardware-in-loop tests.
文摘An advanced configuration for multilevel voltage source converters is proposed. The proposed converter is able to apply asymmetrical DC sources. The configuration of the proposed inverter is well designed in order to provide the maximum number of voltage levels in output terminals using lower number of circuit devices. The authority of the proposed inverter versus the conventional H-bridge cascaded inverter and the most recently introduced ones, is verified with a provided comparison study. The proposed inverter is able to generate the desired voltage levels using a lower number of circuit devices including power semi-conductor switches, IGBTs, diodes, related gate driver circuits of switches and DC voltage sources. As a result, the total cost and installation area are considerably reduced and the control scheme gets simpler. To confirm the feasibility of the proposed multilevel structure, both the simulation and experimental results are provided and compared which shows good agreements.
文摘Multilevel inverter has become increasingly popular in recent years due to advantages of high power quality waveforms, low switching losses, and high-voltage capability. A novel multilevel inverter with minimum number of separated DC sources is presented in this paper. Three-phase output voltages of this inverter can easily be balanced because they are synthesized by using the same DC sources. A harmonic reduction method eliminating both the 5th and 7th harmonics is proposed. Finally, comparison results and spectral analysis are presented. Key words multilevel inverter - topology - DC source - harmonic reduction - spectrum Project supported by the Postdoctoral Science Foundation of Shanghai (Grant No. kO7)
基金Supported by National Natural Science Foundation of China(No.51205136)Ph.D. Programs Foundation of the Ministry of Education of China(No.20100172120003)+1 种基金Competitive Allocation Project Special Fund of Guangdong Province Chinese Academy of Sciences Comprehensive Strategic Cooperation(No.2013B091500082)The Fundamental Research Funds for the Central Universities(Key Program)(No.2015ZZ084)
文摘A type of novel inverter power supply system for high-power twin-wire pulsed gas metal arc welding (GMAW) is presented mainly for dealing with the disadvantages of the conventional power supply for twin-wire pulsed GMA W of which the output power is generally difficult to increase due to limitations of the power of semiconductors and the power density of magnetic devices. In the power supplies for the master and slave arcs, the digital signal processor (DSP) TMS320F28335 is used to form the DSP- based synergic control system for parallel high-power pulsed GMA W, which achieves high-power output of two parallel inverters controlled by a single DSP ; master-slave communication is achieved by using e controller area network (eCAN)module of DSP, thas realizing anti-phase pulse output of high-power twin-wire pulsed GMA W and reducing the interference between twin arcs. The experiment results demonstrate that the designed inverter power supply system for high-power twin-wire pulsed GMAW can bring about high-power efficiency of welding, stable welding process and proper formation of welds.
文摘Harmonic content of the voltage source inverters is important and must be in the allowed ranges. Different method are proposed to decrease the Total Harmonic Distortion (THD) and caused to be sinusoidal the output voltage of inverters. One of these methods is using multilevel structure. In this structure many important parameters which are effective on voltage source inverter operation that among them we can mention to modulation index (MI). Variation of modulation index can change the THD. One of the harmonic reduction methods is using multilevel structure. In this paper, a sample 5-level SHE-PWM voltage source inverter is presented and all equation and choosing switching angles for elimination desired harmonics from different order. To investigate the effective parameters on the inverter operation, a typical 5-level inverter is simulated in PSPICE software. The simulation has been done for different values of modulation and its effect on the inverter operation is evaluated.
基金the Foundation of a Hundred Youth Talents Training Program of Lanzhou Jiaotong University under Grant No.2018-103the Colleges and University Scientific Research Funds of Gansu Province under Grant No.2017A-026。
文摘The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid.Its high-quality operation is directly related to the output power quality of the power grid.In order to further optimize the control effect of the quasi-Z source grid-connected photovoltaic inverter,a fuzzy proportional complex integral control(PCI)method is proposed for the current internal loop control.This method can eliminate the steady-state error,and has the characteristic of zero steady-state error adjustment for the AC disturbance signal of a specific frequency.The inductance-capacitance-inductance(LCL)filter is adopted in the grid-connected circuit,and the feedback capacitive current is taken as the control variable of the inner loop to form the active damping control method,which can not only effectively suppress the resonance of the LCL circuit,but also significantly inhibit the high-order harmonics in the grid-connected current.Finally,a system simulation model is built in MATLAB/Simulink to verify the superiority and effectiveness of the proposed method.
基金supported by the Shanghai Leading Academic Discipline Project (Grant No.T0103)
文摘A novel topology of the current-source grid-connected inverter is proposed based on the immittance converter theory. A control strategy of sine-sine pulse width modulation (PWM) is studied. Compared with the traditional current-source inverter, the power frequency inductors and power frequency transformer are replaced with high frequency inductors and a high frequency transformer. Thus, the proposed inverter has advantages of small volume, low cost, low total harmonic distortion (THD), low power losses, high power factor (PF) and simple control. Furthermore, grid voltage cannot influence output current of the grid-connected inverter and the current-source inverter with a high PF that approaches one has been realized. Finally, validity of the theory analysis and feasibility of the control scheme are shown by simulation and experimental results.
文摘The paper proposes a Current Source Multilevel Inverter (CSMLI) with single rating inductor topology. Multilevel inverters are most familiar with power converter’s applications due to reduced dv/dt, di/dt stress, and very efficient for reducing harmonic distortion in the output voltage and output current. The proposed nine-level current source inverter has been tested under symmetrical and asymmetrical modes of operation, and their activities are compared using PI and Fuzzy PI (Proportional Integral) controllers with multicarrier PWM (Pulse Width Modulation) strategy. MATLAB/Simulink simulation has been made for the proposed converter to obtain its performance measures. Some experimental results are given to verify the presented Current Source Multilevel Inverter.
文摘Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth leg of the three-phase four-leg inverter so the three-phase four-leg inverter can work with unbalanced load. This paper presents a Z-source three-phase four-leg inverter which combines a Z-source network with three-phase four-leg inverter. The circuit uses simple SPWM modulation technique and the fourth bridge arm uses fully compensated control method. The inverter can maintain a symmetrical output voltage when the proposed scheme under the unbalanced load.
文摘This paper focuses on a Z source cascaded multilevel inverter which is designed to minimize harmonics in the output voltage. A balanced dc-link peak voltage can be achieved. The power generation module is built by PV panels which are connected to Z-Source Cascade H-bridge inverter. Cascaded multilevel inverter can achieve the distributed maximum power point tracking to increase the system efficiency and achieve high voltage/high power grid tie without a transformer. This paper analyzes the different PWM switching scheme and the operating states of a ZSI module and comparison is made with different PWM and total harmonic distortion of various PWM schemes.
文摘In this manuscript it is proposed and demonstrated that how an ANFIS (Adaptive Neuro Fuzzy Inference System) can be used in the control of a Voltage Source Inverter (VSI) connected to the grid. Volatile changes in the gird parameters rising by its variable demands and other related issues may humiliate the efficiency with which power can be injected into the grid. The system becomes a higher order one with the filters used at the terminal of the Voltage Source Inverter (VSI) along with the parameters of the grid which change from time to time. Single time tuned mathematical controllers like the PID variants are not suitable for such applications. Considering the increased order of the system and the associated non-linearity we have to look out for intelligent controllers. An ANFIS based control is found to be promising;the development and implementation of one such are demonstrated in this paper using the MATLAB SIMULINK platform and through experimental verification using the Reduced Instruction Set Computer (RISC) Microcontroller Advanced RISC Machine (ARM) processor as the central controller for the VSI.
文摘Asymmetric three-phase cascading Trinary-DC source Multilevel Inverter which can achieve reduced harmonics and superior root mean square (RMS) values of the output voltage is proposed. This topology can achieve cascaded full bridge inverter operation with dissimilar (unequal) DC Source and it is fired by using variable frequency pulse with modulation technique as a switching strategy. This pulse width modulation switching strategy has a newly adopted multicarrier single reference technique. The performance parameter factors like Form Factor (FF), Crest Factor (CF), Total Harmonic Distortion (THD) and fundamental RMS output voltage (V<sub>RMS</sub>) are estimated by using proposed asymmetrical three-phase cascading multilevel inverter for several modulation indices (0.8 - 1). The research study carries with MATLAB/SIMULINK based simulation and experimental results obtained using appropriate prototype (test board) to prove the viability of the proposed concept.
文摘This paper presents a simple approach of a topology already known in the literature, applied in active power transfer from direct current source to any alternating current voltage source, whether the utility power or a voltage inverter that is forming an isolated AC grid. The photovoltaic inverter works as current controlled voltage source inverter that provides a sinusoidal current to the AC grid. The inverter is insulated from the grid by a transformer. The system is discussed and modeled. Simulation results of this application are presented and experimental results validate this topology.
文摘3.SWITCHING ANGLES If the nominal capacitor voltage is chosen as Vdc/2, then one can compute the switching anglesθ1,θ2,andθ3.Following the development,the Fourier series expan- sion of the(staircase)output voltage waveform of the multilevel inverter as shown in Fig.2(a)
文摘This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (finite set-model predictive control) strategy for a three-phase VSI for RES (renewable energy systems) applications is implemented. The renewable energy systems model is used in this paper to investigate the system performance when power is supplied to resistive-inductive load. With three different cases, the evaluation of the system is done. Firstly, the robustness of control strategy under variable DC-Link is done in terms of the THD (total harmonic distortion). Secondly, with one prediction step, the system performance is tested using different sampling time, and lastly, the dynamic response of the system with step change in the amplitude of the reference is investigated. The simulations and result analyses are carried out using Matlab/Simulink to test the effectiveness and robustness of FS-MPC for two-level VSI with AC filter for resistive-inductive load supplied by a renewable energy system.