Calculation of Mass Concrete Temperature Containing Cooling Water Pipe Based on Substructure and Iteration Algorithm
1
作者 Heng Zhang Chao Su +2 位作者 Zhizhong Song Zhenzhong Shen Huiguang Lei 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第1期813-826,共14页
Mathematical physics equations are often utilized to describe physical phenomena in various fields of science and engineering.One such equation is the Fourier equation,which is a commonly used and effective method for... Mathematical physics equations are often utilized to describe physical phenomena in various fields of science and engineering.One such equation is the Fourier equation,which is a commonly used and effective method for evaluating the effectiveness of temperature control measures for mass concrete.One important measure for temperature control in mass concrete is the use of cooling water pipes.However,the mismatch of grids between large-scale concrete models and small-scale cooling pipe models can result in a significant waste of calculation time when using the finite element method.Moreover,the temperature of the water in the cooling pipe needs to be iteratively calculated during the thermal transfer process.The substructure method can effectively solve this problem,and it has been validated by scholars.The Abaqus/Python secondary development technology provides engineers with enough flexibility to combine the substructure method with an iteration algorithm,which enables the creation of a parametric modeling calculation for cooling water pipes.This paper proposes such a method,which involves iterating the water pipe boundary and establishing the water pipe unit substructure to numerically simulate the concrete temperature field that contains a cooling water pipe.To verify the feasibility and accuracy of the proposed method,two classic numerical examples were analyzed.The results showed that this method has good applicability in cooling pipe calculations.When the value of the iteration parameterαis 0.4,the boundary temperature of the cooling water pipes can meet the accuracy requirements after 4∼5 iterations,effectively improving the computational efficiency.Overall,this approach provides a useful tool for engineers to analyze the temperature control measures accurately and efficiently for mass concrete,such as cooling water pipes,using Abaqus/Python secondary development. 展开更多
关键词 Fourier equation cooling water pipe mass concrete iteration algorithm
下载PDF
Numerical Simulation Analysis of the Transformer Fire Extinguishing Process with a High-Pressure Water Mist System under Different Conditions 被引量:1
2
作者 Haowei Yao Youxin Li +7 位作者 Kefeng Lv Dong Wang Jinguang Zhang Zhenyu Zhan Zhenyu Wang Huaitao Song Xiaoge Wei Hengjie Qin 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第7期733-747,共15页
To thoroughly study the extinguishing effect of a high-pressure water mist fire extinguishing system when a transformer fire occurs,a 3D experimental model of a transformer is established in this work by employing Fir... To thoroughly study the extinguishing effect of a high-pressure water mist fire extinguishing system when a transformer fire occurs,a 3D experimental model of a transformer is established in this work by employing Fire Dynamics Simulator(FDS)software.More specifically,by setting different parameters,the process of the highpressure water mist fire extinguishing system with the presence of both diverse ambient temperatures and water mist sprinkler laying conditions is simulated.In addition,the fire extinguishing effect of the employed high-pressure water mist system with the implementation of different strategies is systematically analyzed.The extracted results show that a fire source farther away fromthe centerline leads to a lower local temperature distribution.In addition,as the ambient temperature increases,the temperature above the fire source decreases,while the temperature and the concentrationof theupperflue gas layer bothdecrease.Interestingly,after thehigh-pressurewatermist sprinkler begins to operate,both the temperature distribution above the fire source and the concentration of the flue gas decrease,which indicates that the high-pressure water mist system plays the role of cooling and dust removal.By comparing various sprinkler laying methods,it is found that the lower sprinkler height has a better effect on the temperature above the fire source,the temperature of the upper flue gas layer,and the concentration of the flue gas.Moreover,when the sprinkler is spread over thewhole transformer,the cooling effect on both the temperature above the fire source and the temperature of the upper flue gas layer is good,whereas the change in the concentration of the flue gas above the fire source is not obvious compared to the case where the sprinkler is not fully spread. 展开更多
关键词 Transformer fire high-pressure water mist TEMPERATURE flue gas concentration
下载PDF
Experimental Study on the Resistance and Splash Performances of Water Collecting Devices for Mechanical Draft Cooling Towers
3
作者 Guoqing Long Guogang Zhang +3 位作者 Qi Zhang Cuilin Zhao Suoying He Fengzhong Sun 《Fluid Dynamics & Materials Processing》 EI 2023年第7期1789-1801,共13页
In recent years,water collecting systems,with the associated advantages of energy saving and noise reduction,have become the foundation for the development of a scheme to optimize the structure of cooling towers.To ex... In recent years,water collecting systems,with the associated advantages of energy saving and noise reduction,have become the foundation for the development of a scheme to optimize the structure of cooling towers.To explore the feasibility of this approach for mechanical draft cooling towers,a small-scale experimental device has been built to study the resistance and splash performances of three U-type water collecting devices(WCDs)for different water flow rates and wind speeds.The experimental results show that within the considered ranges of wind speed and water flow rate,the pressure drop of the different WCDs can vary significantly.The resistance and local splash performances can also be remarkably different.Some recommendations about the most suitable system are provided.Moreover,a regression analysis of the experimental data is conducted,and the resulting fitting formulas for resistance and splash performance of WCD are reported. 展开更多
关键词 Mechanical draft cooling towers water collecting device resistance performance splash performance fitting formulas
下载PDF
Design and analysis of a high loss density motor cooling system with water cold plates
4
作者 Xin Zhao Haojie Cui +2 位作者 Yun Teng Zhe Chen Guangwei Liu 《Global Energy Interconnection》 EI CSCD 2023年第3期343-354,共12页
Aiming at reducing the difficulty of cooling the interior of high-density motors,this study proposed the placement of a water cold plate cooling structure between the axial laminations of the motor stator.The effect o... Aiming at reducing the difficulty of cooling the interior of high-density motors,this study proposed the placement of a water cold plate cooling structure between the axial laminations of the motor stator.The effect of the cooling water flow,thickness of the plate,and motor loss density on the cooling effect of the water cold plate were studied.To compare the cooling performance of water cold plate and outer spiral water jacket cooling structures,a high-speed permanent magnet motor with a high loss density was used to establish two motor models with the two cooling structures.Consequently,the cooling effects of the two models were analyzed using the finite element method under the same loss density,coolant flow,and main dimensions.The results were as follows.(1)The maximum and average temperatures of the water cold plate structure were reduced by 25.5%and 30.5%,respectively,compared to that of the outer spiral water jacket motor;(2)Compared with the outer spiral water jacket structure,the water cold plate structure can reduce the overall mass and volume of the motor.Considering a 100 kW high-speed permanent magnet motor as an example,a water cold plate cooling system was designed,and the temperature distribution is analyzed,with the result indicating that the cooling structure satisfied the cooling requirements of the high loss density motor. 展开更多
关键词 cooling system design High loss density motor water cold plate Temperature field analysis
下载PDF
Application of high-pressure water jet technology and the theory of rock burst control in roadway 被引量:19
5
作者 Yang Zengqiang Dou Linming +3 位作者 Liu Chang Xu Mengtang Lei Zhen Yao Yahu 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2016年第5期929-935,共7页
This paper puts forward using high-pressure water jet technology to control rock burst in roadway, and analyzes the theory of controlling rock burst in roadway by the weak structure zone model. The weak structure zone... This paper puts forward using high-pressure water jet technology to control rock burst in roadway, and analyzes the theory of controlling rock burst in roadway by the weak structure zone model. The weak structure zone is formed by using high-pressure water jet to cut the coal wall in a continuous and rotational way. In order to study the influence law of weak structure zone in surrounding rock, this paper numerically analyzed the influence law of weak structure zone, and the disturbance law of coal wall and floor under dynamic and static combined load. The results show that when the distance between high-pressure water jet drillings is 3 m and the diameter of drilling is 300 mm, continuous stress superposition zone can be formed. The weak structure zone can transfer and reduce the concentrated static load in surrounding rock, and then form distressed zone. The longer the high-pressure water jet drilling is, the larger the distressed zone is. The stress change and displacement change of non-distressed zone in coal wall and floor are significantly greater than that of distressed zone under dynamic and static combined load. And it shows that the distressed zone can effectively control rock burst in roadway under dynamic and static combined load. High-pressure water jet technology was applied in the haulage gate of 250203 working face in Yanbei Coal Mine, and had gained good effect. The study conclusions provide theoretical foundation and a new guidance for controlling rock burst in roadway. 展开更多
关键词 high-pressure water jet technology Rock burst Weak structure zone Dynamic and static combined load
下载PDF
In situ experimental study on TBM excavation with high-pressure water-jet-assisted rock breaking 被引量:9
6
作者 ZHANG Jin-liang YANG Feng-wei +2 位作者 CAO Zhi-guo XIA Yi-min LI Yong-chang 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第12期4066-4077,共12页
China’s first high-pressure hydraulically coupled rock-breaking tunnel boring machine(TBM) was designed to overcome the rock breaking problems of TBM in super-hard rock geology, where high-pressure water jet system i... China’s first high-pressure hydraulically coupled rock-breaking tunnel boring machine(TBM) was designed to overcome the rock breaking problems of TBM in super-hard rock geology, where high-pressure water jet system is configured, including high-flow pump sets, high-pressure rotary joint and high-pressure water jet injection device. In order to investigate the rock breaking performance of high-pressure water-jet-assisted TBM, in situ excavation tests were carried out at the Wan’anxi Water Diversion Project in Longyan, Fujian Province, China, under different water jet pressure and rotational speed. The rock-breaking performance of TBM was analyzed including penetration, cutterhead load, advance rate and field penetration index. The test results show that the adoption of high-pressure water-jet-assisted rock breaking technology can improve the boreability of rock mass, where the TBM penetration increases by 64% under the water jet pressure of 270 MPa. In addition, with the increase of the water jet pressure, the TBM penetration increases and the field penetration index decreases. The auxiliary rock-breaking effect of high-pressure water jet decreases with the increase of cutterhead rotational speed. In the case of the in situ tunneling test parameters of this study, the advance rate is the maximum when the pressure of the high-pressure water jet is 270 MPa and the cutterhead rotational speed is 6 r/min. The technical superiority of high-pressure water-jet-assisted rock breaking technology is highlighted and it provides guidance for the excavation parameter selection of high-pressure hydraulically coupled rock-breaking TBM. 展开更多
关键词 tunnel boring machine high-pressure water jet PENETRATION advance rate field penetration index
下载PDF
Corrosion Inhibition by Co-Immobilized Lysozyme and Lipase in Circulating Cooling Water System 被引量:3
7
作者 Liu Fang Lü Yucui +3 位作者 Jiang Guofei Chen Xiaorui Sun Juan Zhao Chaocheng 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2017年第2期21-32,共12页
The corrosion inhibition performance of co-immobilized lysozyme and lipase was investigated in a recirculating cooling water system. Four methods were carried out in co-immobilization, and the operating parameters wer... The corrosion inhibition performance of co-immobilized lysozyme and lipase was investigated in a recirculating cooling water system. Four methods were carried out in co-immobilization, and the operating parameters were optimized by using the respond surface methodology(RSM). The corrosion inhibition performance of co-immobilized lipase and lysozyme was evaluated by weight loss measurements and electrochemical measurements. The results revealed that the optimal co-immobilization method should be the sequential immobilization of lysozyme and then lipase. The inhibition efficiency was 86.10% under the optimal co-immobilized conditions. Electrochemical data showed that co-immobilized lysozyme and lipase was a mixed-type inhibitor and the corrosion inhibition efficiency was 81%. 展开更多
关键词 CIRCULATING cooling water CO-IMMOBILIZATION LYSOZYME LIPASE corrosion INHIBITION
下载PDF
Effect of temperature, chloride ions and sulfide ions on the electrochemical properties of 316L stainless steel in simulated cooling water 被引量:3
8
作者 李金波 翟文 +1 位作者 郑茂盛 朱杰武 《Journal of Pharmaceutical Analysis》 SCIE CAS 2008年第1期33-37,60,共6页
The influence of temperature, chloride ions and sulfide ions on the anticorrosion behavior of 316L stainless steel in simulated cooling water was studied by electrochemical impedance spectroscopy and anodic polarizati... The influence of temperature, chloride ions and sulfide ions on the anticorrosion behavior of 316L stainless steel in simulated cooling water was studied by electrochemical impedance spectroscopy and anodic polarization curves. The results show that the film resistance increases with the solution temperature but decreases after 8 days’ immersion, which indicates that the film formed at higher temperature has inferior anticorrosion behavior; Chloride ions and sulfide ions have remarkable effects on the electrochemical property of 316L stainless steel in simulated cooling water and the pitting potential declines with the concentration of chloride ions; the passivation current has no obvious effect; the rise of the concentration of sulfide ions obviously increases the passivation current, but the pitting potential changes little, which indicates that the two types of ions may have different effects on destructing passive film of stainless steel. The critical concentration of chloride ions causing anodic potential curve’s change in simulated cooling water is 250 mg/L for 316 L stainless. The effect of sulfide ions on the corrosion resistance behavior of stainless steel is increasing the passivation current density Ip. The addition of 6 mg/L sulfide ions to the solution makes Ip of 316 L increase by 0.5 times. 展开更多
关键词 stainless steel TEMPERATURE chloride ions sulfide ions simulated cooling water
下载PDF
Application of a water cooling treatment and its effect on coal-based reduction of high-chromium vanadium and titanium iron ore 被引量:2
9
作者 Song-tao Yang Mi Zhou +3 位作者 Tao Jiang Shan-fei Guan Wei-jun Zhang Xiang-xin Xue 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2016年第12期1353-1359,共7页
A water cooling treatment was applied in the coal-based reduction of high-chromium vanadium and titanium (V-Ti-Cr) iron ore from the Hongge region of Panzhihua, China. Its effects on the metallization ratio (η), ... A water cooling treatment was applied in the coal-based reduction of high-chromium vanadium and titanium (V-Ti-Cr) iron ore from the Hongge region of Panzhihua, China. Its effects on the metallization ratio (η), S removal ratio (Rs), and P removal ratio (Rp) were studied and analyzed on the basis of chemical composition determined via inductively coupled plasma optical emission spectroscopy. The metallic iron particle size and the element distribution of Fe, V, Cr, and Ti in a reduced briquette after water cooling treatment at 1350℃ were determined and observed via scanning electron microscopy. The results show that the water cooling treatment improved the η, Rs, and Rp in the coal-based reduction of V-Ti-Cr iron ore compared to those obtained with a furnace cooling treatment. Meanwhile, the particle size of metallic iron obtained via the water cooling treatment was smaller than that of metallic iron obtained via the furnace cooling treatment; however, the particle size reached 70 μm at 1350℃, which is substantially larger than the minimum particle size required (20 μm) for magnetic separation. Therefore, the water cooling treatment described in this work is a good method for improving the quality of metallic iron in coal-based reduction and it could be applied in the coal-based reduction of V-Ti-Cr iron ore followed by magnetic separation. 展开更多
关键词 MAGNETITE ore reduction water cooling METALLIZATION magnetic separation
下载PDF
Application of Cooling Water in Controlled Runout Table Cooling on Hot Strip Mill 被引量:2
10
作者 LIUZheng-dong IVSamarasekera 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2004年第3期15-23,共9页
The controlled runout table cooling is essential in determining the final mechanical properties and flatness of steel strip.The heat of a hot steel strip is mainly extracted by cooling water during runout.In order to ... The controlled runout table cooling is essential in determining the final mechanical properties and flatness of steel strip.The heat of a hot steel strip is mainly extracted by cooling water during runout.In order to study the heat transfer by water jet impingement boiling during runout,apilot facility was constructed at the University of British Columbia.On this pilot facility,the water jet impingement tests were carried out under various cooling conditions to investigate the effect of processing parameters,such as cooling water temperature,water jet impingement velocity,initial strip temperature,water flow rate,water nozzle diameter and array of water nozzles,on the heat transfer of heated strip.The results obtained contribute to the optimization of cooling water during runout. 展开更多
关键词 cooling water controlled runout table hot strip mill
下载PDF
Strength-ductility balance of AZ31 magnesium alloy via accumulated extrusion bonding combined with two-stage artificial cooling Author links open overlay panel
11
作者 Tingzhuang Han Guangsheng Huang +3 位作者 Heng Li Lifei Wang Hua Zhang Fusheng Pan 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2023年第5期1549-1555,共7页
AZ31 Mg alloy with heterogeneous bimodal grain structure(smaller grain size of 5-20µm and coarser grain size of 100-200µm)was subjected to accumulated extrusion bonding(AEB)at 250℃combined with two-stage ar... AZ31 Mg alloy with heterogeneous bimodal grain structure(smaller grain size of 5-20µm and coarser grain size of 100-200µm)was subjected to accumulated extrusion bonding(AEB)at 250℃combined with two-stage artificial cooling in this work,viz.local water cooling and artificial cooling.The microstructure developed consecutively as a result of discontinuous dynamic recrystallization(DDRX)for the AEBed samples.{10-12}tensile twinning also played an important role for the AEB with local water cooling at the initial extrusion stage in the container.Local water cooling could further reduce the DRXed grain size to~2.1µm comparing that without water cooling.And the grain growth rate was reduced by artificial cooling out of extrusion die.Under the combination of two-stage cooling,the fine DRXed grains at sizing band were almost retained with average grain size of~2.3µm after the sheet out of extrusion die,and the unDRXed grains with high residual dislocation density accumulation were also reserved.The tensile tests results indicated that a good strength-ductility balance with a high ultimate tensile strength(319 MPa vs.412 MPa)and fracture elongation(19.9%vs.30.3%)were obtained.The strength enhancement was mainly owing to the grain refinement and local residual plastic strain reserved by the artificial cooling.The excellent ductility originated from fine DRXed microstructure and ED-tilt double peak texture. 展开更多
关键词 Magnesium alloy Accumulated extrusion bonding Local water cooling Artificial cooling Microstructure Mechanical properties
下载PDF
Optimization of circulating cooling water systems based on chance constrained programming 被引量:3
12
作者 Bo Liu Yufei Wang Xiao Feng 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第12期167-178,共12页
Recent research on deterministic methods for circulating cooling water systems optimization has been well developed. However, the actual operating conditions of the system are mostly variable, so the system obtained u... Recent research on deterministic methods for circulating cooling water systems optimization has been well developed. However, the actual operating conditions of the system are mostly variable, so the system obtained under deterministic conditions may not be stable and economical. This paper studies the optimization of circulating cooling water systems under uncertain circumstance. To improve the reliability of the system and reduce the water and energy consumption, the influence of different uncertain parameters is taken into consideration. The chance constrained programming method is used to build a model under uncertain conditions, where the confidence level indicates the degree of constraint violation. Probability distribution functions are used to describe the form of uncertain parameters. The objective is to minimize the total cost and obtain the optimal cooling network configuration simultaneously.An algorithm based on Monte Carlo method is proposed, and GAMS software is used to solve the mixed integer nonlinear programming model. A case is optimized to verify the validity of the model. Compared with the deterministic optimization method, the results show that when considering the different types of uncertain parameters, a system with better economy and reliability can be obtained(total cost can be reduced at least 2%). 展开更多
关键词 Circulating cooling water system UNCERTAINTY Chance constrained programming DESIGN OPTIMIZATION SIMULATION
下载PDF
Transient Heat Transfer Study of Direct Contact Condensation of Steam in Spray Cooling Water 被引量:2
13
作者 Yiping Wang Yunfa Hu +1 位作者 Qunwu Huang Yong Cui 《Transactions of Tianjin University》 EI CAS 2018年第2期131-143,共13页
We conducted a transient experimental investigation of steam–water direct contact condensation in the absence of noncondensible gas in a laboratory-scale column with the inner diameter of 325 mm and the height of 104... We conducted a transient experimental investigation of steam–water direct contact condensation in the absence of noncondensible gas in a laboratory-scale column with the inner diameter of 325 mm and the height of 1045 mm. We applied a new analysis method for the steam state equation to analyze the molar quantity change in steam over the course of the experiment and determined the transient steam variation. We also investigated the influence of flow rates and temperatures ofcooling water on the efficiency ofsteam condensation. Our experimental results show that appropriate increasing of the cooling water flow rate can significantly accelerate the steam condensation. We achieved a rapid increase in the total volumetric heat transfer coefficient by increasing the flow rate of cooling water, which indicated a higher thermal convection between the steam and the cooling water with higher flow rates. We found that the temperature ofcooling water did not play an important role on steam condensation. This method was confirmed to be effective for rapid recovering ofsteam. 展开更多
关键词 Direct contact CONDENSATION STEAM SPRAY cooling water Transient HEAT TRANSFER performance STEAM state equation VOLUMETRIC HEAT TRANSFER coeffi cient
下载PDF
EVOLUTION OF LIQUID WATER CONTENT IN A SEA FOG CONTROLLED BY A HIGH-PRESSURE PATTERN 被引量:3
14
作者 李晓娜 黄健 +2 位作者 申双和 刘寿东 吕卫华 《Journal of Tropical Meteorology》 SCIE 2010年第4期409-416,共8页
On March 16–17, 2008, a sea fog occurred in Dianbai in the west of Guangdong Province and was accompanied by a high-pressure synoptic system. Using comprehensive observation datasets, this study analyzes the evolutio... On March 16–17, 2008, a sea fog occurred in Dianbai in the west of Guangdong Province and was accompanied by a high-pressure synoptic system. Using comprehensive observation datasets, this study analyzes the evolution of liquid water content during this sea fog and investigates the relationships between liquid water content and the average diameters and count densities of fog droplets, air temperature, wind speed and turbulence exchanges. The main results are presented as follows. (1) The sea fog showed a quasi-periodic oscillation characteristic, i.e., it developed, disappeared and then developed again. (2) During the sea fog, the number of fog droplets changed significantly while the changes in average diameter of the fog droplets were relatively small. The development and disappearance of the sea fog correlated significantly with the fog droplet numbers. (3) The air-cooling mechanism played a significant role in sea fog formation and development. However, the influences of this mechanism were not evident during fog persistence. (4) During sea fog formation, weak turbulence exchanges were helpful for fog formation. During sea fog development and persistence, liquid water content increased when turbulence exchanges weakened, and vice versa. The changes in turbulence exchanges were closely related to the quasi-periodic oscillations observed in sea fog presence. 展开更多
关键词 high-pressure pattern sea fog liquid water content count density of fog droplets average diameter of fog droplets turbulence exchanges
下载PDF
MIC in Circulating Cooling Water System 被引量:1
15
作者 Ping Xu Zhaoyi Xu +2 位作者 Jin Wang Yajun Zhang Li Zhang 《Journal of Water Resource and Protection》 2012年第4期203-206,共4页
MIC is one of the main problems of circulating cooling water system. The direct economic loss by MIC is about 300 to 500 billion dollars. It is good to understand MIC in order to control MIC. Source and species of mic... MIC is one of the main problems of circulating cooling water system. The direct economic loss by MIC is about 300 to 500 billion dollars. It is good to understand MIC in order to control MIC. Source and species of microorganisms was introduced firstly. There are three kinds of microorganisms in the system, including bacteria, fungi and algae. Species of these microorganisms are shown in the paper. Then, mechanisms of MIC are analysed. Although there is no universal mechanism of MIC, MIC is still mainly an electrochemical corrosion in nature. Meanwhile, the mechanisms on SRB and iron bacteria are introduced in details. At last, several methods of microorganisms control are put forward in the paper. 展开更多
关键词 CIRCULATING cooling water System MIC MICROORGANISMS SPECIES MECHANISM Of MIC Control Methods
下载PDF
Effects of Nutrients on Biofouling Formation and Preponderant Bacteria Diversity in Recirculating Cooling Water System 被引量:2
16
作者 Ma Tao Liu Fang +1 位作者 Zhang Guizhi Zhao Chaocheng (College of Chemistry and Chemical Engineering,China University of Petroleum,Qingdao 266555) 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2010年第4期57-62,共6页
A series of orthogonal array experiments were conducted using carbon source, ammonia nitrogen and total phosphorus (TP) as major influencing factors to investigate the effects of nutrients on biofouling formation an... A series of orthogonal array experiments were conducted using carbon source, ammonia nitrogen and total phosphorus (TP) as major influencing factors to investigate the effects of nutrients on biofouling formation and preponderant bacteria diversity in the recirculatiug cooling water system. Carbon source was demonstrated to be the most significant determinant affecting the biofouling formation. A minimum biofouling outcome was obtained when BOD2, NHa+-N and TP were 25, 10, and 1 mg/L, respectively. Then the preponderant bacteria strains in biofouling mass under two typical culture conditions (negative and favorable) were identified applying both traditional biochemical methods and further molecular biology technology with phylogenetic affiliation analysis, which indicated that Enterobacteriaceae Enterobacter, Micrococcaceae Staphylococcus, Bacillaceae Bacillus, Enterobacteriaceae Proteus, Neisseriaceae Neisseria and Pseudomonadaceae Pseudomonas were dominant under negative condition, while Enterobacteriaceae Klebsiella, Enterobacteriaceae Enterobacter and Microbacterium - under favorable one. 展开更多
关键词 recirculating cooling water BIOFOULING numerical analysis polymerase chain reaction
下载PDF
Ion Exchange Softening and Alkalization Treatment for Zerodischarge of Circulating Cooling Water 被引量:1
17
作者 Huiming Zeng Jiuyang Lin +3 位作者 Chunsong Ye Lihui Tong Xiaolan Chen Fei Yu 《Journal of Electromagnetic Analysis and Applications》 2009年第1期6-10,共5页
In order to solve the problems including pipe corrosion, scaling and microbial growth, which severely threat safe op-eration of circulating cooling water system, this paper proposes ion exchange softening and alkaliza... In order to solve the problems including pipe corrosion, scaling and microbial growth, which severely threat safe op-eration of circulating cooling water system, this paper proposes ion exchange softening and alkalization process to solve these problems and carries out a series of studies to study the feasibility of ion exchange softening and alkaliza-tion process in the simulation process of circulating cooling water system. The studies include product water quality of ion exchange softening and alkalization process, effect on the performance of carbon steel and brass, and the inhibition that suppresses microbial growth. The results indicate that ion exchange softening and alkalization process is feasible to prevent the circulating cooling water system from scaling, pipe corrosion, and microbial growth without any other chemicals. Thus circulating cooling water system can achieve zerodischarge of wastewater. 展开更多
关键词 ION EXCHANGE SOFTENING and ALKALIZATION CIRCULATING cooling water Zerodischarge
下载PDF
Dynamic effects of high-pressure pulsed water jet in low-permeability coal seams 被引量:1
18
作者 LI Xiao-hong ZHOU Dong-ping LU Yi-yu KANG Yong ZHAO Yu WANG Xiao-chuan 《Journal of Coal Science & Engineering(China)》 2009年第3期284-288,共5页
Mine gas extraction in China is difficult due to the characteristics such as micro-porosity,low-permeability and high adsorption of coal seams.The pulsed mechanismof a high-pressure pulsed water jet was studied throug... Mine gas extraction in China is difficult due to the characteristics such as micro-porosity,low-permeability and high adsorption of coal seams.The pulsed mechanismof a high-pressure pulsed water jet was studied through theoretical analysis,experimentand field measurement.The results show that high-pressure pulsed water jet has threedynamic properties.What's more,the three dynamic effects can be found in low-permeabilitycoal seams.A new pulsed water jet with 200-1 000 Hz oscillation frequency andpeak pressure 2.5 times than average pressure was introduced.During bubble collapsing,sound vibration and instantaneous high pressures over 100 MPa enhanced the cuttingability of the high-pressure jet.Through high-pressure pulsed water jet drilling and slotting,the exposure area of coal bodies was greatly enlarged and pressure of the coal seamsrapidly decreased.Therefore,the permeability of coal seams was improved and gas absorptionrate also decreased.Application results show that gas adsorption rate decreasedby 30%-40%and the penetrability coefficient increased 100 times.This proves that high-pressurepulsed water is more efficient than other conventional methods. 展开更多
关键词 high-pressure pulsed water jet gas desorption penetrability dynamic effects
下载PDF
CFD Analysis and Optimization of a Diesel Engine Cooling Water Jacket 被引量:1
19
作者 Shunshun Qin Chengfen Xie +3 位作者 Song Li Qi Yang Jianwei Chen Ke Sun 《Fluid Dynamics & Materials Processing》 EI 2022年第3期647-659,共13页
The STAR-CCM+software is used to investigate the flow inside a cooling water jacket of an in-line six-cylinder diesel engine.The results show that the average flow velocity of the cooling water inside the jacket is 1.... The STAR-CCM+software is used to investigate the flow inside a cooling water jacket of an in-line six-cylinder diesel engine.The results show that the average flow velocity of the cooling water inside the jacket is 1.669 m/s while the flow velocity distribution is not uniform for each cylinder.Moreover,the fluid velocity in proximity to the cylinder head is too low,thereby affecting the cooling performances of the water jacket.Two corresponding structural optimization schemes are proposed to mitigate this issue and the post-optimization performances of the water jacket are discussed in detail. 展开更多
关键词 Diesel engine cooling water jacket CFD
下载PDF
Simulation of Gas-Fired Triple-Effect LiBr/Water Absorption Cooling System with Exhaust Heat Recovery Generator 被引量:1
20
作者 汪磊磊 由世俊 +1 位作者 张欢 李宪莉 《Transactions of Tianjin University》 EI CAS 2010年第3期187-193,共7页
An exhaust heat recovery generator is proposed to be integrated with conventional gas-fired triple-effect LiBr/water absorption cooling cycles to improve system energy efficiency. As a case study, simulation of the no... An exhaust heat recovery generator is proposed to be integrated with conventional gas-fired triple-effect LiBr/water absorption cooling cycles to improve system energy efficiency. As a case study, simulation of the novel cycle based on promising parallel flow with cooling capacity of 1 150 kW is carried out under various heat recovery generator vapor production ratios ranging from 0 to 3.5%. The life cycle saving economic analysis, for which the annual gas conservation is estimated with Bin method, is employed to prove the worthiness of extra expenditure. Results show that the optimum gas saving revenue is obtained at 2.8% heat recovery generator vapor production ratio with 42 kW exhaust heat recovered, and the system energy efficiency is improved from 1.78 to 1.83. The initial investment of exchanger can be paid back within 7 years and 9 000 CNY of gas saving revenue will be achieved over the 15-year life cycle of the machine. This technology can be easily implemented and present desirable economic effects, which is feasible to the development of triple-effect absorption cycles. 展开更多
关键词 LiBr/water triple-effect absorption cooling cycle exhaust heat recovery
下载PDF