期刊文献+
共找到1,792篇文章
< 1 2 90 >
每页显示 20 50 100
Development of a high-repetition-rate lumped-inductance kicker magnet prototype for the beam switchyard of SHINE
1
作者 Yong-Fang Liu Rui-Ping Wang +6 位作者 Jin Tong Bo Zhang Si Chen Qi-Bing Yuan Hai-Xiao Deng Ming Gu Bo Liu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第2期20-31,共12页
The Shanghai high-repetition-rate X-ray free-electron laser and extreme light facility(SHINE)operates at a maximum repetition rate of 1 MHz.Kicker magnets are key components that distribute electron bunches into three... The Shanghai high-repetition-rate X-ray free-electron laser and extreme light facility(SHINE)operates at a maximum repetition rate of 1 MHz.Kicker magnets are key components that distribute electron bunches into three different undulator lines in a bunch-by-bunch mode.The kicker field width must be less than the time interval between bunches.A lumpedinductance kicker prototype was developed using a vacuum chamber with a single-turn coil.The full magnetic field strength was 0.005 T.This paper presents the requirements,design considerations,design parameters,magnetic field calculations,and measurements of the kicker magnets.The relevant experimental results are also presented.The pulse width of the magnetic field was approximately 600 ns,and the maximum operation repetition rate was 1 MHz.The developed kicker satisfies the requirements for the SHINE project.Finally,numerous recommendations for the future optimization of kicker magnets are provided. 展开更多
关键词 X-ray free-electron laser Kicker magnet Beam switchyard High repetition rate Ni-Zn ferrites
下载PDF
High-rate metal-free MXene microsupercapacitors on paper substrates
2
作者 Han Xue Po‐Han Huang +11 位作者 Lee‐Lun Lai Yingchun Su Axel Strömberg Gaolong Cao Yuzhu Fan Sergiy Khartsev Mats Göthelid Yan‐Ting Sun Jonas Weissenrieder Kristinn BGylfason Frank Niklaus Jiantong Li 《Carbon Energy》 SCIE EI CAS CSCD 2024年第5期94-104,共11页
MXene is a promising energy storage material for miniaturized microbatteries and microsupercapacitors(MSCs).Despite its superior electrochemical performance,only a few studies have reported MXene-based ultrahigh-rate(... MXene is a promising energy storage material for miniaturized microbatteries and microsupercapacitors(MSCs).Despite its superior electrochemical performance,only a few studies have reported MXene-based ultrahigh-rate(>1000 mV s^(−1))on-paper MSCs,mainly due to the reduced electrical conductance of MXene films deposited on paper.Herein,ultrahigh-rate metal-free on-paper MSCs based on heterogeneous MXene/poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate)(PEDOT:PSS)-stack electrodes are fabricated through the combination of direct ink writing and femtosecond laser scribing.With a footprint area of only 20 mm^(2),the on-paper MSCs exhibit excellent high-rate capacitive behavior with an areal capacitance of 5.7 mF cm^(−2)and long cycle life(>95%capacitance retention after 10,000 cycles)at a high scan rate of 1000 mV s^(−1),outperforming most of the present on-paper MSCs.Furthermore,the heterogeneous MXene/PEDOT:PSS electrodes can interconnect individual MSCs into metal-free on-paper MSC arrays,which can also be simultaneously charged/discharged at 1000 mV s^(−1),showing scalable capacitive performance.The heterogeneous MXene/PEDOT:PSS stacks are a promising electrode structure for on-paper MSCs to serve as ultrafast miniaturized energy storage components for emerging paper electronics. 展开更多
关键词 direct ink writing femtosecond laser scribing MXene on-paper microsupercapacitors PEDOT:PSS ultrahigh rate capability
下载PDF
High power diode-pumped passively mode-locked Nd:YVO_4 laser at repetition rate of 3.2 GHz 被引量:2
3
作者 程梦尧 王兆华 +4 位作者 曹艳芳 孟祥昊 朱江峰 王军利 魏志义 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第5期122-125,共4页
A compact high power diode-pumped passively mode-locked Nd:YVO_4 laser with high repetition rate is realized.Using an Nd:YVO_4 crystal and a semiconductor saturable absorber mirror(SESAM) in the oscillator, the picose... A compact high power diode-pumped passively mode-locked Nd:YVO_4 laser with high repetition rate is realized.Using an Nd:YVO_4 crystal and a semiconductor saturable absorber mirror(SESAM) in the oscillator, the picosecond pulse output with an average power of 1.38 W, a repetition rate of 3.24 GHz, and a pulse duration of 11.4 ps is achieved. After one stage of amplification, the final output power reaches 11.34 W, corresponding to a total optical-to-optical efficiency of about 32%. The root mean square(RMS) value of power fluctuation is demonstrated to be less than 0.6% in 24 hours,showing a superior stability with the compact configuration. 展开更多
关键词 ALL-SOLID-STATE laser high REPETITION rate ND:YVO4 laser MODE-LOCKED laser
下载PDF
Effects of high temperature annealing and laser irradiation on activation rate of phosphorus 被引量:1
4
作者 Shaojie Li Peide Han 《Journal of Semiconductors》 EI CAS CSCD 2020年第12期84-89,共6页
Thermal annealing and laser irradiation were used to study the activation rate of phosphorus in silicon after ion implantation.The activation rate refers to the ratio of activated impurity number to the total impurity... Thermal annealing and laser irradiation were used to study the activation rate of phosphorus in silicon after ion implantation.The activation rate refers to the ratio of activated impurity number to the total impurity number in the sample.After injecting phosphorus with the dose and energy(energy=55 keV,dose=3×10^(15) cm^(-2)),the samples were annealed at different temperatures,and laser irradiation experiments were performed after annealing.The experimental results showed that the activation rate of phosphorus was the highest at 850℃,and the highest activation rate was 67%.Upon femtosecond laser irradiation samples after thermal annealing,while keeping the crystalline silicon surface without damage,the activation rate was improved.When the energy-flux density of the femtosecond laser was 0.65 kJ/cm2,the activation rate was the highest,increasing from 67%to 74.81%. 展开更多
关键词 thermal annealing ion implantation femtosecond laser activation rate
下载PDF
Passive Q-Switching of a Yb:LuVO_4 Laser with Cr^(4+):YAG:Approaching the Intrinsic Upper Limit of Repetition Rate 被引量:3
5
作者 窦晓丹 杨婧男 +3 位作者 马衍骏 韩文娟 徐洪浩 刘均海 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第6期28-32,共5页
We demonstrate a diode pumped Yb:LuVO4 laser that can be passively Q-switched by a Cr^(4+):YAG saturable absorber having an initial transmission as high as 99.3%.A maximum pulsed output power of 2.35 W is generat... We demonstrate a diode pumped Yb:LuVO4 laser that can be passively Q-switched by a Cr^(4+):YAG saturable absorber having an initial transmission as high as 99.3%.A maximum pulsed output power of 2.35 W is generated at a repetition rate of 285.7 kHz,approaching or very near the intrinsic upper limit imposed by the recovery time of the Cr^(4+):YAG saturable absorber,and the resulting pulse energy,duration and peak power are,respectively,8.2μJ,39.2ns and 0.209kW. 展开更多
关键词 YAG:Approaching the Intrinsic Upper Limit of Repetition rate YB Passive Q-Switching of a Yb:LuVO4 laser with Cr
下载PDF
Erbium-Doped Zirconia-Alumina Silica Glass-Based Fiber as a Saturable Absorber for High Repetition Rate Q-Switched All-Fiber Laser Generation 被引量:1
6
作者 P. Harshavardhan Reddy N. A. A. Kadir +5 位作者 M. C. Paul S, Das A. Dhar E. I. Ismail A. A. Latiff S. W. Harun 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第8期63-66,共4页
We propose and demonstrate a Q-switched erbium-doped fiber laser (EDFL) using an erbium-doped zirconia-alumina silica glass-based fiber (Zr-EDF) as a saturable absorber. As a 16-cm-long Zr-EDF is incorporated into... We propose and demonstrate a Q-switched erbium-doped fiber laser (EDFL) using an erbium-doped zirconia-alumina silica glass-based fiber (Zr-EDF) as a saturable absorber. As a 16-cm-long Zr-EDF is incorporated into a ring EDFL cavity, a stable Q-switching pulse train operating at 1565?nm wavelength is successfully obtained. The repetition rate is tunable from 33.97?kHz to 71.23?kHz by increasing the pump power from the threshold of 26?mW to the maximum of 74?mW. The highest pulse energy of 26.67?nJ is obtained at the maximum pump power. 展开更多
关键词 EDF Zr Erbium-Doped Zirconia-Alumina Silica Glass-Based Fiber as a Saturable Absorber for High Repetition rate Q-Switched All-Fiber laser Generation kHz AS
下载PDF
Generation of high-energy dual-wavelength domain wall pulse with low repetition rate in an HNLF-based fiber ring laser
7
作者 罗智超 林振彬 +5 位作者 李金玉 朱鹏飞 宁秋奕 邢晓波 罗爱平 徐文成 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第6期217-220,共4页
The generation of high-energy dual-wavelength domain wall pulse with a low repetition rate is demonstrated in a highly nonlinear fiber (HNLF)-based fiber ring laser. By introducing the intracavity birefringence-indu... The generation of high-energy dual-wavelength domain wall pulse with a low repetition rate is demonstrated in a highly nonlinear fiber (HNLF)-based fiber ring laser. By introducing the intracavity birefringence-induced spectral filtering effect, the dual-wavelength lasing operation can be achieved. In order to enhance the cross coupling effect between the two lasing beams for domain wall pulse formation, a 215-m HNLF is incorporated into the laser cavity. Experimentally, it is found that the dual-wavelength domain wall pulse with a repetition rate of 77.67 kHz could be efficiently obtained through simply rotating the polarization controller (PC). At a maximum pump power of 322 mW, the 655-nJ single pulse energy in cavity is obtained. The proposed configuration provides a simpler and more efficient way to generate high energy pulse with a low repetition rate. 展开更多
关键词 fiber lasers high-energy pulse domain wall low repetition rate
下载PDF
Dispersion relation and growth rate for a corrugated channel free-electron laser with a helical wiggler pump
8
作者 A.Hasanbeigi H. Mehdian 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第7期364-368,共5页
The effects of corrugated ion channels on electron trajectories and spatial growth rate for a free-electron laser with a one-dimensional helical wiggler have been investigated. Analysis of the steady-state electron tr... The effects of corrugated ion channels on electron trajectories and spatial growth rate for a free-electron laser with a one-dimensional helical wiggler have been investigated. Analysis of the steady-state electron trajectories is performed by solving the equations of motion. Our results show that the presence of a corrugated channel shifts the resonance frequency to smaller values of ion channel frequency. The sixth-order dispersion equation describing the coupling between the electrostatic beam mode and the electromagnetic mode has also been derived. The dispersion relation characteristic is analyzed in detail by numerical solution. Results show that the growth rate of instability in the presence of corrugated ion channels can be greatly enhanced relative to the case of an uniform ion channel. 展开更多
关键词 corrugated ion-channel free-electron laser growth rate helical wiggler
下载PDF
Laser back scatter: Limitation to higher repetition rate [kHz] Satellite Laser Ranging system
9
作者 Farhat Iqbal G.Kirchner +1 位作者 F.Koidl Erich Leitgeb 《Geodesy and Geodynamics》 CSCD 2021年第1期48-53,共6页
Satellite laser ranging(SLR)with higher repetition rate is the recent trend for its various advantages.Laser backscatter(coincidence between recently transmitted pulses and received pulses near the detector)is found t... Satellite laser ranging(SLR)with higher repetition rate is the recent trend for its various advantages.Laser backscatter(coincidence between recently transmitted pulses and received pulses near the detector)is found to be a constraint for the repetition rates higher than 20 kHz,due to,overlapping with photons returning from a satellite with the present constellation of most of the SLR systems.Such an overlap occurs at every 75 km satellite distance change at 2 kHz repetition rate,and remains for about 7.5 km;for a 20 kHz system however,it will occur after every 7.5 km and remains for 7.5 km,resulting in constant backscatter overlap e leaving no chance to avoid it.The resulting noise is 5 times more than before causing a serious problem in detection and lowers the signal to noise ratio of the overall SLR system.However,decreasing energy per shot at higher repetition rates e assuming a constant power laser e the resulting backscatter may decrease fractionally. 展开更多
关键词 Satellite laser ranging Higher repetition rate Noise Retro reflectors
下载PDF
Fast repetition rate fs pulsed lasers for advanced PLIM microscopy
10
作者 Sviatlana Kalinina Alexander Jelzow +1 位作者 Tobias Plotzing Angelika Rück 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2019年第5期86-94,共9页
Simultaneous metabolic and oxygen imaging is promising to follow up therapy response,dis-ease development and to determine prognostic factors.FLIM of metabolic coenzymes is now widely accepted to be the most reliable ... Simultaneous metabolic and oxygen imaging is promising to follow up therapy response,dis-ease development and to determine prognostic factors.FLIM of metabolic coenzymes is now widely accepted to be the most reliable method to determine cellular bioenergetics.Also,oxygen consumption has to be taken into account to understand treatment responses.The phosphorescence lifetimne of oxygen sensors is able to indicate local oxygen changes.For phosphorescence lifetime imaging(PLIM)dyes based on ruthenium(I)coordination com-plexes are useful,in detaill TLD1433 which possesses a variety of different triplet states,enables complex photochemistry and redox reactions.PLIM is usally reached by two photon exci-tation of the drug with a femtosecond(fs)pulsed Ti:Sapphire laser working at 80 MHz repe-tition rate and(time-correlated single photon counting)(TCSPC)detection electronics.The interesting question was whether it is possible to follow up PLIM 1using faster repetition rates.Faster repetition rates could be advantageous for the induction of specific photochemical reactions because of similar light doses used normally in standard CW light treatments.For this,a default 2p-FLIM-PLIM system was expanded by adding a second fs pulsed laser("helixx")which provides 50 fs pulses at a repetition rate of 250 MHz,more than 2.3 w average power and tunable from 720 nm to 920 nm.The laser beam was coupled into the AOM instead of the default 80 MHz laser.We demonstrated siuccessful applications of the 250 MHz laser for PLIM which correlates well with measurements done by excitation with the conventional 80MHx laser source. 展开更多
关键词 Multiphoton microscopy axygen consumption phosphorescence lifetime microscopy fast repetition rate excitation short laser pulses Ru(I)complexes
下载PDF
Cooling rate calibration and mapping of ultra-short pulsed laser modifications in fused silica by Raman and Brillouin spectroscopy
11
作者 Michael Bergler Kristian Cvecek +3 位作者 Ferdinand Werr Martin Brehl Dominique De Ligny Michael Schmidt 《International Journal of Extreme Manufacturing》 2020年第3期161-172,共12页
This paper focuses on the preparation of a new extended set of calibrations of cooling rate(fictive temperature)in fused silica determined by inelastic light scattering and its subsequent use to characterize the local... This paper focuses on the preparation of a new extended set of calibrations of cooling rate(fictive temperature)in fused silica determined by inelastic light scattering and its subsequent use to characterize the local cooling rate distribution in ultra-short pulsed(USP)laser modification.In order to determine the thermal history(e.g.cooling rate and fictive temperature)of fused silica,high-resolution inelastic light-scattering experiments(Raman and Brillouin spectroscopy)were investigated.Calibrations were performed and compared to the existing literature to quantify structural changes due to a change of fictive temperature.Compared to existing calibrations,this paper provides an extension to lower and higher cooling rates.Using this new set of calibrations,we characterized a USP laser modification in fused silica and calculated the local fictive temperature distribution.An equation relating the fictive temperature(Tf)to cooling rates is given.A maximum cooling rate of 3000 K min-1 in the glass transition region around 1200℃ was deduced from the Raman analysis.The Brillouin observations are sensitive to both the thermal history and the residual stress.By comparing the Raman and Brillouin observations,we extracted the local residual stress distribution with high spatial resolution.For the first time,combined Raman and Brillouin inelastic light scattering experiments show the local distribution of cooling rates and residual stresses(detailed behavior of the glass structure)in the interior and the surrounding of an USP laser modified zone. 展开更多
关键词 glass structure ultra-short pulsed laser fused silica cooling rate fictive temperature Raman spectroscopy Brillouin spectroscopy
下载PDF
Science Letters:Controllable high repetition rate gain-switchedNd:YVO_4 microchip laser
12
作者 盛芳 陈军 葛剑虹 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第2期79-82,共4页
We demonstrated a monolithic, compact, diode-pumped gain-switched Nd:YVO4 laser at 1.064 μm wavelength with controllable repetition rate of 1 Hz to 25 kHz. Stable gain-switched pulse train with maximum repetition rat... We demonstrated a monolithic, compact, diode-pumped gain-switched Nd:YVO4 laser at 1.064 μm wavelength with controllable repetition rate of 1 Hz to 25 kHz. Stable gain-switched pulse train with maximum repetition rate of 25 kHz and pulse width of 16 ns was obtained. 展开更多
关键词 激光技术 微芯片 循环速度 脉冲
下载PDF
Experimental Study of Buffer Gas Flow Rate Effect on Output Power of a Copper Vapor Laser
13
作者 Saeid Behrouzinia Kamran Khorasani +3 位作者 Saeid Marjani Masoud Sabaghi Mohammad Ebrahim Aeinehvand Sadegh Mohammadpour 《Optics and Photonics Journal》 2016年第2期24-28,共5页
A copper vapor laser with active medium length of 60 cm and bore of 16 mm has been operated and optimized using different buffer gases to investigate the effect of the gas flow rates on the output power. It is found t... A copper vapor laser with active medium length of 60 cm and bore of 16 mm has been operated and optimized using different buffer gases to investigate the effect of the gas flow rates on the output power. It is found that there is a special optimum gas flow rate associated with the type of buffer gas. 展开更多
关键词 Copper Vapor laser Gas Flow rate Output Power
下载PDF
Development of miniaturized SAF-LIBS with high repetition rate acousto-optic gating for quantitative analysis
14
作者 陈斐 侯佳佳 +10 位作者 王刚 赵洋 李佳轩 王树青 张雷 张婉飞 马晓飞 刘珍荣 罗学彬 尹王保 贾锁堂 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第1期157-164,共8页
The self-absorption effect in laser-induced breakdown spectroscopy(LIBS)reduces the accuracy of quantitative measurement results.The self-absorption-free LIBS(SAF-LIBS)has been proved to directly capture the optically... The self-absorption effect in laser-induced breakdown spectroscopy(LIBS)reduces the accuracy of quantitative measurement results.The self-absorption-free LIBS(SAF-LIBS)has been proved to directly capture the optically thin plasma spectra by setting an appropriate exposure time.In this work,a novel SAF-LIBS technique with high repetition rate acousto-optic gating is developed,in which an acousto-optic modulator is used as the shutter to diffract the optically thin fluorescence,and a high repetition rate laser is used to produce quasi-continuous plasmas to enhance the integral spectral intensity,so that the CCD spectrometer can replace an intensified CCD(ICCD)and echelle spectrometer in SAF-LIBS.Experimental results show that the average absolute prediction error of aluminum is reduced to 0.18%,which is equivalent to that of traditional SAF-LIBS.This technique not only effectively shields continuous background radiation and broadened spectral lines in optically thick plasma,but also has advantages of miniaturization,low cost,convenience and reliability. 展开更多
关键词 self-absorption-free LIBS(SAF-LIBS) self-absorption effect optically thin plasma high repetition rate laser acousto-optic gating
下载PDF
塞斯纳172飞机发动机机匣脉冲激光清洗工艺研究
15
作者 杨文锋 杨帆 +3 位作者 朱小伟 李绍龙 樊占鹏 李天权 《航空制造技术》 CSCD 北大核心 2024年第5期82-88,共7页
针对航空发动机机匣表面除漆需求,采用纳秒脉冲激光开展了塞斯纳172飞机发动机机匣表面漆层的激光清洗研究。通过对机匣除漆区域的表面形貌及粗糙度进行分析,探究了激光能量密度与扫描速度对机匣表面漆层清洗效果的影响规律,确定了机匣... 针对航空发动机机匣表面除漆需求,采用纳秒脉冲激光开展了塞斯纳172飞机发动机机匣表面漆层的激光清洗研究。通过对机匣除漆区域的表面形貌及粗糙度进行分析,探究了激光能量密度与扫描速度对机匣表面漆层清洗效果的影响规律,确定了机匣激光除漆最佳工艺参数,并对机匣除漆后的表面质量、显微硬度及粗糙度进行综合评估。结果表明,能量密度和扫描速度均显著影响机匣除漆质量,能量密度18.33 J/cm^(2)、扫描速度1600 mm/s时,可实现除漆率98.7%,表面粗糙度S_(a)为2.48μm,机匣本身未损伤,表面显微硬度提升1.9%,满足机匣表面除漆质量要求。研究结果为发动机机匣激光除漆提供了理论与技术支持。 展开更多
关键词 航空发动机 激光除漆 表面形貌 显微硬度 除漆率
下载PDF
改进型超声引导下针状可视肾镜(Needle perc)钬激光碎石术治疗肾下盏结石的临床评价:与输尿管软镜对比
16
作者 吴辉 孔莹莹 +3 位作者 高江涛 陈松林 杨银毫 李纪华 《现代泌尿外科杂志》 CAS 2024年第4期302-305,共4页
目的比较改进型超声引导下针状可视肾镜(Needle perc)钬激光碎石术和输尿管软镜下钬激光碎石术治疗1~2 cm肾下盏结石的效果,为临床治疗方式的选择提供参考。方法回顾性分析2022年1月—2023年5月郑州市第一人民医院收治的60例肾内单发下... 目的比较改进型超声引导下针状可视肾镜(Needle perc)钬激光碎石术和输尿管软镜下钬激光碎石术治疗1~2 cm肾下盏结石的效果,为临床治疗方式的选择提供参考。方法回顾性分析2022年1月—2023年5月郑州市第一人民医院收治的60例肾内单发下盏结石(最大径1~2 cm)患者的临床资料,比较行输尿管软镜钬激光碎石术的30例患者(软镜组)和改进型超声引导下Needle perc钬激光碎石术的30例患者(Needle perc组)的临床资料。结果Needle perc组较软镜组的整体住院时间[(3.00±1.25)d vs.(4.00±1.25)d]、手术时间[(44.63±5.42)min vs.(48.50±7.24)min]和住院花费[(15518±441)元vs.(16872±903)元]均较少(P<0.05)。Needle perc组术后清石率高于软镜组[93.3%(28/30)vs.50.7%(15/30),P<0.001]。术后降钙素原(PCT)上升幅度低于软镜组[(0.02±0.01)vs.(0.12±0.18),P=0.007],而并发症发生率低于软镜组[3.3%(1/30)vs.26.7%(8/30),P=0.030]。结论对于1~2 cm的肾下盏单发结石,改进型超声引导下Needle perc钬激光碎石术清石率较高、并发症发生率低,安全且有效。 展开更多
关键词 肾结石 针状可视肾镜 钬激光碎石术 输尿管软镜 结石清除率
下载PDF
非肌层浸润性膀胱癌患者二次经尿道膀胱肿瘤钬激光切除术的临床意义
17
作者 王阳 李新悟 +4 位作者 段启新 李征 胡跃世 谷傲峥 朱清 《实用癌症杂志》 2024年第4期659-662,共4页
目的探讨非肌层浸润性膀胱癌(NMIBC)患者二次经尿道膀胱肿瘤钬激光切除术治疗的临床效果。方法选取82例NMIBC患者,按随机数字表法分为2组,各41例。对照组予以经尿道膀胱肿瘤电切术(TURBT)治疗,观察组予以经尿道膀胱肿瘤钬激光切除术治... 目的探讨非肌层浸润性膀胱癌(NMIBC)患者二次经尿道膀胱肿瘤钬激光切除术治疗的临床效果。方法选取82例NMIBC患者,按随机数字表法分为2组,各41例。对照组予以经尿道膀胱肿瘤电切术(TURBT)治疗,观察组予以经尿道膀胱肿瘤钬激光切除术治疗。比较2组手术情况、炎症因子水平、氧化应激因子、病理诊断准确率及并发症。结果观察组肉眼血尿时间[(1.29±0.23)d]、尿管留置时间[(2.35±0.27)d]、术后膀胱冲洗时间[(1.42±0.25)d]较对照组短,有统计学差异(P<0.05)。观察组治疗后白介素-6(IL-6)[(67.25±6.19)pg/mL]、C反应蛋白(CRP)[(17.25±2.19)mg/L]及肿瘤坏死因子-α(TNF-α)[(40.39±4.28)pg/mL]水平较对照组低,有统计学差异(P<0.05)。观察组治疗后丙二醛(MDA)[(5.74±1.05)mmol/L]水平低于对照组,超氧化物岐化酶(SOD)[(105.96±9.58)μmol/L]及谷胱甘肽过氧化物酶(GSH-Px)[(70.14±6.23)pg/mL]水平较对照组高,有统计学差异(P<0.05)。观察组病理诊断准确率[90.24%(37/41)]高于对照组,并发症发生率[4.88%(2/41)]低于对照组,有统计学差异(P<0.05)。结论二次经尿道膀胱肿瘤钬激光切除术治疗NMIBC较TURBT效果更佳,能够减轻手术创伤,缩短肉眼血尿、尿管留置时间,减轻炎症反应及氧化应激反应,且切除标本更符合病理分期要求,安全可靠。 展开更多
关键词 膀胱癌 二次经尿道膀胱肿瘤切除术 钬激光 复发率 并发症
下载PDF
可控负压吸引下输尿管软镜钬激光碎石术治疗肾结石合并尿路感染的疗效分析
18
作者 梁浩 冯振华 +1 位作者 彭业平 黄强 《中国实用医药》 2024年第2期46-49,共4页
目的 分析肾结石且伴有尿路感染患者应用可控负压吸引下输尿管软镜钬激光碎石术治疗的临床效果。方法 80例肾结石合并尿路感染患者,将样本经随机法分为实验组和对照组,每组40例。对照组患者接受常压输尿管软镜钬激光碎石术治疗,实验组... 目的 分析肾结石且伴有尿路感染患者应用可控负压吸引下输尿管软镜钬激光碎石术治疗的临床效果。方法 80例肾结石合并尿路感染患者,将样本经随机法分为实验组和对照组,每组40例。对照组患者接受常压输尿管软镜钬激光碎石术治疗,实验组患者接受可控负压吸引下输尿管软镜钬激光碎石术治疗。比较两组患者术后住院时间、术后血尿时间、手术时间、术后结石清除率及术后感染发生情况。结果 实验组患者的术后住院时间(2.55±1.45)d、术后血尿时间(1.13±0.56)d、手术时间(42.30±4.24)min明显短于对照组的(4.00±2.35)d、(2.20±0.65)d、(63.03±6.33)min(P<0.05)。实验组患者的术后感染发生率为12.5%(5/40),相比于对照组的40.0%(16/40)低(P<0.05),手术更安全、可靠。实验组患者的术后结石清除率97.5%(39/40)显著高于对照组的82.5%(33/40)(P<0.05),术后残石率更低。结论 可控负压吸引下输尿管软镜钬激光碎石术应用于肾结石合并尿路感染治疗中,能够有效缩短住院时间及手术时间,提高术后结石清除率,降低患者术后发热发生率,安全有效。 展开更多
关键词 肾结石 可控负压吸引 输尿管软镜钬激光碎石术 尿路感染 结石清除率
下载PDF
高重频激光对测距机干扰试验研究
19
作者 张澜 万勇 +6 位作者 刘全喜 龙幸 张小川 邬焕欣 衣学斌 卢德林 杲静 《红外与激光工程》 EI CSCD 北大核心 2024年第4期110-119,共10页
高重频激光干扰是对脉冲式激光测距机的一种有效干扰手段,为探究高重频激光对测距机干扰效能的影响因素及规律,开展相关的理论分析与试验研究。试验研究了干扰激光的功率、重复频率及干扰距离对测距机干扰效能的影响。结果表明:存在一... 高重频激光干扰是对脉冲式激光测距机的一种有效干扰手段,为探究高重频激光对测距机干扰效能的影响因素及规律,开展相关的理论分析与试验研究。试验研究了干扰激光的功率、重复频率及干扰距离对测距机干扰效能的影响。结果表明:存在一个与干扰激光频率相关的最小干扰距离,干扰激光的重复频率越高,最小干扰距离越小,有效干扰距离范围越大。当实际干扰距离大于最小干扰距离时,若干扰激光的功率不足,则无干扰效果;干扰成功后继续增大干扰激光功率,则被干扰后测距结果会趋于正态分布,且干扰激光功率越高,测距结果正态分布中心越趋近于最小干扰距离,但受干扰的测距结果最小值会始终分布于测距机盲区附近。 展开更多
关键词 高重频激光 脉冲式激光测距 激光干扰 最小干扰距离 干扰效能
下载PDF
高重频声光门控自吸收免疫激光诱导击穿光谱技术分析研究
20
作者 陈斐 王树青 +13 位作者 程年恺 张婉飞 张岩 梁佳慧 张雷 王钢 马晓飞 刘珍荣 罗学彬 叶泽甫 朱竹军 尹王保 肖连团 贾锁堂 《中国光学(中英文)》 EI CAS CSCD 北大核心 2024年第2期253-262,共10页
为了消除激光诱导击穿光谱技术(laser-induced breakdown spectroscopy,LIBS)中的自吸收效应,提高元素定量分析的精确度,同时满足工业中便捷分析元素的要求,需将自吸收免疫激光诱导击穿光谱技术(self-absorption free laser-induced bre... 为了消除激光诱导击穿光谱技术(laser-induced breakdown spectroscopy,LIBS)中的自吸收效应,提高元素定量分析的精确度,同时满足工业中便捷分析元素的要求,需将自吸收免疫激光诱导击穿光谱技术(self-absorption free laser-induced breakdown spectroscopy,SAF-LIBS)的装置小型化。本文提出了一项新型的高重频声光门控SAF-LIBS定量分析技术,使用高重频激光器产生准连续的等离子体以增强光谱强度,并将声光调制器(acousto-optic modulator,AOM)作为门控开关,从而使微型CCD光谱仪和AOM能够代替传统大型SAF-LIBS装置中的像增强探测器(intensified charge coupled device,ICCD)和中阶梯型光栅光谱仪,实现自吸收免疫的同时缩小了装置的体积,降低了装置的成本。将该系统参数进行优化选择后,对样品中的Al元素进行了定量分析和预测。实验结果表明,等离子体的特性受激光重复频率的影响进而会影响光谱信号的强度。在1~50 kHz激光重复频率范围内,Al I 394.4 nm和Al I 396.15 nm的双线强度先增强后减弱,确定最佳的激光重复频率为10 kHz。在不同的光纤采集角度下,Al的双线强度比随延迟时间的增加而减小,在45°处信噪比最高,且在一定的积分时间下,最佳光学薄时间t_(ot)为426 ns。在激光重复频率为10 kHz、光纤采集角为45°、延迟时间为400 ns的条件下,对Al元素进行定量分析和预测结果表明,Al元素定标曲线的线性度R2为0.982,平均绝对测量误差相对于单一LIBS的0.8%可以降低至0.18%。定量分析结果与传统大型SAF-LIBS装置的测量精度相持平。因此本高重频声光门控SAF-LIBS装置不仅有效地屏蔽了光学厚等离子体中的连续背景辐射和谱线加宽,同时具备小型化、低成本、高可靠性的优点,有助于推动SAF-LIBS技术由实验室走向工业应用。 展开更多
关键词 激光诱导击穿光谱 自吸收免疫 光学薄 高重频激光器 声光门控
下载PDF
上一页 1 2 90 下一页 到第
使用帮助 返回顶部