Four kinds of high-resistivity carbon brushes with MoS2 contents of 0%,2%,4%and 6%(mass fraction)were prepared, respectively.Wear tests of brushes were conducted on an alternate current(AC)motor.Scanning electron micr...Four kinds of high-resistivity carbon brushes with MoS2 contents of 0%,2%,4%and 6%(mass fraction)were prepared, respectively.Wear tests of brushes were conducted on an alternate current(AC)motor.Scanning electron microscopy(SEM)and energy dispersive X-ray analysis(EDS)were used to analyze the worn surface of brushes,and a thermocouple was used to measure the bulk temperature of the brush.The results show that wear rate of brush made without MoS2 in 10%relative humidity(RH)is two times larger than that in 50%RH,whereas the wear rates change little for the brushes made with MoS2.The wear of brushes has much to do with the surface film.In low humidity,the surface film can not be formed for the former brush while a sulfur layer can be formed for the latter brushes,which can reduce sparks,frictional heat and wear rate,and play a role like the water film in high humidity.展开更多
In order to avoid the deep-well oil shale roadway being deformed, damaged, or difficult to maintain after excavating and supporting in Haishiwan coal mine, this paper has analyzed the characteristics of the deformed r...In order to avoid the deep-well oil shale roadway being deformed, damaged, or difficult to maintain after excavating and supporting in Haishiwan coal mine, this paper has analyzed the characteristics of the deformed roadway and revealed its failure mechanism by taking comprehensively the methods of field geological investigation, displacement monitoring of surrounding rock, rock properties and hydration properties experiments and field application tests. Based on this work, the high-resistance controlled yielding supporting principle is proposed, which is: to "resist" by high pre-tightening force and high stiff- ness in the early stage, to "yield" by making use of the controlled deformation of a yielding tube in the middle stage, and to "fix" by applying total-section Gunite in the later stage. A high-resistance controlled yielding supporting technique of "high pre-tightening force yielding anchor bolt + small-bore pre-tight- ening force anchor cable + rebar ladder beam + rhombic metal mesh + lagging gunite" has been estab- lished, and industrial on site testing implemented. The practical results show that the high-resistance controlled yielding supporting technique can effectively control the large deformation and long-time rheology of deep-well oil shale roadways and can provide beneficial references for the maintenance of other con-generic roadways.Deep-well Oil shale展开更多
In recent years, microstrip antennas have been more widely applied in satellite communications, mobile phones, unmanned aerial vehicle (UAV), and weapons. A micro-electro-mechanical systems-based (MEMS-based) high...In recent years, microstrip antennas have been more widely applied in satellite communications, mobile phones, unmanned aerial vehicle (UAV), and weapons. A micro-electro-mechanical systems-based (MEMS-based) high-resistance silicon C-band microstrip antenna array has been designed for the intelligent ammunition. The center frequency is 4.5 GHz. A cavity has been designed in substrate to reduce the dielectric constant of silicon and high-resistance silicon has been used as the material of substrate to improve the gain of antenna. It is very easy to be manufactured by using MEMS technology because of the improved structure of the antenna. The results show that the gain of the antenna is 8 dB and voltage standing wave ratio (VSWR) is less than 2 by the analysis and simulation in high freauencv structure simulator (HFSS).展开更多
For large generators, the problem of high-resistance grounding method and the advantages of resonance, grounding method are discussed in detail, and an overall comparison is given in this paper. It is recommended that...For large generators, the problem of high-resistance grounding method and the advantages of resonance, grounding method are discussed in detail, and an overall comparison is given in this paper. It is recommended that the latter should be adopted so as to increase the operation reliability of large generators and power systems.展开更多
Confronting the severe health threats and environmental impacts of Cr(Ⅵ) in aquatic environments demands innovative and effective remediation approaches. In this study, Graphene oxide(GO)-decorated poly(dimethyl amin...Confronting the severe health threats and environmental impacts of Cr(Ⅵ) in aquatic environments demands innovative and effective remediation approaches. In this study, Graphene oxide(GO)-decorated poly(dimethyl amino ethyl methacrylate)(PDMAEMA) brush nanocomposites(GOP1, GOP2, GOP3, and GOP4) were fabricated using atom transfer radical polymerization(ATRP) by the “graft from” method.The resulting nanocomposites were utilized for removing Cr(Ⅵ) with good adsorption performance due to the electrostatic interaction of protonated nitrogen groups in the brush chains with negatively charged particles in the solution. The kinetic model of pseudo-second-order best represented the contaminants' adsorption characteristics. The Weber-Morris model further indicated that surface adsorption and intraparticle diffusion mechanisms primarily controlled the adsorption procedure. Additionally, the Langmuir and Temkin isotherm models were found to most accurately represent the adsorption characteristics of the pollutants on the nanocomposites, and GOP4 can achieve the maximum adsorption capacity of 164.4 mg·g^(-1). The adsorbents' capacity maintains above 85% after five cycles of adsorption-desorption. The nanocomposites in this study demonstrate promising potential for eliminating Cr(Ⅵ) from aqueous solutions.展开更多
Herein,binary mixed brushes consisting of poly(2-methyl-2-oxazoline)(PMOXA)and poly(2-(dimethylamine)ethyl methacrylate)(PDMAEMA)with different chain lengths were fabricated by successive grafting of NH_(2)-terminated...Herein,binary mixed brushes consisting of poly(2-methyl-2-oxazoline)(PMOXA)and poly(2-(dimethylamine)ethyl methacrylate)(PDMAEMA)with different chain lengths were fabricated by successive grafting of NH_(2)-terminated PMOXA and SH-terminated PDMAEMA onto polydopamine-anchored substrates.The mixed-brush coating was characterized by variable-angle spectroscopic ellipsometry,X-ray photoelectron spectroscopy,Fourier transform infrared spectroscopy,zeta potential measurements,water contact angle,and atomic force microscopy.The mixed brushes showed tunable surface charge,wettability,and surface roughness,depending on the degree of PDMAEMA swelling under varying pH and ionic strength(Ⅰ).Then the adsorption behaviors of pepsin,bovine serum albumin(BSA),γ-globulin,and lysozyme,four very different proteins with regard to isoelectric point,on the mixed brushes coating were studied by using fluorescence microscopy and surface plasmon resonance.When the chain length of PDMAEMA was about twice as long as PMOXA,the mixed brushes not only had high adsorption capacity for pepsin,BSA,and y-globulin but also had a desorption efficiency of 86.9%,87.1%,and 93.5%,respectively.It is explained that electrostatic attraction between the protonated PDMAEMA and positively charged acidic proteins(pepsin and BSA,whose isoelectric points were below the pK_(a) of PDMAEMA)would drive the intensive adsorption(at pH 3,I=10^(-3)mol·L^(-1)for pepsin,and pH 5,I=10^(-5)mol·L^(-1)for BSA),while desorption was dominated by the hydrophilic PMOXA when PDMAEMA was shrinking(at pH 7,I=10^(-1)mol·L^(-1)for pepsin,and pH 9,I=10^(-1)mol·L^(-1)for BSA).Furthermore,the isoelectric precipitation led to the adsorption of neutral protein(γ-globulin,whose isoelectric point was near the pK_a of PDMAEMA)at pH 7,I=10^(-5)mol·L^(-1),while electrostatic repulsion and antifouling PMOXA triggered the desorption of y-globulin at pH 3,I-10^(-1)mol·L^(-1).However,alkaline protein(lysozyme,whose isoelectric point was higher than the pK_(a) of PDMAEMA)exhibited slight adsorption on PMOXA/PDMAEMA mixed brushes under test conditions,regardless of whether PMOXA or PDMAEMA occupied the outermost layer.The antibacterial property of the mixed brushes against Escherichia coli was investigated.PMOXA/PDMAEMA mixed brushes showed significant bactericidal activity at pH 3,I=10^(-3)mol·L^(-1),while the rinse of pH 9,I=10^(-1)mol·L^(-1)solution could remove most of the residual bacteria.This work not only enables controlled adsorption of proteins with different isoelectric points but also ensures that the surface of the coating is minimized from bacterial contamination.展开更多
Three kinds of coplanar waveguides (CPWs) are designed and fabricated on different silicon substrates---common low-resistivity silicon substrate (LRS), LRS with a 3μm-thick silicon oxide interlayer, and high-resi...Three kinds of coplanar waveguides (CPWs) are designed and fabricated on different silicon substrates---common low-resistivity silicon substrate (LRS), LRS with a 3μm-thick silicon oxide interlayer, and high-resistivity silicon (HRS) substrate. The results show that the microwave loss of a CPW on LRS is too high to be used, but it can be greatly reduced by adding a thick interlayer of silicon oxide between the CPW transmission lines and the LRS.A CPW directly on HRS shows a loss lower than 2dB/cm in the range of 0-26GHz and the process is simple,so HRS is a more suitable CPW substrate.展开更多
The sliding electrical contact behavior of AuAgCu brush on Au plating was investigated at various normal loads and sliding speeds.The contact voltage drop and electrical noise between the two brushes were measured and...The sliding electrical contact behavior of AuAgCu brush on Au plating was investigated at various normal loads and sliding speeds.The contact voltage drop and electrical noise between the two brushes were measured and the resistance waveforms were recorded.The morphologies of the worn surfaces and wear debris of the brush and plating were observed.The results show that the contact voltage drop and electrical noise decrease with the addition of load whereas increase drastically with increasing sliding speed.With the electrical current in vacuum,the wear process of AuAgCu brush on Au plating involves adhesion,transfer of gold from the plating to the brush,rolling of wear debris between contact surfaces and arc-induced melt at the contact edge,and this gold-on-gold sliding electrical contact system is reliable within experiment period.展开更多
The paper is devoted to investigations on nanomechanical behaviors of biochips in label-free biodetections. The chip consists of Si-layer, Ti-layer, Au-layer and single-strand DNA (ssDNA) molecular brush biolayer im...The paper is devoted to investigations on nanomechanical behaviors of biochips in label-free biodetections. The chip consists of Si-layer, Ti-layer, Au-layer and single-strand DNA (ssDNA) molecular brush biolayer immobilized by self-assembly technology of thiol group. Unlike previous viewpoints, such as force-bending, entropy-bending and curvature electricity effect, etc., the piezoelectric effect of the biopolymer brush layer is viewed as the main factor that induces nanomechanical bending of biochips, and a classical macroscopic piezoelectric constitutive relation is used to describe the piezoelectric effect. A new laminated cantilever beam model with a piezoelectric biolayer in continuum mechanics, the linearized Poisson-Boltzmann equation in statistical mechanics and the scaling method in polyelectrolyte brush theory are combined to es- tablish a relationship between the nanomechanical deflection of DNA chips and the factors such as nanoscopic structural features of ssDNA molecules, buffer salt concentration, macroscopic mechanical/piezoelectric parameters of DNA chips etc. Curve fitting of experimental data shows that the sign of the piezoelectric constant of the biolayer may control the deflection direction of DNA chips during the packaging process.展开更多
BACKGROUND: A previous report has identified a significantly higher sensitivity of cancer detection for dedicated grasping basket than brushing at endoscopic retrograde cholangiopancreato- graphy (ERCP). This study...BACKGROUND: A previous report has identified a significantly higher sensitivity of cancer detection for dedicated grasping basket than brushing at endoscopic retrograde cholangiopancreato- graphy (ERCP). This study aimed to compare the diagnostic accuracy of Geenen brush and Dormia basket cytology in the differential diagnosis of bile duct stricture. METHOD: The current study enrolled one hundred and fourteen patients who underwent ERCP with both Geenen brush and Dormia basket cytology for the differential diagnosis of bile duct stricture at our institution between January 2008 and December 2012. RESULTS: We adopted sequential performances of cytologic samplings by using initial Geenen brush and subsequent Dormia basket cytology in 59 patients and initial Dormia basket and subsequent Geenen brush cytology in 55 patients. Presampling balloon dilatations and biliary stentings for the stricture were performed in 17 (14.9%) and 107 patients (93.9%), respectively. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of Geenen brush cytology for the diagnosis of malignant bile duct stricture were 75.0%, 100.0%, 100.0%, 66.7% and 83.3%, respectively, and those of Dormia basket cytology were 64.5%, 100.0%, 100.0%, 58.5% and 76.3%, respectively (P=0.347 and 0.827 for sensitivity and accuracy, respectively). The good and excellent cellular yields (≥grade 2) were obtained by Geenen brush and Dormia basket cytology in 88 (77.2%) and 79 (69.3%) patients, respectively.CONCLUSION: The sensitivity, specificity and accuracy of biliary sampling with a Dormia basket are comparable to those with conventional Geenen brush cytology in the detection of malignant bile duct stricture.展开更多
AIM: To evaluate the sensitivity of brush cytology and forceps biopsy in a homogeneous patient group with hilar cholangiocarcinoma.METHODS: Brush cytology and forceps biopsy were routinely performed in patients with s...AIM: To evaluate the sensitivity of brush cytology and forceps biopsy in a homogeneous patient group with hilar cholangiocarcinoma.METHODS: Brush cytology and forceps biopsy were routinely performed in patients with suspected malignant biliary strictures. Fifty-eight consecutive patients undergoing endoscopic retrograde cholangio-pancreatography (ERCP) including forceps biopsy and brush cytology in patients with hilar cholangiocarcinoma between 1995-2005.RESULTS: Positive results for malignancy were obtained in 24/58 patients (41.4%) by brush cytology and in 31/58 patients (53.4%) by forceps biopsy. The combination of both techniques brush cytology and forceps biopsy resulted only in a minor increase in diagnostic sensitivity to 60.3% (35/58 patients). In 20/58 patients (34.5%), diagnosis were obtained by both positive cytology and positive histology, in 11/58 (19%) by positive histology (negative cytology) and only 4/58 patients (6.9%) were confirmed by positive cytology (negative histology).CONCLUSION: Brush cytology and forceps biopsy have only limited sensitivity for the diagnosis of malignant hilar tumors. In our eyes, additional diagnostic techniques should be evaluated and should become routine in patients with negative cytological and histological findings.展开更多
AIM: To evaluate the diagnostic yield(inflammatory activity) and efficiency(size of the biopsy specimen) of SpyGlassTM-guided biopsy vs standard brush cytology in patients with and without primary sclerosing cholangit...AIM: To evaluate the diagnostic yield(inflammatory activity) and efficiency(size of the biopsy specimen) of SpyGlassTM-guided biopsy vs standard brush cytology in patients with and without primary sclerosing cholangitis(PSC).METHODS: At the University Medical Center Mainz, Germany, 35 consecutive patients with unclear biliarylesions(16 patients) or long-standing PSC(19 patients) were screened for the study. All patients underwent a physical examination, lab analyses, and abdominal ultrasound. Thirty-one patients with non-PSC strictures or with PSC were scheduled to undergo endoscopic retrograde cholangiography(ERC) and subsequent per-oral cholangioscopy(POC). Standard ERC was initially performed, and any lesions or strictures were localized. POC was performed later during the same session. The Boston Scientific SpyGlass SystemTM(Natick, MA, United States) was used for choledochoscopy. The biliary tree was visualized, and suspected lesions or strictures were biopsied, followed by brush cytology of the same area. The study endpoints(for both techniques) were the degree of inflammation, tissue specimen size, and the patient populations(PSC vs non-PSC). Inflammatory changes were divided into three categories: none, low activity, and high activity. The specimen quantity was rated as low, moderate, or sufficient.RESULTS: SpyGlassTM imaging and brush cytology with material retrieval were performed in 29 of 31(93.5%) patients(23 of the 29 patients were male). The median patient age was 45 years(min, 20 years; max, 76 years). Nineteen patients had known PSC, and 10 showed non-PSC strictures. No procedure-related complications were encountered. However, for both methods, tissues could only be retrieved from 29 pa-tients. In cases of inflammation of the biliary tract, the diagnostic yield of the SpyGlassTM-directed biopsies was greater than that using brush cytology. More tissue material was obtained for the biopsy method than for the brush cytology method(P = 0.021). The biopsies showed significantly more inflammatory characteristics and greater inflammatory activity compared to the cy-tological investigation(P = 0.014). The greater quantity of tissue samples proved useful for both PSC and non-PSC patients.CONCLUSION: SpyGlassTM imaging can be recom-mended for proper inflammatory diagnosis in PSC pa-tients. However, its value in diagnosing dysplasia wasnot addressed in this study and requires further investi-gation.展开更多
OBJECTIVE: To assess the diagnostic value of endoscopic pancreatic duct brushing in detecting mutation of the K-ras gene at codon 12 in cytologic specimens from patients with pancreatic cancer. METHODS: Thirty-five pa...OBJECTIVE: To assess the diagnostic value of endoscopic pancreatic duct brushing in detecting mutation of the K-ras gene at codon 12 in cytologic specimens from patients with pancreatic cancer. METHODS: Thirty-five patients treated at Changhai Hospital, Shanghai between 1999 and 2001 were enrolled. Their cells obtained by pancreatic duct brushing during endoscopic retrograde tholangiopancreatography (ERCP) were suspended with phosphate buffer solution (PBS). DNA of the cells was extracted and mutation of the K-ras gene at codon 12 detected by means of PCR-SSCP. RESULTS: The K-ras gene mutation rate of pancreatic cancer was 70%, which was higher than that of chronic pancreatitis (14%, P<0.05). K-ras gene mutation was not found in patients with pancreatic cystorcarcinoma and duodenum carcinoma. As to the location of pancreatic cancer, no significant difference was observed between the head, the body and tail. The sensitivity, specificity, accuracy of pancreatic duct brushing in detecting pancreatic cancer was 70%, 94%, and 83%, respectively. CONCLUSION: K-ras analysis of pancreatic brushing samples is helpful in the diagnosis of patients with early pancreatic cancer.展开更多
Soldering of LD31 aluminum alloys using Sn-Pb solder paste after electric brush plating Ni and Cu coatings was investigated. The technology of electric brush plating Ni and Cu was studied and plating solution was deve...Soldering of LD31 aluminum alloys using Sn-Pb solder paste after electric brush plating Ni and Cu coatings was investigated. The technology of electric brush plating Ni and Cu was studied and plating solution was developed. The microstructure of the coatings, soldered joint and fracture face were analyzed using optic microscopy, SEM and EDX. The shear strength of soldered joint could reach as high as 26.83MPa. The results showed that reliable soldered joint could be obtained at 230℃, the adhesion of coatings and LD31 aluminum alloy substrate was high enough to bear the thermal process in the soldering.展开更多
Ni-matrix composite coating containing AI2O3 nano-particles is prepared by brush plating. The effects of the nano-particles on the microstructure, microhardness and tribological properties of the composite coating und...Ni-matrix composite coating containing AI2O3 nano-particles is prepared by brush plating. The effects of the nano-particles on the microstructure, microhardness and tribological properties of the composite coating under the lubrication of a diesel oil containing sand are investigated. The results show that the microstructure of the composite coating is finer than that of the pure nickel coating due to the codeposition of the nano-particles. When the nano-particle concentration in the electroplating bath reaches 20 g/L, the microhardness, and wear resistance of the composite coating is as much as 1.6 times and 1.3-2.5 times of those of the pure nickel coating respectively. The main hardening mechanism of the composite coating is superfine crystal grain strengthening and dispersion strengthening. The composite coating is characterized by scuffing as it slides against Si3N4 under the present test conditions.展开更多
Surface-attached micropattemed polyelectrolyte brushes on planar solid surfaces are generated using free radical polymerization photo-initiated by self-assembled initiator monolayers. It is shown that the formed patte...Surface-attached micropattemed polyelectrolyte brushes on planar solid surfaces are generated using free radical polymerization photo-initiated by self-assembled initiator monolayers. It is shown that the formed patterns can be either negative or positive with different patterning processes.展开更多
An analysis of the efficiency of the ginning of cotton fibers with two saw cylinders has been carried out. In comparison to a one-cylinder machine, the 2 cylinder approach can help to preserve the natural characterist...An analysis of the efficiency of the ginning of cotton fibers with two saw cylinders has been carried out. In comparison to a one-cylinder machine, the 2 cylinder approach can help to preserve the natural characteristics of cotton fiber and seeds. This technology allows economizing electricity and decreasing damage to fiber and also increases the productivity of the machine.展开更多
The composite coating nano SiO 2/Ni was prepared by co depositing nano SiO 2 particles with pure nickel through electro brush plating. By taking into account the effect of microstructure, heat treatment and loa...The composite coating nano SiO 2/Ni was prepared by co depositing nano SiO 2 particles with pure nickel through electro brush plating. By taking into account the effect of microstructure, heat treatment and load on the contact fatigue life, the anti contact fatigue behavior of the composite coating was examined and compared with that of nickel coating. As a result, the contact fatigue life decreased with the increasing of load. The contact fatigue lives of nano SiO 2/Ni coating were 16.5% and 45.2% higher than those of nickel coating respectively under the loads of 60 N and 140 N, and 326.3% higher than its counterpart of nickel coating after annealed under the load of 140 N. From the SEM image of fatigue fracture, it has been observed that the fatigue fracture of the composite coating initiated in the sub surface as well as at the track surface due to the huddling of units, and propagated along the interface between grain units.展开更多
基金Project(59972009)supported by the National Natural Science Foundation of China
文摘Four kinds of high-resistivity carbon brushes with MoS2 contents of 0%,2%,4%and 6%(mass fraction)were prepared, respectively.Wear tests of brushes were conducted on an alternate current(AC)motor.Scanning electron microscopy(SEM)and energy dispersive X-ray analysis(EDS)were used to analyze the worn surface of brushes,and a thermocouple was used to measure the bulk temperature of the brush.The results show that wear rate of brush made without MoS2 in 10%relative humidity(RH)is two times larger than that in 50%RH,whereas the wear rates change little for the brushes made with MoS2.The wear of brushes has much to do with the surface film.In low humidity,the surface film can not be formed for the former brush while a sulfur layer can be formed for the latter brushes,which can reduce sparks,frictional heat and wear rate,and play a role like the water film in high humidity.
基金Financial support for this work, provided by the National Natural Science Foundation of China (No. 51174195)the Graduate Student Scientific Research Innovation Project of the Jiangsu Province Ordinary University (No. CXZZ12_0954)the Research Foundation of the State Key Laboratory of Coal Resources and Mine Safety (No. SKLCRSM08X04)
文摘In order to avoid the deep-well oil shale roadway being deformed, damaged, or difficult to maintain after excavating and supporting in Haishiwan coal mine, this paper has analyzed the characteristics of the deformed roadway and revealed its failure mechanism by taking comprehensively the methods of field geological investigation, displacement monitoring of surrounding rock, rock properties and hydration properties experiments and field application tests. Based on this work, the high-resistance controlled yielding supporting principle is proposed, which is: to "resist" by high pre-tightening force and high stiff- ness in the early stage, to "yield" by making use of the controlled deformation of a yielding tube in the middle stage, and to "fix" by applying total-section Gunite in the later stage. A high-resistance controlled yielding supporting technique of "high pre-tightening force yielding anchor bolt + small-bore pre-tight- ening force anchor cable + rebar ladder beam + rhombic metal mesh + lagging gunite" has been estab- lished, and industrial on site testing implemented. The practical results show that the high-resistance controlled yielding supporting technique can effectively control the large deformation and long-time rheology of deep-well oil shale roadways and can provide beneficial references for the maintenance of other con-generic roadways.Deep-well Oil shale
基金supported by the Chinese PLA General Armament Department under Grant No.51318020305
文摘In recent years, microstrip antennas have been more widely applied in satellite communications, mobile phones, unmanned aerial vehicle (UAV), and weapons. A micro-electro-mechanical systems-based (MEMS-based) high-resistance silicon C-band microstrip antenna array has been designed for the intelligent ammunition. The center frequency is 4.5 GHz. A cavity has been designed in substrate to reduce the dielectric constant of silicon and high-resistance silicon has been used as the material of substrate to improve the gain of antenna. It is very easy to be manufactured by using MEMS technology because of the improved structure of the antenna. The results show that the gain of the antenna is 8 dB and voltage standing wave ratio (VSWR) is less than 2 by the analysis and simulation in high freauencv structure simulator (HFSS).
文摘For large generators, the problem of high-resistance grounding method and the advantages of resonance, grounding method are discussed in detail, and an overall comparison is given in this paper. It is recommended that the latter should be adopted so as to increase the operation reliability of large generators and power systems.
基金the Qatar National Research Fund for funding this work through NPRP(10-0127-170270,acknowledged under the grant code KK-2018-008).
文摘Confronting the severe health threats and environmental impacts of Cr(Ⅵ) in aquatic environments demands innovative and effective remediation approaches. In this study, Graphene oxide(GO)-decorated poly(dimethyl amino ethyl methacrylate)(PDMAEMA) brush nanocomposites(GOP1, GOP2, GOP3, and GOP4) were fabricated using atom transfer radical polymerization(ATRP) by the “graft from” method.The resulting nanocomposites were utilized for removing Cr(Ⅵ) with good adsorption performance due to the electrostatic interaction of protonated nitrogen groups in the brush chains with negatively charged particles in the solution. The kinetic model of pseudo-second-order best represented the contaminants' adsorption characteristics. The Weber-Morris model further indicated that surface adsorption and intraparticle diffusion mechanisms primarily controlled the adsorption procedure. Additionally, the Langmuir and Temkin isotherm models were found to most accurately represent the adsorption characteristics of the pollutants on the nanocomposites, and GOP4 can achieve the maximum adsorption capacity of 164.4 mg·g^(-1). The adsorbents' capacity maintains above 85% after five cycles of adsorption-desorption. The nanocomposites in this study demonstrate promising potential for eliminating Cr(Ⅵ) from aqueous solutions.
基金the financial support of the National Natural Science Foundation of China(21674102)。
文摘Herein,binary mixed brushes consisting of poly(2-methyl-2-oxazoline)(PMOXA)and poly(2-(dimethylamine)ethyl methacrylate)(PDMAEMA)with different chain lengths were fabricated by successive grafting of NH_(2)-terminated PMOXA and SH-terminated PDMAEMA onto polydopamine-anchored substrates.The mixed-brush coating was characterized by variable-angle spectroscopic ellipsometry,X-ray photoelectron spectroscopy,Fourier transform infrared spectroscopy,zeta potential measurements,water contact angle,and atomic force microscopy.The mixed brushes showed tunable surface charge,wettability,and surface roughness,depending on the degree of PDMAEMA swelling under varying pH and ionic strength(Ⅰ).Then the adsorption behaviors of pepsin,bovine serum albumin(BSA),γ-globulin,and lysozyme,four very different proteins with regard to isoelectric point,on the mixed brushes coating were studied by using fluorescence microscopy and surface plasmon resonance.When the chain length of PDMAEMA was about twice as long as PMOXA,the mixed brushes not only had high adsorption capacity for pepsin,BSA,and y-globulin but also had a desorption efficiency of 86.9%,87.1%,and 93.5%,respectively.It is explained that electrostatic attraction between the protonated PDMAEMA and positively charged acidic proteins(pepsin and BSA,whose isoelectric points were below the pK_(a) of PDMAEMA)would drive the intensive adsorption(at pH 3,I=10^(-3)mol·L^(-1)for pepsin,and pH 5,I=10^(-5)mol·L^(-1)for BSA),while desorption was dominated by the hydrophilic PMOXA when PDMAEMA was shrinking(at pH 7,I=10^(-1)mol·L^(-1)for pepsin,and pH 9,I=10^(-1)mol·L^(-1)for BSA).Furthermore,the isoelectric precipitation led to the adsorption of neutral protein(γ-globulin,whose isoelectric point was near the pK_a of PDMAEMA)at pH 7,I=10^(-5)mol·L^(-1),while electrostatic repulsion and antifouling PMOXA triggered the desorption of y-globulin at pH 3,I-10^(-1)mol·L^(-1).However,alkaline protein(lysozyme,whose isoelectric point was higher than the pK_(a) of PDMAEMA)exhibited slight adsorption on PMOXA/PDMAEMA mixed brushes under test conditions,regardless of whether PMOXA or PDMAEMA occupied the outermost layer.The antibacterial property of the mixed brushes against Escherichia coli was investigated.PMOXA/PDMAEMA mixed brushes showed significant bactericidal activity at pH 3,I=10^(-3)mol·L^(-1),while the rinse of pH 9,I=10^(-1)mol·L^(-1)solution could remove most of the residual bacteria.This work not only enables controlled adsorption of proteins with different isoelectric points but also ensures that the surface of the coating is minimized from bacterial contamination.
文摘Three kinds of coplanar waveguides (CPWs) are designed and fabricated on different silicon substrates---common low-resistivity silicon substrate (LRS), LRS with a 3μm-thick silicon oxide interlayer, and high-resistivity silicon (HRS) substrate. The results show that the microwave loss of a CPW on LRS is too high to be used, but it can be greatly reduced by adding a thick interlayer of silicon oxide between the CPW transmission lines and the LRS.A CPW directly on HRS shows a loss lower than 2dB/cm in the range of 0-26GHz and the process is simple,so HRS is a more suitable CPW substrate.
文摘The sliding electrical contact behavior of AuAgCu brush on Au plating was investigated at various normal loads and sliding speeds.The contact voltage drop and electrical noise between the two brushes were measured and the resistance waveforms were recorded.The morphologies of the worn surfaces and wear debris of the brush and plating were observed.The results show that the contact voltage drop and electrical noise decrease with the addition of load whereas increase drastically with increasing sliding speed.With the electrical current in vacuum,the wear process of AuAgCu brush on Au plating involves adhesion,transfer of gold from the plating to the brush,rolling of wear debris between contact surfaces and arc-induced melt at the contact edge,and this gold-on-gold sliding electrical contact system is reliable within experiment period.
基金Project supported by the Outstanding Youth Program of Shanghai Municipal Commission of Education(No.04YQHB088)the Shanghai Leading Academic Discipline Project(No.Y0103).
文摘The paper is devoted to investigations on nanomechanical behaviors of biochips in label-free biodetections. The chip consists of Si-layer, Ti-layer, Au-layer and single-strand DNA (ssDNA) molecular brush biolayer immobilized by self-assembly technology of thiol group. Unlike previous viewpoints, such as force-bending, entropy-bending and curvature electricity effect, etc., the piezoelectric effect of the biopolymer brush layer is viewed as the main factor that induces nanomechanical bending of biochips, and a classical macroscopic piezoelectric constitutive relation is used to describe the piezoelectric effect. A new laminated cantilever beam model with a piezoelectric biolayer in continuum mechanics, the linearized Poisson-Boltzmann equation in statistical mechanics and the scaling method in polyelectrolyte brush theory are combined to es- tablish a relationship between the nanomechanical deflection of DNA chips and the factors such as nanoscopic structural features of ssDNA molecules, buffer salt concentration, macroscopic mechanical/piezoelectric parameters of DNA chips etc. Curve fitting of experimental data shows that the sign of the piezoelectric constant of the biolayer may control the deflection direction of DNA chips during the packaging process.
基金supported by a grant from JEIL Pharmaceuticals (Seoul, Korea)
文摘BACKGROUND: A previous report has identified a significantly higher sensitivity of cancer detection for dedicated grasping basket than brushing at endoscopic retrograde cholangiopancreato- graphy (ERCP). This study aimed to compare the diagnostic accuracy of Geenen brush and Dormia basket cytology in the differential diagnosis of bile duct stricture. METHOD: The current study enrolled one hundred and fourteen patients who underwent ERCP with both Geenen brush and Dormia basket cytology for the differential diagnosis of bile duct stricture at our institution between January 2008 and December 2012. RESULTS: We adopted sequential performances of cytologic samplings by using initial Geenen brush and subsequent Dormia basket cytology in 59 patients and initial Dormia basket and subsequent Geenen brush cytology in 55 patients. Presampling balloon dilatations and biliary stentings for the stricture were performed in 17 (14.9%) and 107 patients (93.9%), respectively. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of Geenen brush cytology for the diagnosis of malignant bile duct stricture were 75.0%, 100.0%, 100.0%, 66.7% and 83.3%, respectively, and those of Dormia basket cytology were 64.5%, 100.0%, 100.0%, 58.5% and 76.3%, respectively (P=0.347 and 0.827 for sensitivity and accuracy, respectively). The good and excellent cellular yields (≥grade 2) were obtained by Geenen brush and Dormia basket cytology in 88 (77.2%) and 79 (69.3%) patients, respectively.CONCLUSION: The sensitivity, specificity and accuracy of biliary sampling with a Dormia basket are comparable to those with conventional Geenen brush cytology in the detection of malignant bile duct stricture.
文摘AIM: To evaluate the sensitivity of brush cytology and forceps biopsy in a homogeneous patient group with hilar cholangiocarcinoma.METHODS: Brush cytology and forceps biopsy were routinely performed in patients with suspected malignant biliary strictures. Fifty-eight consecutive patients undergoing endoscopic retrograde cholangio-pancreatography (ERCP) including forceps biopsy and brush cytology in patients with hilar cholangiocarcinoma between 1995-2005.RESULTS: Positive results for malignancy were obtained in 24/58 patients (41.4%) by brush cytology and in 31/58 patients (53.4%) by forceps biopsy. The combination of both techniques brush cytology and forceps biopsy resulted only in a minor increase in diagnostic sensitivity to 60.3% (35/58 patients). In 20/58 patients (34.5%), diagnosis were obtained by both positive cytology and positive histology, in 11/58 (19%) by positive histology (negative cytology) and only 4/58 patients (6.9%) were confirmed by positive cytology (negative histology).CONCLUSION: Brush cytology and forceps biopsy have only limited sensitivity for the diagnosis of malignant hilar tumors. In our eyes, additional diagnostic techniques should be evaluated and should become routine in patients with negative cytological and histological findings.
文摘AIM: To evaluate the diagnostic yield(inflammatory activity) and efficiency(size of the biopsy specimen) of SpyGlassTM-guided biopsy vs standard brush cytology in patients with and without primary sclerosing cholangitis(PSC).METHODS: At the University Medical Center Mainz, Germany, 35 consecutive patients with unclear biliarylesions(16 patients) or long-standing PSC(19 patients) were screened for the study. All patients underwent a physical examination, lab analyses, and abdominal ultrasound. Thirty-one patients with non-PSC strictures or with PSC were scheduled to undergo endoscopic retrograde cholangiography(ERC) and subsequent per-oral cholangioscopy(POC). Standard ERC was initially performed, and any lesions or strictures were localized. POC was performed later during the same session. The Boston Scientific SpyGlass SystemTM(Natick, MA, United States) was used for choledochoscopy. The biliary tree was visualized, and suspected lesions or strictures were biopsied, followed by brush cytology of the same area. The study endpoints(for both techniques) were the degree of inflammation, tissue specimen size, and the patient populations(PSC vs non-PSC). Inflammatory changes were divided into three categories: none, low activity, and high activity. The specimen quantity was rated as low, moderate, or sufficient.RESULTS: SpyGlassTM imaging and brush cytology with material retrieval were performed in 29 of 31(93.5%) patients(23 of the 29 patients were male). The median patient age was 45 years(min, 20 years; max, 76 years). Nineteen patients had known PSC, and 10 showed non-PSC strictures. No procedure-related complications were encountered. However, for both methods, tissues could only be retrieved from 29 pa-tients. In cases of inflammation of the biliary tract, the diagnostic yield of the SpyGlassTM-directed biopsies was greater than that using brush cytology. More tissue material was obtained for the biopsy method than for the brush cytology method(P = 0.021). The biopsies showed significantly more inflammatory characteristics and greater inflammatory activity compared to the cy-tological investigation(P = 0.014). The greater quantity of tissue samples proved useful for both PSC and non-PSC patients.CONCLUSION: SpyGlassTM imaging can be recom-mended for proper inflammatory diagnosis in PSC pa-tients. However, its value in diagnosing dysplasia wasnot addressed in this study and requires further investi-gation.
文摘OBJECTIVE: To assess the diagnostic value of endoscopic pancreatic duct brushing in detecting mutation of the K-ras gene at codon 12 in cytologic specimens from patients with pancreatic cancer. METHODS: Thirty-five patients treated at Changhai Hospital, Shanghai between 1999 and 2001 were enrolled. Their cells obtained by pancreatic duct brushing during endoscopic retrograde tholangiopancreatography (ERCP) were suspended with phosphate buffer solution (PBS). DNA of the cells was extracted and mutation of the K-ras gene at codon 12 detected by means of PCR-SSCP. RESULTS: The K-ras gene mutation rate of pancreatic cancer was 70%, which was higher than that of chronic pancreatitis (14%, P<0.05). K-ras gene mutation was not found in patients with pancreatic cystorcarcinoma and duodenum carcinoma. As to the location of pancreatic cancer, no significant difference was observed between the head, the body and tail. The sensitivity, specificity, accuracy of pancreatic duct brushing in detecting pancreatic cancer was 70%, 94%, and 83%, respectively. CONCLUSION: K-ras analysis of pancreatic brushing samples is helpful in the diagnosis of patients with early pancreatic cancer.
文摘Soldering of LD31 aluminum alloys using Sn-Pb solder paste after electric brush plating Ni and Cu coatings was investigated. The technology of electric brush plating Ni and Cu was studied and plating solution was developed. The microstructure of the coatings, soldered joint and fracture face were analyzed using optic microscopy, SEM and EDX. The shear strength of soldered joint could reach as high as 26.83MPa. The results showed that reliable soldered joint could be obtained at 230℃, the adhesion of coatings and LD31 aluminum alloy substrate was high enough to bear the thermal process in the soldering.
基金This research was financially supported by the Major Project of National Natural Science Foundation of China(No.50235030)the National 973 Planning Project(No.G1999065009)+1 种基金the Science and Technology Cooperation Project between China and Poland Governments in 2002(No.2002M3)their supports are gratefully acknowledged.
文摘Ni-matrix composite coating containing AI2O3 nano-particles is prepared by brush plating. The effects of the nano-particles on the microstructure, microhardness and tribological properties of the composite coating under the lubrication of a diesel oil containing sand are investigated. The results show that the microstructure of the composite coating is finer than that of the pure nickel coating due to the codeposition of the nano-particles. When the nano-particle concentration in the electroplating bath reaches 20 g/L, the microhardness, and wear resistance of the composite coating is as much as 1.6 times and 1.3-2.5 times of those of the pure nickel coating respectively. The main hardening mechanism of the composite coating is superfine crystal grain strengthening and dispersion strengthening. The composite coating is characterized by scuffing as it slides against Si3N4 under the present test conditions.
文摘Surface-attached micropattemed polyelectrolyte brushes on planar solid surfaces are generated using free radical polymerization photo-initiated by self-assembled initiator monolayers. It is shown that the formed patterns can be either negative or positive with different patterning processes.
文摘An analysis of the efficiency of the ginning of cotton fibers with two saw cylinders has been carried out. In comparison to a one-cylinder machine, the 2 cylinder approach can help to preserve the natural characteristics of cotton fiber and seeds. This technology allows economizing electricity and decreasing damage to fiber and also increases the productivity of the machine.
基金SupportedbytheNational 973Project (No .G1 9990 65 0 0 9)andbyUK/ChinaScience&TechnologyCollaborationFund (No .2 0 0 2M3)
文摘The composite coating nano SiO 2/Ni was prepared by co depositing nano SiO 2 particles with pure nickel through electro brush plating. By taking into account the effect of microstructure, heat treatment and load on the contact fatigue life, the anti contact fatigue behavior of the composite coating was examined and compared with that of nickel coating. As a result, the contact fatigue life decreased with the increasing of load. The contact fatigue lives of nano SiO 2/Ni coating were 16.5% and 45.2% higher than those of nickel coating respectively under the loads of 60 N and 140 N, and 326.3% higher than its counterpart of nickel coating after annealed under the load of 140 N. From the SEM image of fatigue fracture, it has been observed that the fatigue fracture of the composite coating initiated in the sub surface as well as at the track surface due to the huddling of units, and propagated along the interface between grain units.