期刊文献+
共找到26篇文章
< 1 2 >
每页显示 20 50 100
Use of high-resolution X-ray computed tomography and 3D image analysis to quantify mineral dissemination and pore space in oxide copper ore particles 被引量:8
1
作者 Bao-hua Yang Ai-xiang Wu +2 位作者 Guillermo A.Narsilio Xiu-xiu Miao Shu-yue Wu 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2017年第9期965-973,共9页
Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle,... Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle, a cylindrical copper oxide ore sample (I center dot 4.6 mm x 5.6 mm) was scanned using high-resolution X-ray computed tomography (HRXCT), a nondestructive imaging technology, at a spatial resolution of 4.85 mu m. Combined with three-dimensional (3D) image analysis techniques, the main mineral phases and pore space were segmented and the volume fraction of each phase was calculated. In addition, the mass fraction of each mineral phase was estimated and the result was validated with that obtained using traditional techniques. Furthermore, the pore phase features, including the pore size distribution, pore surface area, pore fractal dimension, pore centerline, and the pore connectivity, were investigated quantitatively. The pore space analysis results indicate that the pore size distribution closely fits a log-normal distribution and that the pore space morphology is complicated, with a large surface area and low connectivity. This study demonstrates that the combination of HRXCT and 3D image analysis is an effective tool for acquiring 3D mineralogical and pore structural data. 展开更多
关键词 high-resolution X-ray computed tomography 3D image analysis ore particles mineral dissemination pore space
下载PDF
Coronary artery calcium score on low-dose computed tomography for lung cancer screening 被引量:4
2
作者 Teresa Arcadi Erica Maffei +6 位作者 Nicola Sverzellati Cesare Mantini Andrea I Guaricci Carlo Tedeschi Chiara Martini Ludovico La Grutta Filippo Cademartiri 《World Journal of Radiology》 CAS 2014年第6期381-387,共7页
AIM: To evaluate the feasibility of coronary artery calcium score(CACS) on low-dose non-gated chest CT(ngCCT).METHODS: Sixty consecutive individuals(30 males; 73 ± 7 years) scheduled for risk stratification by me... AIM: To evaluate the feasibility of coronary artery calcium score(CACS) on low-dose non-gated chest CT(ngCCT).METHODS: Sixty consecutive individuals(30 males; 73 ± 7 years) scheduled for risk stratification by means of unenhanced ECG-triggered cardiac computed to-mography(gCCT) underwent additional unenhanced ngCCT. All CT scans were performed on a 64-slice CT scanner(Somatom Sensation 64 Cardiac, Siemens, Germany). CACS was calculated using conventional methods/scores(Volume, Mass, Agatston) as previ-ously described in literature. The CACS value obtained were compared. The Mayo Clinic classification was used to stratify cardiovascular risk based on Agatston CACS. Differences and correlations between the two methods were compared. A P-value < 0.05 was considered sig-nificant.RESULTS: Mean CACS values were significantly higher for gCCT as compared to ngCCT(Volume: 418 ± 747 vs 332 ± 597; Mass: 89 ± 151 vs 78 ± 141; Agatston: 481 ± 854 vs 428 ± 776; P < 0.05). The correlation between the two values was always very high(Volume: r = 0.95; Mass: r = 0.97; Agatston: r = 0.98). Of the 6 patients with 0 Agatston score on gCCT, 2(33%) showed an Agatston score > 0 in the ngCCT. Of the 3 patients with 1-10 Agatston score on gCCT, 1(33%) showed an Agatston score of 0 in the ngCCT. Overall, 23(38%) patients were reclassified in a different car-diovascular risk category, mostly(18/23; 78%) shifting to a lower risk in the ngCCT. The estimated radiation dose was significantly higher for gCCT(DLP 115.8 ± 50.7 vs 83.8 ± 16.3; Effective dose 1.6 ± 0.7 mSv vs 1.2 ± 0.2 mSv; P < 0.01).CONCLUSION: CACS assessment is feasible on ngCCT; the variability of CACS values and the associated re-stratification of patients in cardiovascular risk groups should be taken into account. 展开更多
关键词 Coronary artery calcium score Lung cancer screening high-resolution computed tomography unenhanced chest computed tomography Cardiovascular risk stratification
下载PDF
Low-dose computed tomography with 4th-generation iterative reconstruction algorithm in assessment of oncologic patients 被引量:2
3
作者 Davide Ippolito Alessandra Silvia Casiraghi +3 位作者 Cammillo Talei Franzesi Davide Fior Franca Meloni Sandro Sironi 《World Journal of Gastrointestinal Oncology》 SCIE CAS 2017年第10期423-430,共8页
AIM To compare radiation dose and image quality of lowdose computed tomography(CT) protocol combined with hybrid-iterative reconstruction algorithm with standarddose CT examinations for follow-up of oncologic patients... AIM To compare radiation dose and image quality of lowdose computed tomography(CT) protocol combined with hybrid-iterative reconstruction algorithm with standarddose CT examinations for follow-up of oncologic patients. METHODS Fifty-one patients with known malignant diseases which underwent, during clinical follow-up, both standarddose and low-dose whole-body CT scans were enrolled. Low-dose CT was performed on 256-row scanner, with 120 kV and automated m A modulation, and iterative reconstruction algorithm. Standard-dose CT was performed on 16-rows scanner, with 120 kV, 200-400 m As(depending on patient weight). We evaluated density values and signal-to-noise ratio, along with image noise(SD), sharpness and diagnostic quality with 4-point scale.RESULTS Density values in liver, spleen and aorta were higher in lowdose images(liver 112.55 HU vs 103.90 HU, P < 0.001), as SD values in liver and spleen(liver 16.81 vs 14.41). Volumetric-Computed-Tomographic-Dose-Index(CTDIvol) and Dose-Length-Product(DLP) were significantly lower in low-dose CT as compared to standard-dose(DLP 1025.6 m Gy*cm vs 1429.2 m Gy*cm, P < 0.001) with overall dose reduction of 28.9%. Qualitative analysis did not reveal significant differences in image noise and diagnostic quality.CONCLUSION Automatic tube-current modulation combined with hybriditerative algorithm allows radiation dose reduction of 28.9% without loss of diagnostic quality, being useful in reducing dose exposure in oncologic patients. 展开更多
关键词 computed tomography low-dose computed tomography Tube current modulation Oncologic imaging Radiation dose
下载PDF
Quantitative evaluation of deep convolutional neural network-based image denoising for low-dose computed tomography
4
作者 Keisuke Usui Koichi Ogawa +3 位作者 Masami Goto Yasuaki Sakano Shinsuke Kyougoku Hiroyuki Daida 《Visual Computing for Industry,Biomedicine,and Art》 EI 2021年第1期199-207,共9页
To minimize radiation risk,dose reduction is important in the diagnostic and therapeutic applications of computed tomography(CT).However,image noise degrades image quality owing to the reduced X-ray dose and a possibl... To minimize radiation risk,dose reduction is important in the diagnostic and therapeutic applications of computed tomography(CT).However,image noise degrades image quality owing to the reduced X-ray dose and a possible unacceptably reduced diagnostic performance.Deep learning approaches with convolutional neural networks(CNNs)have been proposed for natural image denoising;however,these approaches might introduce image blurring or loss of original gradients.The aim of this study was to compare the dose-dependent properties of a CNN-based denoising method for low-dose CT with those of other noise-reduction methods on unique CT noise-simulation images.To simulate a low-dose CT image,a Poisson noise distribution was introduced to normal-dose images while convoluting the CT unit-specific modulation transfer function.An abdominal CT of 100 images obtained from a public database was adopted,and simulated dose-reduction images were created from the original dose at equal 10-step dose-reduction intervals with a final dose of 1/100.These images were denoised using the denoising network structure of CNN(DnCNN)as the general CNN model and for transfer learning.To evaluate the image quality,image similarities determined by the structural similarity index(SSIM)and peak signal-to-noise ratio(PSNR)were calculated for the denoised images.Significantly better denoising,in terms of SSIM and PSNR,was achieved by the DnCNN than by other image denoising methods,especially at the ultra-low-dose levels used to generate the 10%and 5%dose-equivalent images.Moreover,the developed CNN model can eliminate noise and maintain image sharpness at these dose levels and improve SSIM by approximately 10%from that of the original method.In contrast,under small dose-reduction conditions,this model also led to excessive smoothing of the images.In quantitative evaluations,the CNN denoising method improved the low-dose CT and prevented over-smoothing by tailoring the CNN model. 展开更多
关键词 Deep learning Convolutional neural network low-dose computed tomography DENOISING Image quality
下载PDF
Virtual Anatomy: The Dissecting Theatre of the Future—Implementation of Cinematic Rendering in a Large 8 K High-Resolution Projection Environment 被引量:1
5
作者 Franz A. Fellner Klaus Engel Christoph Kremer 《Journal of Biomedical Science and Engineering》 2017年第8期367-375,共9页
Modern computer techniques have been in use for several years to generate three-dimensional visualizations of human anatomy. Very good 3-D computer models of the human body are now available and used routinely in anat... Modern computer techniques have been in use for several years to generate three-dimensional visualizations of human anatomy. Very good 3-D computer models of the human body are now available and used routinely in anatomy instruction. These techniques are subsumed under the heading “virtual anatomy” to distinguish them from the conventional study of anatomy entailing cadavers and anatomy textbooks. Moreover, other imaging procedures (X-ray, angiography, CT and MR) are also used in virtual anatomy instruction. A recently introduced three-dimensional post-processing technique named Cinematic Rendering now makes it possible to use the output of routine CT and MR examinations as the basis for highly photo-realistic 3-D depictions of human anatomy. We have installed Cinematic Rendering (enabled for stereoscopy) in a high-definition 8K 3-D projection space that accommodates an audience of 150. The space’s projection surface measures 16 × 9 meters;images can be projected on both the front wall and the floor. A game controller can be used to operate Cinematic Rendering software so that it can generate interactive real-time depictions of human anatomy on the basis of CT and MR data sets. This prototype installation was implemented without technical problems;in day-to-day, real-world use over a period of 22 months, there were no impairments of service due to software crashes or other technical problems. We are already employing this installation routinely for educational offerings open to the public, courses for students in the health professions, and (continuing) professional education units for medical interns, residents and specialists—in, so to speak, the dissecting theater of the future. 展开更多
关键词 Virtual Anatomy Education CINEMATIC RENDERING (CR) Volume RENDERING (VR) high-resolution 3D Display computed tomography (CT) Magnetic Resonance (MR)
下载PDF
Cost-effectiveness of lung cancer screening by low-dose CT in China:a micro-simulation study 被引量:1
6
作者 Yihui Du Yanju Li +9 位作者 Grigory Sidorenkov Rozemarijn Vliegenthart Marjolein A.Heuvelmans Monique D.Dorrius Harry J.M.Groen Shiyuan Liu Li Fan Zhaoxiang Ye Marcel J.W.Greuter Geertruida H.de Bock 《Journal of the National Cancer Center》 2022年第1期18-24,共7页
Background:The effectiveness of lung cancer screening with low-dose computed tomography(LDCT)has been established.The current study evaluates the cost-effectiveness of lung cancer screening with LDCT in a general popu... Background:The effectiveness of lung cancer screening with low-dose computed tomography(LDCT)has been established.The current study evaluates the cost-effectiveness of lung cancer screening with LDCT in a general population in China.Methods:A previously validated micro-simulation model was used to simulate a cohort of men and women on a lifetime horizon in the presence and absence of LDCT screening.The modeling data were collected from numerous national and international sources.Simulated screening scenarios included different combinations of screening intervals and start and stop ages.Additional costs(valued in Chinese Yuan,CNY;1 USD=6.8976 CNY,1 EUR=7.8755 CNY in 2020),life-years gained(LYG)and mortality reduction due to screening were also determined.The costs and life-years were discounted by 3%.All results were scaled to 1,000 individuals.The average cost-effectiveness ratio(ACER)was calculated.A willingness-to-pay threshold of CNY 217.3k/LYG was considered.A healthcare system perspective was adopted.Results:Compared to no screening,lung cancer screening by LDCT in a general Chinese population yielded 21.0-36.7 LYG in men and 9.2-16.6 LYG in women across the scenarios.For men,biennial LDCT screening yielded an ACER of CNY 171.4k-306.3k/LYG relative to no screening.Biennial screening performed between 55 and 75 years of age was optimal at the defined threshold;it resulted in CNY 174.6k/LYG and a lung cancer mortality reduction of 9.1%,and this scenario had a 75%probability of being cost-effective.For women,the ACER ranged from CNY 364.2k to 1193.3k/LYG.Conclusions:In China,lung cancer screening with LDCT in the general population including never smokers could be cost-effective for men with 75%probability,but not for women.The optimal strategy for men would be performing biennial screening between 55 and 75 years of age. 展开更多
关键词 COST-EFFECTIVENESS low-dose computed tomography Lung neoplasm Mass screening Microsimulation model General population
下载PDF
Low-Dose High-Pitch Cardiac CT to Evaluate Abnormal Pacemaker Lead Position
7
作者 Baosheng Li Chongfu Jia 《World Journal of Cardiovascular Diseases》 2021年第9期434-438,共5页
Displacement of a cardiac pacemaker lead or myocardial perforation by a lead is an infrequent complication of pacemaker implantation. While standard cardiac CT is useful for diagnosing such complications when routine ... Displacement of a cardiac pacemaker lead or myocardial perforation by a lead is an infrequent complication of pacemaker implantation. While standard cardiac CT is useful for diagnosing such complications when routine examinations can not, the potential risks associated with exposure to the high doses of radiation used in CT are of concern. Here, we report three cases </span><span style="font-family:"white-space:normal;">in which pacemaker lead displacement or myocardial perforation was definitively diagnosed by l</span><span style="font-family:"white-space:normal;">ow-dose cardiac CT used in the high-pitch spiral mode, when other more routine examinations failed to suggest their occurrence.</span><span style="font-family:"white-space:normal;"> </span><span style="font-family:"white-space:normal;">The mean dose of radiation used for definitively diagnosing the three patients was relatively low (2.19 mSv). 展开更多
关键词 X-Ray computed tomography PACEMAKER LEAD low-dose
下载PDF
Pulmonary fungal infections after bone marrow transplantation: the value of high-resolution computed tomography in predicting their etiology 被引量:12
8
作者 LI Xiang-sheng ZHU Hong-xian +3 位作者 FAN Hong-xia ZHU Ling WANG Heng-xiang SONG Yun-long 《Chinese Medical Journal》 SCIE CAS CSCD 2011年第20期3249-3254,共6页
Background The correct diagnosis of etiology of fungal infection after bone marrow transplantation is very important to the choice of antifungal drugs and a premise for improvement of therapeutic efficacy. This study ... Background The correct diagnosis of etiology of fungal infection after bone marrow transplantation is very important to the choice of antifungal drugs and a premise for improvement of therapeutic efficacy. This study aimed to compare high-resolution computed tomography (HRCT) findings of the pulmonary fungal infections to determine whether the etiology of various fungal infections could be diagnosed with HRCT. Methods Eighty-five cases were enrolled. According to the pathogens responsible for fungal infections, the patients were classified into three groups including invasive aspergillosis (n=52), candidiasis (n=19) and cryptococcosis (n=14) groups. All the patients underwent HRCT scans. Two independent radiologists retrospectively analyzed the HRCT scans regarding CT patterns and distribution of lung abnormality. Results Most fungal infections in the three groups occurred in the neutropenic phase. There was no significant difference in the constituent ratio of fungal infections at different phases after bone marrow transplantation among the three groups. Agreement between the two observers for all the CT characteristics of fungal infections was excellent (k 〉0.75). There was a significant difference in occurrence ratio of mass among the three groups (P=-0.02). Occurrence ratio of mass (43.3%, 13/30) in the group with invasive aspergillosis was higher than in each of other two groups (20.0%, 2/10; 14.3%, 1/7). There was no significant difference in other CT characteristics of nodules or masses; including number, margin, halo sign, cavitation and air-crescent sign. There was no significant difference in number, margin, air bronchogram and distribution of air-space consolidation. Conclusions The HRCT appearance of various pulmonary fungal infections has a great deal of overlap and is nonspecific. Mass is more common in invasive aspergillosis, which is helpful to the diagnosis of invasive aspergillosis after bone marrow transplantation. 展开更多
关键词 bone marrow transplantation fungal infection LUNG high-resolution computed tomography
原文传递
Use of low-dose computed tomography to assess pulmonary tuberculosis among healthcare workers in a tuberculosis hospital 被引量:8
9
作者 Wei He Bu-Dong Chen +8 位作者 Yan Lv Zhen Zhou Jin-Ping Xu Ping-Xin Lv Xin-Hua Zhou Feng-Gang Ning Cheng-Hai Li Dong-Po Wang Jie Zheng 《Infectious Diseases of Poverty》 SCIE 2017年第1期588-597,共10页
Background:According to the World Health Organization,China is one of 22 countries with serious tuberculosis(TB)infections and one of the 27 countries with serious multidrug-resistant TB strains.Despite the decline of... Background:According to the World Health Organization,China is one of 22 countries with serious tuberculosis(TB)infections and one of the 27 countries with serious multidrug-resistant TB strains.Despite the decline of tuberculosis in the overall population,healthcare workers(HCWs)are still at a high risk of infection.Compared with high-income countries,the TB prevalence among HCWs is higher in low-and middle-income countries.Low-dose computed tomography(LDCT)is becoming more popular due to its superior sensitivity and lower radiation dose.However,there have been no reports about active pulmonary tuberculosis(PTB)among HCWs as assessed with LDCT.The purposes of this study were to examine PTB statuses in HCWs in hospitals specializing in TB treatment and explore the significance of the application of LDCT to these workers.Methods:This study retrospectively analysed the physical examination data of healthcare workers in the Beijing Chest Hospital from September 2012 to December 2015.Low-dose lung CT examinations were performed in all cases.The comparisons between active and inactive PTB according to the CT findings were made using the Pearson chi-square test or the Fisher’s exact test.Comparisons between the incidences of active PTB in high-risk areas and non-high-risk areas were performed using the Pearson chi-square test.Analyses of active PTB were performed according to different ages,numbers of years on the job,and the risks of the working areas.Active PTB as diagnosed by the LDCT examinations alone was compared with the final comprehensive diagnoses,and the sensitivity and positive predictive value were calculated.Results:A total of 1012 participants were included in this study.During the 4-year period of medical examinations,active PTB was found in 19 cases,and inactive PTB was found in 109 cases.The prevalence of active PTB in the participants was 1.24%,0.67%,0.81%,and 0.53%for years 2012 to 2015.The corresponding incidences of active PTB among the tuberculosis hospital participants were 0.86%,0.41%,0.54%,and 0.26%.Most HCWs with active TB(78.9%,15/19)worked in the high-risk areas of the hospital.There was a significant difference in the incidences of active PTB between the HCWs who worked in the high-risk and non-high-risk areas(odds ratio[OR],14.415;95%confidence interval(CI):4.733-43.896).Comparisons of the CT signs between the active and inactive groups via chi-square tests revealed that the tree-in-bud,cavity,fibrous shadow,and calcification signs exhibited significant differences(P=0.000,0.021,0.001,and 0.024,respectively).Tree-in-bud and cavity opacities suggest active pulmonary tuberculosis,whereas fibrous shadow and calcification opacities are the main features of inactive pulmonary tuberculosis.Comparison with the final comprehensive diagnoses revealed that the sensitivity and positive predictive value of the diagnoses of active PTB based on LDCT alone were 100%and 86.4%,respectively.Conclusions:Healthcare workers in tuberculosis hospitals are a high-risk group for active PTB.Yearly LDCT examinations of such high-risk groups are feasible and necessary. 展开更多
关键词 TUBERCULOSIS PULMONARY Active tuberculosis Healthcare workers low-dose computed tomography computed tomography
原文传递
Evaluation with low-dose dual-phase helical computed tomography of patients with thyroid lesions 被引量:3
10
作者 Li Lin Wang Yong +6 位作者 Zhao Yanfeng Zou Shuangmei Lin Meng Yu Xiaoduo Tang Wei Zhou Chunwu Luo Dehong 《Chinese Medical Journal》 SCIE CAS CSCD 2014年第22期3937-3943,共7页
Background The incidence of thyroid cancer has been increasing.Our aim was to evaluate the efficacy of low-dose dualphase helical computed tomography (CT) in the characterization of thyroid lesions,and to discuss th... Background The incidence of thyroid cancer has been increasing.Our aim was to evaluate the efficacy of low-dose dualphase helical computed tomography (CT) in the characterization of thyroid lesions,and to discuss the relationship between image characteristics and their pathology.Methods One hundred and six patients with thyroid lesions underwent low-dose dual-phase helical CT after the injection of contrast material.CT scans were obtained at arterial and venous phase with delays of 25 and 65 seconds,and tube current of 60 and 120 mA,respectively.The attenuation change in the lesion between the arterial and venous phase was analyzed and categorized as "increased," "decreased," "mixed" or "no change." Results Histopathologic diagnosis was obtained by surgery in 106 patients (115 lesions).Of the 106 patients,45 had nodular goiter,5 thyroid adenoma,6 thyroiditis,and 50 papillary thyroid carcinoma (PTC) (59 lesions).The attenuation value showed a significant difference (P <0.05) between the arterial and venous phase for the high attenuation area.There was statistical significant difference in terms of attenuation value in high attenuation areas at both phases and in low attenuation areas on arterial phase between nodular goiter and PTC (P <0.05).However,there was no significant difference in attenuation value between adenoma and PTC.Twenty-nine cases (76.3%) of goiter manifested mixed type,3 cases (3/5) of adenoma showed decreased type,6 cases (6/6) of thyroiditis showed increased type,and 55 cases (93.2%) of PTC showed decreased type attenuation.The sensitivity,specificity for thyroid carcinoma by dual-phase CT were 94.9% and 80.4% respectively.The overall diagnostic accuracy for thyroid lesions by dual-phase CT was 87.8%.Conclusions The performance of dual-phase helical CT is related to the pathological structure of the lesions.The analysis of enhancement patterns by using dual-phase helical CT will be helpful in the differential diagnosis of thyroid lesions. 展开更多
关键词 thyroid lesions low-dose DUAL-PHASE computed tomography
原文传递
Accuracy of baseline low-dose computed tomography lung cancer screening: a systematic review and meta-analysis 被引量:1
11
作者 Lanwei Guo Yue Yu +6 位作者 Funa Yang Wendong Gao Yu Wang Yao Xiao Jia Du Jinhui Tian Haiyan Yang 《Chinese Medical Journal》 SCIE CAS CSCD 2023年第9期1047-1056,共10页
Background:Screening using low-dose computed tomography(LDCT)is a more effective approach and has the potential to detect lung cancer more accurately.We aimed to conduct a meta-analysis to estimate the accuracy of pop... Background:Screening using low-dose computed tomography(LDCT)is a more effective approach and has the potential to detect lung cancer more accurately.We aimed to conduct a meta-analysis to estimate the accuracy of population-based screening studies primarily assessing baseline LDCT screening for lung cancer.Methods:MEDLINE,Excerpta Medica Database,and Web of Science were searched for articles published up to April 10,2022.According to the inclusion and exclusion criteria,the data of true positives,false-positives,false negatives,and true negatives in the screening test were extracted.Quality Assessment of Diagnostic Accuracy Studies-2 was used to evaluate the quality of the literature.A bivariate random effects model was used to estimate pooled sensitivity and specificity.The area under the curve(AUC)was calculated by using hierarchical summary receiver-operating characteristics analysis.Heterogeneity between studies was measured using the Higgins I 2 statistic,and publication bias was evaluated using a Deeks’funnel plot and linear regression test.Results:A total of 49 studies with 157,762 individuals were identified for the final qualitative synthesis;most of them were from Europe and America(38 studies),ten were from Asia,and one was from Oceania.The recruitment period was 1992 to 2018,and most of the subjects were 40 to 75 years old.The analysis showed that the AUC of lung cancer screening by LDCT was 0.98(95%CI:0.96-0.99),and the overall sensitivity and specificity were 0.97(95%CI:0.94-0.98)and 0.87(95%CI:0.82-0.91),respectively.The funnel plot and test results showed that there was no significant publication bias among the included studies.Conclusions:Baseline LDCT has high sensitivity and specificity as a screening technique for lung cancer.However,long-term follow-up of the whole study population(including those with a negative baseline screening result)should be performed to enhance the accuracy of LDCT screening. 展开更多
关键词 Lung cancer low-dose computed tomography SCREENING Sensitivity SPECIFICITY META-ANALYSIS
原文传递
A NONLOCAL KRONECKER-BASIS-REPRESENTATION METHOD FOR LOW-DOSE CT SINOGRAM RECOVERY
12
作者 Jian Lu Huaxuan Hu +4 位作者 Yuru Zou Zhaosong Lu Xiaoxia Liu Keke Zu Lin Li 《Journal of Computational Mathematics》 SCIE CSCD 2024年第4期1080-1108,共29页
Low-dose computed tomography(LDCT)contains the mixed noise of Poisson and Gaus-sian,which makes the image reconstruction a challenging task.In order to describe the statistical characteristics of the mixed noise,we ad... Low-dose computed tomography(LDCT)contains the mixed noise of Poisson and Gaus-sian,which makes the image reconstruction a challenging task.In order to describe the statistical characteristics of the mixed noise,we adopt the sinogram preprocessing as a stan-dard maximum a posteriori(MAP).Based on the fact that the sinogram of LDCT has non-local self-similarity property,it exhibits low-rank characteristics.The conventional way of solving the low-rank problem is implemented in matrix forms,and ignores the correlations among similar patch groups.To avoid this issue,we make use of a nonlocal Kronecker-Basis-Representation(KBR)method to depict the low-rank problem.A new denoising model,which consists of the sinogram preprocessing for data fidelity and the nonlocal KBR term,is developed in this work.The proposed denoising model can better illustrate the generative mechanism of the mixed noise and the prior knowledge of the LDCT.Nu-merical results show that the proposed denoising model outperforms the state-of-the-art algorithms in terms of peak-signal-to-noise ratio(PSNR),feature similarity(FSIM),and normalized mean square error(NMSE). 展开更多
关键词 low-dose computed tomography Kronecker-basis-representation Low-rank imation.Noise-generating-mechanism
原文传递
Assessment of the efficacy of reduced-radiation noncontrast computed tomography scan compared with the standard noncontrast computed tomography scan for detecting urolithiasis:A prospective single-center study
13
作者 Gaurav Aggarwal Samiran Das Adhikary 《Current Urology》 2023年第1期18-24,共7页
Background:Noncontrast computed tomography(CT)scan of the kidneys,ureter and bladder is the standard investigative modality for diagnosing and following up patients with urolithiasis.With each scan,a patient receives ... Background:Noncontrast computed tomography(CT)scan of the kidneys,ureter and bladder is the standard investigative modality for diagnosing and following up patients with urolithiasis.With each scan,a patient receives radiation of 18-34 mGy.Dose considerations become pertinent because of a 10%lifetime incidence rate and higher than 50%risk of recurrence,necessitating repeated imaging in the lifetime of a stone former.Hence,this study aimed to assess the sensitivity of"reduced-radiation"CT imaging by altering scan settings to lower than the"standard"norms.Materials and methods:Altogether,222 patients(255"kidney-ureter"stone-bearing units or"renal units")with urolithiasis and patients undergoing CT for other reasons with incidental findings of renal/ureteric calculi between 2017 and 2019 were included.All patients were subjected to 3 sequential scans at tube current settings of 250 mA(CT-N/Standard),100 mA(CT-100),and 50 mA(CT-50)at a constant voltage of 120 kV.Their clinicodemographic and radiological findings were recorded and assessed for significance.Results:Of the 255 renal units,117 were between 30 and 44 years of age,75%were men.Of the 255 patients,178(70.1%)reported a first stone episode and 77 had recurrence.Lower ureteric calculi were predominant(40.4%).All calculi were identified on CT-N;CT-100 failed to detect calculi in 1 patient,and CT-50 failed in 3 patients,where all calculi were<3 mm in size.Meanwhile,none were undetected among patients with obesity.The sensitivity was 99.61%for the CT-100 and 98.82%for the CT-50,which indicated a 2.5 and 5 times lower radiation and dose/length,respectively,than CT-N.Conclusions:The reduced-radiation CT scan is safe,sensitive,and accurate for the diagnosis and follow-up of patients with urolithiasis with significantly lower radiation exposures.Our study lays the foundation to accept low-dose CT in general and CT-50 in particular,as the new"standard of care,"and attempt further dose reduction without loss of diagnostic efficacy. 展开更多
关键词 low-dose computed tomography scan Reduced-radiation computed tomography scan Reduced-radiation imaging Ureteric colic UROLITHIASIS
原文传递
Pulmonary involvement in inflammatory bowel disease 被引量:15
14
作者 Aydin Yilmaz Nilgün Yilmaz Demirci +4 位作者 Derya Hosgün Enver ner Yurdanur Erdogan Atila Gkek Atalay aglar 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第39期4952-4957,共6页
AIM:To determine the relationship of pulmonary abnormalities and bowel disease activity in inflammatory bowel disease(IBD).METHODS:Thirty ulcerative colitis(UC)and nine Crohn's disease patients,and 20 control subj... AIM:To determine the relationship of pulmonary abnormalities and bowel disease activity in inflammatory bowel disease(IBD).METHODS:Thirty ulcerative colitis(UC)and nine Crohn's disease patients,and 20 control subjects were enrolled in this prospective study.Detailed clinical information was obtained.Extent and activity of the bowel disease were established endoscopically.Each patient underwent pulmonary function tests and high-resolution computed tomography(HRCT).Blood samples for measurement of C-reactive protein(CRP),erythrocyte sedimentation rate(ESR),angiotensin converting enzyme and total IgE were delivered by the patients.RESULTS:Ten(25.6%)patients had respiratory symptoms.A pulmonary function abnormality was present in 22 of 39 patients.Among all patients,the most prevalent abnormalities in lung functions were a decrease in forced expiratory volume in 1 s(FEV1),FEV1/forced vital capacity(FVC),forced expiratory flow(FEF)25%-75%,transfer coefficient for carbon monoxide(DLCO),DLCO/alveolar volume.Increased respiratory symptoms score was associated with high endoscopic activity index in UC patients.Endoscopic and clinical activities in UC patients were correlated with FEV1,FEV1/FVC,and FEF 25%-75%.Smoking status,duration of disease and medication were not correlated with pulmonary physiological test results,HRCT abnormalities,clinical/endoscopic disease activity,CRP,ESR or total IgE level or body mass index.CONCLUSION:It is important that respiratory manifestations are recognized and treated early in IBD.Otherwise,they can lead to destructive and irreversible changes in the airway wall. 展开更多
关键词 INFLAMMATORY BOWEL DISEASE ULCERATIVE COLITIS Crohn’s DISEASE high-resolution computed tomography Pulmonary function tests Lung diseases
下载PDF
Competitive trampolining influence trabecular bone structure,bone size,and bone strength 被引量:2
15
作者 Lauren A.Burt John D.Schipilow Steven K.Boyd 《Journal of Sport and Health Science》 SCIE 2016年第4期469-475,共7页
Background:Trampolining is a form of gymnastics that has increased in popularity over the last decade and due to its concurrence with the formative years of bone development,it may have an important impact on bone he... Background:Trampolining is a form of gymnastics that has increased in popularity over the last decade and due to its concurrence with the formative years of bone development,it may have an important impact on bone health.However,bone density,microarchitecture,and bone strength of competitive trampolinists have not been explored.Therefore,the purpose of this cross-sectional study was to investigate the relationship between trampolining participation and(1) bone density,area,and microarchitecture;and(2) estimated bone strength and the role of muscle and impact loading in young female adults.Methods:We recruited 29 female participants aged 16–29 years for this study(n=14 trampolinists;n=15 controls).Skeletal parameters were assessed using dual X-ray absorptiometry,high-resolution peripheral quantitative computed tomography(HR-pQCT),and finit element analysis(FEA).Muscle strength was measured using dynamometers.Results:Trampolinists had higher bone density at the hip and spine,greater trabecular density and thicker trabeculae at the tibia,as well as larger bones at both the tibia and radius than controls(p〈0.05).Trampolinists also had higher muscle strength than controls at the lower body with no difference between groups in the upper body.Estimates of bone strength using FEA were greater for trampolinists than controls at both the radius and tibia.Conclusion:This is the firs study to investigate bone density,area,and microarchitecture in female trampolinists using HR-p QCT.Trampolinists had greater bone density,area,microarchitecture,and estimated bone strength than controls. 展开更多
关键词 Dual X-ray absorptiometry Finite element analysis GYMNASTICS high-resolution peripheral quantitative computed tomography Muscle strength Trampolining
下载PDF
Efficient scheme of low-dose CT reconstruction using TV minimization with an adaptive stopping strategy and sparse dictionary learning for post-processing 被引量:2
16
作者 Yong DING Tuo HU 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2017年第12期2001-2008,共8页
Recently, low-dose computed tomography (CT) has become highly desirable because of the growing concern for the potential risks of excessive radiation. For low-dose CT imaging, it is a significant challenge to guaran... Recently, low-dose computed tomography (CT) has become highly desirable because of the growing concern for the potential risks of excessive radiation. For low-dose CT imaging, it is a significant challenge to guarantee image quality while reducing radiation dosage. Compared with classical filtered backprojection algorithms, compressed sensing-based iterative re- construction has achieved excellent imaging performance, but its clinical application is hindered due to its computational ineffi- ciency. To promote low-dose CT imaging, we propose a promising reconstruction scheme which combines total-variation mini- mization and sparse dictionary learning to enhance the reconstruction performance, and properly schedule them with an adaptive iteration stopping strategy to boost the reconstruction speed. Experiments conducted on a digital phantom and a physical phantom demonstrate a superior performance of our method over other methods in terms of image quality and computational efficiency, which validates its potential for low-dose CT imaging. 展开更多
关键词 low-dose computed tomography (CT) CT imaging Total variation Sparse dictionary learning
原文传递
Tuberous sclerosis complex-lymphangioleiomyomatosis involving several visceral organs:A case report 被引量:1
17
作者 Hong-Bin Chen Xiao-Hong Xu +5 位作者 Cai-Gui Yu Meng-Ting Wan Chuang-Li Feng Zhi-Yu Zhao Dan-E Mei Jin-Ling Chen 《World Journal of Clinical Cases》 SCIE 2021年第24期7085-7091,共7页
BACKGROUND Lymphangioleiomyomatosis(LAM)is a rare cystic lung disease characterized by the proliferation,metastasis,and infiltration of smooth muscle cells in the lung and other tissues,which can be associated with tu... BACKGROUND Lymphangioleiomyomatosis(LAM)is a rare cystic lung disease characterized by the proliferation,metastasis,and infiltration of smooth muscle cells in the lung and other tissues,which can be associated with tuberous sclerosis complex(TSC).The disorder of TSC has a variable expression,and there is great phenotypic variability.CASE SUMMARY A 32-year-old Chinese woman with a history of multiple renal angioleiomyolipoma presented with a productive cough persisting for over 2 wk.Highresolution chest computed tomography revealed interstitial changes,multiple pulmonary bullae,bilateral pulmonary nodules,and multiple fat density areas of the inferior mediastinum.Conventional and contrast ultrasonography revealed multiple high echogenic masses of the liver,kidneys,retroperitoneum,and inferior mediastinum.These masses were diagnosed as angiomyolipomas.Pathology through thoracoscopic lung biopsy confirmed LAM.Furthermore,high-throughput genome sequencing of peripheral blood DNA confirmed the presence of a heterozygous mutation,c.1831C>T(p.Arg611Trp),of the TSC2 gene.The patient was diagnosed with TSC-LAM.CONCLUSION We highlight a rare case of TSC-LAM and the first report of a mediastinum lymphangioleiomyoma associated with TSC-LAM. 展开更多
关键词 Tuberous sclerosis complex LYMPHANGIOLEIOMYOMATOSIS Angioleiomyolipoma high-resolution chest computed tomography Contrast ultrasonography Case report
下载PDF
Pre-filter that incorporates the noise model
18
作者 Gengsheng L.Zeng 《Visual Computing for Industry,Biomedicine,and Art》 2020年第1期130-136,共7页
A linear denoising filter is usually of lowpass type,and the main parameter in a lowpass filter is the cutoff frequency.The lowpass filters are normally shift invariant and can be implemented as convolution in the spa... A linear denoising filter is usually of lowpass type,and the main parameter in a lowpass filter is the cutoff frequency.The lowpass filters are normally shift invariant and can be implemented as convolution in the spatial domain or as multiplication in the Fourier domain.This paper presents a linear filter that is not characterized by its cutoff frequency but is characterized by the noise model.An example of such a linear filter is presented for lowdose X-ray computed tomography(CT). 展开更多
关键词 low-dose computed tomography DENOISING Linear filter Nonstationary filter
下载PDF
Rare imaging findings of hypersensitivity pneumonitis:A case report
19
作者 Hong-Juan Wang Xiao-Jun Chen +2 位作者 Lin-Xia Fan Qiao-Ling Qi Qi-Zhang Chen 《World Journal of Clinical Cases》 SCIE 2020年第20期5057-5061,共5页
BACKGROUND Hypersensitivity pneumonitis(HP)is an immune-mediated syndrome caused by allergen inhalation.High-resolution computed tomography(HRCT)of HP may show diffuse ground-glass opacity,centrilobular ground-glass n... BACKGROUND Hypersensitivity pneumonitis(HP)is an immune-mediated syndrome caused by allergen inhalation.High-resolution computed tomography(HRCT)of HP may show diffuse ground-glass opacity,centrilobular ground-glass nodules,areas of air-trapping,thin-walled cysts,or fibrotic changes.CASE SUMMARY A 47-year-old male patient went to the hospital complaining of cough and gradual aggravation of shortness of breath.HRCT of the lung showed that multiple nodules and ground-glass high-density shadows were present in both lungs.In addition,circular high-density shadows of various sizes were widely distributed in both lungs with relatively normal lung markings inside them.But other tests did not have a positive finding that can clarify the cause.Therefore,the patient underwent a lung biopsy.The pathological results showed that the lesions tended to be HP.After 4 mo of follow-up,the lesions in the patient's lungs were absorbed spontaneously,and the symptoms of cough and shortness of breath have disappeared.The review results suggested that the patient's disease was self-healing,which was consistent with the characteristics of HP.CONCLUSION For some patients with HP,abnormal HRCT findings,such as the lesions in the lungs,can be absorbed on their own,which is an important clue in the diagnosis of the disease.Early diagnosis by lung biopsy is necessary when antigen exposure is unknown. 展开更多
关键词 Hypersensitivity pneumonitis high-resolution computed tomography SELF-HEALING Circular high-density images Case report
下载PDF
Theranostics with radiation-induced ultrasound emission(TRUE)
20
作者 Elijah Robertson Liangzhong Xiang 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2018年第3期1-7,共7页
Two novel ultrasound imaging techniques with imaging contrast mechanisms are in the works:X-ray-induced acoustic computed tomography(XACT),and nanoscale photoacoustic tomogra-phy(nPAT).XACT has incredible potential in... Two novel ultrasound imaging techniques with imaging contrast mechanisms are in the works:X-ray-induced acoustic computed tomography(XACT),and nanoscale photoacoustic tomogra-phy(nPAT).XACT has incredible potential in:(1)biomedical imaging,through which a 3D image can be generated using only a single X-ray projection,and(2)radiation dosimetry.nPATas a new alternative of super-resolution microscopy can break through the optical difraction limitand is capable of exploring sub-celular structures without reliance on fuorescence labeling.We expect these new imaging techniques to find widespread applications in both pre-clinical andclinical biomedical research. 展开更多
关键词 X-ray-induced_acoustic computed tomography(XACT) low-dose CT three-dimensional(3D)volumetric imaging nanoscale photoacoustic tomography label-fre super-resolution
下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部