This paper presents the first of a series of studies on the seismic design of high-rise towers for cablestayed bridges under strong earthquakes.One practical cable-stayed bridge with a 730 m long main span and two hig...This paper presents the first of a series of studies on the seismic design of high-rise towers for cablestayed bridges under strong earthquakes.One practical cable-stayed bridge with a 730 m long main span and two high-rise towers over 200 m in height was selected for this study.The preliminary results show that compared with piers,the tower is more vulnerable to pulse-like earthquakes,and it may develop plasticity at certain locations.In addition,viscous dampers may not have the same effect during pulse-like earthquakes as they do under site-specific earthquakes.Hence,reoptimization of damper parameters or reconsideration of other energy dissipation devices will be needed if strong earthquakes are likely to occur.展开更多
Let p be a prime. For any finite p-group G, the deep transfers T H,G ' : H / H ' → G ' / G " from the maximal subgroups H of index (G:H) = p in G to the derived subgroup G ' are introduced as an ...Let p be a prime. For any finite p-group G, the deep transfers T H,G ' : H / H ' → G ' / G " from the maximal subgroups H of index (G:H) = p in G to the derived subgroup G ' are introduced as an innovative tool for identifying G uniquely by means of the family of kernels ùd(G) =(ker(T H,G ')) (G: H) = p. For all finite 3-groups G of coclass cc(G) = 1, the family ùd(G) is determined explicitly. The results are applied to the Galois groups G =Gal(F3 (∞)/ F) of the Hilbert 3-class towers of all real quadratic fields F = Q(√d) with fundamental discriminants d > 1, 3-class group Cl3(F) □ C3 × C3, and total 3-principalization in each of their four unramified cyclic cubic extensions E/F. A systematic statistical evaluation is given for the complete range 1 d 7, and a few exceptional cases are pointed out for 1 d 8.展开更多
Background:Disease-modifying therapy is the standard treatment for patients with multiple sclerosis (MS)in remission.The primary objective of the current analysis was to assess the efficacy and safety of two terifluno...Background:Disease-modifying therapy is the standard treatment for patients with multiple sclerosis (MS)in remission.The primary objective of the current analysis was to assess the efficacy and safety of two teriflunomide doses (7mg and 14mg)in the subgroup of Chinese patients with relapsing MS included in the TOWER study. Methods:TOWER was a multicenter,multinational,randomized, double-blind,parallel-group (three groups),placebo-controlled study.This subgroup analysis includes 148 Chinese patients randomized to receive either teriflunomide 7mg (n =51), teriflunomide 14mg (n=43),or placebo (n=54). Results:Of the 148patients in the intent-to-treat population, adjusted annualized-relapse rates were 0.63(95% confidence interval [CI]:0.44,0.92)in the placebo group,0.48(95%CI:0.33, 0.70)in the teriflunomide 7mg group,and 0.18(95%CI:0.09,0.36)in the terifltmomide 14mg group;this corresponded to a significant relative risk reduction in the teriflunomide 14mg group versus placebo (-71.2%,P =0.0012).Terifiunomide 14mg also tended to reduce 12-week confirmed disability worsening by 68.1% compared with placebo (hazard ratio:0.319,P =0.1194).There were no differences across all treatment groups in the proportion of patients with treatment-emergent adverse events (TEAEs;72.2% in the placebo group,74.5%in the teriflunomide 7mg group,and 69.8% in the teriflunomide 14mg group);corresponding proportions for serious adverse events were 11.1%,3.9%,and 11.6%,respectively.The most frequently reported TEAEs with teriflunomide versus placebo were neutropenia,increased alanine aminotransferase,and hair thinning. Conclusions:Teriflunomide was as effective and safe in the Chinese subpopulation as it was in the overall population of patients in the TOWER trial.Teriflunomide has the potential to meet unmet medical needs for MS patients in China.展开更多
Solar multiple (SM) and thermal storage capacity are two key design parameters for revealing the performance of direct steam generation (DSG) solar power tower plant. In the case of settled land area, SM and therm...Solar multiple (SM) and thermal storage capacity are two key design parameters for revealing the performance of direct steam generation (DSG) solar power tower plant. In the case of settled land area, SM and thermal storage capacity can be optimized to obtain the minimum levelized cost of electricity (LCOE) by adjusting the power generation output. Taking the dual-receiver DSG solar power tower plant with a given size of solar field equivalent electricity of 100 MWe in Sevilla as a reference case, the minimum LCOE is 21.77 /kWhe with an SM of 1.7 and a thermal storage capacity of 3 h. Besides Sevilla, two other sites are also introduced to discuss the influence of annual DNI. When compared with the case of Sevilla, the minimum LCOE and optimal SM of the San Jose site change just slightly, while the minimum LCOE of the Bishop site decreases by 32.8% and the optimal SM is reduced to 1.3. The influence of the size of solar field equivalent electricity is studied as well. The minimum LCOE decreases with the size of solar field, while the optimal SM and thermal storage capacity still remain unchanged. In addition, the sensitivity of different investment in sub-system is investigated. In terms ofoptimal SM and thermal storage capacity, they can decrease with the cost of thermal storage system but increase with the cost of power generation unit.展开更多
基金This research is supported by the National Science Foundation of China(Grant No.51008225)by the Scientific Research Foundation for the Returned Overseas Chinese Scholars of the State Education Ministry in China.
文摘This paper presents the first of a series of studies on the seismic design of high-rise towers for cablestayed bridges under strong earthquakes.One practical cable-stayed bridge with a 730 m long main span and two high-rise towers over 200 m in height was selected for this study.The preliminary results show that compared with piers,the tower is more vulnerable to pulse-like earthquakes,and it may develop plasticity at certain locations.In addition,viscous dampers may not have the same effect during pulse-like earthquakes as they do under site-specific earthquakes.Hence,reoptimization of damper parameters or reconsideration of other energy dissipation devices will be needed if strong earthquakes are likely to occur.
文摘Let p be a prime. For any finite p-group G, the deep transfers T H,G ' : H / H ' → G ' / G " from the maximal subgroups H of index (G:H) = p in G to the derived subgroup G ' are introduced as an innovative tool for identifying G uniquely by means of the family of kernels ùd(G) =(ker(T H,G ')) (G: H) = p. For all finite 3-groups G of coclass cc(G) = 1, the family ùd(G) is determined explicitly. The results are applied to the Galois groups G =Gal(F3 (∞)/ F) of the Hilbert 3-class towers of all real quadratic fields F = Q(√d) with fundamental discriminants d > 1, 3-class group Cl3(F) □ C3 × C3, and total 3-principalization in each of their four unramified cyclic cubic extensions E/F. A systematic statistical evaluation is given for the complete range 1 d 7, and a few exceptional cases are pointed out for 1 d 8.
文摘Background:Disease-modifying therapy is the standard treatment for patients with multiple sclerosis (MS)in remission.The primary objective of the current analysis was to assess the efficacy and safety of two teriflunomide doses (7mg and 14mg)in the subgroup of Chinese patients with relapsing MS included in the TOWER study. Methods:TOWER was a multicenter,multinational,randomized, double-blind,parallel-group (three groups),placebo-controlled study.This subgroup analysis includes 148 Chinese patients randomized to receive either teriflunomide 7mg (n =51), teriflunomide 14mg (n=43),or placebo (n=54). Results:Of the 148patients in the intent-to-treat population, adjusted annualized-relapse rates were 0.63(95% confidence interval [CI]:0.44,0.92)in the placebo group,0.48(95%CI:0.33, 0.70)in the teriflunomide 7mg group,and 0.18(95%CI:0.09,0.36)in the terifltmomide 14mg group;this corresponded to a significant relative risk reduction in the teriflunomide 14mg group versus placebo (-71.2%,P =0.0012).Terifiunomide 14mg also tended to reduce 12-week confirmed disability worsening by 68.1% compared with placebo (hazard ratio:0.319,P =0.1194).There were no differences across all treatment groups in the proportion of patients with treatment-emergent adverse events (TEAEs;72.2% in the placebo group,74.5%in the teriflunomide 7mg group,and 69.8% in the teriflunomide 14mg group);corresponding proportions for serious adverse events were 11.1%,3.9%,and 11.6%,respectively.The most frequently reported TEAEs with teriflunomide versus placebo were neutropenia,increased alanine aminotransferase,and hair thinning. Conclusions:Teriflunomide was as effective and safe in the Chinese subpopulation as it was in the overall population of patients in the TOWER trial.Teriflunomide has the potential to meet unmet medical needs for MS patients in China.
基金This research was supported by the National Natural Science Foundation of China (Grant No. 51676069), the 111 Project (1312034), and the Fundamental Research Funds for the Central Universities (Grant No. 2016XS30).
文摘Solar multiple (SM) and thermal storage capacity are two key design parameters for revealing the performance of direct steam generation (DSG) solar power tower plant. In the case of settled land area, SM and thermal storage capacity can be optimized to obtain the minimum levelized cost of electricity (LCOE) by adjusting the power generation output. Taking the dual-receiver DSG solar power tower plant with a given size of solar field equivalent electricity of 100 MWe in Sevilla as a reference case, the minimum LCOE is 21.77 /kWhe with an SM of 1.7 and a thermal storage capacity of 3 h. Besides Sevilla, two other sites are also introduced to discuss the influence of annual DNI. When compared with the case of Sevilla, the minimum LCOE and optimal SM of the San Jose site change just slightly, while the minimum LCOE of the Bishop site decreases by 32.8% and the optimal SM is reduced to 1.3. The influence of the size of solar field equivalent electricity is studied as well. The minimum LCOE decreases with the size of solar field, while the optimal SM and thermal storage capacity still remain unchanged. In addition, the sensitivity of different investment in sub-system is investigated. In terms ofoptimal SM and thermal storage capacity, they can decrease with the cost of thermal storage system but increase with the cost of power generation unit.