期刊文献+
共找到3,315篇文章
< 1 2 166 >
每页显示 20 50 100
Value of multiple models of diffusion-weighted imaging to predict hepatic lymph node metastases in colorectal liver metastases patients 被引量:1
1
作者 Hai-Bin Zhu Bo Zhao +3 位作者 Xiao-Ting Li Xiao-Yan Zhang Qian Yao Ying-Shi Sun 《World Journal of Gastroenterology》 SCIE CAS 2024年第4期308-317,共10页
BACKGROUND About 10%-31% of colorectal liver metastases(CRLM)patients would concomitantly show hepatic lymph node metastases(LNM),which was considered as sign of poor biological behavior and a relative contraindicatio... BACKGROUND About 10%-31% of colorectal liver metastases(CRLM)patients would concomitantly show hepatic lymph node metastases(LNM),which was considered as sign of poor biological behavior and a relative contraindication for liver resection.Up to now,there’s still lack of reliable preoperative methods to assess the status of hepatic lymph nodes in patients with CRLM,except for pathology examination of lymph node after resection.AIM To compare the ability of mono-exponential,bi-exponential,and stretchedexponential diffusion-weighted imaging(DWI)models in distinguishing between benign and malignant hepatic lymph nodes in patients with CRLM who received neoadjuvant chemotherapy prior to surgery.METHODS In this retrospective study,97 CRLM patients with pathologically confirmed hepatic lymph node status underwent magnetic resonance imaging,including DWI with ten b values before and after chemotherapy.Various parameters,such as the apparent diffusion coefficient from the mono-exponential model,and the true diffusion coefficient,the pseudo-diffusion coefficient,and the perfusion fraction derived from the intravoxel incoherent motion model,along with distributed diffusion coefficient(DDC)andαfrom the stretched-exponential model(SEM),were measured.The parameters before and after chemotherapy were compared between positive and negative hepatic lymph node groups.A nomogram was constructed to predict the hepatic lymph node status.The reliability and agreement of the measurements were assessed using the coefficient of variation and intraclass correlation coefficient.RESULTS Multivariate analysis revealed that the pre-treatment DDC value and the short diameter of the largest lymph node after treatment were independent predictors of metastatic hepatic lymph nodes.A nomogram combining these two factors demonstrated excellent performance in distinguishing between benign and malignant lymph nodes in CRLM patients,with an area under the curve of 0.873.Furthermore,parameters from SEM showed substantial repeatability.CONCLUSION The developed nomogram,incorporating the pre-treatment DDC and the short axis of the largest lymph node,can be used to predict the presence of hepatic LNM in CRLM patients undergoing chemotherapy before surgery.This nomogram was proven to be more valuable,exhibiting superior diagnostic performance compared to quantitative parameters derived from multiple b values of DWI.The nomogram can serve as a preoperative assessment tool for determining the status of hepatic lymph nodes and aiding in the decision-making process for surgical treatment in CRLM patients. 展开更多
关键词 Colorectal cancer Individualized treatment Diffusion magnetic resonance imaging Intravoxel incoherent motion LIVER
下载PDF
Secure Transmission of Compressed Medical Image Sequences on Communication Networks Using Motion Vector Watermarking
2
作者 Rafi Ullah Mohd Hilmi bin Hasan +1 位作者 Sultan Daud Khan Mussadiq Abdul Rahim 《Computers, Materials & Continua》 SCIE EI 2024年第3期3283-3301,共19页
Medical imaging plays a key role within modern hospital management systems for diagnostic purposes.Compression methodologies are extensively employed to mitigate storage demands and enhance transmission speed,all whil... Medical imaging plays a key role within modern hospital management systems for diagnostic purposes.Compression methodologies are extensively employed to mitigate storage demands and enhance transmission speed,all while upholding image quality.Moreover,an increasing number of hospitals are embracing cloud computing for patient data storage,necessitating meticulous scrutiny of server security and privacy protocols.Nevertheless,considering the widespread availability of multimedia tools,the preservation of digital data integrity surpasses the significance of compression alone.In response to this concern,we propose a secure storage and transmission solution for compressed medical image sequences,such as ultrasound images,utilizing a motion vector watermarking scheme.The watermark is generated employing an error-correcting code known as Bose-Chaudhuri-Hocquenghem(BCH)and is subsequently embedded into the compressed sequence via block-based motion vectors.In the process of watermark embedding,motion vectors are selected based on their magnitude and phase angle.When embedding watermarks,no specific spatial area,such as a region of interest(ROI),is used in the images.The embedding of watermark bits is dependent on motion vectors.Although reversible watermarking allows the restoration of the original image sequences,we use the irreversible watermarking method.The reason for this is that the use of reversible watermarks may impede the claims of ownership and legal rights.The restoration of original data or images may call into question ownership or other legal claims.The peak signal-to-noise ratio(PSNR)and structural similarity index(SSIM)serve as metrics for evaluating the watermarked image quality.Across all images,the PSNR value exceeds 46 dB,and the SSIM value exceeds 0.92.Experimental results substantiate the efficacy of the proposed technique in preserving data integrity. 展开更多
关键词 Block matching algorithm(BMA) compression full-search algorithm motion vectors ultrasound image sequence WATERMARKING
下载PDF
Impact of resonant magnetic perturbation on blob motion and structure using a gas puff imaging diagnostic on the HL-2A tokamak
3
作者 袁金榜 许敏 +6 位作者 余羿 袁博达 聂林 季小全 孙腾飞 王傲 李继全 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第9期34-41,共8页
The impact of resonant magnetic perturbation(RMP)on blob motion and structure in the SOL of the HL-2A tokamak is studied using a gas puff imaging diagnostic.Ellipse fitting is applied to study the structure and motion... The impact of resonant magnetic perturbation(RMP)on blob motion and structure in the SOL of the HL-2A tokamak is studied using a gas puff imaging diagnostic.Ellipse fitting is applied to study the structure and motion of blobs quantitatively.The radial locations,amplitudes and scale sizes of blobs are obtained based on the fitted ellipse.Furthermore,based on the measurement of blob location,the radial and poloidal velocities of blobs are calculated.With the application of RMP,the edge poloidal shear flow is significantly weakened and the wave number spectrum changes from quasisymmetric to significantly up-down asymmetric.The application of RMP also causes the detected blob location to be much further into the far scrape-off layer(SOL)and increases the blob amplitude.Blob poloidal velocity in the SOL is slowed.Larger-size and longer-lifetime blobs are observed with RMP.With the application of RMP,stronger-amplitude and larger-size blobs are detected in the far SOL and they may cause a more serious erosion problem to the first wall. 展开更多
关键词 resonance magnetic perturbations blob structure blob motion gas puff imaging
下载PDF
Particle velocity measurement of binary mixtures in the riser of a circulating fluidized bed by the combined use of electrostatic sensing and high-speed imaging
4
作者 Wen-Biao Zhang Tian-Yu Wang +2 位作者 Yao-Yao Liu Wen-Bo Zhan Chi-Hwa Wang 《Petroleum Science》 SCIE CAS CSCD 2020年第4期1159-1170,共12页
The flow dynamics of binary particle mixtures in the fluidized bed needs to be monitored in order to optimize the related industrial processes.In this paper,electrostatic sensing and high-speed imaging are applied to ... The flow dynamics of binary particle mixtures in the fluidized bed needs to be monitored in order to optimize the related industrial processes.In this paper,electrostatic sensing and high-speed imaging are applied to measure the velocities of polyethylene and sand particles in the binary particle mixtures in fluidization.Experimental studies were conducted on a lab-scale cold circulating fluidized bed.Correlation function between electrostatic signals from upstream and downstream electrodes placed along the riser shows two peaks that represent transit times for the two types of particles.To verify the above results,high-speed imaging was adopted to capture the flow images of particle mixtures.Particle Image Velocimetry and Particle Tracking Velocimetry algorithms were utilized to process the resulted images in order to measure the velocities of polyethylene and sand particles.The reasons for two-peak correlation functions are illustrated based on the frequency spectrums of the mono-solid-phase electrostatic signals and the velocity difference between polyethylene and sand particles.Finally,comparisons on the velocities obtained from electrostatic sensing and high-speed imaging demonstrate the electrostatic sensor can roughly estimate the particle velocity of binary particle mixtures in the near wall region of the circulating fluidized bed. 展开更多
关键词 Binary mixtures Fluidized bed Electrostatic sensor high-speed imaging
下载PDF
Intravoxel incoherent motion diffusion-weighted magnetic resonance imaging for predicting histological grade of hepatocellular carcinoma:Comparison with conventional diffusion-weighted imaging 被引量:36
5
作者 Shao-Cheng Zhu Yue-Hua Liu +4 位作者 Yi Wei Lin-Lin Li She-Wei Dou Ting-Yi Sun Da-Peng Shi 《World Journal of Gastroenterology》 SCIE CAS 2018年第8期929-940,共12页
AIM To compare intravoxel incoherent motion(IVIM)-derived parameters with conventional diffusion-weighted imaging(DWI) parameters in predicting the histological grade of hepatocellular carcinoma(h CC) and to evaluate ... AIM To compare intravoxel incoherent motion(IVIM)-derived parameters with conventional diffusion-weighted imaging(DWI) parameters in predicting the histological grade of hepatocellular carcinoma(h CC) and to evaluate the correlation between the parameters and the histological grades.METHODS A retrospective study was performed. Sixty-two patients with surgically confirmed h CCs underwent diffusion-weighted magnetic resonance imaging with twelve b values(10-1200 s/mm^2). The apparent diffusion coefficient(ADC), pure diffusion coefficient(D), pseudo-diffusion coefficient(D*), and perfusion fraction(f) were calculated by two radiologists. The IVIM and conventional DWI parameters were compared among the different grades by using analysis of variance(ANOVA) and the Kruskal-Wallis test. Receiver operating characteristic(ROC) analysis was performed to evaluate the diagnostic efficiency of distinguishing between low-grade(grade 1, G1) and high-grade(grades 2 and 3, G2 and G3) hC C. The correlation between the parameters and the histological grades was assessed by using the Spearman correlation test. Bland-Altman analysis was used to evaluate the reproducibility of the two radiologists' measurements.RESULTS The differences in the ADC and D values among the groups with G1, G2, and G3 histological grades of HCCs were statistically significant(P < 0.001). The D* and f values had no significant differences among the different histological grades of h CC(P > 0.05). The ROC analyses demonstrated that the D and ADC values had better diagnostic performance in differentiating the low-grade h CC from the high-grade h CC, with areas under the curve(AUCs) of 0.909 and 0.843, respectively, measured by radiologist 1 and of 0.911 and 0.852, respectively, measured by radiologist 2. The following significant correlations were obtained between the ADC, D, and D~* values and the histological grades: r =-0.619(P < 0.001), r =-0.628(P < 0.001), and r =-0.299(P = 0.018), respectively, as measured by radiologist 1; r =-0.622(P < 0.001), r =-0.633(P < 0.001), and r =-0.303(P = 0.017), respectively, as measured by radiologist 2. The intra-class correlation coefficient(ICC) values between the two observers were 0.996 for ADC, 0.997 for D, 0.996 for D*, and 0.992 for f values, which indicated excellent interobserver agreement in the measurements between the two observers.CONCLUSION The IVIM-derived D and ADC values show better diagnostic performance in differentiating high-grade hC C from low-grade hC C, and there is a moderate to good correlation between the ADC and D values and the histological grades. 展开更多
关键词 Intravoxel INCOHERENT motion Diffusionweighted imaging HEPATOCELLULAR CARCINOMA PATHOLOGICAL DIFFERENTIATION GRADE
下载PDF
Liver intravoxel incoherent motion diffusion-weighted imaging for the assessment of hepatic steatosis and fibrosis in children 被引量:11
6
作者 Hyun Joo Shin Haesung Yoon +4 位作者 Myung-Joon Kim Seok Joo Han Hong Koh Seung Kim Mi-Jung Lee 《World Journal of Gastroenterology》 SCIE CAS 2018年第27期3013-3020,共8页
AIM To evaluate the correlation between intravoxel incoherent motion(IVIM) diffusion-weighted imaging(DWI) parameters and the degree of hepatic steatosis and fibrosis in children.METHODS This retrospective study was a... AIM To evaluate the correlation between intravoxel incoherent motion(IVIM) diffusion-weighted imaging(DWI) parameters and the degree of hepatic steatosis and fibrosis in children.METHODS This retrospective study was approved by the institutional review board. The children(≤ 18 years) who underwent liver IVIM DWI with 8 b-values under the suspicion of hepatic steatosis or fibrosis from February 2013 to November 2016 were included. Subjects were divided into normal, fatty liver(FAT), and fibrotic liver(FIB) groups. The slow diffusion coefficient(D), fast diffusion coefficient(D*), perfusion fraction(f), and apparent diffusion coefficient(ADC) were measured. MR proton density fat fraction(PDFF), MR elastography(MRE), and IVIM values were compared.RESULTS A total of 123 children(median age of 12 years old, range: 6-18 years) were included, with 8 in the normal group, 93 in the FAT group, and 22 in the FIB group. The D* values were lower in the FIB group compared with those of the normal(P = 0.015) and FAT(P = 0.003) groups. The f values were lower in the FIB group compared with the FAT group(P = 0.001). In multivariate analyses, PDFF value was positively correlated with f value(β = 3.194, P < 0.001), and MRE value was negatively correlated with D* value(β =-7.031, P = 0.032). The D and ADC values were not influenced by PDFF or MRE value.CONCLUSION In liver IVIM DWI with multiple b-values in children, there was a positive correlation between hepatic fat and blood volume, and a negative correlation between hepatic stiffness and endovascular blood flow velocity, while diffusion-related parameters were not affected. 展开更多
关键词 Intravoxel INCOHERENT motion Diffusionweighted imaging FIBROSIS FATTY LIVER PEDIATRICS
下载PDF
Motion stability of high-speed maglev systems in consideration of aerodynamic effects: a study of a single magnetic suspension system 被引量:8
7
作者 Han Wu Xiao-Hui Zeng Yang Yu 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2017年第6期1084-1094,共11页
In this study, the intrinsic mechanism of aerodynamic effects on the motion stability of a high-speed maglev system was investigated. The concept of a critical speed for maglev vehicles considering the aerodynamic eff... In this study, the intrinsic mechanism of aerodynamic effects on the motion stability of a high-speed maglev system was investigated. The concept of a critical speed for maglev vehicles considering the aerodynamic effect is proposed. The study was carried out based on a single magnetic suspension system, which is convenient for proposing relevant concepts and obtaining explicit expressions. This study shows that the motion stability of the suspension system is closely related to the vehicle speed when aerodynamic effects are considered. With increases of the vehicle speed, the stability behavior of the system changes. At a certain vehicle speed,the stability of the system reaches a critical state, followed by instability. The speed corresponding to the critical state is the critical speed. Analysis reveals that when the system reaches the critical state, it takes two forms, with two critical speeds, and thus two expressions for the critical speed are obtained. The conditions of the existence of the critical speed were determined, and the effects of the control parameters and the lift coefficient on the critical speed were analyzed by numerical analysis. The results show that the first critical speed appears when the aerodynamic force is upward,and the second critical speed appears when the aerodynamic force is downward. Moreover, both critical speeds decrease with the increase of the lift coefficient. 展开更多
关键词 high-speed maglev system Critical speed Aerodynamic effect motion stability
下载PDF
Near-fault directivity pulse-like ground motion effect on high-speed railway bridge 被引量:8
8
作者 陈令坤 张楠 +3 位作者 蒋丽忠 曾志平 陈格威 国巍 《Journal of Central South University》 SCIE EI CAS 2014年第6期2425-2436,共12页
The vehicle-track-bridge(VTB)element was used to investigate how a high-speed railway bridge reacted when it was subjected to near-fault directivity pulse-like ground motions.Based on the PEER NAG Strong Ground Motion... The vehicle-track-bridge(VTB)element was used to investigate how a high-speed railway bridge reacted when it was subjected to near-fault directivity pulse-like ground motions.Based on the PEER NAG Strong Ground Motion Database,the spatial analysis model of a vehicle-bridge system was developed,the VTB element was derived to simulate the interaction of train and bridge,and the elasto-plastic seismic responses of the bridge were calculated.The calculation results show that girder and pier top displacement,and bending moment of the pier base increase subjected to near-fault directivity pulse-like ground motion compared to far-field earthquakes,and the greater deformation responses in near-fault shaking are associated with fewer reversed cycles of loading.The hysteretic characteristics of the pier subjected to a near-fault directivity pulse-like earthquake should be explicitly expressed as the bending moment-rotation relationship of the pier base,which is characterized by the centrally strengthened hysteretic cycles at some point of the loading time-history curve.The results show that there is an amplification of the vertical deflection in the girder's mid-span owing to the high vertical ground motion.In light of these findings,the effect of the vertical ground motion should be used to adjust the unconservative amplification constant 2/3 of the vertical-to-horizontal peak ground motion ratio in the seismic design of bridge. 展开更多
关键词 ELEMENT near-fault ground motion directivity pulse high-speed railway bridge earthquake response
下载PDF
Dynamic Analysis of High-Speed Boat Motion Simulator by a Novel 3-DoF Parallel Mechanism with Prismatic Actuators Based on Seakeeping Trial 被引量:3
9
作者 Ali Pirouzfar Javad Enferadi Masoud Dehghan 《Journal of Marine Science and Application》 CSCD 2018年第2期178-191,共14页
In this study,we focused on a novel parallel mechanism for utilizing the motion simulator of a high-speed boat(HSB).First,we expressed the real behavior of the HSB based on a seakeeping trial.For this purpose,we recor... In this study,we focused on a novel parallel mechanism for utilizing the motion simulator of a high-speed boat(HSB).First,we expressed the real behavior of the HSB based on a seakeeping trial.For this purpose,we recorded the motion parameters of the HSB by gyroscope and accelerometer sensors,while using a special data acquisition technique.Additionally,a Chebychev highpass filter was applied as a noise filter to the accelerometer sensor.Then,a novel 3 degrees of freedom(DoF)parallel mechanism(1T2R)with prismatic actuators is proposed and analyses were performed on its inverse kinematics,velocity,and acceleration.Finally,the inverse dynamic analysis is presented by the principle of virtual work,and the validation of the analytical equations was compared by the ADAMS simulation software package.Additionally,according to the recorded experimental data of the HSB,the feasibility of the proposed novel parallel mechanism motion simulator of the HSB,as well as the necessity of using of the washout filters,was explored. 展开更多
关键词 motion simulators Parallel mechanism high-speed BOAT SEAKEEPING TRIAL INVERSE dynamics Virtualwork
下载PDF
Intravoxel incoherent motion diffusion-weighted imaging for monitoring chemotherapeutic efficacy in gastric cancer 被引量:12
10
作者 Xiao-Li Song Heoung Keun Kang +5 位作者 Gwang Woo Jeong Kyu Youn Ahn Yong Yeon Jeong Yang Joon Kang Hye Jung Cho Chung Man Moon 《World Journal of Gastroenterology》 SCIE CAS 2016年第24期5520-5531,共12页
AIM: To assess intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) for monitoring early efficacy of chemotherapy in a human gastric cancer mouse model.METHODS: IVIM-DWI was performed with 12 b-values (0... AIM: To assess intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) for monitoring early efficacy of chemotherapy in a human gastric cancer mouse model.METHODS: IVIM-DWI was performed with 12 b-values (0-800 s/mm<sup>2</sup>) in 25 human gastric cancer-bearing nude mice at baseline (day 0), and then they were randomly divided into control and 1-, 3-, 5- and 7-d treatment groups (n = 5 per group). The control group underwent longitudinal MRI scans at days 1, 3, 5 and 7, and the treatment groups underwent subsequent MRI scans after a specified 5-fluorouracil/calcium folinate treatment. Together with tumor volumes (TV), the apparent diffusion coefficient (ADC) and IVIM parameters [true water molecular diffusion coefficient (D), perfusion fraction (f) and pseudo-related diffusion coefficient (D<sup>*</sup>)] were measured. The differences in those parameters from baseline to each measurement (&#x00394;TV%, &#x00394;ADC%, &#x00394;D%, &#x00394;f% and &#x00394;D<sup>*</sup>%) were calculated. After image acquisition, tumor necrosis, microvessel density (MVD) and cellular apoptosis were evaluated by hematoxylin-eosin (HE), CD31 and terminal-deoxynucleotidyl transferase mediated nick end labeling (TUNEL) staining respectively, to confirm the imaging findings. Mann-Whitney test and Spearman’s correlation coefficient analysis were performed.RESULTS: The observed relative volume increase (&#x00394;TV%) in the treatment group were significantly smaller than those in the control group at day 5 (&#x00394;TV<sub>treatment</sub>% = 19.63% &#x000b1; 3.01% and &#x00394;TV<sub>control</sub>% = 83.60% &#x000b1; 14.87%, P = 0.008) and day 7 (&#x00394;TV<sub>treatment</sub>% = 29.07% &#x000b1; 10.01% and &#x00394;TV<sub>control</sub>% = 177.06% &#x000b1; 63.00%, P = 0.008). The difference in &#x00394;TV% between the treatment and the control groups was not significant at days 1 and 3 after a short duration of treatment. Increases in ADC in the treatment group (&#x00394;ADC%<sub>treatment</sub>, median, 30.10% &#x000b1; 18.32%, 36.11% &#x000b1; 21.82%, 45.22% &#x000b1; 24.36%) were significantly higher compared with the control group (&#x00394;ADC%<sub>control</sub>, median, 4.98% &#x000b1; 3.39%, 6.26% &#x000b1; 3.08%, 9.24% &#x000b1; 6.33%) at days 3, 5 and 7 (P = 0.008, P = 0.016, P = 0.008, respectively). Increases in D in the treatment group (&#x00394;D%<sub>treatment</sub>, median 17.12% &#x000b1; 8.20%, 24.16% &#x000b1; 16.87%, 38.54% &#x000b1; 19.36%) were higher than those in the control group (&#x00394;D%<sub>control</sub>, median -0.13% &#x000b1; 4.23%, 5.89% &#x000b1; 4.56%, 5.54% &#x000b1; 4.44%) at days 1, 3, and 5 (P = 0.032, P = 0.008, P = 0.016, respectively). Relative changes in f were significantly lower in the treatment group compared with the control group at days 1, 3, 5 and 7 follow-up (median, -34.13% &#x000b1; 16.61% vs 1.68% &#x000b1; 3.40%, P = 0.016; -50.64% &#x000b1; 6.82% vs 3.01% &#x000b1; 6.50%, P = 0.008; -49.93% &#x000b1; 6.05% vs 0.97% &#x000b1; 4.38%, P = 0.008, and -46.22% &#x000b1; 7.75% vs 8.14% &#x000b1; 6.75%, P = 0.008, respectively). D* in the treatment group decreased significantly compared to those in the control group at all time points (median, -32.10% &#x000b1; 12.22% vs 1.85% &#x000b1; 5.54%, P = 0.008; -44.14% &#x000b1; 14.83% vs 2.29% &#x000b1; 10.38%, P = 0.008; -59.06% &#x000b1; 19.10% vs 3.86% &#x000b1; 5.10%, P = 0.008 and -47.20% &#x000b1; 20.48% vs 7.13% &#x000b1; 9.88%, P = 0.016, respectively). Furthermore, histopathologic findings showed positive correlations with ADC and D and tumor necrosis (r<sub>s</sub> = 0.720, P &#x0003c; 0.001; r<sub>s</sub> = 0.522, P = 0.007, respectively). The cellular apoptosis of the tumor also showed positive correlations with ADC and D (r<sub>s</sub> = 0.626, P = 0.001; r<sub>s</sub> = 0.542, P = 0.005, respectively). Perfusion-related parameters (f and D<sup>*</sup>) were positively correlated to MVD (r<sub>s</sub> = 0.618, P = 0.001; r<sub>s</sub> = 0.538, P = 0.006, respectively), and negatively correlated to cellular apoptosis of the tumor (r<sub>s</sub> = -0.550, P = 0.004; r<sub>s</sub> = -0.692, P &#x0003c; 0.001, respectively).CONCLUSION: IVIM-DWI is potentially useful for predicting the early efficacy of chemotherapy in a human gastric cancer mouse model. 展开更多
关键词 Gastric cancer Microvessel density Nude mouse model Intravoxel incoherent motion diffusion-weighted imaging Terminal-deoxynucleoitidyl transferase mediated nick end labeling
下载PDF
ACCURATE DETECTION OF HIGH-SPEED MULTI-TARGET VIDEO SEQUENCES MOTION REGIONS BASED ON RECONSTRUCTED BACKGROUND DIFFERENCE 被引量:1
11
作者 Zhang Wentao Li Xiaofeng Li Zaiming (Inst. of Communication and Information, UEST of China, Chengdu 610054) 《Journal of Electronics(China)》 2001年第1期1-7,共7页
The paper first discusses shortcomings of classical adjacent-frame difference. Sec ondly, based on the image energy and high order statistic(HOS) theory, background reconstruction constraints are setup. Under the help... The paper first discusses shortcomings of classical adjacent-frame difference. Sec ondly, based on the image energy and high order statistic(HOS) theory, background reconstruction constraints are setup. Under the help of block-processing technology, background is reconstructed quickly. Finally, background difference is used to detect motion regions instead of adjacent frame difference. The DSP based platform tests indicate the background can be recovered losslessly in about one second, and moving regions are not influenced by moving target speeds. The algorithm has important usage both in theory and applications. 展开更多
关键词 motion DETECTION BACKGROUND reconstruction image energy HOS high-speed target Block processing
下载PDF
Intravoxel Incoherent Motion Diffusion Weighted Imaging for the Therapeutic Response of Transarterial Chemoembolization for Hepatocellular Carcinoma 被引量:3
12
作者 Juan Peng Cui Yang +9 位作者 Jing Zheng Ran Wang Yi Zhou Weicheng Wang Lin Yang Xiaoming Zhang Nandong Miao Yongjun Ren Hao Xu Xuli Min 《Journal of Cancer Therapy》 2019年第7期591-601,共11页
Background: Intravoxel incoherent motion diffusion weighted imaging (IVIM-DWI) can not only observe the diffusion of tissue water molecules but also reflect the blood perfusion information of tissue microcirculation. ... Background: Intravoxel incoherent motion diffusion weighted imaging (IVIM-DWI) can not only observe the diffusion of tissue water molecules but also reflect the blood perfusion information of tissue microcirculation. IVIM-DWI has been applied in many clinical areas. However, few studies have addressed the use of IVIM-DWI for the evaluation of transarterial chemoembolization (TACE) response in hepatocellular carcinoma (HCC) patients. Objectives: The purpose of the present study was to explore the role of IVIM-DWI for the therapeutic response of TACE for HCC. Materials and Methods: Twenty patients underwent IVIM-DWI scan on a 3.0T magnetic resonance imaging instrument 1 - 3 days before and 30 to 40 days after TACE. The values of IVIM-DWI parameters, including standard apparent diffusion coefficient (ADC), pure diffusion coefficient (Dslow), pseudo-diffusion coefficient (Dfast) and perfusion fraction (f) were measured. The values of IVIM-DWI parameters before and after TACE were compared using paired t tests. The values between responsive and non-responsive groups were compared using independent-samples t test. P 0.05 indicated statistical significance. Results: After TACE, the ADC and Dslow values in the tumors increased significantly, and the values of Dfast decreased significantly, while the values of f value did not change obviously. The ADC values in responsive group were remarkably higher than those in non-responsive group, the Dfast values in responsive group were significantly lower than those in non-responsive group, but the values of Dslow and f between the two groups were not different significantly. Conclusions: IVIM-DWI parameters can be used as potential markers for the therapeutic response of TACE for HCC. 展开更多
关键词 HEPATOCELLULAR CARCINOMA DIFFUSION-WEIGHTED imaging Intravoxel INCOHERENT motion Transarterial CHEMOEMBOLIZATION
下载PDF
Intravoxel incoherent motion magnetic resonance imaging for diagnosis of cervical cancer and evaluation of response of uterine cervical cancer to radiochemotherapy: A pilot study 被引量:1
13
作者 Yanchun Wang Shan Hu +7 位作者 Xuemei Hu Jianjun Li Yaqi Shen Xiaoyu Liu Zhi Wang Xiaoyan Meng Zhen Li Daoyu Hu 《Oncology and Translational Medicine》 CAS 2015年第4期164-170,共7页
Objective The aim of this study was to investigate the ability of intravoxel incoherent motion(IVIM) diffusion-weighted magnetic resonance imaging(MRI) to diagnose cervical cancer and to evaluate the response of uteri... Objective The aim of this study was to investigate the ability of intravoxel incoherent motion(IVIM) diffusion-weighted magnetic resonance imaging(MRI) to diagnose cervical cancer and to evaluate the response of uterine cervical cancer to radiochemotherapy(CRT).Methods This prospective study was approved by the institutional review board, and informed consent was obtained from all patients. A total of 23 patients with primary cervical cancer who were undergoing CRT and 16 age-matched healthy subjects were prospectively recruited for IVIM(b = 0–800 s/mm2) and standard pelvic MRI. Bi-exponential analysis was performed to derive f(perfusion fraction), D*(pseudo-diffusion coefficient), and D(true molecular diffusion coefficient) in cervical cancer(n = 23) and the normal cervix(n = 16). The apparent diffusion coefficient(standard ADC) was calculated. The independent-samples t-test and paired-samples t-test were used for comparisons.Results Pre-treatment cervical cancer had the lowest standard ADC(1.15 ± 0.13 × 10-3 mm2/s) and D(0.89 ± 0.10 × 10-3 mm2/s) values, and these were significantly different from the normal cervix and posttreatment cervical cancer(P = 0.00). The f(16.67 ± 5.85%) was lowest in pre-treatment cervical cancer and was significantly different from the normal cervix and post-treatment cervical cancer(p = 0.012 and 0.00, respectively). No difference was observed in D*.Conclusion IVIM is potentially promising for differentiating between the normal cervix and cervical cancer because pre-treated cervical cancer has low perfusion and diffusion IVIM characteristics. Further, the standard ADC, D, and f of cervical cancer showed a tendency to normalize after CRT; thus, IVIM may be useful for monitoring the response to CRT in cervical cancer. 展开更多
关键词 diffusion-weighted imaging magnetic resonance imaging (MRI) investigate the ability of intravoxel incoherent motion (IVIM) cervical cancer RADIOCHEMOTHERAPY
下载PDF
Bioinspired Polarized Optical Flow Enables Turbid Underwater Target Motion Estimation
14
作者 CHENG Haoyuan ZHAO Shujie +2 位作者 ZHU Jinchi YU Hao CHU Jinkui 《Journal of Ocean University of China》 SCIE CAS CSCD 2024年第4期915-923,共9页
Underwater target motion estimation is a challenge for ocean military and scientific research.In this work,we propose a method based on the combination of polarization imaging and optical flow for turbid underwater ta... Underwater target motion estimation is a challenge for ocean military and scientific research.In this work,we propose a method based on the combination of polarization imaging and optical flow for turbid underwater target detection.Polarization imaging can reduce the influence of backscattered light and obtain high-quality images underwater.The optical flow shows the motion and structural information of the target.We use polarized optical flow to obtain the optical flow field and estimate the target motion.The experimental results of different targets under varying water turbidity levels illustrate that our method is realizable and robust.The precision is verified by comparing the results with the precise displacement data and calculating two error measures.The proposed method based on polarized optical flow can obtain accurate displacement information and a good recognition effect.Moving target segmentation based on the Otsu method further proves the superiority of the polarized optical flow under turbid water.This study is valuable for target detection and motion estimation in scattering environments. 展开更多
关键词 turbid underwater motion estimation polarization imaging optical flow
下载PDF
Reproducibility study of intravoxel incoherent motion and apparent diffusion coefficient parameters in normal pancreas
15
作者 Xiang Liu Yi-Feng Wang +6 位作者 Xiao-Hui Qi Zhi-Lei Zhang Jiang-Yang Pan Xue-Li Fan Yu Du Ying-Min Zhai Qi Wang 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第7期2031-2039,共9页
BACKGROUND The consistency of pancreatic apparent diffusion coefficient(ADC)values and intravoxel incoherent motion(IVIM)parameter values across different magnetic resonance imaging(MRI)devices significantly impacts t... BACKGROUND The consistency of pancreatic apparent diffusion coefficient(ADC)values and intravoxel incoherent motion(IVIM)parameter values across different magnetic resonance imaging(MRI)devices significantly impacts the patient’s diagnosis and treatment.AIM To explore consistency in image quality,ADC values,and IVIM parameter values among different MRI devices in pancreatic examinations.METHODS This retrospective study was approved by the local ethics committee,and informed consent was obtained from all participants.In total,22 healthy volunteers(10 males and 12 females)aged 24-61 years(mean,28.9±2.3 years)underwent pancreatic diffusion-weighted imaging using 3.0T MRI equipment from three vendors.Two independent observers subjectively scored image quality and measured the pancreas’s overall ADC values and signal-to-noise ratios(SNRs).Subsequently,regions of interest(ROIs)were delineated for the IVIM parameters(true diffusion coefficient,pseudo-diffusion coefficient,and perfusion fraction)using post-processing software.These ROIs were on the head,body,and tail of the pancrease.The subjective image ratings were assessed using the kappa consistency test.Intraclass correlation coefficients(ICCs)and mixed linear models were used to evaluate each device’s quantitative parameter values.Finally,a pairwise analysis of IVIM parameter values across each device was performed using Bland-Altman plots.RESULTS The Kappa value for the subjective ratings of the different observers was 0.776(P<0.05).The ICC values for interobserver and intra-observer agreements for the quantitative parameters were 0.803[95% confidence interval(CI):0.684-0.880]and 0.883(95%CI:0.760-0.945),respectively(P<0.05).The ICCs for the SNR between different devices was comparable(P>0.05),and the ICCs for the ADC values from different devices were 0.870,0.707,and 0.808,respectively(P<0.05).Notably,only a few statistically significant inter-device agreements were observed for different IVIM parameters,and among those,the ICC values were generally low.The mixed linear model results indicated differences(P<0.05)in the f-value for the pancreas head,D-value for the pancreas body,and D-value for the pancreas tail obtained using different MRI machines.The Bland-Altman plots showed significant variability at some data points.CONCLUSION ADC values are consistent among different devices,but the IVIM parameters’repeatability is moderate.Therefore,the variability in the IVIM parameter values may be associated with using different MRI machines.Thus,caution should be exercised when using IVIM parameter values to assess the pancreas. 展开更多
关键词 Intravoxel incoherent motion PANCREAS image quality Consistency test
下载PDF
A Restricted, Adaptive Threshold Segmentation Approach for Processing High-Speed Image Sequences of the Glottis
16
作者 Mathew Blanco Xin Chen Yuling Yan 《Engineering(科研)》 2013年第10期357-362,共6页
In this paper, we propose a restricted, adaptive threshold approach for the segmentation of images of the glottis acquired from high speed video-endoscopy (HSV). The approach involves first, identifying a region of in... In this paper, we propose a restricted, adaptive threshold approach for the segmentation of images of the glottis acquired from high speed video-endoscopy (HSV). The approach involves first, identifying a region of interest (ROI) that encloses the vocal-fold motion extent for each image frame as estimated by the different image sequences. This procedure is then followed by threshold segmentation restricted within the identified ROI for each image frame of the original image sequences, or referred to as sub-image sequences. The threshold value is adapted for each sub-image frame and determined by respective minimum gray-scale value that typically corresponds to a spatial location within the glottis. The proposed approach is practical and highly efficient for segmenting a vast amount of image frames since simple threshold method is adapted. Results obtained from the segmentation of representative clinical image sequences are presented to verify the proposed method. 展开更多
关键词 Segmentation GLOTTIS VOCAL FOLD motion DIFFERENCE image Adaptive THRESHOLD
下载PDF
Application Progress of Intravoxel Incoherent Motion Diffusion Weighted Magnetic Resonance Imaging in Pancreatic Cancer
17
作者 Lili Xu Boxu Ren 《Yangtze Medicine》 2021年第1期23-32,共10页
Intravoxel incoherent motion imaging (IVIM), on the traditional diffusion weighted imaging (DWI) technology, uses the biexponential model and adopts the multi-b-value analysis to obtain the perfusion information of wa... Intravoxel incoherent motion imaging (IVIM), on the traditional diffusion weighted imaging (DWI) technology, uses the biexponential model and adopts the multi-b-value analysis to obtain the perfusion information of water molecule diffusion and microcirculation without the use of contrast agent. It is more and more used in pancreatic diseases, which is of great significance for the diagnosis and identification of pancreatic cancer. This article will review the principles of IVIM imaging and its application in pancreatic diseases, especially in pancreatic cancer diagnosis, the prediction of pathological grade of pancreatic ductal adenocarcinoma, the judgment of lymph node metastasis, and differentiation of pathological classification. 展开更多
关键词 Magnetic Resonance imaging Intravoxel Incoherent motion Diffusion Weighted imaging Pancreatic Disease
下载PDF
Impact of Field Strength and Respiratory Motion Control on Diffusion-Weighted MR Imaging of the Liver
18
作者 Johanna Berg Sven Mansson +2 位作者 Jonas Svensson Olle Ekberg Markus F.Müller 《Open Journal of Medical Imaging》 2013年第1期31-39,共9页
Purpose: To evaluate the impact of field strength and respiratory motion control on diffusion-weighted MR imaging (DWI) of the liver at 1.5 and 3 T. Material and Methods: Three DWI sequences using seven b-values from ... Purpose: To evaluate the impact of field strength and respiratory motion control on diffusion-weighted MR imaging (DWI) of the liver at 1.5 and 3 T. Material and Methods: Three DWI sequences using seven b-values from 20 - 400 s/mm2 were designed with identical parameters but with different handling of respiratory motion [respiratory triggered (RT), free breathing (FB), breath hold (BH)] on 3 T and 1.5 T. Thirteen volunteers were examined at a 3 T and six of them also at a 1.5 T magnet. DW images were analyzed quantitatively and qualitatively. Regions of interest were placed in cranial, middle and caudal parts of the right liver lobe (RLL) and ADC and SNR were calculated. Results: ADC in RLL tended to be lower at 3 T MRI. Least inter-subject ADC variability was found with RT in the middle RLL at 3 T. Highest ADCs were found caudally in the RLL. Significant differences in ADC between middle and caudal RLL were calculated in FB and RT at 3 T and FB and BH at 1.5 T, respectively. No significant difference in SNR was found between 3 T and 1.5 T. There were significantly more artifacts in the left liver lobe (LLL) compared to the RLL in all sequences and in the LLL at 3 T compared to 1.5 T. Conclusion: Our study suggests that longitudinal hepatic ADC measurements should be performed using equivalent field strength, b-values, and acquisition technique, given influence of these factors on ADC measurements. 展开更多
关键词 Magnetic Resonance imaging DIFFUSION Echo-Planar imaging 3 T LIVER Respiratory motion
下载PDF
MOVING OBJECT TRACKING IN DYNAMIC IMAGE SEQUENCE BASED ON ESTIMATION OF MOTION VECTORS OF FEATURE POINTS 被引量:2
19
作者 黎宁 周建江 张星星 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2009年第4期295-300,共6页
An improved estimation of motion vectors of feature points is proposed for tracking moving objects of dynamic image sequence. Feature points are firstly extracted by the improved minimum intensity change (MIC) algor... An improved estimation of motion vectors of feature points is proposed for tracking moving objects of dynamic image sequence. Feature points are firstly extracted by the improved minimum intensity change (MIC) algorithm. The matching points of these feature points are then determined by adaptive rood pattern searching. Based on the random sample consensus (RANSAC) method, the background motion is finally compensated by the parameters of an affine transform of the background motion. With reasonable morphological filtering, the moving objects are completely extracted from the background, and then tracked accurately. Experimental results show that the improved method is successful on the motion background compensation and offers great promise in tracking moving objects of the dynamic image sequence. 展开更多
关键词 motion compensation motion estimation feature extraction moving object tracking dynamic image sequence
下载PDF
Advanced imaging techniques in the therapeutic response of transarterial chemoembolization for hepatocellular carcinoma 被引量:12
20
作者 Ke Yang Xiao-Ming Zhang +2 位作者 Lin Yang Hao Xu Juan Peng 《World Journal of Gastroenterology》 SCIE CAS 2016年第20期4835-4847,共13页
Hepatocellular carcinoma(HCC) is one of the major causes of morbidity and mortality in patients with chronic liver disease. Transarterial chemoembolization(TACE) can significantly improve the survival rate of patients... Hepatocellular carcinoma(HCC) is one of the major causes of morbidity and mortality in patients with chronic liver disease. Transarterial chemoembolization(TACE) can significantly improve the survival rate of patients with HCC and is the first treatment choice for patients who are not suitable for surgical resections. The evaluation of the response to TACE treatment affects not only the assessment of the therapy efficacy but also the development of the next step in the treatment plan. The use of imaging to examine changes in tumor volume to assess the response of solid tumors to treatment has been controversial. In recent years, the emergence of new imaging technology has made it possible to observe the response of tumors to treatment prior to any morphological changes. In this article, the advances in studies reporting the use of computed tomography perfusion imaging, diffusionweighted magnetic resonance imaging(MRI), intravoxel incoherent motion, diffusion kurtosis imaging, magnetic resonance spectroscopy, magnetic resonance perfusionweighted imaging, blood oxygen level-dependent MRI, positron emission tomography(PET)/computed tomography and PET/MRI to assess the TACE treatment response are reviewed. 展开更多
关键词 Blood oxygen level-dependent Computed tomography perfusion imaging CHEMOEMBOLIZATION Diffusion kurtosis imaging Diffusion-weighted imaging Hepatocellular carcinoma Magnetic resonance perfusion-weighted imaging Intravoxel incoherent motion Magnetic resonance spectroscopy
下载PDF
上一页 1 2 166 下一页 到第
使用帮助 返回顶部