期刊文献+
共找到7,324篇文章
< 1 2 250 >
每页显示 20 50 100
Analysis of multiple-faults of high-voltage circuit breakers based on non-negative matrix decomposition
1
作者 Yongrong Zhou Zhaoxing Ma +1 位作者 Hao Chen Ruihua Wang 《Global Energy Interconnection》 EI CSCD 2024年第2期179-189,共11页
High-voltage circuit breakers are the core equipment in power networks,and to a certain extent,are related to the safe and reliable operation of power systems.However,their core components are prone to mechanical faul... High-voltage circuit breakers are the core equipment in power networks,and to a certain extent,are related to the safe and reliable operation of power systems.However,their core components are prone to mechanical faults.This study proposes a component separation method to detect multiple mechanical faults in circuit breakers that can achieve online real-time monitoring.First,a model and strategy are presented for obtaining mechanical voiceprint signals from circuit breakers.Subsequently,the component separation method was used to decompose the voiceprint signals of multiple faults into individual component signals.Based on this,the recognition of the features of a single-fault voiceprint signal can be achieved.Finally,multiple faults in high-voltage circuit breakers were identified through an experimental simulation and verification of the circuit breaker voiceprint signals collected from the substation site.The research results indicate that the proposed method exhibits excellent performance for multiple mechanical faults,such as spring structures and loose internal components of circuit breakers.In addition,it provides a reference method for the real-time online monitoring of high-voltage circuit breakers. 展开更多
关键词 High voltage circuit breaker Signal separation MONITOR Multiple faults Power system
下载PDF
Particle Swarm Optimization-Support Vector Machine Model for Machinery Fault Diagnoses in High-Voltage Circuit Breakers 被引量:8
2
作者 Xiaofeng Li Shijing Wu +2 位作者 Xiaoyong Li Hao Yuan Deng Zhao 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2020年第1期104-113,共10页
According to statistic data,machinery faults contribute to largest proportion of High-voltage circuit breaker failures,and traditional maintenance methods exist some disadvantages for that issue.Therefore,based on the... According to statistic data,machinery faults contribute to largest proportion of High-voltage circuit breaker failures,and traditional maintenance methods exist some disadvantages for that issue.Therefore,based on the wavelet packet decomposition approach and support vector machines,a new diagnosis model is proposed for such fault diagnoses in this study.The vibration eigenvalue extraction is analyzed through wavelet packet decomposition,and a four-layer support vector machine is constituted as a fault classifier.The Gaussian radial basis function is employed as the kernel function for the classifier.The penalty parameter c and kernel parameterδof the support vector machine are vital for the diagnostic accuracy,and these parameters must be carefully predetermined.Thus,a particle swarm optimizationsupport vector machine model is developed in which the optimal parameters c andδfor the support vector machine in each layer are determined by the particle swarm algorithm.The validity of this fault diagnosis model is determined with a real dataset from the operation experiment.Moreover,comparative investigations of fault diagnosis experiments with a normal support vector machine and a particle swarm optimization back-propagation neural network are also implemented.The results indicate that the proposed fault diagnosis model yields better accuracy and e-ciency than these other models. 展开更多
关键词 high-voltage circuit breaker MACHINERY fault diagnosis WAVELET PACKET decomposition Support vector machine
下载PDF
Fluid-chemical modeling of the near-cathode sheath formation process in a high current broken in DC air circuit breaker
3
作者 彭世东 李静 +3 位作者 段薇 曹云东 刘树鑫 黄浩 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期523-538,共16页
When the contacts of a medium-voltage DC air circuit breaker(DCCB) are separated, the energy distribution of the arc is determined by the formation process of the near-electrode sheath. Therefore, the voltage drop thr... When the contacts of a medium-voltage DC air circuit breaker(DCCB) are separated, the energy distribution of the arc is determined by the formation process of the near-electrode sheath. Therefore, the voltage drop through the near-electrode sheath is an important means to build up the arc voltage, which directly determines the current-limiting performance of the DCCB. A numerical model to describe the near-electrode sheath formation process can provide insight into the physical mechanism of the arc formation, and thus provide a method for arc energy regulation. In this work, we establish a two-dimensional axisymmetric time-varying model of a medium-voltage DCCB arc when interrupted by high current based on a fluid-chemical model involving 16 kinds of species and 46 collision reactions. The transient distributions of electron number density, positive and negative ion number density, net space charge density, axial electric field, axial potential between electrodes, and near-cathode sheath are obtained from the numerical model. The computational results show that the electron density in the arc column increases, then decreases, and then stabilizes during the near-cathode sheath formation process, and the arc column's diameter gradually becomes wider. The 11.14 V–12.33 V drops along the17 μm space charge layer away from the cathode(65.5 k V/m–72.5 k V/m) when the current varies from 20 k A–80 k A.The homogeneous external magnetic field has little effect on the distribution of particles in the near-cathode sheath core,but the electron number density at the near-cathode sheath periphery can increase as the magnetic field increases and the homogeneous external magnetic field will lead to arc diffusion. The validity of the numerical model can be proven by comparison with the experiment. 展开更多
关键词 near-cathode sheath atmospheric pressure air arc fluid-chemical model high current DC air circuit breaker(DCCB)
下载PDF
Analysis of Arc Characteristics and Flow Field in Arc Chamber of High-Voltage SF_6 Auto-Expansion Circuit Breaker 被引量:2
4
作者 张俊民 陈长 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第5期594-599,共6页
A new magnetic hydro-dynamics model for nozzle arc emphasizing the interaction ofarc with PTFE(polytetrafluorethylene)vapour is established based on the conservation equations.The interruption of auto-expansion circui... A new magnetic hydro-dynamics model for nozzle arc emphasizing the interaction ofarc with PTFE(polytetrafluorethylene)vapour is established based on the conservation equations.The interruption of auto-expansion circuit breaker is simulated numerically by finite elementmethod and the influence of PTFE vapour on the arc is analysed with this model.The resultsreveal that the flow field inside the arc chamber is determined by the arc current,the arcingtime,the nozzle arc and the clogging of its thermal boundary.The establishment of quenchingpressure relies on both SF6 gas and PTFE vapour that absorbed arc energy in the nozzle.ThePTFE vapour leads to an increase in the pressure of nozzle arc obviously,and a decrease in thetemperature of arc.But it enhances the temperature of arc at zero current and slows down thedecreasing rate of arc temperature as the current decreases. 展开更多
关键词 六氟化硫自动膨胀断路器 电弧 聚四氟乙烯蒸汽 电弧腔 流场
下载PDF
Magneto-hydrodynamic simulation study of direct current multi-contact circuit breaker for equalizing breaking arc
5
作者 贾博文 武建文 +4 位作者 李枢 吴昊 彭向军 戴健 陈儒盎 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第2期207-215,共9页
This work is based on a direct current(DC)natural current commutation topology,which uses load-carrying branch contacts carrying rated current and multiple sets of series arcing branch contacts in parallel to achieve ... This work is based on a direct current(DC)natural current commutation topology,which uses load-carrying branch contacts carrying rated current and multiple sets of series arcing branch contacts in parallel to achieve circuit breaking.The proposed topology can meet the new requirements of higher voltage DC switches in aviation,aerospace,energy and other fields.First,a magneto-hydrodynamic arc model is built using COMSOL Multiphysics,and the different arc breaking characteristics of the arcing branch contacts in different gas environments are simulated.Then,a voltage uniformity coefficient is used to measure the voltage sharing effect in the process of dynamic interruption.In order to solve the dispersion of arcing contact action,a structural control method is adopted to improve the voltage uniformity coefficient.The uniform voltage distribution can improve the breaking capacity and electrical life of the series connection structure. 展开更多
关键词 DC circuit breaker voltage uniformity coefficient MHD modelling uniform-voltage regulation method
下载PDF
Influence of the axial magnetic field on sheath development after current zero in a vacuum circuit breaker 被引量:2
6
作者 陈毅 杨飞 +3 位作者 孙昊 吴翊 纽春萍 荣命哲 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第6期20-25,共6页
After current zero,which is the moment when the vacuum circuit breaker interrupts a vacuum arc,sheath development is the first process in the dielectric recovery process.An axial magnetic field(AMF) is widely used in ... After current zero,which is the moment when the vacuum circuit breaker interrupts a vacuum arc,sheath development is the first process in the dielectric recovery process.An axial magnetic field(AMF) is widely used in the vacuum circuit breaker when the high-current vacuum arc is interrupted.Therefore,it is very important to study the influence of different AMF amplitudes on the sheath development.The objective of this paper is to study the influence of different AMF amplitudes on the sheath development from a micro perspective.Thus,the particle in cell-Monte Carlo collisions(PIC-MCC) method was adopted to develop the sheath development model.We compared the simulation results with the experimental results and then validated the simulation.We also obtained the speed of the sheath development and the energy density of the ions under different AMF amplitudes.The results showed mat the larger the AMF amplitudes are,the faster the sheath develops and the lower the ion energy density is,meaning the breakdown is correspondingly more difficult. 展开更多
关键词 vacuum arc SHEATH PIC-MCC axial magnetic field vacuum circuit breakers
下载PDF
Numerical Study on Arc Plasma Behavior During Arc Commutation Process in Direct Current Circuit Breaker 被引量:36
7
作者 杨飞 马瑞光 +3 位作者 吴翊 孙昊 纽春萍 荣命哲 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第2期167-171,共5页
This paper focuses on the numerical investigation of arc plasma behavior during arc commutation process in a medium-voltage direct current circuit breaker(DCCB) contact system.A three-dimensional magneto-hydrodynamic(... This paper focuses on the numerical investigation of arc plasma behavior during arc commutation process in a medium-voltage direct current circuit breaker(DCCB) contact system.A three-dimensional magneto-hydrodynamic(MHD) model of air arc plasma in the contact system of a DCCB is developed,based on commercial software FLUENT.Coupled electromagnetic and gas dynamic interactions are considered as usual,and a thin layer of nonlinear electrical resistance elements is used to represent the voltage drop of plasma sheath and the formation of new arc root.The distributions of pressure,temperature,gas flow and current density of arc plasma in arc region are calculated.The simulation results indicate that the pressure distribution related to the contact system has a strong effect on the arc commutation process,arising from the change of electrical conductivity in the arc root region.In DCCB contact system,the pressure of arc root region will be concentrated and higher if the space above the moving contact is enclosed,which is not good for arc root commutation.However,when the region is opened,the pressure distribution would be lower and more evenly,which is favorable for the arc root commutation. 展开更多
关键词 电弧等离子体 直流断路器 数值研究 换流过程 行为 压力分布 FLUENT 接触系统
下载PDF
Influence of dc Component during Inadvertent Operation of the High Voltage Generator Circuit Breaker during Mis-Synchronization 被引量:2
8
作者 Kadri Kadriu Ali Gashi +2 位作者 Ibrahim Gashi Ali Hamiti Gazmend Kabashi 《Energy and Power Engineering》 2013年第3期225-235,共11页
This paper analyses the synchronization problem of a generator onto power system without satisfying synchronization condition. The main focus of the paper is on the impact of the dc component of the current in the hig... This paper analyses the synchronization problem of a generator onto power system without satisfying synchronization condition. The main focus of the paper is on the impact of the dc component of the current in the high voltage circuit breaker during its close-open operating cycle. Using real time measurements of currents/voltages and angles during the close-opening cycle of high voltage generator circuit breaker and the impact of the dc component of current in context of interrupting large magnitude of current from the circuit breaker. In addition, the paper describes a study case model and the results of simulations performed using the software EMTP-ATP of an actual incident that occurred during the inadvertent synchronization of a large 339 MW, 24 kV generator to the grid. 展开更多
关键词 High Voltage GENERATOR circuit breaker dc Component of CURRENT ASYNCHRONOUS Connection Delay CURRENT ZERO
下载PDF
Research on arc root stagnation when small current is interrupted in self-excited circuit breaker 被引量:3
9
作者 彭世东 李静 +2 位作者 曹云东 黄翀阳 刘树鑫 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第11期14-25,共12页
The self-excited DC air circuit breaker(SE-DCCB)has been widely used in urban rail transit due to its excellent stability.It can realize forward and reverse interruption,but has difficulty interrupting small currents ... The self-excited DC air circuit breaker(SE-DCCB)has been widely used in urban rail transit due to its excellent stability.It can realize forward and reverse interruption,but has difficulty interrupting small currents due to the phenomenon of arc root sticking at the entrance of the arc chamber in the splitting process,which is known as arc root stagnation.A coupling model of the self-excited magnetic field and magnetohydrodynamics is established for the SE-DCCB with the traditional structure.The magnetic field,temperature and airflow distribution in the arc chamber are investigated with an interrupting current of 150 A.The simulation results show that the direction and magnitude of the magnetic blowout force are the dominant factors in the arc root stagnation.The local high temperature of the arc chamber due to arc root stagnation increases the obstruction effect of the airflow vortex on the arc root movement,which significantly increases the arc duration time of small current interruption.Based on the research,the structure of the magnetic conductance plate of the actual product is improved,which can improve the direction and magnitude of the magnetic blowout force at the arc root so as to restrain the development of the airflow vortex effectively and solve the problem of arc root stagnation when the small current is interrupted.The simulation results show that the circuit breaker with improved structure has a better performance for a small current interruption range from 100 A to 350 A. 展开更多
关键词 self-excited DC air circuit breaker small current interruption magnetic blowout force arc root stagnation airflow vortex
下载PDF
Method of Mechanical Fault Intelligent Diagnosis Based on Vibration Signal of High Voltage Circuit Breaker 被引量:1
10
作者 YANG Zhuangzhuang LIU Yang +3 位作者 ZHOU Guoming LIN Xin JI Tian LI Bin 《高压电器》 CAS CSCD 北大核心 2014年第4期1-6,共6页
Based on vibration signal of high voltage circuit breaker,a new method of intelligent fault diagnosis that wavelet packet extracts energy entropy which are used as characteristic vector of the support vector machine(S... Based on vibration signal of high voltage circuit breaker,a new method of intelligent fault diagnosis that wavelet packet extracts energy entropy which are used as characteristic vector of the support vector machine(SVM)to construct classifier for fault diagnosis is presented.The acceleration sensors are applied to collecting the vibration data of different states of high voltage circuit breakers based on self-made experimental platform in this method.The wavelet packet are fully applied to analyze the vibration signal and decompose vibration signal into three layers,and wavelet packet energy entropy of each frequency band are as the characteristic vector of circuit breaker failure mode.Then the intelligent diagnosis network is established on the basis of the support vector machine theory.It is verified that the method has a better capability of classification and a higher accuracy compared with the traditional neural network diagnosis method through distinguishing the three fault modes which are tripping device stuck,the vacuum arcing chamber fixed bolt looseness and too much friction force of the transmission mechanism of circuit breaker in this paper. 展开更多
关键词 SVM energy entropy high voltage circuit breaker intelligent diagnosis
下载PDF
Key stress extraction and equivalent test method for hybrid DC circuit breaker 被引量:4
11
作者 Chong Gao Xiao Ding +2 位作者 Guangfu Tang Gaoyong Wang Peng Qiu 《Global Energy Interconnection》 2018年第1期29-38,共10页
Firstly, relevant stress properties of millisecond level breaking process and microsecond level commutation process of hybrid HVDC circuit breaker are studied in detail on the basis of the analysis for the application... Firstly, relevant stress properties of millisecond level breaking process and microsecond level commutation process of hybrid HVDC circuit breaker are studied in detail on the basis of the analysis for the application environment and topological structure and operating principles of hybrid circuit breakers, and key stress parameters in transient state process of two time dimensions are extracted. The established digital simulation circuit for PSCAD/EMTDC device-level operation of the circuit breaker has verified the stress properties of millisecond level breaking process and microsecond level commutation process. Then, equivalent test method, circuits and parameters based on LC power supply are proposed on the basis of stress extraction. Finally, the results of implemented breaking tests for complete 200 kV circuit breaker, 100 kV and 50 kV circuit breaker units, as well as single power electronic module have verified the accuracy of the simulation circuit and mathematical analysis. The result of this paper can be a guide to electrical structure and test system design of hybrid HVDC circuit breaker. 展开更多
关键词 MMC-HVDC IGBT series valve Hybrid DC circuit breaker STRESS EQUIVALENCE Test method
下载PDF
Research on the overload protection reliability of moulded case circuit-breakers and its test device 被引量:14
12
作者 LI Kui LU Jian-guo WU Yi QIN Zhi-jun YAO Dong-mei 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第3期453-458,共6页
This paper analyzed the reliability and put forward the reliability index of overload protection for moulded case circuit breaker. The success rate was adopted as its reliability index of overload protection. Based on... This paper analyzed the reliability and put forward the reliability index of overload protection for moulded case circuit breaker. The success rate was adopted as its reliability index of overload protection. Based on the reliability index and the reli- ability level, the reliability examination plan was analyzed and a test device for the overload protection of moulded case cir- cuit-breaker was developed. In the reliability test of overload protection, two power sources were used, which reduced the time of conversion and regulation between two different test currents in the overload protection test, which made the characteristic test more accurate. The test device was designed on the base of a Windows system, which made its operation simple and friendly. 展开更多
关键词 超负载防护 可靠性 测试器 塑壳式断路器
下载PDF
Vacuum Dielectric Recovery Characteristics of a Novel Current Limiting Circuit Breaker Base on Artificial Current Zero 被引量:20
13
作者 JIANG Zhuangxian ZHUANG Jinwu WANG Chen WU Jin LIU Luhui 《中国电机工程学报》 EI CSCD 北大核心 2012年第13期I0021-I0021,204,共1页
为了保证新型强迫换流型真空直流限流断路器关断短路电流的可靠性,对该型断路器分断过程的真空介质恢复特性进行研究。设计了与断路器关断过程等效的介质恢复试验方案,通过等效试验结果和理论推演公式的拟合,得到了新型强迫换流型限... 为了保证新型强迫换流型真空直流限流断路器关断短路电流的可靠性,对该型断路器分断过程的真空介质恢复特性进行研究。设计了与断路器关断过程等效的介质恢复试验方案,通过等效试验结果和理论推演公式的拟合,得到了新型强迫换流型限流断路器真空灭弧室触头打开过程的动态介质强度恢复规律。研究结果表明:减小燃弧能量、提高触头运动速度可提高真空灭弧室介质的临界击穿电压;综合考虑燃弧时间与燃弧能量及触头开距的关系,随着燃弧时间的增加,真空灭弧室临界击穿电压先减小后增大。所得介质恢复规律可以作为新型断路器优化设计的参考依据。 展开更多
关键词 零电流开关 电路断路器 限流断路器 真空灭弧室 恢复特性 介质 人工 直流电气系统
下载PDF
New Breakdown Electric Field Calculation for SF6 High Voltage Circuit Breaker Applications 被引量:10
14
作者 Ph.ROBIN-JOUAN M.YOUSFI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2007年第6期690-694,共5页
The critical electric fields of hot SF_6 are calculated including both electron andion kinetics in wide ranges of temperature and pressure,namely from 300 K up to 4000 K and2 atmospheres up to 32 atmospheres respectiv... The critical electric fields of hot SF_6 are calculated including both electron andion kinetics in wide ranges of temperature and pressure,namely from 300 K up to 4000 K and2 atmospheres up to 32 atmospheres respectively.Based on solving a multi-term electron Boltz-mann equation the calculations use improved electron-gas collision cross sections for twelve SF_6dissociation products with a particular emphasis on the electron-vibrating molecule interactions.The ion kinetics is also considered and its role on the critical field becomes non negligible as thetemperature is above 2000 K.These critical fields are then used in hydrodynamics simulationswhich correctly predict the circuit breaker behaviours observed in the case of breaking tests. 展开更多
关键词 故障电领域 热解离技术 气体回路 电路
下载PDF
A Fault Current Limiting Hybrid DC Circuit Breaker 被引量:1
15
作者 Lei Huang Qian Zhang +1 位作者 Wenlei Liu Ruixue Liu 《Energy Engineering》 EI 2022年第2期621-636,共16页
Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC g... Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC grid.In order to suppress the rising speed of the fault current and reduce the current interruption requirements of the main breaker(MB),a fault current limiting hybrid DC circuit breaker(FCL-HCB)has been proposed in this paper,and it has the capability of bidirectional fault current limiting and fault current interruption.After the occurrence of the overcurrent in the HVDC grid,the current limiting circuit(CLC)of FCL-HCB is put into operation immediately,and whether the protected line is cut off or resumed to normal operation is decided according to the fault detection result.Compared with the traditional hybrid DC circuit breaker(HCB),the required number of semiconductor switches and the peak value of fault current after fault occurs are greatly reduced by adopting the proposed device.Extensive simulations also verify the effectiveness of the proposed FCL-HCB. 展开更多
关键词 Fault current limiting hybrid DC circuit breaker(FCL-HCB) high voltage direct current(HVDC)grid fault current limiting fault current interruption DC circuit breaker
下载PDF
Simulation and Experimental Analysis of Arc Motion Characteristics in Air Circuit Breaker 被引量:2
16
作者 纽春萍 丁炬文 +4 位作者 吴翊 杨飞 董得龙 范星宇 荣命哲 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第3期241-246,共6页
In this paper,to simulate the arc motion in an air circuit breaker(ACB),a threedimensional magneto-hydrodynamic(MHD) model is developed,considering the influence of thermal radiation,the change of physical parameters ... In this paper,to simulate the arc motion in an air circuit breaker(ACB),a threedimensional magneto-hydrodynamic(MHD) model is developed,considering the influence of thermal radiation,the change of physical parameters of arc plasma and the nonlinear characteristic of ferromagnetic material.The distributions of pressure,temperature,gas flow and current density of arc plasma in the arc region are calculated.The simulation results show some phenomena which discourage arc interruption,such as back commutation and arc burning at the back of the splitter plate.To verify the simulation model,the arc motion is studied experimentally.The influences of the material and position of the innermost barrier plate are analyzed mainly.It proved that the model developed in this paper can efficiently simulate the arc motion.The results indicate that the insulation barrier plate close to the top of the splitter plate is conducive to the arc splitting,which leads to the significant increase of the arc voltage,so it is better for arc interruption.The research can provide methods and references to the optimization of ACB design. 展开更多
关键词 空气断路器 电弧运动 实验分析 仿真结果 运动特性 电弧等离子体 电流密度分布 仿真模型
下载PDF
Study on the instantaneous protection reliability of low voltage circuit breakers 被引量:8
17
作者 LU Jian-guo DU Tai-hang LUO Yan-yan 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第3期370-377,共8页
This paper outlines the significance of enhancing the instantaneous protection reliability of low voltage circuit breakers and describes their main failure modes. The instantaneous failure mechanism of low voltage cir... This paper outlines the significance of enhancing the instantaneous protection reliability of low voltage circuit breakers and describes their main failure modes. The instantaneous failure mechanism of low voltage circuit breakers was analyzed so that measures to improve instantaneous protection reliability can be determined. Furthermore, the theory of the instantaneous characteristics calibration device for low voltage circuit breakers and the method of eliminating the non-periodic component of test current are given in detail. Finally, the test results are presented. 展开更多
关键词 低压电路 舜时保护 电流 电子技术
下载PDF
The Voltage Distribution Characteristics of a Hybrid Circuit Breaker During High Current Interruption 被引量:7
18
作者 程显 段雄英 +3 位作者 廖敏夫 黄智慧 罗彦 邹积岩 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第8期800-806,共7页
Hybrid circuit breaker (HCB) technology based on a vacuum interrupter and a SF6 interrupter in series has become a new research direction because of the low-carbon requirements for high voltage switches. The vacuum in... Hybrid circuit breaker (HCB) technology based on a vacuum interrupter and a SF6 interrupter in series has become a new research direction because of the low-carbon requirements for high voltage switches. The vacuum interrupter has an excellent ability to deal with the steep rising part of the transient recovery voltage (TRV), while the SF6 interrupter can withstand the peak part of the voltage easily. An HCB can take advantage of the interrupters in the current interruption process. In this study, an HCB model based on the vacuum ion diffusion equations, ion density equation, and modified Cassie-Mayr arc equation is explored. A simulation platform is constructed by using a set of software called the alternative transient program (ATP). An HCB prototype is also designed, and the short circuit current is interrupted by the HCB under different action sequences of contacts. The voltage distribution of the HCB is analyzed through simulations and tests. The results demonstrate that if the vacuum interrupter withstands the initial TRV and interrupts the post-arc current first, then the recovery speed of the dielectric strength of the SF6 interrupter will be fast. The voltage distribution between two interrupters is determined by their post-arc resistance, which happens after current-zero, and subsequently, it is determined by the capacitive impedance after the post-arc current decays to zero. 展开更多
关键词 电压分布特性 混合式断路器 高电流 中断 真空灭弧室 瞬态恢复电压 电弧电流 SF6
下载PDF
Study on the Mathematical Model of Dielectric Recovery Characteristics in High Voltage SF6 Circuit Breaker 被引量:13
19
作者 林莘 王飞鸣 +2 位作者 徐建源 夏亚龙 刘卫东 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第3期223-229,共7页
According to the stream theory,this paper proposes a mathematical model of the dielectric recovery characteristic based on the two-temperature ionization equilibrium equation.Taking the dynamic variation of charged pa... According to the stream theory,this paper proposes a mathematical model of the dielectric recovery characteristic based on the two-temperature ionization equilibrium equation.Taking the dynamic variation of charged particle's ionization and attachment into account,this model can be used in collaboration with the Coulomb collision model,which gives the relationship of the heavy particle temperature and electron temperature to calculate the electron density and temperature under different pressure and electric field conditions,so as to deliver the breakdown electric field strength under different pressure conditions.Meanwhile an experiment loop of the circuit breaker has been built to measure the breakdown voltage.It is shown that calculated results are in conformity with experiment results on the whole while results based on the stream criterion are larger than experiment results.This indicates that the mathematical model proposed here is more accurate for calculating the dielectric recovery characteristic,it is derived from the stream model with some improvement and refinement and has great significance for increasing the simulation accuracy of circuit breaker's interruption characteristic. 展开更多
关键词 高压SF6断路器 数学模型 恢复特性 介质 击穿电场强度 压力条件 计算结果 平衡方程
下载PDF
Influence of Shock Wave on Turbulence in SF_6 Puffer Circuit Breaker 被引量:2
20
作者 张建 贾申利 +2 位作者 李兴文 史宗谦 王立军 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第1期76-80,共5页
Influence of the shock wave on the turbulence in a supersonic nozzle was investigatedfor a SF_6 puffer circuit breaker interruption process. Turbulence is enlarged through the shockwave. Baroclinic generation of vorte... Influence of the shock wave on the turbulence in a supersonic nozzle was investigatedfor a SF_6 puffer circuit breaker interruption process. Turbulence is enlarged through the shockwave. Baroclinic generation of vortex causes flow separation and broadening of the arc crosssection. V-I characteristics are slightly modified due to the shock wave's influence. 展开更多
关键词 六氟化硫断路器 湍流 激波 超音速喷嘴 冲击波 开断过程 流动分离 截面
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部