期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Relativistic Configuration Interaction Calculations on Kα X-Ray Satellites of Manganese 被引量:1
1
作者 LI Hui-Li LI Ping CHENG Zhang MA Hai-Rong 《Communications in Theoretical Physics》 SCIE CAS CSCD 2008年第1期217-220,共4页
With contributions from Breit interaction, quantum electrodynarnics (QED) corrections and nuclear mass corrections to the initial and final levels are taken into account. The transition energies, transition probabil... With contributions from Breit interaction, quantum electrodynarnics (QED) corrections and nuclear mass corrections to the initial and final levels are taken into account. The transition energies, transition probabilities, and absorption oscillator strengths of Kα x-ray from Mn XVII to Mn XXIV have been calculated by using relativistic configuration interaction (RCI) and multi-configuration Dirac Fock (MCDF) method in the active interaction approach. Compared with the only available experimental transition data on He-like and Li-like manganese, the present results are in good agreement with them, and the rest of transition data of the present results are new ones. These wide range data can provide useful parameters for the study of the manganese plasma. 展开更多
关键词 TRANSITION highly ionized Mn relativistic configuration interaction multi-configuration DiracFock method
下载PDF
Spectra and oscillator strengths of 3p^63d^9-3p^53d^(10) and 3p^63d^9-3p^63d^84p transitions for cobalt-like Sn^(23+) ion
2
作者 陈明伦 余晓光 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第1期157-160,共4页
This paper calculates the spectra and oscillator strengths for highly ionized cobalt-like Sn^23+ ions 3p^63d^9- 3p^53d^10, 3p^63d^9 - 3p^63d^84p transitions by using a multi-configuration self-consistent field method... This paper calculates the spectra and oscillator strengths for highly ionized cobalt-like Sn^23+ ions 3p^63d^9- 3p^53d^10, 3p^63d^9 - 3p^63d^84p transitions by using a multi-configuration self-consistent field method program together with the proposed fitting formula. The calculations have a good agreement with observations. 展开更多
关键词 highly ionized energy level the fitting formula
下载PDF
Experimental Study of a Minitype Atmospheric Non-equilibrium Plasma Source 被引量:2
3
作者 白希尧 周建刚 +2 位作者 邱秀梅 刘栋 白敏冬 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第6期724-726,共3页
A mini-type of plasma source was studied experimentally. The results showed that the plasma density, which was generated by an atmospheric non-equilibrium plasma source, rises with the increase in driving electric-fie... A mini-type of plasma source was studied experimentally. The results showed that the plasma density, which was generated by an atmospheric non-equilibrium plasma source, rises with the increase in driving electric-field and the momentum of gas particles. For a driving electricfield of 56 kV/cm and a gas particles' momentum of 10^9 × 10^-22 g·m/s, the ion density can exceed 10^10/cm^3 while the effective volume of the plasma source is only 2.5 cm^2. This study may help develop a method to generate a minitype plasma source with low energy consumption but high ion concentration. This source can be used in chemical industry, environmental engineering and military applications. 展开更多
关键词 atmosphere high voltage ionizing source ion density gas particle momentum electric discharging non-equilibrium plasma
下载PDF
Metabolomic profiling for identification of metabolites and relevant pathways for taurine in hepatic stellate cells 被引量:4
4
作者 Xin Deng Xing-Qiu Liang +3 位作者 Fei-Guo Lu Xiao-Fang Zhao Lei Fu Jian Liang 《World Journal of Gastroenterology》 SCIE CAS 2017年第31期5713-5721,共9页
AIM To develop a reliable and simple method to identify important biological metabolites and relevant pathways for taurine in hepatic stellate cells(HSCs), in order to provide more data for taurine therapy.METHODS All... AIM To develop a reliable and simple method to identify important biological metabolites and relevant pathways for taurine in hepatic stellate cells(HSCs), in order to provide more data for taurine therapy.METHODS All the biological samples were analyzed by using highperformance liquid chromatography-time electrospray ionization/quadrupole-time of flight mass spectrometry. Principal component analysis and partial least squares discriminant analysis were used to identify statistically different metabolites for taurine in HSCs, and metabolomic pathway analysis was used to do pathway analysis for taurine in HSCs. The chemical structure of the related metabolites and pathways was identified by comparing the m/z ratio and ion mode with the data obtained from free online databases.RESULTS A total of 32 significant differential endogenous metabolites were identified, which may be related to the mechanism of action of taurine in HSCs. Among the seven relevant pathways identified, sphingolipid metabolism pathway, glutathione metabolism pathway and thiamine metabolism pathway were found to be the most important metabolic pathways for taurine in HSCs.CONCLUSION This study showed that there were distinct changes in biological metabolites of taurine in HSCs and three differential metabolic pathways including sphingolipid pathway, glutathione pathway and thiamine metabolism pathway might be of key importance in mediating the mechanism of action of taurine in HSCs. 展开更多
关键词 Natural taurine Hepatic stellate cells Pathway High performance liquid chromatographytime electrospray ionization/quadrupole-time of flight mass spectrometry Metabolomics
下载PDF
Quantitative determination of ilexgenin A in rat plasma by liquid chromatography coupled with mass spectrometry and its pharmacokinetics 被引量:2
5
作者 柳文媛 李萍 +2 位作者 冯锋 余成霞 丁黎 《Journal of Chinese Pharmaceutical Sciences》 CAS 2010年第1期38-42,共5页
A sensitive and selective high performance liquid chromatography coupled with electrospray ionization mass spectrometry (LC-MS) was developed for the quantitative determination of ilexgenin A (IA),a major componen... A sensitive and selective high performance liquid chromatography coupled with electrospray ionization mass spectrometry (LC-MS) was developed for the quantitative determination of ilexgenin A (IA),a major component in Radix Ilicis Pubescentis,in rat plasma.Chromatographic separation was performed on a C 18 column,with methanol-5 mM ammonium acetate (80:20,v/v) as the mobile phase.Mass spectrometer was set in negative mode with target ions at m/z 501.1→501.1 for IA and m/z 779.4→779.4 for digoxin (internal standard,IS).Rat plasma was extracted with ethyl acetate after addition of phosphoric solution and the organic layer was evaporated and reconstituted with mobile phase for LC-MS analysis.The proposed method was validated with a linear range of 1.05-525.5 ng/mL for IA with limit of quantitation (LOQ) at 1.05 ng/mL.Intra-and inter-day precision expressed as relative standard deviation (RSD) were less than 10% at LOQ level and overall recovery was over 80%.This validated method was used successfully for the pharmacokinetic study of IA in rats after oral dosing of IA (100 mg/kg) and some main pharmacokinetic parameters of IA in rats were obtained. 展开更多
关键词 High performance liquid chromatography Electrospray ionization mass spectrometry Ilexgenin A Radix Ilicis Pubescentis Pharmacokinetic study
原文传递
Study of the energy response of high pressure ionization chamber for high energy gamma-ray 被引量:4
6
作者 花正东 许浔江 +2 位作者 王建华 刘曙东 李建平 《Chinese Physics C》 SCIE CAS CSCD 北大核心 2008年第5期370-372,共3页
The energy response calibration of the commonly used high pressure ionization chamber is very difficult to obtain when the gamma-ray energy is more than 3 MeV. In order to get the calibration of the higher part of the... The energy response calibration of the commonly used high pressure ionization chamber is very difficult to obtain when the gamma-ray energy is more than 3 MeV. In order to get the calibration of the higher part of the high pressure ionization chamber, we use the Fluka Monte Carlo program to perform the energy response in both the spherical and the cylindrical high pressure ionization chamber which are full of argon gas. The results compared with prior study when the gamma-ray energy is less than 1.25 MeV. Our result of Monte Carlo calculation shows agreement with those obtained by measurement within the uncertainty of the respective methods. The calculation of this study is significant for the high pressure ionization chamber to measure the high energy gamma-ray. 展开更多
关键词 high pressure ionization chamber Fluka program energy response
原文传递
Observational connection between local high-temperature phenomena within magnetic clouds and the Sun 被引量:2
7
作者 WANG JieMin FENG HengQiang 《Science China Earth Sciences》 SCIE EI CAS CSCD 2016年第5期1051-1056,共6页
Magnetic clouds(MCs) frequently show abnormal high-ionization states of heavy ions. The abnormal high-charge distributions are related to the coronal temperature of their source regions. We examined the plasma and mag... Magnetic clouds(MCs) frequently show abnormal high-ionization states of heavy ions. The abnormal high-charge distributions are related to the coronal temperature of their source regions. We examined the plasma and magnetic field data of 74 MCs observed by the Advanced Composition Explorer from February 1998 to December 2008. We determined that 14 of the 74 events showed local high-temperature phenomena. We analyzed the correlation between proton temperature and O7/O6ratio(or high mean Fe charge state ?Fe?) within the local high-temperature regions in the 14 MCs. Results show that proton temperature and O7/O6 ratio(or high mean Fe charge state) had good correlations in nine MCs, but had no evident correlation in the other five MCs. The local high-temperature phenomena within the nine MCs have resulted from the Sun. 展开更多
关键词 Magnetic cloud Ion ionization state High temperature proton
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部