The condition of bolted connections significantly affects the structural safety.However,conventional bolt tension sensors fail to provide precise measurements due to their bulky size or inadequate stability.This study...The condition of bolted connections significantly affects the structural safety.However,conventional bolt tension sensors fail to provide precise measurements due to their bulky size or inadequate stability.This study employs the piezoresistive effect of crystalline silicon material to fabricate an ultrathin sensor.The sensor exhibits a linear relationship between pressure and voltage,an exceptional stability at varying temperatures,and a superior resistance to corrosion,making it adaptable and user-friendly for applications of high-strength bolt tension monitoring.A monitoring system,incorporating the proposed sensor,has also been developed.This system provides real-time display of bolt tension and enables the assessment of sensor and structural conditions,including bolt loosening or component failure.The efficacy of the proposed sensor and monitoring system was validated through a project carried out at the Xiluodu Hydropower Plant.According to the results,the sensor and online monitoring system effectively gauged and proficiently conveyed and stored bolt tension data.In addition,correlations were created between bolt tensions and essential unit parameters,such as water head,active power,and pressures at vital points,facilitating anomaly detection and early warning.展开更多
When the electronic temperature sensor was incorporated into a system of soil water tension and the insidetube temperature was monitored in real time, it is concluded that the inside temperature increased by 26.9 ℃ a...When the electronic temperature sensor was incorporated into a system of soil water tension and the insidetube temperature was monitored in real time, it is concluded that the inside temperature increased by 26.9 ℃ and the inside pressure changed about 14.6 Kpa, when the pottery soil was replaced by the sealing plug. When the soil water was relatively stable in the experimental salvers, the in-side pressure stil varied regularly with the temperature. When the inside temperature increased by 22.2 ℃, the inside pressure varied about 7.4 Kpa. Through com-pensation calculation of the inside tension, the temperature in the warming and cooling periods was compensated, which was useful to correct the tension measurement errors induced from the changing temperature. When the measuring interval was 4 hours and the temperature difference was 18.1 ℃, the tension difference of both points was only 0.278 Kpa, compared to the difference up to 6.5 Kpa before compensation.展开更多
磁通量索力传感器(Elasto-Magnetic force sensor,EM sensor)作为一种非接触式测量的传感器,与其他索力传感器相比,具有长期稳定性与可靠性好、耐久性高、使用寿命长的突出优势,在预应力拉索的索力监测上应用广泛。本文对磁通量索力传...磁通量索力传感器(Elasto-Magnetic force sensor,EM sensor)作为一种非接触式测量的传感器,与其他索力传感器相比,具有长期稳定性与可靠性好、耐久性高、使用寿命长的突出优势,在预应力拉索的索力监测上应用广泛。本文对磁通量索力传感器的工作原理、发展脉络及研究热点进行阐述,对该技术工程应用的状况与面临的难题进行总结,并对传感器的技术发展趋势进行讨论与展望,以期为相关领域的研究人员在磁通量索力传感器应用及技术上的研究提供参考。展开更多
文摘The condition of bolted connections significantly affects the structural safety.However,conventional bolt tension sensors fail to provide precise measurements due to their bulky size or inadequate stability.This study employs the piezoresistive effect of crystalline silicon material to fabricate an ultrathin sensor.The sensor exhibits a linear relationship between pressure and voltage,an exceptional stability at varying temperatures,and a superior resistance to corrosion,making it adaptable and user-friendly for applications of high-strength bolt tension monitoring.A monitoring system,incorporating the proposed sensor,has also been developed.This system provides real-time display of bolt tension and enables the assessment of sensor and structural conditions,including bolt loosening or component failure.The efficacy of the proposed sensor and monitoring system was validated through a project carried out at the Xiluodu Hydropower Plant.According to the results,the sensor and online monitoring system effectively gauged and proficiently conveyed and stored bolt tension data.In addition,correlations were created between bolt tensions and essential unit parameters,such as water head,active power,and pressures at vital points,facilitating anomaly detection and early warning.
基金Supported by Jiangsu Agricultural Self-innovation Fund[CX(13)3031]~~
文摘When the electronic temperature sensor was incorporated into a system of soil water tension and the insidetube temperature was monitored in real time, it is concluded that the inside temperature increased by 26.9 ℃ and the inside pressure changed about 14.6 Kpa, when the pottery soil was replaced by the sealing plug. When the soil water was relatively stable in the experimental salvers, the in-side pressure stil varied regularly with the temperature. When the inside temperature increased by 22.2 ℃, the inside pressure varied about 7.4 Kpa. Through com-pensation calculation of the inside tension, the temperature in the warming and cooling periods was compensated, which was useful to correct the tension measurement errors induced from the changing temperature. When the measuring interval was 4 hours and the temperature difference was 18.1 ℃, the tension difference of both points was only 0.278 Kpa, compared to the difference up to 6.5 Kpa before compensation.
文摘磁通量索力传感器(Elasto-Magnetic force sensor,EM sensor)作为一种非接触式测量的传感器,与其他索力传感器相比,具有长期稳定性与可靠性好、耐久性高、使用寿命长的突出优势,在预应力拉索的索力监测上应用广泛。本文对磁通量索力传感器的工作原理、发展脉络及研究热点进行阐述,对该技术工程应用的状况与面临的难题进行总结,并对传感器的技术发展趋势进行讨论与展望,以期为相关领域的研究人员在磁通量索力传感器应用及技术上的研究提供参考。