A large-span steel–concrete composite beam with precast hollow core slabs(CBHCSs)is a relatively new floor structure that can be applied to various long-span structures.However,human-induced vibrations may present se...A large-span steel–concrete composite beam with precast hollow core slabs(CBHCSs)is a relatively new floor structure that can be applied to various long-span structures.However,human-induced vibrations may present serviceability issues in such structures.To alleviate vibrations,both the walking forces excited by humans and the associated floor responses must be elucidated.In this study,150 load–time histories of walking,excited by 25 test participants,are obtained using a force measuring plate.The dynamic loading factors and phase angles in the Fourier series functions for one-step walking are determined.Subsequently,walking tests are performed on seven CBHCS specimens to capture the essential dynamic properties of mode shapes,natural frequencies,damping ratios,and acceleration time histories.The CBHCS floor system generally exhibits a high frequency(>10 Hz)and low damping(damping ratio<2%).Sensitivity studies using the finite element method are conducted to investigate the vibration performance of the CBHCS floor system,where the floor thickness,steel beam type,contact time,and human weight are considered.Finally,analytical expressions derived for the fundamental frequency and peak acceleration agree well with the experimental results and are hence proposed for practical use.展开更多
Precast prestressed Hollow Core Slabs (HCS), are one of the famous and widely used slabs for concrete structures all over the world and widely implemented in the Middle East. HCS are used in industrial, commercial, re...Precast prestressed Hollow Core Slabs (HCS), are one of the famous and widely used slabs for concrete structures all over the world and widely implemented in the Middle East. HCS are used in industrial, commercial, residential buildings, as well as, in the parking structures. This paper succeeded to present new special details for deep HCS to enhance and strengthen the web shear strength capacity of HCS 400 and 500 mm depths respectively at the open parking area. This is subjected to heavy truck wheel loads so as to achieve the LRFD Code’s requirements. However, it is noticed many web shear cracks of HCS are used at parking area at many projects in Gulf Region. On the other hand, ACI318-14 permits no shear reinforcement in prestressed HCS thickness of less than 12.5 in (320 mm). The paper presents experimental tests program, to verify the numerical finite element of deep HCS under maximum design uniform loads, in addition to the new strengthening techniques. New strengthening techniques succeed to enhance the web shear capacity by significant percentage, due to the new details for HCS 400 by 68% up to 256% increasing of the web shear capacity compared to the ordinary HCS section. Also, HCS 500 shear capacity is enhanced with different percentages of strengthening techniques by 55%, up to 197% based on the different cases of strengthening. Furthermore enhancing deep HCS shear performance;the new techniques have an advantage of an easy execution at the site;casting with structural topping, otherwise the preparation can be done in precast factory before site handover, which saves time and cost compared to the others traditional strengthening techniques.展开更多
Hollow core slabs are becoming of increasing interest as the construction industry attempts to minimise the impact of its activities on the environment. By forming voids in the interior of a concrete slab, the amount ...Hollow core slabs are becoming of increasing interest as the construction industry attempts to minimise the impact of its activities on the environment. By forming voids in the interior of a concrete slab, the amount of concrete used can be reduced without significantly altering the capacity of the structure. In this study, we examined the inner force transfer mechanism of a column-supported cast-in-situ hollow core slab using finite element analysis. Both a hollow core slab and the corresponding solid slab were analysed using ANSYS and the results were compared. The orientation of the tube fillers causes the stiffness of the hollow slab to be orthotropic, potentially changing the distribution of load carried in the two orthogonal directions. Both the cross-section’s moments in the column strip and near the columns in the hollow core slab become larger than that in the solid floor. As well, the cross-section’s stiffness along the tube arrangement direction is larger than that of the radial cross-section, which causes the direction along the hole of the hollow core slab to carry more moment than the radial direction. The conversion factors of the two directions are proposed from the comparison for four typical areas of the hollow core slab, as are the moment distribution coefficients.展开更多
为研究火灾后预应力混凝土空心板采用粘贴碳纤维布加固前后的力学性能和破坏形态,进行8块受火后加固的预应力混凝土空心板的静载试验研究,并考虑15,30,45和60 min 4种不同受火时间。研究结果表明:粘贴CFRP布加固受火损伤预制空心板能有...为研究火灾后预应力混凝土空心板采用粘贴碳纤维布加固前后的力学性能和破坏形态,进行8块受火后加固的预应力混凝土空心板的静载试验研究,并考虑15,30,45和60 min 4种不同受火时间。研究结果表明:粘贴CFRP布加固受火损伤预制空心板能有效抑制其开裂并显著提高承载力,但破坏模式由加固前的弯曲破坏转变为剪切破坏;受火加固试件初始弯曲刚度小于未受火对比试件的弯曲刚度,但后期弯曲刚度明显大于未受火对比试件的弯曲刚度。展开更多
基金The authors acknowledge the financial support provided by the National Natural Science Foundation of China(51890902 and 51708058).
文摘A large-span steel–concrete composite beam with precast hollow core slabs(CBHCSs)is a relatively new floor structure that can be applied to various long-span structures.However,human-induced vibrations may present serviceability issues in such structures.To alleviate vibrations,both the walking forces excited by humans and the associated floor responses must be elucidated.In this study,150 load–time histories of walking,excited by 25 test participants,are obtained using a force measuring plate.The dynamic loading factors and phase angles in the Fourier series functions for one-step walking are determined.Subsequently,walking tests are performed on seven CBHCS specimens to capture the essential dynamic properties of mode shapes,natural frequencies,damping ratios,and acceleration time histories.The CBHCS floor system generally exhibits a high frequency(>10 Hz)and low damping(damping ratio<2%).Sensitivity studies using the finite element method are conducted to investigate the vibration performance of the CBHCS floor system,where the floor thickness,steel beam type,contact time,and human weight are considered.Finally,analytical expressions derived for the fundamental frequency and peak acceleration agree well with the experimental results and are hence proposed for practical use.
文摘Precast prestressed Hollow Core Slabs (HCS), are one of the famous and widely used slabs for concrete structures all over the world and widely implemented in the Middle East. HCS are used in industrial, commercial, residential buildings, as well as, in the parking structures. This paper succeeded to present new special details for deep HCS to enhance and strengthen the web shear strength capacity of HCS 400 and 500 mm depths respectively at the open parking area. This is subjected to heavy truck wheel loads so as to achieve the LRFD Code’s requirements. However, it is noticed many web shear cracks of HCS are used at parking area at many projects in Gulf Region. On the other hand, ACI318-14 permits no shear reinforcement in prestressed HCS thickness of less than 12.5 in (320 mm). The paper presents experimental tests program, to verify the numerical finite element of deep HCS under maximum design uniform loads, in addition to the new strengthening techniques. New strengthening techniques succeed to enhance the web shear capacity by significant percentage, due to the new details for HCS 400 by 68% up to 256% increasing of the web shear capacity compared to the ordinary HCS section. Also, HCS 500 shear capacity is enhanced with different percentages of strengthening techniques by 55%, up to 197% based on the different cases of strengthening. Furthermore enhancing deep HCS shear performance;the new techniques have an advantage of an easy execution at the site;casting with structural topping, otherwise the preparation can be done in precast factory before site handover, which saves time and cost compared to the others traditional strengthening techniques.
基金Project supported by the Australian Research Council Research Grant (No. DP0988940)the Natural Science Foundation of Jiangsu Province (No. BK2009394)+2 种基金the China Postdoctoral Science Foundation (No. 2011M500930)the Natural Science Surface Project of Jiangsu Provincial Universities (No. 11KJB560003)the Talent Introduction Fund of Nanjing Forestry University (No. 163050072)
文摘Hollow core slabs are becoming of increasing interest as the construction industry attempts to minimise the impact of its activities on the environment. By forming voids in the interior of a concrete slab, the amount of concrete used can be reduced without significantly altering the capacity of the structure. In this study, we examined the inner force transfer mechanism of a column-supported cast-in-situ hollow core slab using finite element analysis. Both a hollow core slab and the corresponding solid slab were analysed using ANSYS and the results were compared. The orientation of the tube fillers causes the stiffness of the hollow slab to be orthotropic, potentially changing the distribution of load carried in the two orthogonal directions. Both the cross-section’s moments in the column strip and near the columns in the hollow core slab become larger than that in the solid floor. As well, the cross-section’s stiffness along the tube arrangement direction is larger than that of the radial cross-section, which causes the direction along the hole of the hollow core slab to carry more moment than the radial direction. The conversion factors of the two directions are proposed from the comparison for four typical areas of the hollow core slab, as are the moment distribution coefficients.
文摘为研究火灾后预应力混凝土空心板采用粘贴碳纤维布加固前后的力学性能和破坏形态,进行8块受火后加固的预应力混凝土空心板的静载试验研究,并考虑15,30,45和60 min 4种不同受火时间。研究结果表明:粘贴CFRP布加固受火损伤预制空心板能有效抑制其开裂并显著提高承载力,但破坏模式由加固前的弯曲破坏转变为剪切破坏;受火加固试件初始弯曲刚度小于未受火对比试件的弯曲刚度,但后期弯曲刚度明显大于未受火对比试件的弯曲刚度。