Onboard air separation devices,based on hollow fiber membranes,are traditionally used for the optimization of aircraft fuel tank inerting systems.In the present study,a set of tests have been designed and executed to ...Onboard air separation devices,based on hollow fiber membranes,are traditionally used for the optimization of aircraft fuel tank inerting systems.In the present study,a set of tests have been designed and executed to assess the air separation performances of these systems for different air inlet temperatures(70°C∼110°C),inlet pressures(0.1∼0.4 MPa),volume flow rates of nitrogen-enriched air(NEA)(30∼120 L/min)and flight altitudes(1.5∼18 km).In particular,the temperature,pressure,volume flow rate,and oxygen concentration of air,NEA and oxygen-enriched air(OEA)have been measured.The experimental results show that the oxygen concentration of NEA,air separation coefficient,and nitrogen utilization coefficient decrease with the rising of air inlet temperature,air inlet pressure,and flight altitude.The effect of air inlet pressure on the above three parameters is significant,while the influence of air inlet temperature and flight altitude is relatively small.展开更多
A non-dispersive extraction technique, using an emulsion liquid membrane within a hollow-fiber-contactor for the extraction and enrichment of Nd^3+ from the dilute feed aqueous, was applied. The emulsion system is co...A non-dispersive extraction technique, using an emulsion liquid membrane within a hollow-fiber-contactor for the extraction and enrichment of Nd^3+ from the dilute feed aqueous, was applied. The emulsion system is consisted of span80 [ sorbitian monooleate], paraffin oil, D2EHPA [ 2-( 2-ethylhexyl- phosphonic acid)], kerosene as well as HCl solution. The extraction under various conditions such as the span80 concentrations, the flow rate of aqueous, the extraction time and HCl concentrations in receiving phase were studied. Results show that the lower the flow rates of aqueous are, the higher the extraction percentage and enrichment-fold are, and the extraction percentage increases with the increasing of HCl concentrations. When the initial Nd^3+ concentration in feed is maintained at 1000 mg· L^-1 and the emulsion is recycled with 70 times by a counter-flow,展开更多
基金This project is supported by the Fund of Natural Science Project of Hunan Province,China,with the Item No.2020JJ5393Education Department of Hunan Province,China,with the Item No.18C0735.
文摘Onboard air separation devices,based on hollow fiber membranes,are traditionally used for the optimization of aircraft fuel tank inerting systems.In the present study,a set of tests have been designed and executed to assess the air separation performances of these systems for different air inlet temperatures(70°C∼110°C),inlet pressures(0.1∼0.4 MPa),volume flow rates of nitrogen-enriched air(NEA)(30∼120 L/min)and flight altitudes(1.5∼18 km).In particular,the temperature,pressure,volume flow rate,and oxygen concentration of air,NEA and oxygen-enriched air(OEA)have been measured.The experimental results show that the oxygen concentration of NEA,air separation coefficient,and nitrogen utilization coefficient decrease with the rising of air inlet temperature,air inlet pressure,and flight altitude.The effect of air inlet pressure on the above three parameters is significant,while the influence of air inlet temperature and flight altitude is relatively small.
文摘A non-dispersive extraction technique, using an emulsion liquid membrane within a hollow-fiber-contactor for the extraction and enrichment of Nd^3+ from the dilute feed aqueous, was applied. The emulsion system is consisted of span80 [ sorbitian monooleate], paraffin oil, D2EHPA [ 2-( 2-ethylhexyl- phosphonic acid)], kerosene as well as HCl solution. The extraction under various conditions such as the span80 concentrations, the flow rate of aqueous, the extraction time and HCl concentrations in receiving phase were studied. Results show that the lower the flow rates of aqueous are, the higher the extraction percentage and enrichment-fold are, and the extraction percentage increases with the increasing of HCl concentrations. When the initial Nd^3+ concentration in feed is maintained at 1000 mg· L^-1 and the emulsion is recycled with 70 times by a counter-flow,