AIM: To evaluate intraocular pressure(IOP) measurements and fluctuations using the i Care ONE rebound tonometer(RT-ONE), during home monitoring, in diagnosed and suspected glaucoma patients.METHODS: A retrospective ca...AIM: To evaluate intraocular pressure(IOP) measurements and fluctuations using the i Care ONE rebound tonometer(RT-ONE), during home monitoring, in diagnosed and suspected glaucoma patients.METHODS: A retrospective case series of consecutive patients with known glaucoma or glaucoma suspects who were followed-up and treated between January 2016 and January 2017. The study included 80 eyes of 40 patients with a mean age of 59.1±14.6 y(range, 24-78). All patients have undergone 4-5 d of IOP home monitoring with RT-ONE at morning, noon, afternoon, and night time.RESULTS: Baseline mean IOP, as measured in the clinic(8 a.m.-12 p.m.), was 17.4±5.1 mm Hg, compared to RT-ONE home monitoring mean IOP of 15.6±4.1 mm Hg(P=0.002). Mean IOP was significantly lower at noon, afternoon and night times compared to clinic measured IOP and morning measurements(P=0.005). IOP peak measured during home monitoring was significantly higher compared to the clinic measured IOP(21.3±5.6 mm Hg and 17.4±5.1 mm Hg, P<0.001). IOP peaks during home monitoring demonstrated a majority of 47 peaks during morning measurements, compared to 23 at noon, 19 at afternoon and only 12 at night(P<0.001). The home monitoring results led to treatment modification of 44 eyes(55%), treatment regime was insufficient for 40(50%) eyes.CONCLUSION: Home monitoring IOP with RT-ONE can provide good assessment of mean IOP, IOP fluctuations and peaks throughout the hours of the day, which lead to an accurate treatment for glaucoma patients.展开更多
Background The impact of home monitoring system in the early detection of ventricular arrhythmia and inappropriate shock in daily work is not clear. The aim of this study was to investigate the impact of home monitori...Background The impact of home monitoring system in the early detection of ventricular arrhythmia and inappropriate shock in daily work is not clear. The aim of this study was to investigate the impact of home monitoring system on the early detection of ventricular arrhythmia and inappropriate shock in daily clinical practice. Methods Cases of implantable cardioverter defibrillator (ICD) implantation with or without the home monitoring system from June 2010 to October 2011 at our center were reviewed. Follow-up was scheduled after implantation. Data relating to the home monitoring ICD were retrieved using a remote transmitter system. Data relating to the other devices were obtained during scheduled follow-up or unscheduled visits. Results Our study involved 69 patients (mean age (68.4+17.6) years, 64.3% males, 26 in the home monitoring group vs. 43 in the non-home monitoring group). In all, 561 ventricular arrhythmia episodes were detected in 17 patients (39.5%) in the non-home monitoring group: 495 episodes were ventricular tachycardia and 66 episodes were ventricular fibrillation; among these, 476 episodes of ventricular tachycardia and 45 episodes of ventricular fibrillation were appropriately diagnosed (96.1% and 68.2%, respectively). In the home monitoring group, 389 ventricular arrhythmia episodes were transmitted by the home monitoring system in nine patients (34.6%): 348 ventricular tachycardia episodes and 41 ventricular fibrillation episodes. Device detection was appropriate in 348 ventricular tachycardia episodes (100.0%) and 36 ventricular fibrillation episodes (87.8%). The home monitoring group showed a higher appropriate detection rate of ventricular tachycardia (P 〈0.01) and ventricular fibrillation (P=0.02). The proportion of inappropriate shock was comparable in the two groups (6/11 in the non-home monitoring group vs. 1/7 in the home monitoring group; m=0.08). Conclusions The home monitoring ICD was able to provide information relating to inappropriate detection and shock earlier than conventional devices. It proved to be a reliable tool and has a strong potential to provide greater reaction time in the case of inappropriate shock.展开更多
AIM:To identify a possible role of home echocardiography for monitoring chronic heart failure(CHF)patients.METHODS:We prospectively investigated 118 patients hospitalized during the last year for CHF who could not eas...AIM:To identify a possible role of home echocardiography for monitoring chronic heart failure(CHF)patients.METHODS:We prospectively investigated 118 patients hospitalized during the last year for CHF who could not easily reach the pertaining District Healthcare Center.The patients were followed up with 2 home management programs:one including clinical and electrocardiographic evaluations and also periodic home echocardiographic examinations(group A),the other including clinical and electrocardiographic evaluations only(group B).RESULTS:At the end of the 18-mo follow-up no significant differences were observed between the 2 groups as regards the primary endpoint:rehospitalization occurred in 4 patients of the group A and in 6 patients of the group B;major cardiovascular events occurred in 2 and in 3 patients,respectively.No significant differences were observed with respect to the secondary endpoints:one vascular event appeared in both the groups,3 cardiovascular deaths occurred in group A and 2 in group B.No significant differences were observed between the 2 groups as regards the composite endpoint of death plus hospitalization.CONCLUSION:Home echocardiography for monitoring of CHF patients does not improve the cardiovascular endpoints.In our CHF patients,a low incidence of vascular events was observed.展开更多
BACKGROUND Patients discharged after hospitalization for acute heart failure(AHF) are frequently readmitted due to an incomplete decongestion, which is difficult to assess clinically. Recently, it has been shown that ...BACKGROUND Patients discharged after hospitalization for acute heart failure(AHF) are frequently readmitted due to an incomplete decongestion, which is difficult to assess clinically. Recently, it has been shown that the use of a highly sensitive,non-invasive device measuring lung impedance(LI) reduces hospitalizations for heart failure(HF); it has also been shown that this device reduces the cardiovascular and all-cause mortality of stable HF patients when used in longterm out-patient follow-ups. The aim of these case series is to demonstrate the potential additive role of non-invasive home LI monitoring in the early postdischarge period.CASE SUMMARY We present a case series of three patients who had performed daily LI measurements at home using the edema guard monitor(EGM) during 30 d after an episode of AHF. All patients had a history of chronic ischemic HF with a reduced ejection fraction and were hospitalized for 6–17 d. LI measurements were successfully made at home by patients with the help of their caregivers. The patients were carefully followed up by HF specialists who reacted to the values of LI measurements, blood pressure, heart rate and clinical symptoms. LI reduction was a more frequent trigger to medication adjustments compared to changes in symptoms or vital signs. Besides, LI dynamics closely tracked the use and dose of diuretics.CONCLUSION Our case series suggests non-invasive home LI monitoring with EGM to be a reliable and potentially useful tool for the early detection of congestion or dehydration and thus for the further successful stabilization of a HF patient after a worsening episode.展开更多
Despite an increasing popularity of home blood pressure monitoring (HBPM) over the last few decades, little is known about HBPM use among hypertensive patients in the rural areas. A cross-sectional survey including 31...Despite an increasing popularity of home blood pressure monitoring (HBPM) over the last few decades, little is known about HBPM use among hypertensive patients in the rural areas. A cross-sectional survey including 318 hypertensive patients was conducted in a rural community in Beijing, China, in 2012. Participants were mainly recruited from a community health clinic and completed the questionnaires assessing HBPM usage. Binary logistic regression models were used for the analysis of medication adherence with age, gender, level of education marital status, perceived health status, duration of hypertension, HBPM use, and frequency of performing BP measurement. Among the total population, 78 (24.5%) reported currently use of HBPM. Only 5.1% of the HBPM users cited doctor’s advice as the reason for using HBPM. Analysis of the risk factors of poor medication adherence by multivariable modeling indicated significant associations between the duration of hypertension (adjusted OR, 3.31;95% CI, 1.91-5.72;P 01), frequency of performing BP measurements (adjusted OR, 2.33;95% CI, 1.42-3.83;展开更多
Smart Thermometer Technology is intended for early detection and objective monitoring of more than 100 diseases (inflammatory, vascular and tumor) by measuring the temperature of the area of interest on human skin sur...Smart Thermometer Technology is intended for early detection and objective monitoring of more than 100 diseases (inflammatory, vascular and tumor) by measuring the temperature of the area of interest on human skin surface. The technology includes fast-operating infrared sensors that can be connected by wireless communication to mobile devices, available to a user (smart phones, tabs, etc.) with built-in specialized thermography software. It measures the temperature of any areas of human skin surface via infrared sensor point by point, generates thermogram and automatically gives comprehensive to an average person report about the state of the examined area and dynamics of the pathological process after each monitoring session. Self-examination of one anatomical area takes no more than 1 minute. Smart Thermometer Technology allows us to increase the accuracy of monitoring of a disease, and in most cases without participation of a doctor, simplify and cheapen obtaining of information on the course of a pathologic process and obtaining of the conclusion on the effectiveness of treatment.展开更多
Objective:Home blood pressure monitoring(HBPM)is viewed as a facilitating factor in the initial diagnosis and long-term management of treated hypertension.However,evidence remains scarce about the effectiveness of HBP...Objective:Home blood pressure monitoring(HBPM)is viewed as a facilitating factor in the initial diagnosis and long-term management of treated hypertension.However,evidence remains scarce about the effectiveness of HBPM use in the real world.This study aimed to examine the associations of HBPM use with blood pressure(BP)control and medication adherence.Methods:This prospective cohort study included hypertensive patients with high cardiovascular risk who were aged≥50 years.At baseline,information about types of BP monitor,frequency of HBPM,perception of anti-hypertensive treatment,and measured office BP were collected.During the 1-year follow-up(visits at 1,2,3,6,and 12 months),information on medication adherence was collected at each visit.The 2 major outcomes were BP control at baseline and medication adherence during the 1-year follow-up.A log-binomial regression model was used to examine the association between frequency of HBPM and outcomes,stratified by the perceptions of anti-hypertensive treatment.Results:A total of 5,363 hypertensive patients were included in the analysis.The age was(64.6±7.2)years,and 41.2%(2,208)were female.Of the total patients,85.9%(4,606)had a home BP monitor and 47.8%(2,564)had an incorrect perception of anti-hypertensive treatment.Overall,24.2%(1,299)of patients monitored their BP daily,37.6%(2,015)weekly,17.3%(926)monthly,and 20.9%(1,123)less than monthly.At baseline,the systolic BP and diastolic BP were(146.6±10.8)mmHg and(81.9±10.6)mmHg,respectively,and 28.5%(1,527)of patients had their BP controlled.Regardless of whether the patients had correct or incorrect perceptions of anti-hypertensive treatment,there is no significant association between HBPM frequency and BP control at baseline.During the 1-year follow-up,23.9%(1,280)of patients had non-adherence to medications at least once.In patients with an incorrect perception of anti-hypertensive treatment,those monitoring BP most frequently(daily)had the highest non-adherence rate(29.9%,175/585).Compared with those monitoring their BP less than monthly,patients who monitored their BP daily were more likely not to adhere to anti-hypertensive medications(adjusted relative risk=1.38,95%confidence interval:1.11–1.72,P=0.004).Conclusions:HBPM performance among hypertensive patients in China is,in general,sub-optimal.No association was observed between using HBPM alone and hypertension control,indicating that the effects of HBPM could be conditional.Patients’misconceptions about anti-hypertensive treatment may impair the role of BP monitoring in achieving medication adherence.Fully incorporating the correct perception of hypertension into the management of hypertensive patients is needed.展开更多
文摘AIM: To evaluate intraocular pressure(IOP) measurements and fluctuations using the i Care ONE rebound tonometer(RT-ONE), during home monitoring, in diagnosed and suspected glaucoma patients.METHODS: A retrospective case series of consecutive patients with known glaucoma or glaucoma suspects who were followed-up and treated between January 2016 and January 2017. The study included 80 eyes of 40 patients with a mean age of 59.1±14.6 y(range, 24-78). All patients have undergone 4-5 d of IOP home monitoring with RT-ONE at morning, noon, afternoon, and night time.RESULTS: Baseline mean IOP, as measured in the clinic(8 a.m.-12 p.m.), was 17.4±5.1 mm Hg, compared to RT-ONE home monitoring mean IOP of 15.6±4.1 mm Hg(P=0.002). Mean IOP was significantly lower at noon, afternoon and night times compared to clinic measured IOP and morning measurements(P=0.005). IOP peak measured during home monitoring was significantly higher compared to the clinic measured IOP(21.3±5.6 mm Hg and 17.4±5.1 mm Hg, P<0.001). IOP peaks during home monitoring demonstrated a majority of 47 peaks during morning measurements, compared to 23 at noon, 19 at afternoon and only 12 at night(P<0.001). The home monitoring results led to treatment modification of 44 eyes(55%), treatment regime was insufficient for 40(50%) eyes.CONCLUSION: Home monitoring IOP with RT-ONE can provide good assessment of mean IOP, IOP fluctuations and peaks throughout the hours of the day, which lead to an accurate treatment for glaucoma patients.
文摘Background The impact of home monitoring system in the early detection of ventricular arrhythmia and inappropriate shock in daily work is not clear. The aim of this study was to investigate the impact of home monitoring system on the early detection of ventricular arrhythmia and inappropriate shock in daily clinical practice. Methods Cases of implantable cardioverter defibrillator (ICD) implantation with or without the home monitoring system from June 2010 to October 2011 at our center were reviewed. Follow-up was scheduled after implantation. Data relating to the home monitoring ICD were retrieved using a remote transmitter system. Data relating to the other devices were obtained during scheduled follow-up or unscheduled visits. Results Our study involved 69 patients (mean age (68.4+17.6) years, 64.3% males, 26 in the home monitoring group vs. 43 in the non-home monitoring group). In all, 561 ventricular arrhythmia episodes were detected in 17 patients (39.5%) in the non-home monitoring group: 495 episodes were ventricular tachycardia and 66 episodes were ventricular fibrillation; among these, 476 episodes of ventricular tachycardia and 45 episodes of ventricular fibrillation were appropriately diagnosed (96.1% and 68.2%, respectively). In the home monitoring group, 389 ventricular arrhythmia episodes were transmitted by the home monitoring system in nine patients (34.6%): 348 ventricular tachycardia episodes and 41 ventricular fibrillation episodes. Device detection was appropriate in 348 ventricular tachycardia episodes (100.0%) and 36 ventricular fibrillation episodes (87.8%). The home monitoring group showed a higher appropriate detection rate of ventricular tachycardia (P 〈0.01) and ventricular fibrillation (P=0.02). The proportion of inappropriate shock was comparable in the two groups (6/11 in the non-home monitoring group vs. 1/7 in the home monitoring group; m=0.08). Conclusions The home monitoring ICD was able to provide information relating to inappropriate detection and shock earlier than conventional devices. It proved to be a reliable tool and has a strong potential to provide greater reaction time in the case of inappropriate shock.
文摘AIM:To identify a possible role of home echocardiography for monitoring chronic heart failure(CHF)patients.METHODS:We prospectively investigated 118 patients hospitalized during the last year for CHF who could not easily reach the pertaining District Healthcare Center.The patients were followed up with 2 home management programs:one including clinical and electrocardiographic evaluations and also periodic home echocardiographic examinations(group A),the other including clinical and electrocardiographic evaluations only(group B).RESULTS:At the end of the 18-mo follow-up no significant differences were observed between the 2 groups as regards the primary endpoint:rehospitalization occurred in 4 patients of the group A and in 6 patients of the group B;major cardiovascular events occurred in 2 and in 3 patients,respectively.No significant differences were observed with respect to the secondary endpoints:one vascular event appeared in both the groups,3 cardiovascular deaths occurred in group A and 2 in group B.No significant differences were observed between the 2 groups as regards the composite endpoint of death plus hospitalization.CONCLUSION:Home echocardiography for monitoring of CHF patients does not improve the cardiovascular endpoints.In our CHF patients,a low incidence of vascular events was observed.
基金Supported by the NordForsk "Nordic Programme on Health and Welfare",No.76015
文摘BACKGROUND Patients discharged after hospitalization for acute heart failure(AHF) are frequently readmitted due to an incomplete decongestion, which is difficult to assess clinically. Recently, it has been shown that the use of a highly sensitive,non-invasive device measuring lung impedance(LI) reduces hospitalizations for heart failure(HF); it has also been shown that this device reduces the cardiovascular and all-cause mortality of stable HF patients when used in longterm out-patient follow-ups. The aim of these case series is to demonstrate the potential additive role of non-invasive home LI monitoring in the early postdischarge period.CASE SUMMARY We present a case series of three patients who had performed daily LI measurements at home using the edema guard monitor(EGM) during 30 d after an episode of AHF. All patients had a history of chronic ischemic HF with a reduced ejection fraction and were hospitalized for 6–17 d. LI measurements were successfully made at home by patients with the help of their caregivers. The patients were carefully followed up by HF specialists who reacted to the values of LI measurements, blood pressure, heart rate and clinical symptoms. LI reduction was a more frequent trigger to medication adjustments compared to changes in symptoms or vital signs. Besides, LI dynamics closely tracked the use and dose of diuretics.CONCLUSION Our case series suggests non-invasive home LI monitoring with EGM to be a reliable and potentially useful tool for the early detection of congestion or dehydration and thus for the further successful stabilization of a HF patient after a worsening episode.
文摘Despite an increasing popularity of home blood pressure monitoring (HBPM) over the last few decades, little is known about HBPM use among hypertensive patients in the rural areas. A cross-sectional survey including 318 hypertensive patients was conducted in a rural community in Beijing, China, in 2012. Participants were mainly recruited from a community health clinic and completed the questionnaires assessing HBPM usage. Binary logistic regression models were used for the analysis of medication adherence with age, gender, level of education marital status, perceived health status, duration of hypertension, HBPM use, and frequency of performing BP measurement. Among the total population, 78 (24.5%) reported currently use of HBPM. Only 5.1% of the HBPM users cited doctor’s advice as the reason for using HBPM. Analysis of the risk factors of poor medication adherence by multivariable modeling indicated significant associations between the duration of hypertension (adjusted OR, 3.31;95% CI, 1.91-5.72;P 01), frequency of performing BP measurements (adjusted OR, 2.33;95% CI, 1.42-3.83;
文摘Smart Thermometer Technology is intended for early detection and objective monitoring of more than 100 diseases (inflammatory, vascular and tumor) by measuring the temperature of the area of interest on human skin surface. The technology includes fast-operating infrared sensors that can be connected by wireless communication to mobile devices, available to a user (smart phones, tabs, etc.) with built-in specialized thermography software. It measures the temperature of any areas of human skin surface via infrared sensor point by point, generates thermogram and automatically gives comprehensive to an average person report about the state of the examined area and dynamics of the pathological process after each monitoring session. Self-examination of one anatomical area takes no more than 1 minute. Smart Thermometer Technology allows us to increase the accuracy of monitoring of a disease, and in most cases without participation of a doctor, simplify and cheapen obtaining of information on the course of a pathologic process and obtaining of the conclusion on the effectiveness of treatment.
基金supported by the National Key Research and Development Program of China(2018YFC1312404,2018YFC1312400)by the National Clinical Research Center for Cardiovascular Diseases,Fuwai Hospital,Chinese Academy of Medical Sciences(NCRC2021001).
文摘Objective:Home blood pressure monitoring(HBPM)is viewed as a facilitating factor in the initial diagnosis and long-term management of treated hypertension.However,evidence remains scarce about the effectiveness of HBPM use in the real world.This study aimed to examine the associations of HBPM use with blood pressure(BP)control and medication adherence.Methods:This prospective cohort study included hypertensive patients with high cardiovascular risk who were aged≥50 years.At baseline,information about types of BP monitor,frequency of HBPM,perception of anti-hypertensive treatment,and measured office BP were collected.During the 1-year follow-up(visits at 1,2,3,6,and 12 months),information on medication adherence was collected at each visit.The 2 major outcomes were BP control at baseline and medication adherence during the 1-year follow-up.A log-binomial regression model was used to examine the association between frequency of HBPM and outcomes,stratified by the perceptions of anti-hypertensive treatment.Results:A total of 5,363 hypertensive patients were included in the analysis.The age was(64.6±7.2)years,and 41.2%(2,208)were female.Of the total patients,85.9%(4,606)had a home BP monitor and 47.8%(2,564)had an incorrect perception of anti-hypertensive treatment.Overall,24.2%(1,299)of patients monitored their BP daily,37.6%(2,015)weekly,17.3%(926)monthly,and 20.9%(1,123)less than monthly.At baseline,the systolic BP and diastolic BP were(146.6±10.8)mmHg and(81.9±10.6)mmHg,respectively,and 28.5%(1,527)of patients had their BP controlled.Regardless of whether the patients had correct or incorrect perceptions of anti-hypertensive treatment,there is no significant association between HBPM frequency and BP control at baseline.During the 1-year follow-up,23.9%(1,280)of patients had non-adherence to medications at least once.In patients with an incorrect perception of anti-hypertensive treatment,those monitoring BP most frequently(daily)had the highest non-adherence rate(29.9%,175/585).Compared with those monitoring their BP less than monthly,patients who monitored their BP daily were more likely not to adhere to anti-hypertensive medications(adjusted relative risk=1.38,95%confidence interval:1.11–1.72,P=0.004).Conclusions:HBPM performance among hypertensive patients in China is,in general,sub-optimal.No association was observed between using HBPM alone and hypertension control,indicating that the effects of HBPM could be conditional.Patients’misconceptions about anti-hypertensive treatment may impair the role of BP monitoring in achieving medication adherence.Fully incorporating the correct perception of hypertension into the management of hypertensive patients is needed.