期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Clinical Observation of the Hot and Humid Compress Therapy of Traditional Chinese Medicine in the Treatment of Qi Stagnation and Blood Stasis Type of Lumbar Disc Herniation
1
作者 Hailin Song Kui Xu +3 位作者 Hong Zhu Zengwu Xu Peng Li Runkai Wang 《Open Journal of Orthopedics》 2024年第7期312-324,共13页
Background: Although a number of studies have reported that the hot and humid compress from traditional Chinese medicine (TCM) is effective in treating lumbar disc herniation (LDH) with qi stagnation and blood stasis,... Background: Although a number of studies have reported that the hot and humid compress from traditional Chinese medicine (TCM) is effective in treating lumbar disc herniation (LDH) with qi stagnation and blood stasis, clinical evidence is limited. Objective: The purpose of this study is to provide high-quality evidence to support the effectiveness of the traditional Chinese hot and humid compress in the treatment of LDH with qi stagnation and blood stasis. Methods: From October 2021 to November 2023, 86 patients with LDH of qi stagnation and blood stasis type were recruited in our hospital and divided into a control (n = 43) and an observation group (n = 43) according to the random number table method. The control group was given routine clinical treatment, and the observation group was treated with the hot and humid compress therapy for two weeks. The visual analogue scale (VAS) score, Japanese Orthopaedic Association (JOA) score, TCM syndrome score, serum interleukin-6 (IL-6), serum interleukin-1β (IL-1β), and tumor necrosis factor-α (TNF-α) were observed and compared between the two groups before and after treatment, and the clinical efficacy of the two groups was evaluated. Results: After treatment, the VAS score, TCM symptom score, and serum IL-6, IL-1β, and TNF-α levels decreased in both groups (P P P P P Conclusions: The hot and humid compress of traditional Chinese medicine can effectively relieve pain, restore lumbar function, improve TCM syndromes, reduce the level of inflammatory factors, and have a curative effect in treating LDH. 展开更多
关键词 Chinese Medicine hot and humid Compress Lumbar Disc Herniation Qi Stagnation and Blood Stasis Type TCM Symptom Score Clinical Efficacy
下载PDF
Quantitative Analysis of the Outdoor Thermal Comfort in the Hot and Humid Summertime of Shenzhen, China 被引量:3
2
作者 Lin Liu Yaoyu Lin +1 位作者 Dan Wang Jing Liu 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2017年第2期30-38,共9页
Outdoor thermal comfort has always been a major issue due to its irreplaceable role in maintaining good health and energy use. Thus,quantitative analysis of outdoor thermal comfort and discussions on influential facto... Outdoor thermal comfort has always been a major issue due to its irreplaceable role in maintaining good health and energy use. Thus,quantitative analysis of outdoor thermal comfort and discussions on influential factors seem very necessary to achieve the climate-conscious urban design. Therefore,an outdoor thermal comfort questionnaire survey and the simultaneous field measurement were conducted in six different places during the hot and humid summertime in Shenzhen. The results show that the overall weather conditions during the investigation can be expressed with high temperature and high humidity with strong solar radiation. The micro-meteorological parameters of six test sites vary greatly due to their different regional spatial layouts.Moderate range of air temperature( Ta) is between 28 to 30 ℃ while that of relative humidity( RH) mainly concentrates in 60%-70% with the thermal sensation votes. The main influential factors impacting outdoor thermal comfort are obtained and Tahas the greatest effect. The overall thermal comfortable ranges in Shenzhen are expressed by the range of 28. 14-32. 83 ℃ of PET and 24. 74-30. 45 ℃ of SET*. With the correlation analysis between the characteristic parameters of regional spatial layout and thermal climate and thermal comfort,it reveals that increasing the coverage ratio of water and green space( S) helps lower Taand increase RH. The global solar radiation( G) has a significant negative correlation with the height of buildings( H) and a positive correlation with sky view factor( SVF). Overall,reasonable configuration of the regional spatial layout contributes to providing a thermal comfortable environment. 展开更多
关键词 outdoor thermal comfort micro-meteorology hot and humid climate field survey influential factors regional spatial layout
下载PDF
Optimisation of the double skin facade in hot and humid climates through altering the design parameter combinations 被引量:4
3
作者 Meng Wang Jingxin Hou +2 位作者 Zhongting Hu Wei He Hancheng Yu 《Building Simulation》 SCIE EI CSCD 2021年第3期511-521,共11页
Architects welcome double skin facade(DSF)due to its aesthetic quality.The first DSF structure was intended to prevent cold weather and strong winds.Nowadays,the application of DSF under different climates has been in... Architects welcome double skin facade(DSF)due to its aesthetic quality.The first DSF structure was intended to prevent cold weather and strong winds.Nowadays,the application of DSF under different climates has been investigated in many previous studies.Fiowever,little work had been done on the behaviour of DSF in hot and humid climates.Therefore,this paper aimed to extend the application into this specific climate and Guangzhou was selected as the sample city.Both the climate and the design influence the performance of DSF.In this paper,rather than explore how each design parameter influences the performance,the design was evaluated from an overall aspect.The Designbuilder software was used to build the single skin facade(SSF)and double skin facade base model.Annual HVAC energy consumption for both the two models was calculated and compared.An optimisation process was conducted to figure out what kinds of parameter combination could make the design more energy-saving and thermally comfortable.The results indicated that it was possible to design an energy-saving DSF system applied in hot and humid climates compared with the SSF model.The efficiency of the DSF could be further enhanced with a better parameter combination.The optimised options had some features in common,which could provide some inspirations for the application of DSF in hot and humid climates. 展开更多
关键词 double skin facade(DSF) hot and humid climate tall buildings building simulation optimisation design
原文传递
Effects of water-cooled cover on physiological and production parameters of farrowing sows under hot and humid climates 被引量:2
4
作者 Pang Zhenzhen Li Baoming +2 位作者 Zheng Weichao Lin Baozhong Liu Zuohua 《International Journal of Agricultural and Biological Engineering》 SCIE EI CAS 2016年第4期178-184,共7页
The hot and humid climates,as encountered in the southern region of China with the open housing,can adversely impact the sows undergoing heat stress during the most vulnerable period at lactation.Hence,a water-cooled ... The hot and humid climates,as encountered in the southern region of China with the open housing,can adversely impact the sows undergoing heat stress during the most vulnerable period at lactation.Hence,a water-cooled cover system(WCCs)for local cooling has essential practical value to improve productivity.The WCCs was developed for the sow crate of lactating sows separately,which performance was validated with the cooling efficiency in the sow occupied zone(SOZ)and physiological parameters.The results showed that the WCCs for the farrowing sows using aluminium plastic tubes connected in series could reach an appropriate cooling performance in adjacent units.The WCCs could decrease the SOZ air temperature by 3.0-4.5℃under the extremely hot climate when the indoor air temperature was 37℃,and maintain a suitable range(25-30℃)under the typical hot climate(<35℃).The respiration rate and skin temperature of farrowing sows had no significant difference between treatment group(WCC)and control group(sprinkle cooling)when the air temperature was below 30℃,but had a significant difference(p<0.05)when air temperature rose above 30℃.The control sows drank more during hot weather,and the feed intake was significantly lower than the sows with the WCCs(p<0.01).It was concluded that the WCCs could alleviate the heat stress of farrowing sows during typical hot climate. 展开更多
关键词 localized cooling heat stress farrowing sow water-cooled cover hot and humid climate
原文传递
Study on Prevention and Treatment of Autophagy and Cervical HPV Infection by Traditional Chinese Medicine Based on Pathogenesis of "Syndrome of Dampness-heat Diffusing Downward"
5
作者 Anqi Liu Mei Chen +4 位作者 Nan Li Hongli Zhu Jun Bai Xin Zhao Jiaxue Yang 《Journal of Clinical and Nursing Research》 2021年第3期9-11,共3页
Autophagy is a self-protection mechanism of the body,and also an important physiological process for cells to maintain internal environment stability.Studies have shown that the degree of autophagy damage is positivel... Autophagy is a self-protection mechanism of the body,and also an important physiological process for cells to maintain internal environment stability.Studies have shown that the degree of autophagy damage is positively correlated with the expression of oncogenes,and the expression of oncogenes is closely related to cervical HPV infection,so the control of autophagy ability can interfere with cervical HPV virus infection.Traditional Chinese medicine believes that dampness-heat evil down,can damage and Chong Ren cell.The author believes that autophagy damage and the theory of dampness-heat injection in cervical HPV infection have similar pathogenic mechanism,and explores the prevention and treatment of autophagy and cervical HPV infection based on the theory of traditional Chinese medicine dampness-heat injection,in attempt to provide a new treatment for clinical prevention and treatment. 展开更多
关键词 hot and humid betting AUTOPHAGY Cervical HPV infection
下载PDF
Effects of vernacular architecture structure on urban sustainability case study: Qeshm Island, Iran 被引量:2
6
作者 Hamed Mohammadi Mazraeh Mahdieh Pazhouhanfar 《Frontiers of Architectural Research》 CSCD 2018年第1期11-24,共14页
The architecture of Qeshm Island includes the specific architectural style of a warm and wet area, which previously had a functional use aimed to reach a sustainable architecture and development. However, few studies ... The architecture of Qeshm Island includes the specific architectural style of a warm and wet area, which previously had a functional use aimed to reach a sustainable architecture and development. However, few studies on the identification of the characteristics of vernacular architecture and their roles in island stability have been performed. Thus, to understand the vernacular architecture of the island as a sustainable pattern, we discussed it separately in three aspects, namely, urban fabric, one-based architecture, and architectural details. To address our study, a part of the old fabric of the city with its existing buildings (42 buildings of 70 years of age) was selected and evaluated in a qualitative study. Results showed that in the scale of the urban fabric, factors, such as the structures of the buildings, the frame of the neighborhood spaces, and in terms of the architectural details, factors, such as bars, thickness of the watts, and the openings, are among the vernacular features of the area, playing an important rote in the stability of Qeshm Island. In general, studies showed that vernacular architecture of the island has focused on developing an orientation between the climate of the region and a good understanding of the construction. 展开更多
关键词 Urban fabric Buitding form hot and humid cli-mate Traditionat architec-ture Wind catcher
原文传递
Cooling load characteristics of indoor spaces conditioned by decoupled radiant cooling unit with low radiant temperature
7
作者 Yuying Liang Nan Zhang +3 位作者 Huijun Wu Xinhua Xu Jianming Yang Gongsheng Huang 《Building Simulation》 SCIE EI CSCD 2022年第12期2067-2079,共13页
Decoupled radiant cooling units(DRCUs)are capable of increasing the cooling capacity without increasing condensation risks even using a much lower cooling temperature than conventional radiant cooling units(CRCUs).How... Decoupled radiant cooling units(DRCUs)are capable of increasing the cooling capacity without increasing condensation risks even using a much lower cooling temperature than conventional radiant cooling units(CRCUs).However,it is unclear whether DRCUs using low radiant cooling temperature will increase the cooling load of the conditioned indoor spaces.In this study,the cooling load characteristics of a thermal chamber conditioned by a DRCU was investigated through developing a steady-state analysis model suitable for both DRCUs and CRCUs.The total/radiative heat flux,as well as the heat exchange with a thermal manikin and walls were analysed under different surface temperatures of DRCUs.The effect of the emissivity of the thermal chamber’external wall on the cooling load was also investigated.Results indicated that the cooling load under the DRCU was slightly smaller than that under the CRCU when the same operative environment was created.Decreasing the infrared emissivity of the exterior wall’s inner surface could lead to a significant decrease in the cooling load for both the DRCU and CRCU.By decreasing the wall emissivity from 0.9 to 0.1,the total cooling load of the DRCU can be decreased by 8.4%and the heat gain of the exterior wall decreased by 21.6%.This study serves as a reference for developing the analysis model and understanding the load characteristics when DRCUs are used to create the thermal environment for indoor spaces. 展开更多
关键词 radiant cooling condensation-free computational fluid dynamics cooling load hot and humid climates
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部