Double-skin facades(DSF)are a technique developed for colder climates,so few people think about whether or not it can also be used for hot-summer and cold-winter zones in China.After analyzing the problems of using DS...Double-skin facades(DSF)are a technique developed for colder climates,so few people think about whether or not it can also be used for hot-summer and cold-winter zones in China.After analyzing the problems of using DSF for hot-summer zones,this paper explored on the possibility of applying DSF in hot-summer and cold-winter zones in China.The main existing research methods for DSF were also collected and commented.If properly managed,the ventilated DSF with controlled shading devices can be used even in hot summer in China.展开更多
In this paper, the suitability and construction technology of self-insulation walls were studied under the specific climatic conditions and regional resources of Hanzhong and Ankang in the hot summer and cold winter z...In this paper, the suitability and construction technology of self-insulation walls were studied under the specific climatic conditions and regional resources of Hanzhong and Ankang in the hot summer and cold winter zone of Southern Shaanxi. Through the calculation of heat transfer coefficient and thermal inertia index, combined with the specifications of the shale hollow brick and aerated concrete block of Hanzhong and Ankang in southern Shaanxi, the thermal performance and suitable thickness of the external wall using self-insulation materials that meet the Design Standard for Energy Efficiency of Residential Buildings(DBJ61-65-2011) in Shaanxi Province were obtained. The results showed that the self-insulation wall had technical suitability in the hot summer and cold winter zone. The research results provide not only a theoretical basis for the external wall insulation design of urban residential buildings in the hot summer and cold winter zone of southern Shaanxi, but also a reference for designers to carry out energy-saving design of external walls of residential buildings in other similar climate zones.展开更多
The energy efficiency design of the exterior wall in the buildings of the hot summer and cold winter zone of China should consider the heat prevention in summer and the heat insulation in winter. The self-insulation o...The energy efficiency design of the exterior wall in the buildings of the hot summer and cold winter zone of China should consider the heat prevention in summer and the heat insulation in winter. The self-insulation of the exterior?wall is a more feasible design to satisfy the energy efficiency of buildings in the?zone. However, the systematic research is urgently needed for the self-insulation of the exterior wall in the hot summer and cold winter zone of China. The paper tested the thermal performance of the common non-clay materials such as shale sintered hollow brick, sand autoclaved aerated concrete block, etc. by means of indoor experiments. The energy efficiency effect of the common materials was verified using dynamic calculation soft PKPM and several constitutions of exterior wall with different main bricks and insulation materials on the heat bridge were simulated, too. Besides, the tests of the thermal performance of exterior wall in real constructions were carried out to testify the practical effect of the recommended constitutions of exterior wall with different main bricks and insulation materials on the heat bridge. The conclusions are: the physical and thermal properties of the six non-clay wall material are better than the clay porous brick;the thermal performance of the non-clay brick can be improved obviously through the rational arrangement of the holes;shale sintered hollow brick after increasing the holes and rationalizing the hole arrangement and sand autoclaved aerated concrete block are recommended for buildings in the hot summer and cold winter area of China. The dynamic calculation results show that the thermal performances?of the non-clay materials are all satisfied with the energy efficiency;The heat transfer coefficient of the exterior wall with composition?③,?in which?the main wall was sand autoclaved aerated concrete block and the material on the heat bridge was sand autoclaved aerated concrete plate, is the smallest among the three recommended compositions.展开更多
This study monitors the open/closed states of the windows in 16 residential apartments in representative cities of the hot summer and cold winter zone of China,along with outdoor air temperature,outdoor relative humid...This study monitors the open/closed states of the windows in 16 residential apartments in representative cities of the hot summer and cold winter zone of China,along with outdoor air temperature,outdoor relative humidity and outdoor PM2.5 concentration in 2017,to investigate the window opening/closing behavior.Three window opening models are developed.All the models are validated by modeling a typical residential apartment to compare the predicted indoor CO_(2)concentration with monitored data.It is found that the window opening probability is negatively correlated to both outdoor PM2.5 concentration and outdoor relative humidity,and the probability of window opening reaches the peak value when the outdoor air temperature is 23.7℃.In terms of season,the shortest window opening duration occurs in winter due to the cold outdoor air temperature and high outdoor PM2.5 concentration.Finally,by comparing the correlation between the measured date and simulation results of indoor CO_(2)concentration,this study provides an appropriate window opening model for reference.展开更多
文摘Double-skin facades(DSF)are a technique developed for colder climates,so few people think about whether or not it can also be used for hot-summer and cold-winter zones in China.After analyzing the problems of using DSF for hot-summer zones,this paper explored on the possibility of applying DSF in hot-summer and cold-winter zones in China.The main existing research methods for DSF were also collected and commented.If properly managed,the ventilated DSF with controlled shading devices can be used even in hot summer in China.
文摘In this paper, the suitability and construction technology of self-insulation walls were studied under the specific climatic conditions and regional resources of Hanzhong and Ankang in the hot summer and cold winter zone of Southern Shaanxi. Through the calculation of heat transfer coefficient and thermal inertia index, combined with the specifications of the shale hollow brick and aerated concrete block of Hanzhong and Ankang in southern Shaanxi, the thermal performance and suitable thickness of the external wall using self-insulation materials that meet the Design Standard for Energy Efficiency of Residential Buildings(DBJ61-65-2011) in Shaanxi Province were obtained. The results showed that the self-insulation wall had technical suitability in the hot summer and cold winter zone. The research results provide not only a theoretical basis for the external wall insulation design of urban residential buildings in the hot summer and cold winter zone of southern Shaanxi, but also a reference for designers to carry out energy-saving design of external walls of residential buildings in other similar climate zones.
文摘The energy efficiency design of the exterior wall in the buildings of the hot summer and cold winter zone of China should consider the heat prevention in summer and the heat insulation in winter. The self-insulation of the exterior?wall is a more feasible design to satisfy the energy efficiency of buildings in the?zone. However, the systematic research is urgently needed for the self-insulation of the exterior wall in the hot summer and cold winter zone of China. The paper tested the thermal performance of the common non-clay materials such as shale sintered hollow brick, sand autoclaved aerated concrete block, etc. by means of indoor experiments. The energy efficiency effect of the common materials was verified using dynamic calculation soft PKPM and several constitutions of exterior wall with different main bricks and insulation materials on the heat bridge were simulated, too. Besides, the tests of the thermal performance of exterior wall in real constructions were carried out to testify the practical effect of the recommended constitutions of exterior wall with different main bricks and insulation materials on the heat bridge. The conclusions are: the physical and thermal properties of the six non-clay wall material are better than the clay porous brick;the thermal performance of the non-clay brick can be improved obviously through the rational arrangement of the holes;shale sintered hollow brick after increasing the holes and rationalizing the hole arrangement and sand autoclaved aerated concrete block are recommended for buildings in the hot summer and cold winter area of China. The dynamic calculation results show that the thermal performances?of the non-clay materials are all satisfied with the energy efficiency;The heat transfer coefficient of the exterior wall with composition?③,?in which?the main wall was sand autoclaved aerated concrete block and the material on the heat bridge was sand autoclaved aerated concrete plate, is the smallest among the three recommended compositions.
基金Part of the work is supported by National Science Foundation of China(51878408,51508326)the Key laboratory of healthy en-vironment and energy conservation for industrial large space building(2019SA-10-07)This work is supported by the national key project of the Ministry of Science and Technology,China,on“Green Buildings and Building Industrialization”through Grant No.2016YFC0700500.
文摘This study monitors the open/closed states of the windows in 16 residential apartments in representative cities of the hot summer and cold winter zone of China,along with outdoor air temperature,outdoor relative humidity and outdoor PM2.5 concentration in 2017,to investigate the window opening/closing behavior.Three window opening models are developed.All the models are validated by modeling a typical residential apartment to compare the predicted indoor CO_(2)concentration with monitored data.It is found that the window opening probability is negatively correlated to both outdoor PM2.5 concentration and outdoor relative humidity,and the probability of window opening reaches the peak value when the outdoor air temperature is 23.7℃.In terms of season,the shortest window opening duration occurs in winter due to the cold outdoor air temperature and high outdoor PM2.5 concentration.Finally,by comparing the correlation between the measured date and simulation results of indoor CO_(2)concentration,this study provides an appropriate window opening model for reference.