期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Ventilated Double Skin Facades in Hot-Summer and Cold-Winter Zones in China 被引量:1
1
作者 ZHOU Juan,CHEN You-ming,FANG Shan-shan(College of Civil Engineering,Hunan University,Changsha,Hunan 410082,China Key Laboratory of Building Safety and Energy Efficiency,MOE,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期160-162,共3页
Double-skin facades(DSF)are a technique developed for colder climates,so few people think about whether or not it can also be used for hot-summer and cold-winter zones in China.After analyzing the problems of using DS... Double-skin facades(DSF)are a technique developed for colder climates,so few people think about whether or not it can also be used for hot-summer and cold-winter zones in China.After analyzing the problems of using DSF for hot-summer zones,this paper explored on the possibility of applying DSF in hot-summer and cold-winter zones in China.The main existing research methods for DSF were also collected and commented.If properly managed,the ventilated DSF with controlled shading devices can be used even in hot summer in China. 展开更多
关键词 POSSIBILITY double-skin FACADES hot-summer and cold-winter ZONES simulation method
下载PDF
Indoor environment of nearly zero energy residential buildings with conventional air conditioning in hot-summer and cold-winter zone
2
作者 Jiankai Dong Haixia Lan +2 位作者 Yu Liu Xiaotao Wang Chenchen Yu 《Energy and Built Environment》 2022年第2期129-138,共10页
According to the few researches on Nearly zero energy residential buildings(NZERB)in hot-summer and cold-winter zone,although it could reduce the cooling load of buildings due to its high thermal insulation and air ti... According to the few researches on Nearly zero energy residential buildings(NZERB)in hot-summer and cold-winter zone,although it could reduce the cooling load of buildings due to its high thermal insulation and air tightness,it still needed for certain cooling in summer.This paper studied indoor environment of NZERB un-der three kinds of air-conditioners(split-type air-conditioner,multi-line air-conditioner and ceiling radiant air-conditioner).Firstly,a simulation model of NZERB was established based on Nanjing,a typical city in hot-summer and cold-winter zone.Secondly,variation of indoor air temperature and building load characteristics with outdoor air temperature were studied.Thirdly,indoor environment and energy consumption under three selected con-ventional air-conditioners in summer were simulated.Finally,the discussion was given,and an air-conditioner combining with convective and radiant cooling were proposed.The results indicated that the air-conditioner needed to be turned on in NZERB in hot-summer and cold-winter zone due to the room air temperature in off-air condition ranged from 32℃to 36℃,which was higher than designed indoor environment temperature in sum-mer,but the indoor environment of NZERB under three selected conventional air-conditioners could not meet the requirements of energy saving and comfort at the same time,and a proposed convective-radiant air-conditioner could be fast,stable,and energy saving.The findings can provide a reference for conducting active technology in NZERB. 展开更多
关键词 Nearly zero energy residential building Load characteristics Air-conditioners Indoor environment hot-summer and cold-winter zone
原文传递
上一页 1 下一页 到第