期刊文献+
共找到4,841篇文章
< 1 2 243 >
每页显示 20 50 100
Explosion damage effects of aviation kerosene storage tank under strong ignition
1
作者 Shixiang Song Cheng Wang +1 位作者 Boyang Qiao Gongtian Gu 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第7期27-38,共12页
In order to study the blast damage effects of aviation kerosene storage tanks,the out-field explosion experiments of 8 m3fixed-roof tanks were carried out.The fragments,shock wave and fireball thermal radiation of the... In order to study the blast damage effects of aviation kerosene storage tanks,the out-field explosion experiments of 8 m3fixed-roof tanks were carried out.The fragments,shock wave and fireball thermal radiation of the tank in the presence of bottom oil,half oil and full oil,as well as empty tank,were investigated under internal explosion by various TNT charge contents(1.8 kg,3.5 kg and 6.2 kg).The results showed that the tank roof was the only fragment produced,and the damage forms could be divided into three types.The increase of TNT charge content and oil volume enlarged the deformation of the tank,while the hole ratio presented a trend of increase first and then decrease.The H_r,maxand V_(max)values positively increased as increasing the TNT charge content and oil volume(from empty to half oil),but decreased in full oil.The Pmaxvalues had a progressive increase with the increment of TNT charge content,but not the case with the increase in oil volumes.The development of fireball was divided into three stages:tank roof‘towed'flame,jet flow flame tumbling and rising,and jet flow flame extinguishing.The Dmaxand Hf,maxvalues both increased as increasing TNT charge content and oil volumes.The oscillation phenomenon of fireball temperature was observed in the cooling process.The average temperature of fireball surface was positively correlated with TNT charge content,and negatively correlated with oil volumes. 展开更多
关键词 Aviation kerosene storage tank Internal explosion Shock wave FIREBALL
下载PDF
Numerical Simulation of the Seismic Response of a Horizontal Storage Tank Based on a SPH-FEM Coupling Method
2
作者 Peilei Yan Endong Guo +1 位作者 HouliWu Liangchao Zhang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第5期1655-1678,共24页
A coupled numerical calculation method combining smooth particle hydrodynamics(SPH)and the finite element method(FEM)was implemented to investigate the seismic response of horizontal storage tanks.Anumericalmodel of a... A coupled numerical calculation method combining smooth particle hydrodynamics(SPH)and the finite element method(FEM)was implemented to investigate the seismic response of horizontal storage tanks.Anumericalmodel of a horizontal storage tank featuring a free liquid surface under seismic action was constructed using the SPH–FEM coupling method.The stored liquid was discretized using SPH particles,while the tank and supports were discretized using the FEM.The interaction between the stored liquid and the tank was simulated by using the meshless particle contact method.Then,the numerical simulation results were compared and analyzed against seismic simulation shaking table test data to validate the method.Subsequently,a series of numerical models,considering different liquid storage volumes and seismic effects,were constructed to obtain time history data of base shear and top center displacement,which revealed the seismic performance of horizontal storage tanks.Numerical simulation results and experimental data showed good agreement,with an error rate of less than 18.85%.And this conformity signifies the rationality of the SPH-FEM coupling method.The base shear and top center displacement values obtained by the coupled SPH-FEM method were only 53.3% to 69.1% of those calculated by the equivalent mass method employed in the current code.As the stored liquid volume increased,the seismic response of the horizontal storage tank exhibited a gradual upward trend,with the seismic response increasing from 73% to 388% for every 35% increase in stored liquid volume.The maximum von Mises stress of the tank and the supports remained below the steel yield strength during the earthquake.The coupled SPH-FEM method holds certain advantages in studying the seismic problems of tanks with complex structural forms,particularly due to the representation of the flow field distribution during earthquakes by involving reservoir fluid participation. 展开更多
关键词 SPH-FEM coupling method horizontal storage tank seismic response SLOSHING
下载PDF
Modern Corrosion Mapping of Storage Tank Bottoms--Notable Advancements in Critical Zone Coverage,Inspection Efficiency and Data Integrity
3
作者 Andrew J.Simpson Matthew A.Boat 《Journal of Civil Engineering and Architecture》 2024年第3期148-153,共6页
Every day,an NDT(Non-Destructive Testing)report will govern key decisions and inform inspection strategies that could affect the flow of millions of dollars which ultimately affects local environments and potential ri... Every day,an NDT(Non-Destructive Testing)report will govern key decisions and inform inspection strategies that could affect the flow of millions of dollars which ultimately affects local environments and potential risk to life.There is a direct correlation between report quality and equipment capability.The more able the equipment is-in terms of efficient data gathering,signal to noise ratio,positioning,and coverage-the more actionable the report is.This results in optimal maintenance and repair strategies providing the report is clear and well presented.Furthermore,when considering tank floor storage inspection it is essential that asset owners have total confidence in inspection findings and the ensuing reports.Tank floor inspection equipment must not only be efficient and highly capable,but data sets should be traceable and integrity maintained throughout.Corrosion mapping of large surface areas such as storage tank bottoms is an inherently arduous and time-consuming process.MFL(magnetic flux leakage)based tank bottom scanners present a well-established and highly rated method for inspection.There are many benefits of using modern MFL technology to generate actionable reports.Chief among these includes efficiency of coverage while gaining valuable information regarding defect location,severity,surface origin and the extent of coverage.More recent advancements in modern MFL tank bottom scanners afford the ability to scan and record data sets at areas of the tank bottom which were previously classed as dead zones or areas not scanned due to physical restraints.An example of this includes scanning the CZ(critical zone)which is the area close to the annular to shell junction weld.Inclusion of these additional dead zones increases overall inspection coverage,quality and traceability.Inspection of the CZ areas allows engineers to quickly determine the integrity of arguably the most important area of the tank bottom.Herein we discuss notable developments in CZ coverage,inspection efficiency and data integrity that combines to deliver an actionable report.The asset owner can interrogate this report to develop pertinent and accurate maintenance and repair strategies. 展开更多
关键词 storage tank tank bottom CZ MFL stars CORROSION corrosion-mapping EFFICIENCY COVERAGE paperless reporting data traceability
下载PDF
Key technology and application of AB_(2) hydrogen storage alloy in fuel cell hydrogen supply system
4
作者 Ming Yao Jianguang Yuan +3 位作者 Bao Zhang Youhua Yan Shaoxiong Zhou Ying Wu 《Materials Reports(Energy)》 EI 2024年第1期113-122,共10页
At present,there is limited research on the application of fuel cell power generation system technology using solid hydrogen storage materials,especially in hydrogen-assisted two-wheelers.Considering the disadvantages... At present,there is limited research on the application of fuel cell power generation system technology using solid hydrogen storage materials,especially in hydrogen-assisted two-wheelers.Considering the disadvantages of low hydrogen storage capacity and poor kinetics of hydrogen storage materials,our primary focus is to achieve smooth hydrogen ab-/desorption over a wide temperature range to meet the requirements of fuel cells and their integrated power generation systems.In this paper,the Ti_(0.9)Zr_(0.1)Mn_(1.45)V_(0.4)Fe_(0.15) hydrogen storage alloy was successfully prepared by arc melting.The maximum hydrogen storage capacity reaches 1.89 wt% at 318 K.The alloy has the capability to absorb 90% of hydrogen storage capacity within 50 s at 7 MPa and release 90% of hydrogen within 220 s.Comsol Multiphysics 6.0 software was used to simulate the hydrogen ab-/desorption processes of the tank.The flow rate of cooling water during hydrogen absorption varied in a gradient of(0.02 t x)m s^(-1)(x=0,0.02,0.04,0.06,0.08,0.1,0.12).Cooling water flow rate is positively correlated with the hydrogen absorption rate but negatively correlated with the cost.When the cooling rate is 0.06 m s^(-1),both simulation and experimentation have shown that the hydrogen storage tank is capable of steady hydrogen desorption for over 6 h at a flow rate of 2 L min^(-1).Based on the above conclusions,we have successfully developed a hydrogen-assisted two-wheeler with a range of 80 km and achieved regional demonstration operations in Changzhou and Shaoguan.This paper highlights the achievements of our team in the technological development of fuel cell power generation systems using solid hydrogen storage materials as hydrogen storage carriers and their application in twowheelers in recent years. 展开更多
关键词 AB_(2)hydrogen storage alloy Hydrogen storage tanks Simulation Hydrogen-electric coupling system Power-assisted two-wheelers
下载PDF
Investigation of factors affecting on viscosity reduction of sludge from Iranian crude oil storage tanks 被引量:14
5
作者 Masoumeh Hassanzadeh Leila Tayebi Hedieh Dezfouli 《Petroleum Science》 SCIE CAS CSCD 2018年第3期634-643,共10页
Crude oil is a kind of water/oil emulsion, which the oil phase consists of organic molecules with different molecular weights such as alkanes, paraffin, asphaltene, and resins. Due to the change in physicochemical con... Crude oil is a kind of water/oil emulsion, which the oil phase consists of organic molecules with different molecular weights such as alkanes, paraffin, asphaltene, and resins. Due to the change in physicochemical conditions during the production, transportation, storage, and refining, heavier molecules can precipitate from crude oil. Thus, viscous sludge formed at the bottom of storage tanks can cause many problems including reduction of storage capacity of tank, oil contamination, corrosion, repair costs, environmental pollution, etc. The reduction of sludge viscosity can be achieved by reduction of its interfacial tension. In this study, different chemical and physical factors, influencing prepared emulsions(made of sludge, water and surfactant), such as surfactants, solvents, temperature, pressure, and mixing conditions were investigated. Results showed that non-ionic surfactants(like bitumen emulsifier), and solvents(such as mixed xylene, AW-400, and AW-402), injection of additives, applying pressure, and mixing operations had a positive effect on reduction of emulsion viscosity. All experiments were carried out with sludge obtained from crude oil storage tanks at Kharg Island,Iran. 展开更多
关键词 SURFACTANT EMULSION SLUDGE storage tank Crude oil
下载PDF
Seismic assessment of unanchored steel storage tanks by endurance time method 被引量:4
6
作者 M. Alembagheri H.E. Estekanchi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2011年第4期591-603,共13页
Liquid storage tanks are essential structures that are often located in residential and industrial areas; thus an assessment of their seismic performance is an important engineering issue. In this paper, the seismic r... Liquid storage tanks are essential structures that are often located in residential and industrial areas; thus an assessment of their seismic performance is an important engineering issue. In this paper, the seismic response ofunanchored steel liquid storage tanks is investigated using the endurance time (ET) dynamic analysis procedure and compared to responses obtained for anchored tanks under actual ground motions and intensifying ET records. In most cases, the results from ground motions are properly obtained with negligible differences using ET records. It is observed that uplifting of the tank base, which is closely related to the tank aspect ratio, has the greatest significance in the responses of the tank and can be predicted with reasonable accuracy by using currently available ET records. 展开更多
关键词 steel liquid storage tanks endurance time method seismic assessment intensifying dynamic excitation tank base uplifting
下载PDF
Operation Performance of Central Solar Heating System with Seasonal Storage Water Tank in Harbin 被引量:2
7
作者 YE Ling1,JIANG Yi-qiang1,YAO Yang1,ZHANG Shi-cong2(1.Institute of Heat Pump and Air Conditioning Technology,Harbin Institute of Technology,Harbin,Heilongjiang 150090,China 2.Institute of Built Environment and Energy Efficiency,China Academy of Building Research,Beijing 100013,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期111-114,共4页
This paper presented a preliminary research on the central solar heating system with seasonal storage(CSHSSS)used in cold climate in China.A mathematical model of the solar energy seasonal storage water tank used in t... This paper presented a preliminary research on the central solar heating system with seasonal storage(CSHSSS)used in cold climate in China.A mathematical model of the solar energy seasonal storage water tank used in the central solar heating system was firstly developed based on energy conservation.This was followed by the simulation of the CSHSSS used in a two-floor villa in Harbin,and analysis of the impacts on storage water temperature of tank volume,solar collector area,tank burial depth,insulation thickness around the tank,etc.The results show there is a relatively economical tank volume to optimize the system efficiency,which decreases with increasing tank volume at the constant collector area,and increases with increasing collector area at the constant tank volume.Furthermore,the insulation thickness has obvious effect on avoiding heat loss,while the tank burial depth doesn't.In addition,the relationship between the solar collector efficiency and storage water temperature is also obtained,it decreases quickly with increasing storing water temperature,and then increases slowly after starting space heating system.These may be helpful for relevant design and optimization in cold climates in China and all over the world. 展开更多
关键词 CENTRAL solar heating SYSTEM with SEASONAL storage(CSHSSS) simulation SYSTEM efficiency storage water tank VILLA
下载PDF
Optimization of Baffled Rectangular and Prismatic Storage Tank Against the Sloshing Phenomenon 被引量:7
8
作者 Hassan SAGHI NING De-zhi +1 位作者 CONG Pei-wen ZHAO Ming 《China Ocean Engineering》 SCIE EI CSCD 2020年第5期664-676,共13页
The fluid motion in partially filled tanks with internal baffles has wide engineering applications. The installation of baffles is expected to reduce the effect of sloshing as well as the consequent environmental dama... The fluid motion in partially filled tanks with internal baffles has wide engineering applications. The installation of baffles is expected to reduce the effect of sloshing as well as the consequent environmental damages. In the present study, a series of experimental tests are performed to investigate the sloshing phenomenon in a baffled rectangular storage tank. In addition, the sloshing phenomenon is also modeled by using Open Foam. Based on the experimental and numerical studies, optimization of the geometric parameters of the tank is performed based on some criteria such as tank area, entropy generation, and the horizontal force exerted on the tank area due to the sloshing phenomenon.The optimization is also carried out based on the entropy generation minimization analysis. It is noted that the optimum baffle height is in the range of h_b/h_w=0.5-0.75 in the present study(where h_b and h_w are the baffle height and water depth, respectively). Based on the results, the optimal design of the tank is achieved with R_A= 0.9-1.0(where R_A=L/W, L and W are the length and width of the tank, respectively). The results also show that the increase of h_b can lead to a decrease of the maximum pressure and horizontal force exerted on the tank. It is also noted that the horizontal force exerted on the tank firstly continues to increase as the sway motion amplitude increases.However, as the normalized motion amplitude parameter, a/L(The parameter a is the motion amplitude), exceeds0.067, the effect of motion amplitude on the force is not obvious. The same optimization is also performed in the multiple-variable-baffled tank and prismatic storage tank. 展开更多
关键词 baffled rectangular storage tank experimental tests sloshing phenomenon OPTIMIZATION entropy generation Open Foam
下载PDF
Numerical Simulation of Sloshing in Rectangular Storage Tank Using Coupled FEM-BEM 被引量:6
9
作者 Hassan Saghi Mohammad Javad Ketabdari 《Journal of Marine Science and Application》 2012年第4期417-426,共10页
Sloshing of liquid can increase the dynamic pressure on the storage sidewalls and bottom in tanker ships and LNG careers. Different geometric shapes were suggested for storage tank to minimize the sloshing pressure on... Sloshing of liquid can increase the dynamic pressure on the storage sidewalls and bottom in tanker ships and LNG careers. Different geometric shapes were suggested for storage tank to minimize the sloshing pressure on tank perimeter. In this research, a numerical code was developed to model liquid sloshing in a rectangular partially filled tank. Assuming the fluid to be inviscid, Laplace equation and nonlinear free surface boundary conditions are solved using coupled FEM-BEM. The code performance for sloshing modeling is validated against available data. To minimize the sloshing pressure on tank perimeter, rectangular tanks with specific volumes and different aspect ratios were investigated and the best aspect ratios were suggested. The results showed that the rectangular tank with suggested aspect ratios, not only has a maximum surrounded tank volume to the constant available volume, but also reduces the sloshing pressure efficiently. 展开更多
关键词 rectangular storage tank sloshing phenomenon aspect ratio coupled FEM-BEM
下载PDF
Improving the seismic performance of base-isolated liquid storage tanks with supplemental linear viscous dampers 被引量:6
10
作者 Alexandros Tsipianitis Yiannis Tsompanakis 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2022年第1期269-282,共14页
Large tanks are extensively used for storing water,petrochemicals and fuels.Since they are often cited in earthquake-prone areas,the safe and continuous operation of these important structures must be ensured even whe... Large tanks are extensively used for storing water,petrochemicals and fuels.Since they are often cited in earthquake-prone areas,the safe and continuous operation of these important structures must be ensured even when severe earthquakes occur,since their failure could have devastating financial and socio-environmental consequences.Base-isolation has been widely adopted for the efficient seismic protection of such critical facilities.However,base-isolated tanks can be located relatively close to active faults that generate strong excitations with special characteristics.Consequently,viscous dampers can be incorporated into the isolation system to reduce excessive displacement demands and to avoid overconservative isolator design.Nonetheless,only a few studies have focused on the investigation of seismic response of base-isolated liquid storage tanks in conjunction with supplemental viscous dampers.Therefore,the impact of the addition of supplemental linear viscous dampers on the seismic performance of tanks isolated by single friction pendulum devices is investigated herein.Four levels of supplemental damping are assessed and compared with respect to isolators′displacement capacity and accelerations that are transferred to the tanks. 展开更多
关键词 liquid storage tanks linear viscous dampers seismic isolation concave sliding bearings seismic vulnerability
下载PDF
Experimental Investigations of Various Methods of Sludge Measurements in Storage Oil Tanks 被引量:3
11
作者 Manuel Monteiro Victor Svet +1 位作者 Donald Sandilands Sergey Tsysar 《Advances in Remote Sensing》 2015年第2期119-137,共19页
This article describes the results of experimental studies into various methods of measuring sludge volume and its 3D spatial distribution using a base of data received from the inspection of more than 30 storage tank... This article describes the results of experimental studies into various methods of measuring sludge volume and its 3D spatial distribution using a base of data received from the inspection of more than 30 storage tanks of different types: external floating roof, internal floating roof and fixed roof. The advantages and disadvantages of making measurements with existing methods are discussed, including the problem of accuracy. Numerous examples of tank survey results are presented. 展开更多
关键词 storage tanks SLUDGE VOLUME of SLUDGE Acoustic BATHYMETRY THERMOGRAPHY
下载PDF
Seismic performance evaluation of VCFPB isolated storage tank using real-time hybrid simulation 被引量:3
12
作者 Hong Yue Tang Zhenyun +1 位作者 Li Zhenbao Du Xiuli 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2022年第2期501-515,共15页
Variable curvature friction pendulum bearings(VCFPB)effectively reduce the dynamic response of storage tanks induced by earthquakes.Shaking table testing is used to assess the seismic performance of VCFPB isolated sto... Variable curvature friction pendulum bearings(VCFPB)effectively reduce the dynamic response of storage tanks induced by earthquakes.Shaking table testing is used to assess the seismic performance of VCFPB isolated storage tanks.However,the vertical pressure and friction coefficient of the scaled VCFPB in the shaking table tests cannot match the equivalent values of these parameters in the prototype.To avoid this drawback,a real-time hybrid simulation(RTHS)test was developed.Using RTHS testing,a 1/8 scaled tank isolated by VCFPB was tested.The experimental results showed that the displacement dynamic magnification factor of VCFPB,peak reduction factors of the acceleration,shear force,and overturning moment at bottom of the tank,were negative exponential functions of the ratio of peak ground acceleration(PGA)and friction coefficient.The peak reduction factors of displacement,acceleration,force and overturning moment,which were obtained from the experimental results,are compared with those calculated by the Housner model.It can be concluded that the Housner model is applicable in estimation of the acceleration,shear force,and overturning moment of liquid storage tank,but not for the sliding displacement of VCFPBs. 展开更多
关键词 liquid storage tank base isolation variable curvature friction pendulum bearing seismic performance real-time hybrid simulation test
下载PDF
The Features of Acoustic Bathymetry of Sludge in Oil Storage Tanks 被引量:2
13
作者 Manel Monteiro Victor Svet Donald Sandilands 《Open Journal of Acoustics》 2014年第2期39-54,共16页
The features of acoustic bathymetry of sludge in crude oil tanks are considered. Different parameters of crude oil and sludge which are important for the selection of acoustic parameters such as sound speed, the acous... The features of acoustic bathymetry of sludge in crude oil tanks are considered. Different parameters of crude oil and sludge which are important for the selection of acoustic parameters such as sound speed, the acoustic impedances of “oil-sludge” boundaries and sound attenuation are analyzed and compared with experimental data. The main sources of errors of sludge volume estimation are discussed. 展开更多
关键词 CRUDE OIL storage OIL tanks SLUDGE ACOUSTIC BATHYMETRY ACOUSTIC PROFILING
下载PDF
Attenuating water hammer pressure by means of gas storage tank 被引量:1
14
作者 韩文亮 韩军 +2 位作者 方红卫 邹伟生 夏建新 《中国有色金属学会会刊:英文版》 CSCD 2001年第3期438-443,共6页
The basic equations for computing the volume of gas storage tank were derived from the principles of attenuating water hammer pressure. Verifications using experiments indicate that the proposed equation can provide a... The basic equations for computing the volume of gas storage tank were derived from the principles of attenuating water hammer pressure. Verifications using experiments indicate that the proposed equation can provide a fare precision in the predictions. By using the model of solid liquid two phase flow, the gas storage tank, pressure relief valves and slow closure reverse control valves were compared with practical engineering problems, and the functions of gas storage tank in attenuating water hammer pressure were further investigated. [ 展开更多
关键词 water hammer pressure protective equipment gas storage tank water hammer model
下载PDF
Non-destructive Testing Robots (NDTBOTs) for In-Service Storage Tank Inspection 被引量:1
15
作者 Richard Anvo Tariq P. Sattar +1 位作者 Tat-Hean Gan Ivan Pinson 《Journal of Mechanics Engineering and Automation》 2018年第3期103-109,共7页
Petrochemical storage tanks are generally inspected when the tank is offline mostly to assess the extent of underside corrosion on the tank floor. Emptying, cleaning and opening a tank for inspection take many months ... Petrochemical storage tanks are generally inspected when the tank is offline mostly to assess the extent of underside corrosion on the tank floor. Emptying, cleaning and opening a tank for inspection take many months and are very expensive. Inspection costs can be reduced significantly by inserting robots through manholes on the tank roof to pertbrm non-destructive testing (NDT). The challenge is to develop robots that can operate safely in explosive and hazardous environments and measure the thickness of floor plates using ultrasound sensors. This paper reports on the development of a small and inexpensive prototype robot (NDTBOT) which is designed to be intrinsically safe for zone zero operation. The robot "hops" across the floor to make measurements, without any external moving parts. The paper describes the design, experimental testing of the NDTBOT and presents results of steel plate thickness measurements made under water. 展开更多
关键词 storage tank inspection NDTBOT in-service inspection.
下载PDF
UNITIVE ANALYSIS SCHEMES ON PROBLEMS OF MULTIPLE MOVING BOUNDARIES WITH 3-D LIQUID-SOLID MULTIPLE NONLINEAR COUPLING FOR UPLIFT OF ANCHOREDLIQUID STORAGE TANKS
16
作者 温德超 郑兆昌 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 1997年第1期69-79,共11页
In the paper, 3-D analysis method with unitive schemes is set up, which is used to resolve the uplift with multiple moving boundaries and multiple nonlinear coupling for anchored liquid storage tanks. hi it, an algori... In the paper, 3-D analysis method with unitive schemes is set up, which is used to resolve the uplift with multiple moving boundaries and multiple nonlinear coupling for anchored liquid storage tanks. hi it, an algorithm of quasi-harmonious finite elements for arbitrary quadrilateral of thin plates and shells is built up to analyze the multiple coupling problems of general thin plates and shells structures with three dimensions, the complementary equations for analyzing uplifting moving boundary problems are deduced. The axial symmetry and presumption of beam type mode are not used. In it, an algorithm is put forward for analyzing the Navier-Stokes problems of unsteady, three-dimensional, and viscous liquid with sloshing of moving boundary surfaces in large amplitude under ALE frame by scheme of time-split-steps to which linear potential theory is not applied. The algorithms can be used to analyze the solid-liquid multiple nonlinear coupling problems with 3-D moving boundary with friction in multiple places. 展开更多
关键词 solid-liquid coupling multiple nonlinear coupling moving boundary liquid storage tank UPLIFT time-split-steps ALE method
下载PDF
Numerical Investigation of Effective Heat Conductivity of Fluid in Charging Process of Thermal Storage Tank
17
作者 Hadi Taheri Ferdinand P. Schmidt Martin Gabi 《Open Journal of Fluid Dynamics》 2015年第1期39-50,共12页
This paper presents a numerical case study of heat transfer mechanisms during the charging process of a stratified thermal storage tank applied in a specific adsorption heat pump cycle. The effective thermal conductiv... This paper presents a numerical case study of heat transfer mechanisms during the charging process of a stratified thermal storage tank applied in a specific adsorption heat pump cycle. The effective thermal conductivity of the heat transfer fluid during the charging process is analyzed through CFD simulations using Unsteady Reynolds-averaged Navier-Stokes equations (URANS). The aim of the study is to provide an equivalent thermal conductivity for a one-dimensional storage tank model to be used in a system simulation of the complete adsorption heat pump cycle. The influence of the turbulent mixing and also the advection effect due to fluid bulk motion are investigated. The results show that in the case considered here, the turbulence effect on the effective thermal conductivity is more considerable than the advection effect. 展开更多
关键词 THERMAL storage tank STRATIFICATION Pipe EFFECTIVE THERMAL Conductivity
下载PDF
Performing Reliable Early Leak Detection on Storage Tank Terminals:Retrofitting of Existing Facilities and New Buildings
18
作者 Raul Risi 《材料科学与工程(中英文B版)》 2018年第5期188-194,共7页
Liquid leak detection may represent a challenge for Oil&Gas operators,as indicated by operational feed-back and independent studies.Despite the availability of many different leak detection technologies,some syste... Liquid leak detection may represent a challenge for Oil&Gas operators,as indicated by operational feed-back and independent studies.Despite the availability of many different leak detection technologies,some systems may either fail to detect spills or generate frequent false alarms.In particular,possible soil contamination from pre-existing leaks and pollution carry-over by rain water is difficult to filter out by a leak sensing system.Typical case of false alarms relates to punctual sensors installed upstream the drain valve within the storage tank bunds,monitoring possible presence of leaks in rain water.Besides old soil contamination,other criteria should also be considered when selecting a spill detection technology,such as asset type to be monitored(storage tank,pipeline,…),system accuracy(minimum detectable quantity,ability to localize the leak),detection time,reliability over time,capital,installation and operating costs.The paper will include an evaluation of different external leak detection technologies with respect to the above-mentioned criteria,pointing out the capabilities and limitations of each system.Focus will be placed on reliability of leak monitoring systems in challenging environments.A new generation of digital,reusable sensing cables and probes,as well as the impact of sensitivity for different applications,will be discussed.Since leak sensor installation environment(positioning,adoption of special precautions,…)may significantly affect the system performance,different above ground and underground configurations will be presented,both for new builds and existing facilities. 展开更多
关键词 Liquid LEAK detection ADDRESSABLE system storage tank PIPELINE
下载PDF
Survey on Storage of Water for Domestic Use in Underground Reinforced Concrete Tanks: The Case of Brazzaville (Republic of Congo)
19
作者 Narcisse Malanda Paul Louzolo-Kimbembe 《Open Journal of Civil Engineering》 2014年第1期13-22,共10页
The problem of water supply from the public distribution network still poses very serious problems in many cities in developing countries. Intermittent water supply pushes some households to build underground reinforc... The problem of water supply from the public distribution network still poses very serious problems in many cities in developing countries. Intermittent water supply pushes some households to build underground reinforced concrete tanks for water storage to cope with unwanted water breaks. This study that relies on the results of a survey of households in some areas of the city of Brazzaville (Republic of Congo) aims to verify the importance that users attach to the quality of the works constructed. Indeed, the reliability of the tanks resulting in their impermeability to the external environment has a direct impact on the quality of stored water and therefore the use that is made of water daily. Five areas were selected because of their soil moisture. By 256 tanks identified, 143 are made of reinforced concrete and 113 in masonry. The coating materials used to seal the walls are preferably the earthenware tiles (64% of tanks), then the Sika cement (31%). Food painting (5%) is only rarely used. However, 66% of households are not assured of the potability of the water stored. A significant number of households (46%) think that the stored water could be contaminated with noxious substances seeping from the outside through the walls of the tanks. The issue of sealing of underground water tanks, especially in areas where the water table is shallow, seems concerned users. 展开更多
关键词 UNDERGROUND tanks Watertightness Reinforced Concrete WATER storage Potability Household
下载PDF
Cost Optimal Selection of Storage Tanks in LPG Vaporization Station
20
作者 Guohua Shi 《Natural Resources》 2012年第3期164-169,共6页
Liquefied petroleum gas (LPG) is an important urban gas source in China. Before supplied to customers by pipeline supply systems, LPG is stored in tanks in LPG vaporization stations. Designers usually decide the numbe... Liquefied petroleum gas (LPG) is an important urban gas source in China. Before supplied to customers by pipeline supply systems, LPG is stored in tanks in LPG vaporization stations. Designers usually decide the number and the size of storage tanks by their experience during constructions of vaporization stations. These decisions are usually not best and most economical. To solve the problem, a compact mixed integer nonlinear programming model has been developed in this paper. The objective is to minimize annual storage cost of the vaporization station. The model has been transformed into a general nonlinear programming model by transforming integer variables and 0-1 variables into continuous variables. One LPG vaporization station was taken as an example to illustrate the usage of the model. The results show that the optimal storage scheme can be determined accurately and quickly by the model and about 15% of storage cost can be saved every year after optimization. 展开更多
关键词 Liquefied Petroleum Gas storage tank COST Optimization Mixed INTEGER Nonlinear Programming
下载PDF
上一页 1 2 243 下一页 到第
使用帮助 返回顶部