After heat is metered in each house unit,the heating system is regulated by variable flow.The temperature of the return w ater is controlled to regulate the flow to realize the temperature regulation.According to the ...After heat is metered in each house unit,the heating system is regulated by variable flow.The temperature of the return w ater is controlled to regulate the flow to realize the temperature regulation.According to the characteristics of the temperature control w ith big inertia,pure time-delay and degeneration,a fuzzy adaptive PID controller is designed w ith the advantages of the fuzzy control and PID algorithm,and the simulation model is established according to the characteristics of heating metering system.Simulation results show that the fuzzy adaptive PID controller proposed has small overshoot,short oscillation cycle,high precision and strong anti-jamming capability in comparison w ith conventional PID controller,w hich could meet the requirement of the dynamic and steady-state performance of the heating process.展开更多
The design scheme for a new kind of long-distance intelligent watt-hour meter is presented. In the system, the control computer communicates with the bank's host computer by the X. 25 network; the built-in embeded se...The design scheme for a new kind of long-distance intelligent watt-hour meter is presented. In the system, the control computer communicates with the bank's host computer by the X. 25 network; the built-in embeded secure access module (ESAM) can verify data by commutation with the intelligent nodes that enhance the security of the data. IC TSS721 is adopted to collect data remotely, and the CPU IC card is used to ensure the the bargaining security and reliability. In addition, the software of the system is introduced.展开更多
There is an imperfection in the accuracy indicators system and the technical parameters system in IEC standards 62053-21 implemented for watt-hour meters currently. This article quoted some parts of OIML MI-003 and R4...There is an imperfection in the accuracy indicators system and the technical parameters system in IEC standards 62053-21 implemented for watt-hour meters currently. This article quoted some parts of OIML MI-003 and R46 contents to provide a reference of the integrity comparison between the accuracy system and technical parameter system. The comparison result shows that the watt-hour meter accuracy technical indicators system of OIML R46 is more integrated. First reason is that it determines all the accuracy (basic error) defining rules just by using the technical parameter I efficiently; secondly, it can solve the contradiction that no error regulation of the range from starting current to minimum current in the process of providing, handing over and checking watt-hour meter products' qualities efficiently. Please pay close attention to the R46 official version which will be released soon, as it is still in the Committee Draft (CD6) stage currently.展开更多
基金Project Supported by Education Department of Liaoning Province(LT2012005)
文摘After heat is metered in each house unit,the heating system is regulated by variable flow.The temperature of the return w ater is controlled to regulate the flow to realize the temperature regulation.According to the characteristics of the temperature control w ith big inertia,pure time-delay and degeneration,a fuzzy adaptive PID controller is designed w ith the advantages of the fuzzy control and PID algorithm,and the simulation model is established according to the characteristics of heating metering system.Simulation results show that the fuzzy adaptive PID controller proposed has small overshoot,short oscillation cycle,high precision and strong anti-jamming capability in comparison w ith conventional PID controller,w hich could meet the requirement of the dynamic and steady-state performance of the heating process.
文摘The design scheme for a new kind of long-distance intelligent watt-hour meter is presented. In the system, the control computer communicates with the bank's host computer by the X. 25 network; the built-in embeded secure access module (ESAM) can verify data by commutation with the intelligent nodes that enhance the security of the data. IC TSS721 is adopted to collect data remotely, and the CPU IC card is used to ensure the the bargaining security and reliability. In addition, the software of the system is introduced.
文摘There is an imperfection in the accuracy indicators system and the technical parameters system in IEC standards 62053-21 implemented for watt-hour meters currently. This article quoted some parts of OIML MI-003 and R46 contents to provide a reference of the integrity comparison between the accuracy system and technical parameter system. The comparison result shows that the watt-hour meter accuracy technical indicators system of OIML R46 is more integrated. First reason is that it determines all the accuracy (basic error) defining rules just by using the technical parameter I efficiently; secondly, it can solve the contradiction that no error regulation of the range from starting current to minimum current in the process of providing, handing over and checking watt-hour meter products' qualities efficiently. Please pay close attention to the R46 official version which will be released soon, as it is still in the Committee Draft (CD6) stage currently.