Currently, domestic and abroad scholars put more attention on contra-rotating dual-rotor axial fan. But there is less scholars study on asymmetric dual-rotor small axial fan, which is one of the contra-rotating dual-r...Currently, domestic and abroad scholars put more attention on contra-rotating dual-rotor axial fan. But there is less scholars study on asymmetric dual-rotor small axial fan, which is one of the contra-rotating dual-rotor axial fans. Like axial fan, many factors have influence on the performance of the asymmetric dual-rotor small axial flow fan, such as the wheel hub ratio, blade shape, blade number, stagger angle and the tip clearance. Because wheel hub ratio has great impact on the performance of the fan, we choose the size of wheel hub ratio as a variable factor to study the model change. There is a different wheel hub ratio between front stage impeller and rear stage of asymmetric dual-rotor small axial fan, so it is very beneficial to select the greater wind area that the fan area of external diameter minuses the area occupied by the blades and the hub as front stage impeller. In this paper, the hub-ratio of front stage impeller is 0.72, and that of rear stage is 0.72, 0.67 and 0.62 respectively along with the front stage impeller. Three kinds of models with different hub ratio of rear stage are simulated using the CFD software and the static characteristics are obtained. Based on the experimental test results, the internal flow field of the asymmetric dual-rotor small axial fan is analyzed in detail, the impact trends of different hub-ratio on the performance of asymmetric dual-rotor small axial fan are obtained and the argument of structure optimization for dual-rotor small axial fan is provided.展开更多
Under the condition that all the perfectly plastic stress components at a crack tip are the functions of ? only, making use of equilibrium equations and Von-Mises yield condition containing Poisson ratio, in this pape...Under the condition that all the perfectly plastic stress components at a crack tip are the functions of ? only, making use of equilibrium equations and Von-Mises yield condition containing Poisson ratio, in this paper, we derive the generally analytical expressions of perfectly plastic stress field at a stationary plane-strain crack tip. Applying these generally analytical expressions to the concrete cracks, the analytical expressions of perfectly plastic stress fields at the stationary tips of Mode I, Mode II and Mixed-Mode I-II plane-strain cracks are obtained. These analytical expressions contain Poisson ratio.展开更多
ObjectiveThe aim was to assess genetic and physiological toxicity of wastewater from a pharmaceutical factory using root tip micronucleus technology of Vicia faba. MethodThe pollution of wastewater from a pharmaceutic...ObjectiveThe aim was to assess genetic and physiological toxicity of wastewater from a pharmaceutical factory using root tip micronucleus technology of Vicia faba. MethodThe pollution of wastewater from a pharmaceutical factory was detected by using root tip micronucleus technology of Vicia faba, and the genetic and physiological toxicity of the wastewater to Vicia faba was assessed. ResultNon-processed wastewater had an extremely high level of biological toxicity; the cells were unable to live with the wastewater at a high concentration; the cells were able to grow with the wastewater at a low concentration, though the micronucleus ratio was extremely high. The processed wastewater had no significant impact on cell growth, but the micronucleus ratio was extremely high, showing that the processed water also had a high pollution index. ConclusionThe research could provide scientific references for the national treatment of wastewater from a pharmaceutical factory.展开更多
In the present paper,three dimensional analyses of some general constraint parameters and fracture parameters near the crack tip of Mode I CT specimens in two different thicknesses are carried out by employing ADINA p...In the present paper,three dimensional analyses of some general constraint parameters and fracture parameters near the crack tip of Mode I CT specimens in two different thicknesses are carried out by employing ADINA program.The results reveal that the constraints along the thickness direction are obviously separated into two parts:the keeping similar high constraint field(Z_(1))and rapid reducing constraints one(Z_(2)).The two fields are experimentally confiremed to correspond to the smooth region and the shear lip on the fracture face respectively.So the three dimensional stress structure of Mode I specimens can be derived through discussing the two fields respectively.The distribution of the Crack Tip Opening Displacement(CTOD)along the thickness direction and the three dimensional distribution of the void growth ratio(V_(g))near the crack tip are also obtained.The two fracture parameters are in similar trends along the thickness direction,and both of them can reflect the effect of thickness and that of the loading level to a certain degree.展开更多
针对风速随机性给风能转换系统(wind energy conversion system,WECS)带来的非线性和参数不确定性,提出了一种模糊自耦合PI控制方案用于低风速的最大功率点跟踪。自耦合PI被用来完成基本的转速跟踪,以实现对风力机尖速比的最优化控制。...针对风速随机性给风能转换系统(wind energy conversion system,WECS)带来的非线性和参数不确定性,提出了一种模糊自耦合PI控制方案用于低风速的最大功率点跟踪。自耦合PI被用来完成基本的转速跟踪,以实现对风力机尖速比的最优化控制。而模糊控制器则被用来获取自耦合PI在不同工作点下的控制参数,以提高系统对风速变化的适应能力。为了验证所提方案的可行性,在Matlab/Simulink搭建的2 MW风能转换系统仿真模型中开展了与传统方法的对比实验。仿真结果表明,相比于传统PI、模糊PI以及GA-PI,所提出方法拥有更佳的转速跟踪性能、更平滑的响应曲线以及更多的电能输出。展开更多
文摘Currently, domestic and abroad scholars put more attention on contra-rotating dual-rotor axial fan. But there is less scholars study on asymmetric dual-rotor small axial fan, which is one of the contra-rotating dual-rotor axial fans. Like axial fan, many factors have influence on the performance of the asymmetric dual-rotor small axial flow fan, such as the wheel hub ratio, blade shape, blade number, stagger angle and the tip clearance. Because wheel hub ratio has great impact on the performance of the fan, we choose the size of wheel hub ratio as a variable factor to study the model change. There is a different wheel hub ratio between front stage impeller and rear stage of asymmetric dual-rotor small axial fan, so it is very beneficial to select the greater wind area that the fan area of external diameter minuses the area occupied by the blades and the hub as front stage impeller. In this paper, the hub-ratio of front stage impeller is 0.72, and that of rear stage is 0.72, 0.67 and 0.62 respectively along with the front stage impeller. Three kinds of models with different hub ratio of rear stage are simulated using the CFD software and the static characteristics are obtained. Based on the experimental test results, the internal flow field of the asymmetric dual-rotor small axial fan is analyzed in detail, the impact trends of different hub-ratio on the performance of asymmetric dual-rotor small axial fan are obtained and the argument of structure optimization for dual-rotor small axial fan is provided.
文摘Under the condition that all the perfectly plastic stress components at a crack tip are the functions of ? only, making use of equilibrium equations and Von-Mises yield condition containing Poisson ratio, in this paper, we derive the generally analytical expressions of perfectly plastic stress field at a stationary plane-strain crack tip. Applying these generally analytical expressions to the concrete cracks, the analytical expressions of perfectly plastic stress fields at the stationary tips of Mode I, Mode II and Mixed-Mode I-II plane-strain cracks are obtained. These analytical expressions contain Poisson ratio.
文摘ObjectiveThe aim was to assess genetic and physiological toxicity of wastewater from a pharmaceutical factory using root tip micronucleus technology of Vicia faba. MethodThe pollution of wastewater from a pharmaceutical factory was detected by using root tip micronucleus technology of Vicia faba, and the genetic and physiological toxicity of the wastewater to Vicia faba was assessed. ResultNon-processed wastewater had an extremely high level of biological toxicity; the cells were unable to live with the wastewater at a high concentration; the cells were able to grow with the wastewater at a low concentration, though the micronucleus ratio was extremely high. The processed wastewater had no significant impact on cell growth, but the micronucleus ratio was extremely high, showing that the processed water also had a high pollution index. ConclusionThe research could provide scientific references for the national treatment of wastewater from a pharmaceutical factory.
文摘In the present paper,three dimensional analyses of some general constraint parameters and fracture parameters near the crack tip of Mode I CT specimens in two different thicknesses are carried out by employing ADINA program.The results reveal that the constraints along the thickness direction are obviously separated into two parts:the keeping similar high constraint field(Z_(1))and rapid reducing constraints one(Z_(2)).The two fields are experimentally confiremed to correspond to the smooth region and the shear lip on the fracture face respectively.So the three dimensional stress structure of Mode I specimens can be derived through discussing the two fields respectively.The distribution of the Crack Tip Opening Displacement(CTOD)along the thickness direction and the three dimensional distribution of the void growth ratio(V_(g))near the crack tip are also obtained.The two fracture parameters are in similar trends along the thickness direction,and both of them can reflect the effect of thickness and that of the loading level to a certain degree.
文摘针对风速随机性给风能转换系统(wind energy conversion system,WECS)带来的非线性和参数不确定性,提出了一种模糊自耦合PI控制方案用于低风速的最大功率点跟踪。自耦合PI被用来完成基本的转速跟踪,以实现对风力机尖速比的最优化控制。而模糊控制器则被用来获取自耦合PI在不同工作点下的控制参数,以提高系统对风速变化的适应能力。为了验证所提方案的可行性,在Matlab/Simulink搭建的2 MW风能转换系统仿真模型中开展了与传统方法的对比实验。仿真结果表明,相比于传统PI、模糊PI以及GA-PI,所提出方法拥有更佳的转速跟踪性能、更平滑的响应曲线以及更多的电能输出。