The current ventilation condition of the hot and humid regions was analyzed through on-site investigation. It is found that residents in this region expect to improve indoor thermal environment through natural ventila...The current ventilation condition of the hot and humid regions was analyzed through on-site investigation. It is found that residents in this region expect to improve indoor thermal environment through natural ventilation as much as possible. Then,it comes to a conclusion by the field test that natural ventilation has certain practical effect on improving indoor thermal environment. CFD simulation software is employed to verify the test result. Based on PMV modified model,and according to norms,geography and climate combined with the measured and simulated results,the application of the time and effectiveness of natural ventilation in hot and humid region were analyzed,to some extent,providing a basis for reducing the air-conditioner's runtime with natural ventilation.展开更多
A new land cover classification system was established for the Three Gorges Reservoir Region(TGRR) after considering the continuity of inundation and the natural characteristics of land cover. The potential evapotrans...A new land cover classification system was established for the Three Gorges Reservoir Region(TGRR) after considering the continuity of inundation and the natural characteristics of land cover. The potential evapotranspiration(PET) was predicted using a modified Penman-Monteith(P-M) model. The region's ratio of precipitation to evapotranspiration was calculated as the humidity index(HI). The data obtained was used to analyze climatic responses to land cover conversions from the perspectives of evapotranspiration and humidity variations. The results show that, from 1997 to 2009, the average annual PET increased in the early years and decreased later. In terms of overall spatial distribution, a significant reciprocal relationship appeared between annual PET and annual HI. In 1997,the annual PET was higher in the lower reaches than in the upper reaches of the TGRR, but the areas with high PET shifted substantially westward by 2003. The annual PET continued to increase in 2006, but the areas with high PET shrank by 2009. In contrast, the annual HI showed varying degrees of localized spatial variability. Over the three periods, the dominantforms of land cover conversions occurred from evergreen cover to seasonal green cover, from seasonal green cover to evergreen cover, and from seasonal green cover to seasonally inundated areas, respectively. These accounted for 48.0%, 38.4%, and 23.8% of the total areas of converted land covers in the three periods, respectively. During the period between 1997 and 2003, the main forms of land cover conversions resulted in both positive and negative growths in the average annual PET, while all of them pushed down the average annual HI. From 2003 to 2006, the reservoir region experienced neither a decrease in the annual PET nor an increase in the annual HI. The period between 2006 and 2009 saw a consistent downward trend in the annual PET and a consistent upward trend in the annual HI.展开更多
Outdoor thermal comfort has always been a major issue due to its irreplaceable role in maintaining good health and energy use. Thus,quantitative analysis of outdoor thermal comfort and discussions on influential facto...Outdoor thermal comfort has always been a major issue due to its irreplaceable role in maintaining good health and energy use. Thus,quantitative analysis of outdoor thermal comfort and discussions on influential factors seem very necessary to achieve the climate-conscious urban design. Therefore,an outdoor thermal comfort questionnaire survey and the simultaneous field measurement were conducted in six different places during the hot and humid summertime in Shenzhen. The results show that the overall weather conditions during the investigation can be expressed with high temperature and high humidity with strong solar radiation. The micro-meteorological parameters of six test sites vary greatly due to their different regional spatial layouts.Moderate range of air temperature( Ta) is between 28 to 30 ℃ while that of relative humidity( RH) mainly concentrates in 60%-70% with the thermal sensation votes. The main influential factors impacting outdoor thermal comfort are obtained and Tahas the greatest effect. The overall thermal comfortable ranges in Shenzhen are expressed by the range of 28. 14-32. 83 ℃ of PET and 24. 74-30. 45 ℃ of SET*. With the correlation analysis between the characteristic parameters of regional spatial layout and thermal climate and thermal comfort,it reveals that increasing the coverage ratio of water and green space( S) helps lower Taand increase RH. The global solar radiation( G) has a significant negative correlation with the height of buildings( H) and a positive correlation with sky view factor( SVF). Overall,reasonable configuration of the regional spatial layout contributes to providing a thermal comfortable environment.展开更多
基金Project(50838009) supported by the National Natural Science Foundation of ChinaProject(2006BAJ01A05) supported by the National Key Technologies R&D Program of ChinaProject(CSTC,2008AB7110) supported by Key Technologies R & D Program of Chongqing City,China
文摘The current ventilation condition of the hot and humid regions was analyzed through on-site investigation. It is found that residents in this region expect to improve indoor thermal environment through natural ventilation as much as possible. Then,it comes to a conclusion by the field test that natural ventilation has certain practical effect on improving indoor thermal environment. CFD simulation software is employed to verify the test result. Based on PMV modified model,and according to norms,geography and climate combined with the measured and simulated results,the application of the time and effectiveness of natural ventilation in hot and humid region were analyzed,to some extent,providing a basis for reducing the air-conditioner's runtime with natural ventilation.
基金partially supported and funded by Chongqing Research Program of Basic Research and Frontier Technology (Grant No. cstc2017jcyj B0317)Chongqing University Innovation Team Building Plan (Grant No. CXTDX201601017)Science and Technology Project of Chongqing Municipal Education Commission (Grant No. KJ1738462)
文摘A new land cover classification system was established for the Three Gorges Reservoir Region(TGRR) after considering the continuity of inundation and the natural characteristics of land cover. The potential evapotranspiration(PET) was predicted using a modified Penman-Monteith(P-M) model. The region's ratio of precipitation to evapotranspiration was calculated as the humidity index(HI). The data obtained was used to analyze climatic responses to land cover conversions from the perspectives of evapotranspiration and humidity variations. The results show that, from 1997 to 2009, the average annual PET increased in the early years and decreased later. In terms of overall spatial distribution, a significant reciprocal relationship appeared between annual PET and annual HI. In 1997,the annual PET was higher in the lower reaches than in the upper reaches of the TGRR, but the areas with high PET shifted substantially westward by 2003. The annual PET continued to increase in 2006, but the areas with high PET shrank by 2009. In contrast, the annual HI showed varying degrees of localized spatial variability. Over the three periods, the dominantforms of land cover conversions occurred from evergreen cover to seasonal green cover, from seasonal green cover to evergreen cover, and from seasonal green cover to seasonally inundated areas, respectively. These accounted for 48.0%, 38.4%, and 23.8% of the total areas of converted land covers in the three periods, respectively. During the period between 1997 and 2003, the main forms of land cover conversions resulted in both positive and negative growths in the average annual PET, while all of them pushed down the average annual HI. From 2003 to 2006, the reservoir region experienced neither a decrease in the annual PET nor an increase in the annual HI. The period between 2006 and 2009 saw a consistent downward trend in the annual PET and a consistent upward trend in the annual HI.
基金Sponsored by Open Project of the State Key Laboratory of Urban Resource and Environment(Grant No.2010TS04)
文摘Outdoor thermal comfort has always been a major issue due to its irreplaceable role in maintaining good health and energy use. Thus,quantitative analysis of outdoor thermal comfort and discussions on influential factors seem very necessary to achieve the climate-conscious urban design. Therefore,an outdoor thermal comfort questionnaire survey and the simultaneous field measurement were conducted in six different places during the hot and humid summertime in Shenzhen. The results show that the overall weather conditions during the investigation can be expressed with high temperature and high humidity with strong solar radiation. The micro-meteorological parameters of six test sites vary greatly due to their different regional spatial layouts.Moderate range of air temperature( Ta) is between 28 to 30 ℃ while that of relative humidity( RH) mainly concentrates in 60%-70% with the thermal sensation votes. The main influential factors impacting outdoor thermal comfort are obtained and Tahas the greatest effect. The overall thermal comfortable ranges in Shenzhen are expressed by the range of 28. 14-32. 83 ℃ of PET and 24. 74-30. 45 ℃ of SET*. With the correlation analysis between the characteristic parameters of regional spatial layout and thermal climate and thermal comfort,it reveals that increasing the coverage ratio of water and green space( S) helps lower Taand increase RH. The global solar radiation( G) has a significant negative correlation with the height of buildings( H) and a positive correlation with sky view factor( SVF). Overall,reasonable configuration of the regional spatial layout contributes to providing a thermal comfortable environment.