针对采用碳氢固体推进剂的固体火箭超燃冲压发动机开展了地面直连试验。介绍了试验系统,测量了推力、压力、温度和质量流量等参数,分析了试验结果,得到燃烧室的性能。燃烧室总压损失为74.1%,燃烧效率为84.0%,推力增益为0.718 k N,推力...针对采用碳氢固体推进剂的固体火箭超燃冲压发动机开展了地面直连试验。介绍了试验系统,测量了推力、压力、温度和质量流量等参数,分析了试验结果,得到燃烧室的性能。燃烧室总压损失为74.1%,燃烧效率为84.0%,推力增益为0.718 k N,推力增益比冲为3 726.9N·s/kg。展开更多
Activated carbon samples were developed from coal samples obtained from a coal mine, rat (Zonguldak, Turkey) and anthracite (Siberia, Russia), applying pyrolysis in a temperature range of 600-900 ℃ under N2 flow,...Activated carbon samples were developed from coal samples obtained from a coal mine, rat (Zonguldak, Turkey) and anthracite (Siberia, Russia), applying pyrolysis in a temperature range of 600-900 ℃ under N2 flow, and activation using chemical agents such as KOH, NH4Cl, ZnCl2 at 650 ℃. Nitrogen adsorption at low temperature (77 K) was used to characterize the activated carbon samples, and their pore structure properties including pore volume, pore diameter and pore size distribution were determined by means of the t-plots and DFT methods. The surface area values were higher for rat coal samples than for anthracite one, and for the rat coal samples treated with KOH + NH4Cl + ZnCl2 at 650 °C [Rat650(2)] there are highest surface area and total pore volume, 315.6 m2·g^-1 and 0.156 ml·g^-1, respectively. The highest value of the hydrogen sorption capacity was found as 0.71% (by mass) for the rat coal sample obtained by KOH + ZnCl2 treatment at 650 °C [Rat650(1)].展开更多
基金provided by the project DPT2002K120640 funded by State Planning Organization (DPT), Turkey
文摘Activated carbon samples were developed from coal samples obtained from a coal mine, rat (Zonguldak, Turkey) and anthracite (Siberia, Russia), applying pyrolysis in a temperature range of 600-900 ℃ under N2 flow, and activation using chemical agents such as KOH, NH4Cl, ZnCl2 at 650 ℃. Nitrogen adsorption at low temperature (77 K) was used to characterize the activated carbon samples, and their pore structure properties including pore volume, pore diameter and pore size distribution were determined by means of the t-plots and DFT methods. The surface area values were higher for rat coal samples than for anthracite one, and for the rat coal samples treated with KOH + NH4Cl + ZnCl2 at 650 °C [Rat650(2)] there are highest surface area and total pore volume, 315.6 m2·g^-1 and 0.156 ml·g^-1, respectively. The highest value of the hydrogen sorption capacity was found as 0.71% (by mass) for the rat coal sample obtained by KOH + ZnCl2 treatment at 650 °C [Rat650(1)].