The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/D...The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/DC hybrid distribution network is put forward according to the demands of power grid, with advantages of accepting DG and DC loads, while clearing DC fault by blocking the clamping double sub-module(CDSM) of input stage. Then, this paper shows the typical structure of AC/DC distribution network that is hand in hand. Based on the new topology, this paper designs the control and modulation strategies of each stage, where the outer loop controller of input stage is emphasized for its twocontrol mode. At last, the rationality of new topology and the validity of control strategies are verified by the steady and dynamic state simulation. At the same time, the simulation results highlight the role of PET in energy regulation.展开更多
China Southern Power Grid is a unique EHV AC/DC hybrid transmission network that operates in China. In its service area, the distribution of energy resources and the development of economy are extremely unbalanced, so...China Southern Power Grid is a unique EHV AC/DC hybrid transmission network that operates in China. In its service area, the distribution of energy resources and the development of economy are extremely unbalanced, so long-distance and bulk power transmission are needed; besides, the geography and climate conditions are serious, rains, fogs, lightning and typhoon as well as high temperature are common all the year round. Facing these challenges, the power grid enhanced stability control, improved the equipment and strengthen the network structure. In the future, the power grid plans to optimize the disposition of power sources and build digitalized power system.展开更多
The increasing flexibility of active distribution systems(ADSs)coupled with the high penetration of renewable distributed generators(RDGs)leads to the increase of the complexity.It is of practical significance to achi...The increasing flexibility of active distribution systems(ADSs)coupled with the high penetration of renewable distributed generators(RDGs)leads to the increase of the complexity.It is of practical significance to achieve the largest amount of RDG penetration in ADSs and maintain the optimal operation.This study establishes an alternating current(AC)/direct current(DC)hybrid ADS model that considers the dynamic thermal rating,soft open point,and distribution network reconfiguration(DNR).Moreover,it transforms the optimal dispatching into a second-order cone programming problem.Considering the different control time scales of dispatchable resources,the following two-stage dispatching framework is proposed.d dispatch uses hourly input data with the goal(1)The day-ahea of minimizing the grid loss and RDG dropout.It obtains the optimal 24-hour schedule to determine the dispatching plans for DNR and the energy storage system.(2)The intraday dispatch uses 15-min input data for 1-hour rolling-plan dispatch but only executes the first 15 min of dispatching.To eliminate error between the actual operation and dispatching plan,the first 15 min is divided into three 5-min step-by-step executions.The goal of each step is to trace the tie-line power of the intraday rolling-plan dispatch to the greatest extent at the minimum cost.The measured data are used as feedback input for the rolling-plan dispatch after each step is executed.A case study shows that the comprehensive cooperative ADS model can release the line capacity,reduce losses,and improve the penetration rate of RDGs.Further,the two-stage dispatching framework can handle source-load fluctuations and enhance system stability.展开更多
The upscaling requirements of energy transition highlight the urgent need for ramping up renewables and boosting system efficiencies.However,the stochastic nature of excessive renewable energy resources has challenged...The upscaling requirements of energy transition highlight the urgent need for ramping up renewables and boosting system efficiencies.However,the stochastic nature of excessive renewable energy resources has challenged stable and efficient operation of the power system.Battery energy storage systems(BESSs)have been identified as critical to mitigate random fluctuations,unnecessary green energy curtailment and load shedding with rapid response and flexible connection.On the other hand,an AC/DC hybrid distribution system can offer merged benefits in both AC and DC subsystems without additional losses during AC/DC power conversion.Therefore,configuring BESSs on an AC/DC distribution system is wellpositioned to meet challenges brought by carbon reductions in an efficient way.A bi-level optimization model of BESS capacity allocation for AC/DC hybrid distribution systems,considering the flexibility of voltage source converters(VSCs)and power conversion systems(PCSs),has been established in this paper to address the techno-economic issues that hindered wide implementation.The large-scale nonlinear programming problem has been solved utilizing a genetic algorithm combined with second-order cone programming.Rationality and effectiveness of the model have been verified by setting different scenarios through case studies.Simulation results have demonstrated the coordinated operation of BESS and AC/DC hybrid systems can effectively suppress voltage fluctuations and improve the cost-benefit of BESSs from a life cycle angle.展开更多
Hybrid AC/DC distribution networks are promising candidates for future applications due to their rapid advancement in power electronics technology.They use interface converters(IFCs)to link DC and AC distribution netw...Hybrid AC/DC distribution networks are promising candidates for future applications due to their rapid advancement in power electronics technology.They use interface converters(IFCs)to link DC and AC distribution networks.However,the networks possess drawbacks with AC voltage and frequency offsets when transferring from grid-tied to islanding modes.To address these problems,this paper proposes a simple but effective strategy based on the reverse droop method.Initially,the power balance equation of the distribution system is derived,which reveals that the cause of voltage and frequency offsets is the mismatch between the IFC output power and the rated load power.Then,the reverse droop control is introduced into the IFC controller.By using a voltage-active power/frequency-reactive power(U-P/f-Q)reverse droop loop,the IFC output power enables adaptive tracking of the rated load power.Therefore,the AC voltage offset and frequency offset are suppressed during the transfer process of operational modes.In addition,the universal parameter design method is discussed based on the stability limitations of the control system and the voltage quality requirements of AC critical loads.Finally,simulation and experimental results clearly validate the proposed control strategy and parameter design method.展开更多
In the context of evolving energy needs and environmental concerns,efficient management of distributed energy resources within microgrids has gained prominence.This paper addresses the optimization of power flow manag...In the context of evolving energy needs and environmental concerns,efficient management of distributed energy resources within microgrids has gained prominence.This paper addresses the optimization of power flow management in a hybrid AC/DC microgrid through an energy management system driven by particle swarm optimization.Unlike traditional approaches that focus solely on active power distribution,our energy management system optimizes both active and reactive power allocation among sources.By leveraging 24-hour-ahead forecasting data encompassing load predictions,tariff rates and weather conditions,our strategy ensures an economically and environmentally optimized microgrid operation.Our proposed energy management system has dual objectives:minimizing costs and reducing greenhouse gas emissions.Through optimized operation of polluting sources and efficient utilization of the energy storage system,our approach achieved significant cost savings of~15%compared with the genetic algorithm coun-terpart.This was largely attributed to the streamlined operation of the gas turbine system,which reduced fuel consumption and associated expenses.Moreover,particle swarm optimization maintained the efficiency of the gas turbine by operating at~80%of its nominal power,effectively lowering greenhouse gas emissions.The effectiveness of our proposed strategy is validated through simu-lations conducted using the MATLAB®software environment.展开更多
Strong DC coupling with weak AC and large-scale renewable energy integration are the two significant characteristics of ultra-high-voltage AC/DC(UHVAC/DC)hybrid power grids in China.Strong coupling between AC and DC g...Strong DC coupling with weak AC and large-scale renewable energy integration are the two significant characteristics of ultra-high-voltage AC/DC(UHVAC/DC)hybrid power grids in China.Strong coupling between AC and DC grids and the different integration performance of renewable energy sources have profoundly changed the stability characteristics of the power system.The traditional stability control system is inadequate for the stability control of UHVAC/DC power grids.This paper analyzes the requirements for constructing an integrated defense system in a UHVAC/DC hybrid power grid(i.e.power system protection).The definition,connotation,and designing principles of power system protection are put forward.The relationship between the power system protection and the traditional three-defense lines is investigated.The design principles,general hardware structure and main functions of a power system protection are presented.Key problems and technologies are specified in the construction of the power system protection.展开更多
In a hybrid AC/DC medium voltage distribution network, distributed generations(DGs), energy storage systems(ESSs), and the voltage source converters(VSCs)between AC and DC lines, have the ability to regulate node volt...In a hybrid AC/DC medium voltage distribution network, distributed generations(DGs), energy storage systems(ESSs), and the voltage source converters(VSCs)between AC and DC lines, have the ability to regulate node voltages in real-time. However, the voltage regulation abilities of above devices are limited by their ratings. And the voltage regulation efficiencies of these devices are also different. Besides, due to high r/x ratio, node voltages are influenced by both real and reactive power. In order to achieve the coordinated voltage regulation in a hybrid AC/DC distribution network, a priority-based real-time control strategy is proposed based on the voltage control effect of real and reactive power adjustment. The equivalence of real and reactive power adjustment on voltage control is considered in control area partition optimization, in which regulation efficiency and capability are taken as objectives.In order to accommodate more DGs, the coordination of controllable devices is achieved according to voltage sensitivities. Simulations studies are performed to verify the proposed method.展开更多
The concept of a flexible power electronics substation(FPES)was first applied in the Zhangbei DC distribution network demonstration project.As a multi-port power electronics transformer(PET)with different AC and DC vo...The concept of a flexible power electronics substation(FPES)was first applied in the Zhangbei DC distribution network demonstration project.As a multi-port power electronics transformer(PET)with different AC and DC voltage levels,the FPES has adopted a novel topology integrating modular multilevel converter(MMC)and four-winding medium frequency transformer(FWMFT)based multiport DC-DC converter,which can significantly reduce capacitance in each sub-module(SM)of a MMC and also save space and cost.In this paper,in order to accelerate speed of electromagnetic transient(EMT)simulations of FPES based hybrid AC/DC distribution systems,an averaged-value model(AVM)is proposed for efficient and accurate representation of FPES.Assume that all SM capacitor voltages are perfectly balanced in the MMC,then the MMC behavior can be modeled using controlled voltage sources based on modulation voltages from control systems.In terms of the averaged current transfer characteristics among the windings of the FWMFT,we consider that all multiport DC-DC converters are controlled with the same dynamics,a lumped averaged model using controlled current and voltage sources has been developed for these four-port DC-DC converters connected to the upper or lower arms of the MMC.The presented FPES AVM model has been tested and validated by comparison with a detailed IGBT-based EMT model.Results show that the AVM is significantly more efficient while maintaining its accuracy in an EMT simulation.展开更多
考虑到海上风电出力的随机性以及日益突出的生态环境问题,以含柔性直流输电技术(voltagesource converter high voltage direct current,VSC-HVDC)的交直流系统为研究对象,提出了考虑条件风险价值(conditional valueatrisk,CVaR)的两阶...考虑到海上风电出力的随机性以及日益突出的生态环境问题,以含柔性直流输电技术(voltagesource converter high voltage direct current,VSC-HVDC)的交直流系统为研究对象,提出了考虑条件风险价值(conditional valueatrisk,CVaR)的两阶段分布鲁棒低碳经济优化模型,构建了基于Kullback-Leibler(KL)散度的概率分布模糊集,同时利用条件风险价值量化了极端场景下的尾部风险,使得模型能够同时考虑概率分布不确定性以及处于最坏概率分布中极端场景下的尾部损失;此外,将阶梯型碳交易机制并入所提分布鲁棒模型中,通过合理利用柔性资源和储能装置,增强系统运行的灵活性,在兼顾运行风险的前提下,降低碳排放量的目标。再者,为了提高计算效率,在列和约束生成算法(column-and-constraint generation method,C&CG)和Multi-cut Benders分解算法的基础上提出了双循环分解算法。最后,在基于改进的IEEE RTS 79测试系统中验证了所提模型及算法的有效性。展开更多
针对现有配电网鲁棒调度方法缺乏对不确定参数相关性问题的考虑,提出了一种基于数据驱动多面体集合的交直流混合配电网鲁棒调度方法。首先,构建分布式光伏出力的传统多面体集合,利用历史数据驱动形成了相关性包络图,通过弯曲多面体集合...针对现有配电网鲁棒调度方法缺乏对不确定参数相关性问题的考虑,提出了一种基于数据驱动多面体集合的交直流混合配电网鲁棒调度方法。首先,构建分布式光伏出力的传统多面体集合,利用历史数据驱动形成了相关性包络图,通过弯曲多面体集合边界,建立了相关性多面体集合模型。然后,在此基础上,针对相关性多面体集合存在鲁棒性差和保守性大的问题,建立了数据驱动的多面体集合模型。进一步,建立了基于数据驱动多面体集合的交直流混合配电网鲁棒调度模型,并采用列与约束生成(column and constraint generation,CCG)算法对鲁棒调度模型进行求解。最后,改进的IEEE33节点系统仿真结果表明,基于数据驱动多面体集合的交直流混合配电网鲁棒调度方法可以减少优化结果的保守性,提高其鲁棒性,证明了所提出方法的有效性。展开更多
基金supported by National Key Research and Development Program of China (2016YFB0900500,2017YFB0903100)the State Grid Science and Technology Project (SGRI-DL-F1-51-011)
文摘The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/DC hybrid distribution network is put forward according to the demands of power grid, with advantages of accepting DG and DC loads, while clearing DC fault by blocking the clamping double sub-module(CDSM) of input stage. Then, this paper shows the typical structure of AC/DC distribution network that is hand in hand. Based on the new topology, this paper designs the control and modulation strategies of each stage, where the outer loop controller of input stage is emphasized for its twocontrol mode. At last, the rationality of new topology and the validity of control strategies are verified by the steady and dynamic state simulation. At the same time, the simulation results highlight the role of PET in energy regulation.
文摘China Southern Power Grid is a unique EHV AC/DC hybrid transmission network that operates in China. In its service area, the distribution of energy resources and the development of economy are extremely unbalanced, so long-distance and bulk power transmission are needed; besides, the geography and climate conditions are serious, rains, fogs, lightning and typhoon as well as high temperature are common all the year round. Facing these challenges, the power grid enhanced stability control, improved the equipment and strengthen the network structure. In the future, the power grid plans to optimize the disposition of power sources and build digitalized power system.
基金supported by Universiti Sains Malaysia through Research University Team(RUTeam)Grant Scheme(No.1001/PELECT/8580011)。
文摘The increasing flexibility of active distribution systems(ADSs)coupled with the high penetration of renewable distributed generators(RDGs)leads to the increase of the complexity.It is of practical significance to achieve the largest amount of RDG penetration in ADSs and maintain the optimal operation.This study establishes an alternating current(AC)/direct current(DC)hybrid ADS model that considers the dynamic thermal rating,soft open point,and distribution network reconfiguration(DNR).Moreover,it transforms the optimal dispatching into a second-order cone programming problem.Considering the different control time scales of dispatchable resources,the following two-stage dispatching framework is proposed.d dispatch uses hourly input data with the goal(1)The day-ahea of minimizing the grid loss and RDG dropout.It obtains the optimal 24-hour schedule to determine the dispatching plans for DNR and the energy storage system.(2)The intraday dispatch uses 15-min input data for 1-hour rolling-plan dispatch but only executes the first 15 min of dispatching.To eliminate error between the actual operation and dispatching plan,the first 15 min is divided into three 5-min step-by-step executions.The goal of each step is to trace the tie-line power of the intraday rolling-plan dispatch to the greatest extent at the minimum cost.The measured data are used as feedback input for the rolling-plan dispatch after each step is executed.A case study shows that the comprehensive cooperative ADS model can release the line capacity,reduce losses,and improve the penetration rate of RDGs.Further,the two-stage dispatching framework can handle source-load fluctuations and enhance system stability.
基金supported in part by the National Natural Science Foundation of China(No.51777134)in part by a joint project of NSFC of China and EPSRC of UK(No.52061635103 and EP/T021969/1).
文摘The upscaling requirements of energy transition highlight the urgent need for ramping up renewables and boosting system efficiencies.However,the stochastic nature of excessive renewable energy resources has challenged stable and efficient operation of the power system.Battery energy storage systems(BESSs)have been identified as critical to mitigate random fluctuations,unnecessary green energy curtailment and load shedding with rapid response and flexible connection.On the other hand,an AC/DC hybrid distribution system can offer merged benefits in both AC and DC subsystems without additional losses during AC/DC power conversion.Therefore,configuring BESSs on an AC/DC distribution system is wellpositioned to meet challenges brought by carbon reductions in an efficient way.A bi-level optimization model of BESS capacity allocation for AC/DC hybrid distribution systems,considering the flexibility of voltage source converters(VSCs)and power conversion systems(PCSs),has been established in this paper to address the techno-economic issues that hindered wide implementation.The large-scale nonlinear programming problem has been solved utilizing a genetic algorithm combined with second-order cone programming.Rationality and effectiveness of the model have been verified by setting different scenarios through case studies.Simulation results have demonstrated the coordinated operation of BESS and AC/DC hybrid systems can effectively suppress voltage fluctuations and improve the cost-benefit of BESSs from a life cycle angle.
基金This work was supported by the National Key R&D Program of China(2018YFB0904700).
文摘Hybrid AC/DC distribution networks are promising candidates for future applications due to their rapid advancement in power electronics technology.They use interface converters(IFCs)to link DC and AC distribution networks.However,the networks possess drawbacks with AC voltage and frequency offsets when transferring from grid-tied to islanding modes.To address these problems,this paper proposes a simple but effective strategy based on the reverse droop method.Initially,the power balance equation of the distribution system is derived,which reveals that the cause of voltage and frequency offsets is the mismatch between the IFC output power and the rated load power.Then,the reverse droop control is introduced into the IFC controller.By using a voltage-active power/frequency-reactive power(U-P/f-Q)reverse droop loop,the IFC output power enables adaptive tracking of the rated load power.Therefore,the AC voltage offset and frequency offset are suppressed during the transfer process of operational modes.In addition,the universal parameter design method is discussed based on the stability limitations of the control system and the voltage quality requirements of AC critical loads.Finally,simulation and experimental results clearly validate the proposed control strategy and parameter design method.
文摘In the context of evolving energy needs and environmental concerns,efficient management of distributed energy resources within microgrids has gained prominence.This paper addresses the optimization of power flow management in a hybrid AC/DC microgrid through an energy management system driven by particle swarm optimization.Unlike traditional approaches that focus solely on active power distribution,our energy management system optimizes both active and reactive power allocation among sources.By leveraging 24-hour-ahead forecasting data encompassing load predictions,tariff rates and weather conditions,our strategy ensures an economically and environmentally optimized microgrid operation.Our proposed energy management system has dual objectives:minimizing costs and reducing greenhouse gas emissions.Through optimized operation of polluting sources and efficient utilization of the energy storage system,our approach achieved significant cost savings of~15%compared with the genetic algorithm coun-terpart.This was largely attributed to the streamlined operation of the gas turbine system,which reduced fuel consumption and associated expenses.Moreover,particle swarm optimization maintained the efficiency of the gas turbine by operating at~80%of its nominal power,effectively lowering greenhouse gas emissions.The effectiveness of our proposed strategy is validated through simu-lations conducted using the MATLAB®software environment.
文摘Strong DC coupling with weak AC and large-scale renewable energy integration are the two significant characteristics of ultra-high-voltage AC/DC(UHVAC/DC)hybrid power grids in China.Strong coupling between AC and DC grids and the different integration performance of renewable energy sources have profoundly changed the stability characteristics of the power system.The traditional stability control system is inadequate for the stability control of UHVAC/DC power grids.This paper analyzes the requirements for constructing an integrated defense system in a UHVAC/DC hybrid power grid(i.e.power system protection).The definition,connotation,and designing principles of power system protection are put forward.The relationship between the power system protection and the traditional three-defense lines is investigated.The design principles,general hardware structure and main functions of a power system protection are presented.Key problems and technologies are specified in the construction of the power system protection.
文摘In a hybrid AC/DC medium voltage distribution network, distributed generations(DGs), energy storage systems(ESSs), and the voltage source converters(VSCs)between AC and DC lines, have the ability to regulate node voltages in real-time. However, the voltage regulation abilities of above devices are limited by their ratings. And the voltage regulation efficiencies of these devices are also different. Besides, due to high r/x ratio, node voltages are influenced by both real and reactive power. In order to achieve the coordinated voltage regulation in a hybrid AC/DC distribution network, a priority-based real-time control strategy is proposed based on the voltage control effect of real and reactive power adjustment. The equivalence of real and reactive power adjustment on voltage control is considered in control area partition optimization, in which regulation efficiency and capability are taken as objectives.In order to accommodate more DGs, the coordination of controllable devices is achieved according to voltage sensitivities. Simulations studies are performed to verify the proposed method.
基金This work was supported in part by the National Nature Science Foundation of China(51977142)。
文摘The concept of a flexible power electronics substation(FPES)was first applied in the Zhangbei DC distribution network demonstration project.As a multi-port power electronics transformer(PET)with different AC and DC voltage levels,the FPES has adopted a novel topology integrating modular multilevel converter(MMC)and four-winding medium frequency transformer(FWMFT)based multiport DC-DC converter,which can significantly reduce capacitance in each sub-module(SM)of a MMC and also save space and cost.In this paper,in order to accelerate speed of electromagnetic transient(EMT)simulations of FPES based hybrid AC/DC distribution systems,an averaged-value model(AVM)is proposed for efficient and accurate representation of FPES.Assume that all SM capacitor voltages are perfectly balanced in the MMC,then the MMC behavior can be modeled using controlled voltage sources based on modulation voltages from control systems.In terms of the averaged current transfer characteristics among the windings of the FWMFT,we consider that all multiport DC-DC converters are controlled with the same dynamics,a lumped averaged model using controlled current and voltage sources has been developed for these four-port DC-DC converters connected to the upper or lower arms of the MMC.The presented FPES AVM model has been tested and validated by comparison with a detailed IGBT-based EMT model.Results show that the AVM is significantly more efficient while maintaining its accuracy in an EMT simulation.
文摘考虑到海上风电出力的随机性以及日益突出的生态环境问题,以含柔性直流输电技术(voltagesource converter high voltage direct current,VSC-HVDC)的交直流系统为研究对象,提出了考虑条件风险价值(conditional valueatrisk,CVaR)的两阶段分布鲁棒低碳经济优化模型,构建了基于Kullback-Leibler(KL)散度的概率分布模糊集,同时利用条件风险价值量化了极端场景下的尾部风险,使得模型能够同时考虑概率分布不确定性以及处于最坏概率分布中极端场景下的尾部损失;此外,将阶梯型碳交易机制并入所提分布鲁棒模型中,通过合理利用柔性资源和储能装置,增强系统运行的灵活性,在兼顾运行风险的前提下,降低碳排放量的目标。再者,为了提高计算效率,在列和约束生成算法(column-and-constraint generation method,C&CG)和Multi-cut Benders分解算法的基础上提出了双循环分解算法。最后,在基于改进的IEEE RTS 79测试系统中验证了所提模型及算法的有效性。
文摘针对现有配电网鲁棒调度方法缺乏对不确定参数相关性问题的考虑,提出了一种基于数据驱动多面体集合的交直流混合配电网鲁棒调度方法。首先,构建分布式光伏出力的传统多面体集合,利用历史数据驱动形成了相关性包络图,通过弯曲多面体集合边界,建立了相关性多面体集合模型。然后,在此基础上,针对相关性多面体集合存在鲁棒性差和保守性大的问题,建立了数据驱动的多面体集合模型。进一步,建立了基于数据驱动多面体集合的交直流混合配电网鲁棒调度模型,并采用列与约束生成(column and constraint generation,CCG)算法对鲁棒调度模型进行求解。最后,改进的IEEE33节点系统仿真结果表明,基于数据驱动多面体集合的交直流混合配电网鲁棒调度方法可以减少优化结果的保守性,提高其鲁棒性,证明了所提出方法的有效性。