The corrosion behavior and the effects of temperature on critical chloride content (Ccrit) of steel fibers in RPC were analyzed by a pH meter, ion chromatography, mercury intrusion porosimetry (MIP), and electrochemic...The corrosion behavior and the effects of temperature on critical chloride content (Ccrit) of steel fibers in RPC were analyzed by a pH meter, ion chromatography, mercury intrusion porosimetry (MIP), and electrochemical techniques. It was found that the suspension pH value, the chloride binding capacity, and the total porosity of RPC were lower than those of high-performance concrete (HPC). The pore structure of RPC mainly consisted of gel pores. The Ccrit values of steel fibers in RPC and HPC at 20 ℃ were 1% and 2%, respectively. When the temperature reached 50 ℃, the Ccrit value of steel fibers in HPC decreased significantly, whereas it remained unchanged in RPC. The corrosion rate of corroded fibers in both RPC and HPC started to decrease with the rise in temperature.展开更多
The impact behaviour of three types of reactive powder concretes (RPC) was studied using the split Hopkinson press bar (SHPB) testing method. These RPC were prepared with steel fiber volume fraction of 0%, 3%, and...The impact behaviour of three types of reactive powder concretes (RPC) was studied using the split Hopkinson press bar (SHPB) testing method. These RPC were prepared with steel fiber volume fraction of 0%, 3%, and 4%, respectively. The stress-strain relationship, strain rate sensitivity threshold value, dynamic strength increase factor, modulus of elasticity and failure pattern of these RPC specimens subjected to impact load were investigated. From the tests, the strain rate sensitivity threshold value of 50 s-1 was obtained. The experimental results showed that when the strain rate increased from the threshold value to 95 s-1, the maximum stress of RPC increased by about 20% and the modulus of elasticity of RPC increased by about 30%. The failure pattern of RPC specimens with steel fiber reinforcement was very different from that of the RPC matrix specimen when subjected to impact loading. Under similar impact loading rate, cracks developed in the steel fiber reinforced RPC specimens, whilst the RPC matrix specimens were broken into small pieces.展开更多
This study examines the properties of fiber-reinforced reactive powder concrete (FR-RPC). Steel fibers, glass fibers, and steel-glass hybrid fibers were used to prepare the FR-RPC. The non-fibrous reactive powder conc...This study examines the properties of fiber-reinforced reactive powder concrete (FR-RPC). Steel fibers, glass fibers, and steel-glass hybrid fibers were used to prepare the FR-RPC. The non-fibrous reactive powder concrete (NF-RPC) was prepared as a reference mix. The proportion of fibers by volume for all FR-RPC mixes was 1.5%. Steel fibers of 13 mm length and 0.2 mm diameter were used to prepare the steel fiber-reinforced RPC (SFR-RPC). Glass fibers of 13 mm length and 1.3 mm diameter were used to prepare the glass fiber-reinforced RPC (GFR-RPC). The hybrid fiber-reinforced RPC (HFR-RPC) was prepared by mixing 0.9% steel fibers and 0.6% glass fibers. Compressive strength, axial load-axial deformation behavior, modulus of elasticity, indirect tensile strength, and shear strength of the RPC mixes were investigated. The results showed that SFR-RPC achieved higher compressive strength, indirect tensile strength and shear strength than NF-RPC, GFR-RPC, and HFR-RPC. Although the compressive strengths of GFR-RPC and HFR-RPC were slightly lower than the compressive strength of NF-RPC, the shear strengths of GFR-RPC and HFR-RPC were higher than that of NF-RPC.展开更多
Reactive powder concrete (RPC) is a novel cement-based composite material with ultra-high strength. Embedding a certain amount of short steel fibers in the matrix can improve the RPC’s toughness and overcome the disa...Reactive powder concrete (RPC) is a novel cement-based composite material with ultra-high strength. Embedding a certain amount of short steel fibers in the matrix can improve the RPC’s toughness and overcome the disadvantage of high brittle- ness. In this paper, a number of direct uniaxial tension tests have been carried out with ‘8-shape’ RPC200 specimens. The bond-slip process, mesoscopic structural variation and mechanical characteristics of a fiber pullout of the matrix have been investigated using the real-time SEM loading system and CCD observation tech- niques. The influence of the volume of embedded short steel fibers in matrix on the mesoscopic morphology of attachments on the surface of a pulled individual fiber, the initial cracking force, the ultimate pullout force, interfacial bond strength and the pullout rupture energy have been analyzed. A general formulation relating these quantities to the volume of fibers in matrix has been proposed. The components comprising the interfacial bond strength have been outlined. In addition, the con- tribution that fibers make to enhance and toughen the reactive powder concrete has been discussed. It is shown that there exists an optimal threshold of fiber volume ρv, opt =1.5% at which the bond performance of a fiber pullout of RPC be- haves best.展开更多
The thermophysical properties,such as thermal conductivity,thermal diffusivity,specific heat capacity and linear thermal expansion of reactive powder concrete(RPC) with different steel fiber volumetric fractions are i...The thermophysical properties,such as thermal conductivity,thermal diffusivity,specific heat capacity and linear thermal expansion of reactive powder concrete(RPC) with different steel fiber volumetric fractions are investigated by means of high temperature tests. The thermophysical characteristics of RPC with different fiber volumes under different temperatures are analyzed and compared with those of the common high-strength concrete and high-performance concrete. The empirical relationships of thermophysical properties with temperature and fiber volume are identified. By the heat transfer and solid physics methods,the microscopic physical mechanism of heat transfer process and heat conduction properties of RPC are investigated,and the theoretical formulas of specific heat capacity and thermal expansion coefficient are derived,respectively. The effects of temperature and steel fibers on the specific heat capacity and the thermal expansion coefficient are quantitatively analyzed and the discriminant conditions are provided. It is shown that the experimental results are consistent with the theoretical prediction.展开更多
Polypropylene fibers are embedded to prevent reactive powder concrete (RPC) from spalling failure under high temperatures. This paper probes the influence of embedded fibers at various volumetric dosages on the ther...Polypropylene fibers are embedded to prevent reactive powder concrete (RPC) from spalling failure under high temperatures. This paper probes the influence of embedded fibers at various volumetric dosages on the thermomechanical properties of polypropylene-fibered reactive powder concrete (PPRPC) exposed to high tem- peratures up to 350 ℃ and on the spalling performance and characteristics up to 600 ℃. The thermomechanical prop- erties include the characteristic temperature for spalling, and residual strengths, such as the compressive strength, split tensile strength, and flexural tensile strength. A high- definition charge-coupled device camera and scanning electron microscope technology were employed to capture the spalling processes and to detect the microstructural changes in the materials with various fiber dosages. To understand and characterize the mechanism by which polypropylene fibers influence the thermal spalling of RPC, a numerical model to determine the moisture migration and vapor pressure transmission during spalling was developed in this paper. It showed that there was an optimal volu- metric dosage of fibers to prevent PPRPC from explosive spalling. The relationships between the mechanical char- acteristics of PPRPC and the fiber dosages were derived based on experimental data.展开更多
基金Funded by the National Natural Science Foundation of China(Nos.51834001 and 51678049)。
文摘The corrosion behavior and the effects of temperature on critical chloride content (Ccrit) of steel fibers in RPC were analyzed by a pH meter, ion chromatography, mercury intrusion porosimetry (MIP), and electrochemical techniques. It was found that the suspension pH value, the chloride binding capacity, and the total porosity of RPC were lower than those of high-performance concrete (HPC). The pore structure of RPC mainly consisted of gel pores. The Ccrit values of steel fibers in RPC and HPC at 20 ℃ were 1% and 2%, respectively. When the temperature reached 50 ℃, the Ccrit value of steel fibers in HPC decreased significantly, whereas it remained unchanged in RPC. The corrosion rate of corroded fibers in both RPC and HPC started to decrease with the rise in temperature.
基金Funded by the National Natural Science Foundation of China(Nos.51478128,51278135 and 50708022)the Scientific and Research Developing Project of Ministry of Housing and Urban-Rural Development of China(2010-K3-27)+1 种基金the Guangzhou Government Higher Vocational Colleges&Schools Yang Cheng Scholar Funded Scheme(10A043G)the Foundation for Fostering the Scientific and Technical Innovation of Guangzhou University
文摘The impact behaviour of three types of reactive powder concretes (RPC) was studied using the split Hopkinson press bar (SHPB) testing method. These RPC were prepared with steel fiber volume fraction of 0%, 3%, and 4%, respectively. The stress-strain relationship, strain rate sensitivity threshold value, dynamic strength increase factor, modulus of elasticity and failure pattern of these RPC specimens subjected to impact load were investigated. From the tests, the strain rate sensitivity threshold value of 50 s-1 was obtained. The experimental results showed that when the strain rate increased from the threshold value to 95 s-1, the maximum stress of RPC increased by about 20% and the modulus of elasticity of RPC increased by about 30%. The failure pattern of RPC specimens with steel fiber reinforcement was very different from that of the RPC matrix specimen when subjected to impact loading. Under similar impact loading rate, cracks developed in the steel fiber reinforced RPC specimens, whilst the RPC matrix specimens were broken into small pieces.
文摘This study examines the properties of fiber-reinforced reactive powder concrete (FR-RPC). Steel fibers, glass fibers, and steel-glass hybrid fibers were used to prepare the FR-RPC. The non-fibrous reactive powder concrete (NF-RPC) was prepared as a reference mix. The proportion of fibers by volume for all FR-RPC mixes was 1.5%. Steel fibers of 13 mm length and 0.2 mm diameter were used to prepare the steel fiber-reinforced RPC (SFR-RPC). Glass fibers of 13 mm length and 1.3 mm diameter were used to prepare the glass fiber-reinforced RPC (GFR-RPC). The hybrid fiber-reinforced RPC (HFR-RPC) was prepared by mixing 0.9% steel fibers and 0.6% glass fibers. Compressive strength, axial load-axial deformation behavior, modulus of elasticity, indirect tensile strength, and shear strength of the RPC mixes were investigated. The results showed that SFR-RPC achieved higher compressive strength, indirect tensile strength and shear strength than NF-RPC, GFR-RPC, and HFR-RPC. Although the compressive strengths of GFR-RPC and HFR-RPC were slightly lower than the compressive strength of NF-RPC, the shear strengths of GFR-RPC and HFR-RPC were higher than that of NF-RPC.
基金Supported by the National Basic Research Program of China (Grant No. 2002CB412705)New Century Excellent Talents Program (Grant No. NCET-05- 0215)Laboratory Project of Beijing Science and Education Committee (Grant No. JD102900663)
文摘Reactive powder concrete (RPC) is a novel cement-based composite material with ultra-high strength. Embedding a certain amount of short steel fibers in the matrix can improve the RPC’s toughness and overcome the disadvantage of high brittle- ness. In this paper, a number of direct uniaxial tension tests have been carried out with ‘8-shape’ RPC200 specimens. The bond-slip process, mesoscopic structural variation and mechanical characteristics of a fiber pullout of the matrix have been investigated using the real-time SEM loading system and CCD observation tech- niques. The influence of the volume of embedded short steel fibers in matrix on the mesoscopic morphology of attachments on the surface of a pulled individual fiber, the initial cracking force, the ultimate pullout force, interfacial bond strength and the pullout rupture energy have been analyzed. A general formulation relating these quantities to the volume of fibers in matrix has been proposed. The components comprising the interfacial bond strength have been outlined. In addition, the con- tribution that fibers make to enhance and toughen the reactive powder concrete has been discussed. It is shown that there exists an optimal threshold of fiber volume ρv, opt =1.5% at which the bond performance of a fiber pullout of RPC be- haves best.
基金supported by the National Natural Science Foundation of China (Grant No. 50974125)the National Basic Research Program of China ("973" Project) (Grant Nos.2010CB226804,2002CB412705)the Beijing Key Laboratory Projects
文摘The thermophysical properties,such as thermal conductivity,thermal diffusivity,specific heat capacity and linear thermal expansion of reactive powder concrete(RPC) with different steel fiber volumetric fractions are investigated by means of high temperature tests. The thermophysical characteristics of RPC with different fiber volumes under different temperatures are analyzed and compared with those of the common high-strength concrete and high-performance concrete. The empirical relationships of thermophysical properties with temperature and fiber volume are identified. By the heat transfer and solid physics methods,the microscopic physical mechanism of heat transfer process and heat conduction properties of RPC are investigated,and the theoretical formulas of specific heat capacity and thermal expansion coefficient are derived,respectively. The effects of temperature and steel fibers on the specific heat capacity and the thermal expansion coefficient are quantitatively analyzed and the discriminant conditions are provided. It is shown that the experimental results are consistent with the theoretical prediction.
基金supported by the National Natural Science Foundation of China(51125017 and 50974125)Research Fund for Doctoral Programs of Chinese Ministry of Education(20110023110015)+1 种基金the Fund for Creative Research & Development Group Program of Jiangsu Provincethe Priority Academic Program Development of Jiangsu Higher Education Institutions(PAPD)
文摘Polypropylene fibers are embedded to prevent reactive powder concrete (RPC) from spalling failure under high temperatures. This paper probes the influence of embedded fibers at various volumetric dosages on the thermomechanical properties of polypropylene-fibered reactive powder concrete (PPRPC) exposed to high tem- peratures up to 350 ℃ and on the spalling performance and characteristics up to 600 ℃. The thermomechanical prop- erties include the characteristic temperature for spalling, and residual strengths, such as the compressive strength, split tensile strength, and flexural tensile strength. A high- definition charge-coupled device camera and scanning electron microscope technology were employed to capture the spalling processes and to detect the microstructural changes in the materials with various fiber dosages. To understand and characterize the mechanism by which polypropylene fibers influence the thermal spalling of RPC, a numerical model to determine the moisture migration and vapor pressure transmission during spalling was developed in this paper. It showed that there was an optimal volu- metric dosage of fibers to prevent PPRPC from explosive spalling. The relationships between the mechanical char- acteristics of PPRPC and the fiber dosages were derived based on experimental data.