HVDC technology has been widely used in modern power system. On one hand, HVDC has the advantages of economy, high efficiency and strong controllability. While on the other hand, it makes the dynamic characteristics o...HVDC technology has been widely used in modern power system. On one hand, HVDC has the advantages of economy, high efficiency and strong controllability. While on the other hand, it makes the dynamic characteristics of the power system becoming more and more complex. That puts forward a new challenge to system stability and raises new questions for power system simulation. This paper focuses on the interaction between AC and DC systems, especially the problem of commutation failure caused by AC system fault. Based on the data of China Southern Power Grid, this paper calculates the fault regions that may cause commutation failure and calculates the system critical clearance time under different load models, analyzes the impacts of different load models on commutation failure and the stability of AC/DC hybrid system.展开更多
This paper presents an proportional integral (PI) based voltage-reactive power control for wind diesel based decentralized hybrid power system with wide range of disturbances to demonstrate the compensation effect on ...This paper presents an proportional integral (PI) based voltage-reactive power control for wind diesel based decentralized hybrid power system with wide range of disturbances to demonstrate the compensation effect on system with intelligent tuning methods such as genetic algorithm (GA), artificial neural network (ANN) and adaptive neuro fuzzy inference system (ANFIS). The effect of probabilistic load and/or input power pattern is introduced which is incorporated in MATLAB simulink model developed for the study of decentralized hybrid power system. Results show how tuning method becomes important with high percentage of probabilistic pattern in system. Testing of all tuning methods shows that GA, ANN and ANFIS can preserve optimal performances over wide range of disturbances with superiority to GA in terms of settling time using Integral of Square of Errors (ISE) criterion as fitness function.展开更多
针对燃料电池船舶复合供能系统中的燃料电池功率波动问题和储能单元电池荷电状态(State of Charge, SOC)极端分化问题,依据系统拓扑结构,提出基于负载功率频率分解与模糊逻辑控制法相结合的复合供能系统控制策略设计。采用实例仿真验证...针对燃料电池船舶复合供能系统中的燃料电池功率波动问题和储能单元电池荷电状态(State of Charge, SOC)极端分化问题,依据系统拓扑结构,提出基于负载功率频率分解与模糊逻辑控制法相结合的复合供能系统控制策略设计。采用实例仿真验证该设计的优势。结果表明,该设计可有效保持燃料电池输出功率平滑,对储能单元SOC具有良好的均衡控制效果。展开更多
It is well recognized that the voltage stability of a power system is affected by the load model and hence, to effectively analyze the reactive power compensation of an isolated hybrid wind-diesel based power system, ...It is well recognized that the voltage stability of a power system is affected by the load model and hence, to effectively analyze the reactive power compensation of an isolated hybrid wind-diesel based power system, the loads need to be considered along with the generators in a transient analysis. This paper gives a detailed mathematical modeling to compute the reactive power response with small voltage perturbation for composite load. The composite load is a combination of the static and dynamic load model. To develop this composite load model, the exponential load is used as a static load model and induction motors (IMs) are used as a dynamic load model. To analyze the dynamics of IM load, the fifth, third and first order model of IM are formulated and compared using differential equations solver in Matlab coding. Since the decentralized areas have many small consumers which may consist large numbers of IMs of small rating, it is not realistic to model either a single large rating unit or all small rating IMs together that are placed in the system. In place of using a single large rating IM, a group of motors are considered and then the aggregate model of IM is developed using the law of energy conservation. This aggregate model is used as a dynamic load model. For different simulation studies, especially in the area of voltage stability with reactive power compensation of an isolated hybrid power system, the transfer function AQ/AV of the composite load is required. The transfer function of the composite load is derived in this paper by successive derivation for the exponential model of static load and for the fifth and third order IM dynamic load model using state space model.展开更多
文摘HVDC technology has been widely used in modern power system. On one hand, HVDC has the advantages of economy, high efficiency and strong controllability. While on the other hand, it makes the dynamic characteristics of the power system becoming more and more complex. That puts forward a new challenge to system stability and raises new questions for power system simulation. This paper focuses on the interaction between AC and DC systems, especially the problem of commutation failure caused by AC system fault. Based on the data of China Southern Power Grid, this paper calculates the fault regions that may cause commutation failure and calculates the system critical clearance time under different load models, analyzes the impacts of different load models on commutation failure and the stability of AC/DC hybrid system.
文摘This paper presents an proportional integral (PI) based voltage-reactive power control for wind diesel based decentralized hybrid power system with wide range of disturbances to demonstrate the compensation effect on system with intelligent tuning methods such as genetic algorithm (GA), artificial neural network (ANN) and adaptive neuro fuzzy inference system (ANFIS). The effect of probabilistic load and/or input power pattern is introduced which is incorporated in MATLAB simulink model developed for the study of decentralized hybrid power system. Results show how tuning method becomes important with high percentage of probabilistic pattern in system. Testing of all tuning methods shows that GA, ANN and ANFIS can preserve optimal performances over wide range of disturbances with superiority to GA in terms of settling time using Integral of Square of Errors (ISE) criterion as fitness function.
文摘针对燃料电池船舶复合供能系统中的燃料电池功率波动问题和储能单元电池荷电状态(State of Charge, SOC)极端分化问题,依据系统拓扑结构,提出基于负载功率频率分解与模糊逻辑控制法相结合的复合供能系统控制策略设计。采用实例仿真验证该设计的优势。结果表明,该设计可有效保持燃料电池输出功率平滑,对储能单元SOC具有良好的均衡控制效果。
文摘It is well recognized that the voltage stability of a power system is affected by the load model and hence, to effectively analyze the reactive power compensation of an isolated hybrid wind-diesel based power system, the loads need to be considered along with the generators in a transient analysis. This paper gives a detailed mathematical modeling to compute the reactive power response with small voltage perturbation for composite load. The composite load is a combination of the static and dynamic load model. To develop this composite load model, the exponential load is used as a static load model and induction motors (IMs) are used as a dynamic load model. To analyze the dynamics of IM load, the fifth, third and first order model of IM are formulated and compared using differential equations solver in Matlab coding. Since the decentralized areas have many small consumers which may consist large numbers of IMs of small rating, it is not realistic to model either a single large rating unit or all small rating IMs together that are placed in the system. In place of using a single large rating IM, a group of motors are considered and then the aggregate model of IM is developed using the law of energy conservation. This aggregate model is used as a dynamic load model. For different simulation studies, especially in the area of voltage stability with reactive power compensation of an isolated hybrid power system, the transfer function AQ/AV of the composite load is required. The transfer function of the composite load is derived in this paper by successive derivation for the exponential model of static load and for the fifth and third order IM dynamic load model using state space model.