AIM:To investigate the feasibility and safety of Natural orifice trans-umbilical endoscopic cholecystectomy with a water-jet hybrid-knife in a non-survival porcine model.METHODS:Pure natural orifice transluminal endos...AIM:To investigate the feasibility and safety of Natural orifice trans-umbilical endoscopic cholecystectomy with a water-jet hybrid-knife in a non-survival porcine model.METHODS:Pure natural orifice transluminal endoscopic surgery(NOTES) cholecystectomy was performed on three non-survival pigs,by transumbilical approach,using a water-jet hybrid-knife. Under general anesthesia,the following steps detailed the procedure:(1) incision of the umbilicus followed by the passage of a double-channel flexible endsocope through an overtube into the peritoneal cavity;(2) establishment of pneumoperitoneum;(3) abdominal exploration;(4)endoscopic cholecystectomy:dissection of the gallbladder performed using water jet equipment,ligation of the cystic artery and duct conducted using nylon loops;and(5) necropsy with macroscopic evaluation.RESULTS:Transumbilical endoscopic cholecystectomy was successfully completed in the first and third pig,with minor bleedings. The dissection times were 137and 42 min,respectively. The total operation times were 167 and 69 min,respectively. And the lengths of resected specimen were 6.5 and 6.1 cm,respectively.Instillation of the fluid into the gallbladder bed produced edematous,distended tissue making separation safe and easy. Reliable ligation using double nylon loops insured the safety of cutting between the loops.There were no intraoperative complications or hemodynamic instability. Uncontrolled introperative bleeding occurred in the second case,leading to the operation failure.CONCLUSION:Pure NOTES trans-umbilical cholecystectomy with a water-jet hybrid-knife appears to be feasible and safe. Further investigation of this technique with long-term follow-up in animals is needed to confirm the preliminary observation.展开更多
AIM: To explore the feasibility of a water-jet hybrid knife to facilitate wedge hepatic resection using a natural orifice transluminal endoscopic surgery (NOTES) approach in a non-survival porcine model. METHODS: The ...AIM: To explore the feasibility of a water-jet hybrid knife to facilitate wedge hepatic resection using a natural orifice transluminal endoscopic surgery (NOTES) approach in a non-survival porcine model. METHODS: The Erbe Jet2 water-jet system allows a needleless, tissue-selective hydro-dissection with a pre-selected pressure. Using this system, wedge hepatic resection was performed through three natural routes (trans-anal, trans-vaginal and trans-umbilical) in three female pigs weighing 35 kg under general anesthesia. Entry into the peritoneal cavity was via a 15-mm incision using a hook knife. The targeted liver segment was marked by an APC probe, followed by wedge hepatic resection performed using a water-jet hybrid knife with the aid of a 4-mm transparent distance soft cap mounted onto the tip of the endoscope for holding up the desired plane. The exposed vascular and ductal structures were clipped with Endoclips. Hemostasis was applied to the bleeding cut edges of the liver parenchyma by electrocautery. After the procedure, the incision site was left open, and the animal was euthanized followed by necropsy. RESULTS: Using the Erbe Jet2 water-jet system, trans-anal and trans-vaginal wedge hepatic resection was successfully performed in two pigs without laparoscopic assistance. Trans-umbilical attempt failed due to an unstable operating platform. The incision for peritoneal entry took 1 min, and about 2 h was spent on excision of the liver tissue. The intra-operative blood loss ranged from 100 to 250 mL. Microscopically, the hydro-dissections were relatively precise and gentle, preserving most vessels. CONCLUSION: The Erbe Jet2 water-jet system can safely accomplish non-anatomic wedge hepatic resection in NOTES, which deserves further studies to shorten the dissection time.展开更多
AIM to compare the efficacy and safety of a hook knife(HO) with a hybrid knife(HK) during endoscopic submucosal tunnel dissection(EStD) procedure.METHODS Between August 2012 and December 2015, the ESt D procedure was ...AIM to compare the efficacy and safety of a hook knife(HO) with a hybrid knife(HK) during endoscopic submucosal tunnel dissection(EStD) procedure.METHODS Between August 2012 and December 2015, the ESt D procedure was performed for 83 upper GI submucosal lesions, which originated from the muscularis propria layer identified by upper endoscopy and endoscopic ultrasonography. Of these, 34 lesions were treated by a HO, whereas 49 lesions were treated by a HK. Data regarding age, gender, presenting symptoms, tumor location and size, procedure time, complications, en bloc resection rate and others were analyzed and compared between the two groups.RESULTS there were no significant differences in the age, gender, presenting symptoms and tumor location between the two groups. EStD was successfully completed in all the patients, and no case was converted to laparoscopy. the mean procedure time was significantly shorter in the HK group than in the HO group(41.3 ± 20.3 min vs 57.2 ± 28.0 min, p = 0.004). the mean frequency of device exchange was 1.4 ± 0.6 in the HK group and significantly less than 3.3 ± 0.6 in the HO group(p < 0.001). the differences in tumor size and histopathological diagnoses were not significant between the two groups(p = 0.813, p = 0.363, respectively). Both groups had an equal en bloc resection rate and complete resection rate. Additionally, the complication rate was similar between the two groups(p = 0.901). During the follow-up, no recurrence occurred in either group.CONCLUSION We demonstrate for the first time that HO and HK do not differ in efficacy or safety, but HK reduces the frequency of device exchange and procedure time.展开更多
Hybrid knife as a multi-function endoscopic instrument provides an effective model for endoscopic diagnosis and treatment of diseases. Hybrid knife does not need exchange of instrument during endoscopic operation. It ...Hybrid knife as a multi-function endoscopic instrument provides an effective model for endoscopic diagnosis and treatment of diseases. Hybrid knife does not need exchange of instrument during endoscopic operation. It can effectively reduce the potential risk of perforation and hemorrhage so that improving quality of life for patients. The technology has been widely used in clinic, especially in the treatment of digestive internal medicine, and in the course of respiratory intervention. Researchers have started to use the hybrid knife technique and have obtained good surgical results. In this review, we introduced the advantages of hybrid knife and summarized the clinic application, including the tumor excision and the tissue collection for pathology. Furthermore, the application of hybrid knife has significant implication to gastrointestinal and urinary diseases, and airway tumors, and we also explored the possibility of application of hybrid knife system in more diseases. Hybrid knife system has important clinical significance and is worth further study and exploration.展开更多
文摘AIM:To investigate the feasibility and safety of Natural orifice trans-umbilical endoscopic cholecystectomy with a water-jet hybrid-knife in a non-survival porcine model.METHODS:Pure natural orifice transluminal endoscopic surgery(NOTES) cholecystectomy was performed on three non-survival pigs,by transumbilical approach,using a water-jet hybrid-knife. Under general anesthesia,the following steps detailed the procedure:(1) incision of the umbilicus followed by the passage of a double-channel flexible endsocope through an overtube into the peritoneal cavity;(2) establishment of pneumoperitoneum;(3) abdominal exploration;(4)endoscopic cholecystectomy:dissection of the gallbladder performed using water jet equipment,ligation of the cystic artery and duct conducted using nylon loops;and(5) necropsy with macroscopic evaluation.RESULTS:Transumbilical endoscopic cholecystectomy was successfully completed in the first and third pig,with minor bleedings. The dissection times were 137and 42 min,respectively. The total operation times were 167 and 69 min,respectively. And the lengths of resected specimen were 6.5 and 6.1 cm,respectively.Instillation of the fluid into the gallbladder bed produced edematous,distended tissue making separation safe and easy. Reliable ligation using double nylon loops insured the safety of cutting between the loops.There were no intraoperative complications or hemodynamic instability. Uncontrolled introperative bleeding occurred in the second case,leading to the operation failure.CONCLUSION:Pure NOTES trans-umbilical cholecystectomy with a water-jet hybrid-knife appears to be feasible and safe. Further investigation of this technique with long-term follow-up in animals is needed to confirm the preliminary observation.
文摘AIM: To explore the feasibility of a water-jet hybrid knife to facilitate wedge hepatic resection using a natural orifice transluminal endoscopic surgery (NOTES) approach in a non-survival porcine model. METHODS: The Erbe Jet2 water-jet system allows a needleless, tissue-selective hydro-dissection with a pre-selected pressure. Using this system, wedge hepatic resection was performed through three natural routes (trans-anal, trans-vaginal and trans-umbilical) in three female pigs weighing 35 kg under general anesthesia. Entry into the peritoneal cavity was via a 15-mm incision using a hook knife. The targeted liver segment was marked by an APC probe, followed by wedge hepatic resection performed using a water-jet hybrid knife with the aid of a 4-mm transparent distance soft cap mounted onto the tip of the endoscope for holding up the desired plane. The exposed vascular and ductal structures were clipped with Endoclips. Hemostasis was applied to the bleeding cut edges of the liver parenchyma by electrocautery. After the procedure, the incision site was left open, and the animal was euthanized followed by necropsy. RESULTS: Using the Erbe Jet2 water-jet system, trans-anal and trans-vaginal wedge hepatic resection was successfully performed in two pigs without laparoscopic assistance. Trans-umbilical attempt failed due to an unstable operating platform. The incision for peritoneal entry took 1 min, and about 2 h was spent on excision of the liver tissue. The intra-operative blood loss ranged from 100 to 250 mL. Microscopically, the hydro-dissections were relatively precise and gentle, preserving most vessels. CONCLUSION: The Erbe Jet2 water-jet system can safely accomplish non-anatomic wedge hepatic resection in NOTES, which deserves further studies to shorten the dissection time.
文摘AIM to compare the efficacy and safety of a hook knife(HO) with a hybrid knife(HK) during endoscopic submucosal tunnel dissection(EStD) procedure.METHODS Between August 2012 and December 2015, the ESt D procedure was performed for 83 upper GI submucosal lesions, which originated from the muscularis propria layer identified by upper endoscopy and endoscopic ultrasonography. Of these, 34 lesions were treated by a HO, whereas 49 lesions were treated by a HK. Data regarding age, gender, presenting symptoms, tumor location and size, procedure time, complications, en bloc resection rate and others were analyzed and compared between the two groups.RESULTS there were no significant differences in the age, gender, presenting symptoms and tumor location between the two groups. EStD was successfully completed in all the patients, and no case was converted to laparoscopy. the mean procedure time was significantly shorter in the HK group than in the HO group(41.3 ± 20.3 min vs 57.2 ± 28.0 min, p = 0.004). the mean frequency of device exchange was 1.4 ± 0.6 in the HK group and significantly less than 3.3 ± 0.6 in the HO group(p < 0.001). the differences in tumor size and histopathological diagnoses were not significant between the two groups(p = 0.813, p = 0.363, respectively). Both groups had an equal en bloc resection rate and complete resection rate. Additionally, the complication rate was similar between the two groups(p = 0.901). During the follow-up, no recurrence occurred in either group.CONCLUSION We demonstrate for the first time that HO and HK do not differ in efficacy or safety, but HK reduces the frequency of device exchange and procedure time.
文摘Hybrid knife as a multi-function endoscopic instrument provides an effective model for endoscopic diagnosis and treatment of diseases. Hybrid knife does not need exchange of instrument during endoscopic operation. It can effectively reduce the potential risk of perforation and hemorrhage so that improving quality of life for patients. The technology has been widely used in clinic, especially in the treatment of digestive internal medicine, and in the course of respiratory intervention. Researchers have started to use the hybrid knife technique and have obtained good surgical results. In this review, we introduced the advantages of hybrid knife and summarized the clinic application, including the tumor excision and the tissue collection for pathology. Furthermore, the application of hybrid knife has significant implication to gastrointestinal and urinary diseases, and airway tumors, and we also explored the possibility of application of hybrid knife system in more diseases. Hybrid knife system has important clinical significance and is worth further study and exploration.