期刊文献+
共找到1,042篇文章
< 1 2 53 >
每页显示 20 50 100
Determination of Trace Germanium in Marine Sediments by Hydride Generation-Atomic Fluorescence Spectrometry (HG-AFS) 被引量:2
1
作者 LIJing ZHAOShilan +1 位作者 ZHANGZhaohui ZENGXianjie 《Journal of Ocean University of China》 SCIE CAS 2004年第2期179-182,共4页
A method for the analysis of trace germanium in marine sediments by HG-AFS has been investigated. The experimental conditions such as the acidity of reduction reaction, the amount of sodium boro-hydride, the carrier g... A method for the analysis of trace germanium in marine sediments by HG-AFS has been investigated. The experimental conditions such as the acidity of reduction reaction, the amount of sodium boro-hydride, the carrier gas flow rate, etc., were tested and optimized by using a kind of orthogonal design. The detection limit of the presented method is 0.95 μg L -1 for germanium. The calibration curve shows a satisfactory line in the concentration range 0-320 μg L -1 Ge with a variation coefficient of ±2.1%. 展开更多
关键词 隔代杂交 原子荧光光谱测定法 人工沉降
下载PDF
Determination of Selenium in Marine Aquatic Products by Hydride Generation-atomic Fluorescence Spectrometry (HG-AFS)
2
作者 ZHANG Zhaohui GAO Xin +1 位作者 Tashiro Yuri Hiroo Ogawa 《Journal of Ocean University of China》 SCIE CAS 2005年第3期252-256,共5页
A method for the analysis of selenium in marine aquatic products by HG-AFS has been investigated. The methodis based on the reduction of inorganic selenium to volatile SeH2 which is bubbled out by carrier gas of pure ... A method for the analysis of selenium in marine aquatic products by HG-AFS has been investigated. The methodis based on the reduction of inorganic selenium to volatile SeH2 which is bubbled out by carrier gas of pure argon, and thenswept to Ar-H2 flame quarts atomizer to measure its fluorescence intensity. The hydride generation, transportation, atom-ization and some instrumental parameters were studied by a kind of orthogonal design. The optimum conditions selected areas follows: reactive acidity, 20% HCl; the amount of NaBH4, 4.9mL; gas flow of argon, 600mLmin-1; atomizing tempera-ture, 200 °C; negative high voltage, -300V; light current, 100 mA; integral time, 7s. The detection limit of the presentedmethod is 0.072 μg L-1 for selenium. The calibration curve shows a satisfactory line in the concentration range from 0.000 to1.000 μg L-1 Se. The recovery is 95.8%-102.2% . 展开更多
关键词 水产食品 氢化物 荧光性 光谱测定法
下载PDF
Microwave Digestion Sample Hydride Generation-Atomic Fluorescence Spectrometry Determines Trace Selenium of Mogroside
3
作者 Xiujing Zhang 《International Journal of Technology Management》 2013年第7期128-130,共3页
关键词 原子荧光光谱法 罗汉果皂甙 氢化物发生 微量硒 微波消解 最佳实验条件 共沉淀富集 线性回归方程
下载PDF
Determination of Cadmium in TSP, PM10 in urban areas by hydride generation atomic fluorescence spectrometry
4
作者 LIANG Shu-xuan LI Ling ZHOU Wei-jing LV Tian-feng SUN Han-wen 《Journal of Environmental Science and Engineering》 2007年第1期39-43,54,共6页
关键词 氢化物发生原子荧光光谱法 PM10 测定 氢化物原子荧光光谱法 TSP 市区 可吸入颗粒物
下载PDF
Determination of Hg in soil by ultrasonic slurry sampling hydride generation atomic fluorescence spectrometry
5
作者 LIANG Shu-xuan LV Tian-feng ZHOU Wei-jing SUN Han-wen 《Journal of Environmental Science and Engineering》 2008年第5期9-13,共5页
关键词 原子荧光光谱法 土壤样品 氢化物发生 悬浮液进样 超声波 汞含量 测定 AFS法
下载PDF
Determination of total arsenic by photo-decomposition of organoarsenic compounds and hydride generation electrothermal atomic absorption spectrometry 被引量:4
6
作者 Han Hengbin, Liu Yanbing, Zhang Shuzhen Ni ZhemingResearch Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P. O. Box 2871, Beijing 100085, China 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1993年第1期99-107,共9页
A method was developed for the determination of total arsenic concentration in less than ng/ml level by decomposition of organoarsenicals using photo -oxidation combined with in situ trapping of arsenic hydride on a p... A method was developed for the determination of total arsenic concentration in less than ng/ml level by decomposition of organoarsenicals using photo -oxidation combined with in situ trapping of arsenic hydride on a palladium coated graphite tube with subsequent atomization and detection by AAS. The organoarsenicals include monomethylarsenic, dimethylarsenic, arsenobetaine, arsenocholine, o -aminobenzenarsenate and p -aminobenzenarsenate. The method is simple and sensitive. Detection limit was obtained from different arsenic compounds over the range from 0. 058 to 0.063 ng/ml as As (based on three times of the standard deviation of 10 blank measurements) and the relative standard deviations for ten replicate measurements were from 2.0 to 3.8%. The calibration curves of arsenic compounds including inorganic and organic arsenicals were linear over the range from 0.1 to 3.0 ng/ml as As. The recommended method has been applied to the determination of total arsenic in tap and lake water samples at ng/ml levels. 展开更多
关键词 electrothermal atomic absorption spectrometry photo -decomposition organoarsenic compounds arsenic hydride generation tap/lake water
下载PDF
DETERMINATION OF ANTIMONY IN WATER SAMPLES BY FLOW-INJECTION HYDRIDE GENERATION ATOMIC ABSORPTION SPECTROMETRY WITH ON-LINE ION-EXCHANGE COLUMN PRECONCENTRATION
7
作者 Shu Kun XU and Zhao Lun FANG Institute of Applied Ecology, Academia Sinica, Shenyang, 110015 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第11期915-918,共4页
On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(... On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(Ⅲ) was preconcentrated on a micro-column packed with CPG-8Q chelating ion-exchanger using time-based sample loading and eluted by 4 mol l^(-1) HCl directly into the hydride generation AAS system. A detection limit (3σ) of 0.0015μg l^(-1) Sb(Ⅲ) was obtained on the basis of a 20 fold enrichment and with a sampling frequency of 60h^(-1). The precision was 1.0% r.s.d.(n=11) at the 0.5μg l^(-1) Sb(Ⅲ) level. Recoveries for the analysis of antimony in tap water, snow water and sea water samples were in the range 97-102%. 展开更多
关键词 Zhang DETERMINATION OF ANTIMONY IN WATER SAMPLES BY FLOW-INJECTION hydride generation atomic ABSORPTION spectrometry WITH ON-LINE ION-EXCHANGE COLUMN PRECONCENTRATION SQ CPG ION LINE
下载PDF
高效液相色谱-氢化物发生-原子荧光光谱法测定富硒大豆中硒代氨基酸的含量 被引量:1
8
作者 卢鑫 张琳 +1 位作者 王铁良 周晓华 《理化检验(化学分册)》 CAS CSCD 北大核心 2024年第3期288-293,共6页
取0.1 g脱脂后富硒大豆样品于离心管中,用5 mL pH 7.5的130 mmol·L^(-1)三(羟甲基)氨基甲烷-盐酸缓冲液超声振荡30 min,用15 mg链霉蛋白酶于37℃振荡酶解5 h,离心后取上清液,过0.22μm尼龙有机滤膜。滤液中的硒代半胱氨酸(SeCys)... 取0.1 g脱脂后富硒大豆样品于离心管中,用5 mL pH 7.5的130 mmol·L^(-1)三(羟甲基)氨基甲烷-盐酸缓冲液超声振荡30 min,用15 mg链霉蛋白酶于37℃振荡酶解5 h,离心后取上清液,过0.22μm尼龙有机滤膜。滤液中的硒代半胱氨酸(SeCys)、硒代蛋氨酸(SeMet)、甲基硒代半胱氨酸(MeSeCys)在Agela MP-C_(18)色谱柱上分离,以含2%(体积分数)甲醇和0.5 mmol·L^(-1)四丁基溴化铵的40 mmol·L^(-1)磷酸氢二铵溶液(pH 7.0)进行等度洗脱,并采用氢化物发生-原子荧光光谱法测定3种硒代氨基酸的含量。结果表明,3种硒代氨基酸在7 min内可以实现基线分离,标准曲线的线性范围均为5~100μg·L^(-1),检出限依次为0.086,0.075,0.047 mg·kg^(-1)。按照标准加入法进行回收试验,回收率为85.5%~103%,测定值的相对标准偏差(n=7)不大于3.0%。方法用于分析富硒大豆中的硒代氨基酸,大豆中硒赋存形态多为SeMet,含量占总硒量的85.5%~94.5%。 展开更多
关键词 高效液相色谱-氢化物发生-原子荧光光谱法(HPLC-HG-AFS) 大豆 硒代氨基酸 硒形态
下载PDF
氢化物发生-原子荧光光谱法(HG-AFS)测达里诺尔湖流域底泥样硒
9
作者 薛舒文 苏丹 +2 位作者 张嘉璇 张营 徐苏男 《科技创新与应用》 2024年第15期83-86,共4页
氢化物发生-原子荧光光谱法(HG-AFS)是测定硒(Selenium,Se)的理想方法,能精确测定水样和含水地球化学样品(底泥)中Se的含量。由于达里湖底泥中Se含量相对较低,有机质的还原状态较高,在测量Se含量时往往因为过于复杂且低于仪器检出限而... 氢化物发生-原子荧光光谱法(HG-AFS)是测定硒(Selenium,Se)的理想方法,能精确测定水样和含水地球化学样品(底泥)中Se的含量。由于达里湖底泥中Se含量相对较低,有机质的还原状态较高,在测量Se含量时往往因为过于复杂且低于仪器检出限而不能被检测到有效值。该文应用HG-AFS测定达里诺尔湖底泥中Se的含量,使用微波消解石墨赶酸作为前处理方法,并使用HG-AFS进行Se含量的测试,采用此法测定底泥中Se元素具有快速、准确、重现性好,被确定为一种快速可靠的对底泥样品Se含量进行测定的方法。 展开更多
关键词 湖泊底泥 氢化物发生-原子荧光光谱法 微波消解 测定
下载PDF
吡咯烷二硫代氨基甲酸铵螯合-浊点萃取-氢化物发生原子荧光光谱法测定饮用水中痕量汞
10
作者 刘景龙 韩倩 杨超 《理化检验(化学分册)》 CAS CSCD 北大核心 2024年第6期570-575,共6页
鉴于标准HJ 694—2014检测饮用水中汞的检出限较高,无法满足痕量汞的分析要求,提出以吡咯烷二硫代氨基甲酸铵(APDC)溶液为螯合剂,以非离子型表面活性剂Triton X-114溶液为萃取剂,通过浊点萃取的方式将饮用水中的痕量汞富集于表面活性剂... 鉴于标准HJ 694—2014检测饮用水中汞的检出限较高,无法满足痕量汞的分析要求,提出以吡咯烷二硫代氨基甲酸铵(APDC)溶液为螯合剂,以非离子型表面活性剂Triton X-114溶液为萃取剂,通过浊点萃取的方式将饮用水中的痕量汞富集于表面活性剂相,采用氢化物发生原子荧光光谱法测定痕量汞的方法。水样经过滤、酸化后,分取50 mL水样,加入2.0 g·L^(−1)APDC溶液1.5 mL,5%(体积分数)Triton X-114溶液1.5 mL,调节混合溶液酸度至pH 6,于40℃平衡5 min,以2900 r·min^(−1)转速离心10 min,冰水浴中冷却5~10 min。弃去上层水相,在表面活性剂相中加入由磷酸三丁酯与乙醇按体积比1∶1混合配制的消泡剂300μL,用5%(体积分数)盐酸溶液稀释至5 mL,上机检测。结果显示:汞的质量浓度在2.0μg·L^(−1)以内和对应的荧光强度呈线性关系,检出限为0.002μg·L^(−1)。按标准加入法进行回收试验,回收率为86.8%~97.9%,测定值的相对标准偏差(n=6)不大于8.0%。方法检出限较标准HJ 694—2014低一个数量级,能够满足饮用水等清洁水样中痕量汞分析的检出限要求。 展开更多
关键词 浊点萃取 螯合剂 氢化物发生原子荧光光谱法 预富集
下载PDF
Determination of Inorganic Arsenic Species by Electrochemical Hydride Generation Atomic Absorption Spectrometry with Selective Electrochemical Reduction 被引量:1
11
作者 李勋 汪正浩 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2007年第3期295-299,共5页
A new direct procedure for the determination of inorganic arsenic species was developed by electrochemical hydride generation atomic absorption spectrometry (EcHG-AAS) with selective electrochemical reduction. The d... A new direct procedure for the determination of inorganic arsenic species was developed by electrochemical hydride generation atomic absorption spectrometry (EcHG-AAS) with selective electrochemical reduction. The determination of inorganic arsenic species is based on the fact that As(Ⅲ) shows significantly higher absorbance at low electrolytic currents than As(Ⅴ) in 0.3 mol·L^-1 H2SO4. The electrolytic current used for the determination of As(Ⅲ) without considerable interferences of As(Ⅴ) was 0.4 A, whereas the current for the determination of As(Ⅲ) and As(Ⅴ) was 1.2 A. For equal concentrations of As(Ⅲ) and As(Ⅴ) in a sample, the interferences of As(Ⅴ) during the As(Ⅲ) determination were smaller than 5%. The absorbance for As(Ⅴ) could be calculated by subtracting that for As(Ⅲ) measured at 0.4 A from the total absorbance for As(Ⅲ) and As(Ⅴ) measured at 1.2 A, and then the concentration of As(Ⅴ) can be obtained by its calibration curve at 1.2 A. The methodology developed provided the detection limits of 0.3 and 0.6 ng·mL^-1 for As(Ⅲ) and As(Ⅴ), respectively. The relative standard deviations were of 3.5% for 20 ng·mL^-1 As(Ⅲ) and 3.2% for 20 ng·mL^-1 As(Ⅴ). The method was successfully applied to determination of soluble inorganic arsenic species in Chinese medicine. 展开更多
关键词 electrochemical hydride generation atomic absorption spectrometry inorganic arsenic species
原文传递
高压密闭消解-氢化物发生原子荧光光谱法测定农作物中硒的含量
12
作者 李艳华 于亚辉 +5 位作者 曹立峰 刘春霞 钟盼 杜峥 吴娣 杜文娟 《理化检验(化学分册)》 CAS CSCD 北大核心 2023年第6期690-694,共5页
提出了高压密闭消解-氢化物发生原子荧光光谱法测定农作物中硒含量的方法。粮食类样品(干样)去除杂物后,用水洗净,于60℃烘干;蔬菜类样品(鲜样)用水洗净,晾干,取可食用部分,制成匀浆。取上述样品0.5000 g置于高压密闭聚四氟乙烯(PTFE)... 提出了高压密闭消解-氢化物发生原子荧光光谱法测定农作物中硒含量的方法。粮食类样品(干样)去除杂物后,用水洗净,于60℃烘干;蔬菜类样品(鲜样)用水洗净,晾干,取可食用部分,制成匀浆。取上述样品0.5000 g置于高压密闭聚四氟乙烯(PTFE)内罐中,加入8 mL硝酸和2 mL 30%(质量分数)过氧化氢溶液,混匀过夜,于150℃密封消解4 h。冷却至室温后,于150℃赶酸至约1 mL,加入50%(体积分数)盐酸溶液5 mL,于150℃继续保持加热至溶液无色清亮并伴有白烟冒出。冷却后转移至10 mL容量瓶中,加入100 g·L^(-1)铁氰化钾溶液2.5 mL,用水定容。所得溶液在硒高性能空心阴极灯电流为80 mA,载气流量为300 mL·min^(-1),屏蔽气流量为700 mL·min^(-1)的条件下,采用氢化物发生原子荧光光谱法测定其中硒的含量。结果表明,硒的质量浓度在100μg·L^(-1)以内与对应的荧光强度呈线性关系,检出限(3s)为0.001 mg·kg^(-1)。方法用于国家标准物质分析,测定值的相对标准偏差(n=12)为2.3%~7.1%,相对误差为-6.7%~9.7%。方法还用于实际样品分析,所得测定结果与国家标准GB 5009.93-2017基本一致。 展开更多
关键词 高压密闭消解 氢化物发生原子荧光光谱法 农作物
下载PDF
液相色谱-氢化物发生-原子荧光光谱法测定中药样品中的4种砷形态
13
作者 张雯 徐丽 +1 位作者 刘德晔 张琳昀 《食品与药品》 CAS 2023年第6期514-519,共6页
目的 建立一种液相色谱-氢化物发生-原子荧光光谱测定中药样品中4种砷形态的方法。方法 以0.15 mol/L硝酸溶液为提取溶剂,提取处理后的中药样品,全自动石墨消解仪90℃热浸提,离心,取上清,0.45μm滤膜过滤后注入液相色谱仪,梯度洗脱,4种... 目的 建立一种液相色谱-氢化物发生-原子荧光光谱测定中药样品中4种砷形态的方法。方法 以0.15 mol/L硝酸溶液为提取溶剂,提取处理后的中药样品,全自动石墨消解仪90℃热浸提,离心,取上清,0.45μm滤膜过滤后注入液相色谱仪,梯度洗脱,4种砷形态可在360 s中内完全分离,分离后的亚砷酸根[As(Ⅲ)]、砷酸根[As(Ⅴ)]、一甲基砷(MMA)、二甲基砷(DMA)4种砷形态进入氢化物发生-原子荧光光谱仪进行检测,根据保留时间定性,峰面积定量。结果 本方法在1.0~50.0μg/L范围内线性良好,相关系数(r)均>0.999,加标回收率为96.7%~101.9%,不同浓度水平的RSD均小于3%。所检测的7种中药材样品中,砷主要以As(Ⅲ)和As(Ⅴ)形态存在。结论 本方法前处理简便、检测速度快、检出限低、准确度和精密度较高,可用于中药材样品中4种砷形态的测定。 展开更多
关键词 中药 液相色谱-氢化物发生-原子荧光光谱法 砷形态 As(Ⅲ) As(Ⅴ) 一甲基砷(MMA) 二甲基砷(DMA)
下载PDF
氢化物发生-原子荧光光谱法测定钨尾矿尾砂中的砷 被引量:1
14
作者 陈祝炳 唐碧玉 +1 位作者 曾志平 施意华 《中国无机分析化学》 CAS 北大核心 2023年第10期1054-1058,共5页
钨尾矿尾砂中的砷会随着自然条件的变化或资源综合利用过程而发生迁移,污染存在扩大的风险,快速、准确测定钨尾矿尾砂中砷的含量,将为环境污染防治措施提供数据依据。采用盐酸、硝酸消解样品,加入硫酸消除钨对原子荧光光谱法测定砷的干... 钨尾矿尾砂中的砷会随着自然条件的变化或资源综合利用过程而发生迁移,污染存在扩大的风险,快速、准确测定钨尾矿尾砂中砷的含量,将为环境污染防治措施提供数据依据。采用盐酸、硝酸消解样品,加入硫酸消除钨对原子荧光光谱法测定砷的干扰,用抗坏血酸将砷(Ⅴ)预还原为砷(Ⅲ),在盐酸介质中,砷(Ⅲ)和硼氢化钾发生氢化反应生成砷化氢,经载气导入原子化器中测定砷量,并优化原子荧光光谱法测定条件,建立了氢化物发生原子荧光光谱法测定钨尾矿尾砂中砷的分析方法。砷的测定结果相对标准偏差(RSD,n=7)小于3%,加标回收率为93.9%~111%,同时采用钨含量与钨尾矿中钨含量相近的钨矿石成分分析标准物质做方法正确度验证,相对误差的绝对值<5%。实验结果表明,建立的方法测定钨尾矿尾砂中砷含量,具有操作简单、灵敏度高,干扰少、正确度高,测定速度快等优点。 展开更多
关键词 钨尾矿尾砂 氢化物发生-原子荧光光谱法
下载PDF
水浴消解-原子荧光光度法测定土壤中的总砷和总汞 被引量:1
15
作者 田翠 金伟 +4 位作者 刘霜 张维娜 郑海芳 罗小娇 张强 《云南化工》 CAS 2023年第9期72-75,共4页
研究土壤中总砷和总汞的测定方法,样品采用王水消解,建立了水浴消解-原子荧光光度法测定土壤中总砷和总汞的方法。总砷的的检出限为0.70μg/kg,总汞的检出限为4.52μg/kg,总砷的的精密度是1.10%~1.73%,总汞的精密度1.20%~3.43%,总砷的... 研究土壤中总砷和总汞的测定方法,样品采用王水消解,建立了水浴消解-原子荧光光度法测定土壤中总砷和总汞的方法。总砷的的检出限为0.70μg/kg,总汞的检出限为4.52μg/kg,总砷的的精密度是1.10%~1.73%,总汞的精密度1.20%~3.43%,总砷的回收率为91%~103%;总汞的回收率为103%~106%。该方法检出限、精密度、准确度、回收率均能满足土壤检测的要求,且前处理简单、快捷、高效,适用于土壤中总砷总汞的同时测定。 展开更多
关键词 土壤 氢化物原子荧光光度法 总砷 总汞 王水
下载PDF
基于外管进样增强信号技术的氢化物发生-原子荧光光谱法测定食品中铅和镉的含量
16
作者 贺攀红 杨珍 +2 位作者 马琳 杨有泽 肖国原 《理化检验(化学分册)》 CAS CSCD 北大核心 2023年第11期1249-1255,共7页
考虑到市售氢化物发生-原子荧光光谱仪载气由石英原子化器内管载入,载气流量较小(300~600 mL·min^(-1),测定铅和镉),产生的铅、镉荧光强度较小,因此改造了此仪器的石英原子化器中载气和辅助气的流路,将内管进样改为外管进样,同时... 考虑到市售氢化物发生-原子荧光光谱仪载气由石英原子化器内管载入,载气流量较小(300~600 mL·min^(-1),测定铅和镉),产生的铅、镉荧光强度较小,因此改造了此仪器的石英原子化器中载气和辅助气的流路,将内管进样改为外管进样,同时优化了助剂及载流,并进行了方法学验证。样品经酸溶液处理后,用改造的氢化物发生-原子荧光光谱仪分析。结果显示:相较于内管进样,外管进样可将载气流量提升至1000~1400 mL·min^(-1),载带的氢化气更多,氢化气和氢气混合气能更快地与石英套管上端的加热炉丝接触而点燃;内管输入辅助气(氩气),会将氢火焰焰炬向上适度抬升,形成的焰炬更稳定,体积也更大。以铁氰化钾和镉增敏剂作助剂,可以显著增强铅、镉荧光强度;以水替代传统稀酸作载流,交替进样时试验空白中铅、镉荧光强度的相对标准偏差(RSD,n=7)均小于3.0%,适用于小批量样品检测;铅、镉标准曲线的线性范围分别在10.00μg·L-1和0.50μg·L-1以内,检出限(3s/k)分别为3.5μg·kg-1(膨化食品中铅)和0.74μg·kg-1(大米中镉)。铅、镉灵敏度(标准曲线斜率k)分别是文献报道同类方法的1.3~13倍和2.8~99倍。按照标准加入法进行回收试验,回收率为86.0%~118%,测定值的RSD(n=6)为2.6%~5.8%。 展开更多
关键词 氢化物发生-原子荧光光谱法 外管进样 信号增强 载流
下载PDF
湿法消解-氢化物原子荧光光谱法测定小米中硒含量
17
作者 赵芳 《食品安全导刊》 2023年第23期81-83,共3页
目的:建立湿法消解-氢化物原子荧光光谱法测定小米中硒含量的分析方法。方法:小米试样经混合酸消解后,加入(1+1)盐酸溶液还原,使用原子荧光光谱仪在线检测。结果:硒在0~20.0μg·L^(-1)线性良好,相关系数为0.9997,方法检出限为0.000... 目的:建立湿法消解-氢化物原子荧光光谱法测定小米中硒含量的分析方法。方法:小米试样经混合酸消解后,加入(1+1)盐酸溶液还原,使用原子荧光光谱仪在线检测。结果:硒在0~20.0μg·L^(-1)线性良好,相关系数为0.9997,方法检出限为0.0002 mg·kg^(-1),加标回收率为95.0%~104.8%,相对标准偏差为3.20%~3.92%。结论:本方法灵敏度高,准确高,检测周期短,可操作性强,适用于大批量小米样品中硒含量的分析检测。 展开更多
关键词 湿法消解-氢化物原子荧光光谱法 小米 硒含量
下载PDF
微波消解-氢化物原子荧光法测定高含量硒的工艺探究
18
作者 李涛 王碧军 王芳梅 《现代食品》 2023年第1期53-56,共4页
本文采用微波消解-氢化物原子荧光法测定高含量硒。用硒含量作为评价指标进行单因素和正交试验,确定最优处理条件。结果表明,当称样量为0.10 g、消解温度为200℃、消解液配比为11 mL硝酸+1 mL双氧水,盐酸添加量为6 mL和定容体积为500 mL... 本文采用微波消解-氢化物原子荧光法测定高含量硒。用硒含量作为评价指标进行单因素和正交试验,确定最优处理条件。结果表明,当称样量为0.10 g、消解温度为200℃、消解液配比为11 mL硝酸+1 mL双氧水,盐酸添加量为6 mL和定容体积为500 mL时,测定的硒含量为122.78 mg·kg^(-1),且加标回收率高,试验稳定性好。 展开更多
关键词 微波消解 氢化物原子荧光法 富硒片 高含量硒
下载PDF
氢化物发生-原子荧光光谱法测定中草药中的硒 被引量:59
19
作者 杨莉丽 张德强 +3 位作者 高英 苑春刚 张艳欣 孙汉文 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2003年第2期368-370,共3页
本文建立了氢化物发生-原子荧光光谱法测定中草药中的微量硒的分析方法。研究了仪器的工作条件、试剂对硒原子荧光强度的影响及硒(Ⅵ)的还原条件,探讨了共存离子对硒测定的干扰和消除方法,方法的检出限为0.21μg·L^(-1)。利用本方... 本文建立了氢化物发生-原子荧光光谱法测定中草药中的微量硒的分析方法。研究了仪器的工作条件、试剂对硒原子荧光强度的影响及硒(Ⅵ)的还原条件,探讨了共存离子对硒测定的干扰和消除方法,方法的检出限为0.21μg·L^(-1)。利用本方法成功地测定了10种中草药中的微量硒,回收率为95%~105%。方法简便、快速、灵敏、准确。 展开更多
关键词 氢化物发生 原子荧光光谱法 测定 中草药 分析
下载PDF
氢化物发生-原子荧光光谱法测定植物样品中的硒 被引量:56
20
作者 苟体忠 唐文华 +2 位作者 张文华 刘少友 吴林冬 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2012年第5期1401-1404,共4页
建立了氢化物发生-原子荧光光谱法测定植物样品中硒的分析方法。研究了试剂及预还原方式对硒原子荧光强度的影响,探讨了共存离子对硒测定的影响和消除方法。在最佳消解条件和测定条件下,硒的线性回归方程为I=139.98c+27.71,线性范围为0... 建立了氢化物发生-原子荧光光谱法测定植物样品中硒的分析方法。研究了试剂及预还原方式对硒原子荧光强度的影响,探讨了共存离子对硒测定的影响和消除方法。在最佳消解条件和测定条件下,硒的线性回归方程为I=139.98c+27.71,线性范围为0~10ng.mL-1,相关系数为1.000 0,检出限为1.45ng.g-1。测定标准物质中硒的回收率为98.9%~101%,其平均值为100%。对灌木枝叶样品中的硒进行分析,其相对标准偏差为0.73%(n=9)。以国家标准物质(GSV-1)为监控样品,测定值与标准值吻合。该方法具有成本低、操作简单和高效分析的优点,并成功用于植物样品中硒的测定。 展开更多
关键词 氢化物发生 原子荧光光谱 植物
下载PDF
上一页 1 2 53 下一页 到第