期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Long-term rotational stability and visual outcomes of a single-piece hydrophilic acrylic toric IOL:a 1.5-year follow-up 被引量:7
1
作者 Balázs Gyongyossy Paul Jirak Ulrich Schonherr 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第4期573-578,共6页
AIM:To evaluate the rotational stability and visual outcomes of a single-piece hydrophilic acrylic toric intraocular lenses(IOL) over a 1.5-year follow-up period.Data from the 6-month follow-up study have been prev... AIM:To evaluate the rotational stability and visual outcomes of a single-piece hydrophilic acrylic toric intraocular lenses(IOL) over a 1.5-year follow-up period.Data from the 6-month follow-up study have been previously reported.METHODS:Forty eyes of 26 cataract patients(mean age:72.8±7.9y) with pre-existing corneal astigmatism of 1.0 to 2.6 D were enrolled in the study.Mean axial length was 23.17±0.88 mm.Main outcome measures after implantation of the Torica-a A IOL(Human Optics) were IOL rotational stability,subjective refraction,astigmatism correction,uncorrected and corrected distance visual acuity(UDVA,CDVA).RESULTS:There was no significant change in the parameters evaluated between the 6-month and 1.5-year follow-ups.At last visit,mean absolute IOL rotation(objective method) was 1.81°±1.87°(range 0.00° to 7.20°) with 78.6% of eyes having IOL rotation 〈3°,92.9% of eyes 〈5° and 100% of eyes 〈8°.No patient required secondary IOL repositioning during the course of the study.Mean residual refractive cylinder was-0.60±0.40 D.There was a significant reduction in the magnitude of the J0 vector postoperatively(P〈0.0001) with a mean absolute change of 0.76±0.40 D.The mean J45 vector was close to zero preoperatively and postoperatively and didn't change significantly(P=0.28).Mean monocular UDVA and CDVA was 0.09±0.12 log MAR and-0.01±0.12 log MAR,respectively.No treatment with Nd:YAG laser was required.CONCLUSION:The Torica-a A IOL shows good and stable visual performance and rotational stability over a 1.5-year follow-up period. 展开更多
关键词 hydrophilic acrylic ASTIGMATISM intraocular lenses CATARACT rotational stability
下载PDF
Hydrophobic versus hydrophilic acrylic intraocular lens on posterior capsule opacification: a Meta-analysis 被引量:1
2
作者 Qiong Wu Yan Li +1 位作者 Lian Wu Cong-Yi Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第6期997-1004,共8页
AIM: To conduct a Meta-analysis pooling randomized controlled trials(RCTs) to compare hydrophobic with hydrophilic acrylic intraocular lenses in terms of posterior capsule opacification(PCO) development.METHODS: Elect... AIM: To conduct a Meta-analysis pooling randomized controlled trials(RCTs) to compare hydrophobic with hydrophilic acrylic intraocular lenses in terms of posterior capsule opacification(PCO) development.METHODS: Electronic databases including PubMed,Embase, and the Cochrane Library were queried from their starting till January 2020. RCTs investigating the impact of hydrophobic versus hydrophilic acrylic intraocular lenses on PCO were considered eligible in this study. The pooled effect estimates were calculated using the random-effects model.RESULTS: Thirteen RCTs comprising of 939 patients(1263 eyes) were covered in this study. Patients with hydrophobic acrylic intraocular lenses had a lower PCO score than those with a hydrophilic acrylic intraocular lenses [standard mean difference:-1.80;95% confidence interval(CI):-2.62 to-0.98;P<0.001]. Moreover, the frequency of neodymium-doped yttrium aluminum garnet(Nd:YAG)capsulotomy in patients with hydrophobic acrylic intraocular lenses was significantly lower than patients with hydrophilic acrylic intraocular lenses(relative risk: 0.38;95%CI: 0.20-0.71;P=0.003).CONCLUSION: These findings suggest that hydrophobic acrylic intraocular lenses are superior to hydrophilic acrylic intraocular lenses in patients after cataract surgery due to lower PCO score and reduced Nd:YAG capsulotomy. While similar studies are conducted by other researchers, the present study conducted subgroup analyses that show superior results with hydrophobic lenses in trials conducted in western countries. 展开更多
关键词 hydrophobic acrylic intraocular lens hydrophilic acrylic intraocular lens posterior cataract opacification Nd:YAG capsulotomy META-ANALYSIS
下载PDF
Severe prelenticular membrane formation on the surface of a hydrophilic acrylic intraocular lens after cataract surgery in an eye with an Ahmed valve implant 被引量:1
3
作者 Yong-Sun Ahn Jin A Choi 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第2期430-432,共3页
【正】Dear Sir,Iam Yong-Sun Ahn,from the Department of Ophthalmology of St.Vincent Hospital of Suwon,Kyungki-do,South Korea.Cataracts are a common problem in eyes with a glaucoma drainage device(GDD),because tube shun... 【正】Dear Sir,Iam Yong-Sun Ahn,from the Department of Ophthalmology of St.Vincent Hospital of Suwon,Kyungki-do,South Korea.Cataracts are a common problem in eyes with a glaucoma drainage device(GDD),because tube shunt surgery increases the incidence and progression of cataracts[1].An Ahmed valve,the most commonly inserted GDD,is composed of a silicone tube connected to a flat plate sewn to the sclera,and aqueous humor flows from the 展开更多
关键词 IOL Severe prelenticular membrane formation on the surface of a hydrophilic acrylic intraocular lens after cataract surgery in an eye with an Ahmed valve implant body Figure
下载PDF
Comparison of posterior capsule opacification at 360-degree square edge hydrophilic and sharp edge hydrophobic acrylic intraocular lens in diabetic patients 被引量:3
4
作者 Ling Bai Jin Zhang +2 位作者 Ling Chen Ting Ma Hou-Cheng Liang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第4期725-729,共5页
·AIM: To compare posterior capsule opacification(PCO)degree and visual functions after phacoemulsification in eyes implanted with 360-degree square edge hydrophilic acrylic intraocular lens(IOL)(570C C-flex, Rayn... ·AIM: To compare posterior capsule opacification(PCO)degree and visual functions after phacoemulsification in eyes implanted with 360-degree square edge hydrophilic acrylic intraocular lens(IOL)(570C C-flex, Rayner) and sharp edge hydrophobic acrylic IOL(Sensar AR40 e,AMO) in diabetic patients.· METHODS: Sixty diabetic patients underwent uneventful phacoemulsification and randomly implanted one of the two IOLs. The PCO value was measured by retroillumination photographs and Evaluation of Posterior Capsule Opacification(EPCO) 2000 image-analysis software at 1, 6, 12, and 24 mo after surgery. Visual acuity, and contrast sensitivity in photopic and mesopic conditions were also examined at each follow up time point. The incidence of eye that required Nd:YAG laser posterior capsulotomy were also compared.·RESULTS: There was not any statistically significant difference in PCO scores between Rayner C-flex 570 C group and Sensar AR40 e group at each follow up time point. Visual acuity, Nd:YAG capsulotomy incidence and contrast sensitivity also had no significant difference during the 24 mo follow-up.·CONCLUSION: For diabetic patients, Rayner 570 C Cflex and Sensar AR40 e IOLs are same effective for prevent PCO. The 360-degree square edge design maybe is a good alternative technique to improve PCO prevention. 展开更多
关键词 hydrophilic acrylic intraocular lens posterior capsule opacification visual functions diabetic patients
下载PDF
The Behavior of New Hydrophilic Composite Bone Cements for Immediate Loading of Dental Implant 被引量:1
5
作者 马毅慧 WANG Ruoli +2 位作者 程祥荣 LIU Zhilan ZHANG Yufeng 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2013年第3期627-633,共7页
We introduced the hydrophilic groups to acrylic bone cement to improve compliance and achieve more interdigitation between the bone and the acrylic bone cement in order to create better substrates for immediate loadin... We introduced the hydrophilic groups to acrylic bone cement to improve compliance and achieve more interdigitation between the bone and the acrylic bone cement in order to create better substrates for immediate loading. FTIR-ATR, contact angle, and maximum breach torque were employed for measurement. The results reveal that the introduction of hydrophilic functional groups has increased PMMA's surface hydrophilicity after contact angle test. FTIR-ATR results suggest the hydrophilic groups participate in the polymerization reactions, and maximum breach torque of the hydrophilic acrylic bone cements is near 110 Ncm torque. Those effects make it possible for conventional acrylic bone cement application in immediate loading of dental implant. 展开更多
关键词 immediate loading hydrophilic acrylic bone cement tooth implant
下载PDF
Effects of Hydrophilic Monomer Types and Level on Polystyrene-Acrylate/montmorillonite Nanocomposite Made by Emulsion Polymerization 被引量:3
6
作者 F.A.Zhang L.Chen +1 位作者 J.Q.Ma X.Yang 《复旦学报(自然科学版)》 CAS CSCD 北大核心 2007年第5期754-,共1页
1 Results Nanocomposite has attracted more and more interest all over the world.Polystyrene (PS) is a commercialized and mass-productive polymer,continuous research efforts have been devoted to the development of poly... 1 Results Nanocomposite has attracted more and more interest all over the world.Polystyrene (PS) is a commercialized and mass-productive polymer,continuous research efforts have been devoted to the development of polystyrene/montmorillonite (PS/MMT) nanocomposites[1-2].But the polarity of styrene (St) is too small to intercalate the space between the clay layers.The polarity of hydrophilic monomer is so strong that it can intercalate the MMT easily,the intercalated smectic clays maybe exfoliated by usin... 展开更多
关键词 nanocomposites STYRENE hydrophilic acrylate monomer clay thermal properties
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部