期刊文献+
共找到110篇文章
< 1 2 6 >
每页显示 20 50 100
Energy Storage System for Solar Thermal Air Conditioning Combined with Ejector Cooling System
1
作者 Sarayooth Vaivudh 《Journal of Energy and Power Engineering》 2015年第2期179-184,共6页
A system of energy storage for solar thermal air conditioning combined with ejector cooling system for residential is determined in this paper. The purpose of this study is to design the energy storage system for heat... A system of energy storage for solar thermal air conditioning combined with ejector cooling system for residential is determined in this paper. The purpose of this study is to design the energy storage system for heating the water in a storage tank to reach the required temperature for exchanging heat with the refrigerant of cooling system. The design from calculation of thermal energy storage system that proper with the solar flat plate collector area results are 70 m2, and the hot water temperature is over than 80 ℃. A cooling system is selected for refrigerant of R141b from the solar air conditioning system of 10.5 kW, and the energy source is solar thermal energy from the collector that there is an efficiency of 0.46 approximately. This storage system for the electric solar cooling system can be reduced the problem of the intermittent of energy source with the constant generating temperature to run the cooling system continuously. 展开更多
关键词 Energy storage system solar thermal air conditioning ejector cooling system.
下载PDF
基于蓄热装置辅助的燃料电池电动车供暖系统动态仿真 被引量:1
2
作者 宋泽华 陈浩 +2 位作者 郭航 叶芳 张惟博 《汽车安全与节能学报》 CAS CSCD 北大核心 2024年第1期54-62,共9页
为了辅助燃料电池车辆预热,提升燃料电池在低温下的冷启动速率以及降低电动车能耗,该文提出了一种基于热泵和蓄热装置联合的燃料电池电动车供暖方案,并开展了燃料电池车辆系统动态仿真研究,对比了有无蓄热装置辅助的系统对车辆运行过程... 为了辅助燃料电池车辆预热,提升燃料电池在低温下的冷启动速率以及降低电动车能耗,该文提出了一种基于热泵和蓄热装置联合的燃料电池电动车供暖方案,并开展了燃料电池车辆系统动态仿真研究,对比了有无蓄热装置辅助的系统对车辆运行过程的影响。结果表明:在寒冷运行环境下,蓄热装置可确保驾驶循环工况下循环冷却液热量来源的连续性,相较于无蓄热装置的热管理系统,热泵和蓄热联合供暖方案可使空调系统能耗下降26%;利用蓄热装置辅助的供暖系统能够改善燃料电池电动车的冬季冷启动特性,优化车辆电池系统的热管理。 展开更多
关键词 燃料电池 电动车 热泵空调 蓄热 冷启动
下载PDF
基于室内设定温度调节的办公建筑空调用能柔性特性实验分析
3
作者 张修宇 王丹 +3 位作者 王伟 吕燕捷 范朋丹 孙育英 《暖通空调》 2024年第10期18-26,70,共10页
空调系统作为建筑需求响应的核心,具有较大的柔性潜力。为了实现需求响应效益的最大化,针对性地实施优化配置与调控,必须明确空调用能柔性特性。然而,现有研究多依赖于模拟仿真探究需求响应期间的空调用能柔性特性,该方法往往无法准确... 空调系统作为建筑需求响应的核心,具有较大的柔性潜力。为了实现需求响应效益的最大化,针对性地实施优化配置与调控,必须明确空调用能柔性特性。然而,现有研究多依赖于模拟仿真探究需求响应期间的空调用能柔性特性,该方法往往无法准确反映实际运行条件,导致柔性特性不明晰,进而造成调控不合理、效率低等问题。针对以上问题,本研究选取2栋办公建筑进行了不同工况的需求响应实验,基于温变速率与预计平均热感觉指数(PMV)指标分析了设定温度调节期间的室内舒适度,并以柔性量、柔性比分析了不同工况下空调柔性可调潜力区间;同时,通过蓄热体内表面温度研究需求响应期间建筑蓄热体柔性特征。实测结果表明:在需求响应期间,当设定温度调节1~2℃时,均可维持较好的室内舒适度;同时,需求响应期间2栋建筑能够提供10~20 W/m^(2)的柔性负荷量,可实现28.3%~83.1%的负荷转移。本文结果可为空调系统柔性量化提供指标支撑与实测依据,对“双碳”目标下的建筑节能有参考价值。 展开更多
关键词 办公建筑 空调系统 柔性负荷 需求响应 温度调节 室内热舒适 建筑蓄热体
下载PDF
冷热双向全周期维度蓄能空调系统设计优化
4
作者 周科 李锦堂 +5 位作者 张广秋 谈竹奎 王扬 孙宗宇 李骥 肖小兵 《建筑节能(中英文)》 CAS 2024年第9期42-49,共8页
蓄能空调系统涉及“源”侧电力供应和“荷”侧建筑冷热需求双重动态变化特性,系统的容量配置是一个技术经济寻优问题。受室内外多种因素共同影响,建筑冷热负荷每天的逐时分布规律差别较大,传统上仅基于设计日等典型周期逐时负荷分布规... 蓄能空调系统涉及“源”侧电力供应和“荷”侧建筑冷热需求双重动态变化特性,系统的容量配置是一个技术经济寻优问题。受室内外多种因素共同影响,建筑冷热负荷每天的逐时分布规律差别较大,传统上仅基于设计日等典型周期逐时负荷分布规律的设计方法使得蓄能空调系统容量的配置不合理。突破传统设计方法的不足,提出以空调系统全年运行性能为导向的冷热双向全周期维度蓄能空调系统性能化设计方法,能够考虑到全供暖季、全制冷季每天的逐时动态负荷分布规律,耦合建筑冷热负荷双向需求,获得更加科学合理的蓄能空调系统容量配置方案。用具体案例进行了设计方法展示。 展开更多
关键词 蓄能空调系统 冷热负荷双重需求 全年逐时动态负荷 性能化设计 设计日
下载PDF
相变蓄热材料用于热泵空调强化除霜理论研究
5
作者 付梦婷 包睿祺 +1 位作者 赵汀 沈九兵 《制冷与空调》 2024年第9期15-21,共7页
家用热泵型空调器在除霜模式下缺少低位热源,且无法实现室内的持续供暖,文章针对以上的问题,在原有热泵系统基础上增设相变蓄热换热器,提出了一种多功能相变蓄热空调系统,并基于能量守恒原理,利用制冷剂压焓图、湿空气焓湿图对该系统的... 家用热泵型空调器在除霜模式下缺少低位热源,且无法实现室内的持续供暖,文章针对以上的问题,在原有热泵系统基础上增设相变蓄热换热器,提出了一种多功能相变蓄热空调系统,并基于能量守恒原理,利用制冷剂压焓图、湿空气焓湿图对该系统的过冷蓄热模式、供暖除霜模式进行了初步理论分析。进一步选取了多种相变蓄热材料,并通过在10~25℃范围内改变系统的蒸发温度来表征不同蓄热材料应用时的相变温度,进而通过理论计算研究不同蓄热材料相变温度下除霜时间、系统能效比的变化,为相变蓄热材料的选取提供理论依据。分析表明,随着材料的相变温度升高,压缩机功率下降幅度明显,除霜功率线性增加,COP值从5.7上升至8.9,除霜时间较传统模式缩短约80%。 展开更多
关键词 空气调节器 蓄热 除霜 相变温度 能效比
下载PDF
Cool storage time of phase change wallboard room in summer 被引量:1
6
作者 冯国会 陈其针 +2 位作者 黄凯良 牛润萍 王琳 《Journal of Central South University》 SCIE EI CAS 2009年第S1期75-79,共5页
More and more attention was paid to phase change energy storage in air conditioning domain and construction energy conservation,and became the focus of the international research. Through the test and analysis of the ... More and more attention was paid to phase change energy storage in air conditioning domain and construction energy conservation,and became the focus of the international research. Through the test and analysis of the parameters of the indoor thermal property in phase change wallboard room and ordinary room,the effects of using phase change wallboards on indoor temperature in summer and air conditioning are obtained. The combination of construct enclosure and phase change materials can stabilize indoor temperature,improve indoor thermal comfort,reduce the frequency of the operation of air conditioning facility,cut the initial investment and operation expense,and meanwhile play an practical role in "the power balancing between the peak period and the valley period" policy. Through the experiment and the test of the effects exerted by phase change wallboard room and ordinary room on the indoor thermal environment,it is obtained that the phase change wallboard can reduce the fluctuation range of indoor temperature and the heat flow from the outside into indoor environment in summer. According to the study,it is found that the effect of cool-storing for 5 h is obvious. Through the analysis of the phase change wallboard without air conditioning in daytime,it is obtained that the frequency of the operation of air conditioning in phase change wallboard room is smaller than that in the ordinary room,which can prolong the lifetime of the facility and reduce operation expense. 展开更多
关键词 PHASE CHANGE energy storage PHASE CHANGE WALLBOARD room thermal storage thermal exchange cool-storage air-conditioning
下载PDF
Design of Heat Storage for a Solar Concentrator Driving an Absorption Chiller
7
作者 M. A. Serag-Eldin 《Engineering(科研)》 2013年第1期107-116,共10页
The feasibility of employing stand-alone solar energy systems to meet demand-side loads depends strongly on providing appropriate solar energy storage. The present paper presents an efficient and economical, undergrou... The feasibility of employing stand-alone solar energy systems to meet demand-side loads depends strongly on providing appropriate solar energy storage. The present paper presents an efficient and economical, underground, thermal storage design to store hot water at a temperature of around 180?C required for running a double effect absorption chiller to cool a zero-energy-house in a desert environment. The performance of the design is evaluated employing a specially developed efficient mathematical model, for simulating the steady state radiation, convection and conduction processes occurring within the storage unit. The model is presented and analyzed, and employed to investigate the effects of various design parameters on storage efficiency. It is demonstrated that high storage efficiency may be reached, providing that appropriate insulation materials are used. It is also revealed that the soil conductivity has little effect on storage efficiency. 展开更多
关键词 thermal ENERGY storage HOT Water storage SOLAR ENERGY SOLAR air-conditioning Green BUILDINGS
下载PDF
基于全年逐时动态仿真的蓄能空调系统容量优化配置分析 被引量:2
8
作者 李锦堂 孙宗宇 +5 位作者 杜思存 孔维政 李骥 冯晓梅 焦玉婷 朱超 《暖通空调》 2023年第5期51-58,共8页
开发了蓄能空调系统逐时动态仿真工具。该仿真工具根据项目全年逐时冷热负荷、运行策略、预设的空调系统配置方案等条件,能自动进行系统全年逐时动态仿真,对蓄能空调系统运行性能、系统效益的量化评估由以往的夏季、冬季设计日等典型周... 开发了蓄能空调系统逐时动态仿真工具。该仿真工具根据项目全年逐时冷热负荷、运行策略、预设的空调系统配置方案等条件,能自动进行系统全年逐时动态仿真,对蓄能空调系统运行性能、系统效益的量化评估由以往的夏季、冬季设计日等典型周期扩展至全年365个真实周期,冷热负荷逐时分布规律选取由以往的特殊周期优化至项目全年逐时动态冷热负荷,计算方式更加合理、客观。以某实际工程设计为例,进行了蓄能空调系统容量配置优化分析。 展开更多
关键词 蓄能空调系统 全年逐时动态仿真 容量配置优化 移峰填谷 “源-储-荷”协同控制
下载PDF
集中空调系统需求响应潜力分析 被引量:1
9
作者 张鑫洋 孟庆龙 +3 位作者 李辉 韦应安 姜乐 赵凡 《电力需求侧管理》 2023年第6期57-62,共6页
利用供暖、通风和空调系统与建筑的耦合热惰性提供需求响应资源是一种经济实用的方法,尤其是具有主动储能系统的建筑物,具有更大的需求响应潜能。首先搭建仿真平台并验证了其准确性,然后从建筑和空调的被动储能以及蓄热罐的主动储能两... 利用供暖、通风和空调系统与建筑的耦合热惰性提供需求响应资源是一种经济实用的方法,尤其是具有主动储能系统的建筑物,具有更大的需求响应潜能。首先搭建仿真平台并验证了其准确性,然后从建筑和空调的被动储能以及蓄热罐的主动储能两个方面进行研究,采用了预冷、温度重置以及启停制冷机组3种策略的灵活组合,分析了建筑和空调系统、蓄热罐的需求响应潜力。结果表明,该策略对于短期(0.5h)和长期(2.5h)的需求响应均有效:对于短期需求响应计划,利用建筑和空调系统本身的热惰性就可以满足;对于长期需求响应计划,需用到主动储能技术满足室内热舒适要求。 展开更多
关键词 需求响应 暖通空调 建筑热惰性 主动储能
下载PDF
不同建筑面积下冷热双蓄空调系统的运行费用
10
作者 顾昊 汪俊超 《自动化应用》 2023年第10期206-207,222,共3页
本文以江苏省南京市建筑面积为2×10^(4)m^(2)和1×10^(5)m^(2)的写字楼办公建筑为研究对象,研究地源热泵+冷水机组+水冷热双蓄和冷水机组冰蓄冷+电锅炉水蓄热两种技术路线配置方案的运行成本。结果表明,蓄能空调系统的运行成... 本文以江苏省南京市建筑面积为2×10^(4)m^(2)和1×10^(5)m^(2)的写字楼办公建筑为研究对象,研究地源热泵+冷水机组+水冷热双蓄和冷水机组冰蓄冷+电锅炉水蓄热两种技术路线配置方案的运行成本。结果表明,蓄能空调系统的运行成本与主机容量、效率和水泵等其他辅助设备容量密切相关;地源热泵+冷水机组+水冷热双蓄配置方案的运行成本低于相同情况下电锅炉水蓄热+冷水机组冰蓄冷。 展开更多
关键词 蓄能空调 地源热泵 冷水机组 电锅炉 运行成本
下载PDF
我国不同气候地区夏季相变墙房间热性能模拟和评价 被引量:52
11
作者 林坤平 张寅平 江亿 《太阳能学报》 EI CAS CSCD 北大核心 2003年第1期46-52,共7页
利用我们提出的分析相变墙房间热性能的理论模型 ,并藉该文献提出的两个评价房间夏季过热不舒适程度指标———“累计日室内温度不舒适度”IDCT和“累计日室内综合温度不舒适度”IDC,分析了采用相变墙建筑适用的气候条件 ,并通过数值方... 利用我们提出的分析相变墙房间热性能的理论模型 ,并藉该文献提出的两个评价房间夏季过热不舒适程度指标———“累计日室内温度不舒适度”IDCT和“累计日室内综合温度不舒适度”IDC,分析了采用相变墙建筑适用的气候条件 ,并通过数值方法模拟和评价了相变墙房间在我国不同气候地区的使用效果 ,说明了相变墙建筑在我国不同地区使用的优点和局限性。 展开更多
关键词 相变墙 夜间通风 储能 空调 建筑节能
下载PDF
蓄冷率与冰蓄冷空调经济性诸因素的关系 被引量:20
12
作者 胡鸣若 余国和 顾安忠 《上海理工大学学报》 CAS 北大核心 2002年第2期113-117,121,共6页
建立了冰蓄冷空调系统经济性分析的数学模型,以一个实例详细分析了蓄冷率与冰蓄冷空调经济性诸因素的关系,提出了蓄冷率的选取范围.
关键词 冰蓄冷空调 经济性分析 蓄冷率
下载PDF
空调用纳米有机复合相变蓄冷材料制备与热物性 被引量:21
13
作者 武卫东 唐恒博 +1 位作者 苗朋柯 张华 《化工学报》 EI CAS CSCD 北大核心 2015年第3期1208-1214,共7页
针对目前空调用有机相变蓄冷材料热导率低的问题,将具有高导热性的纳米材料(MWNTs、Al2O3、Fe2O3)添加到所开发制备的二元复合有机蓄冷材料(质量比73.7:26.3的辛酸/肉豆蔻醇)中,从纳米材料的种类和浓度两方面,研究其对复合有机蓄冷材料... 针对目前空调用有机相变蓄冷材料热导率低的问题,将具有高导热性的纳米材料(MWNTs、Al2O3、Fe2O3)添加到所开发制备的二元复合有机蓄冷材料(质量比73.7:26.3的辛酸/肉豆蔻醇)中,从纳米材料的种类和浓度两方面,研究其对复合有机蓄冷材料热物性的影响。实验发现:对于MWNTs、Al2O3、Fe2O3 3种纳米材料,当其质量分数分别小于0.3%、0.4%、0.8%时,对应纳米复合材料热导率随纳米材料浓度的增加幅度较为明显;与原二元复合有机相变蓄冷材料相比,添加0.3%的MWNTs,热导率提高26.3%;添加0.4%的Al2O3,热导率提高13.1%;添加0.8%的Fe2O3,热导率提高32.1%;当在一定纳米材料质量分数(如0.7%)下,加入纳米颗粒的复合材料导热性能效果依次为Fe2O3>MWNTs>Al2O3。不同纳米粒子的添加对原蓄冷材料的相变温度和相变潜热影响很小,相变温度变化波动最大为0.4℃,相变潜热变化波动范围最大为1.4%。 展开更多
关键词 有机相变材料 空调蓄冷 纳米材料 热物性 强化传热 热传导 制备
下载PDF
相变材料式蓄冷空调系统的经济性分析 被引量:6
14
作者 李晓燕 张健 +1 位作者 高宇航 邱美苓 《哈尔滨商业大学学报(自然科学版)》 CAS 2009年第5期607-610,共4页
针对新型PCM蓄冷空调系统的经济性进行了研究,建立了PCM蓄冷空调系统的经济性分析模型,并利用该模型对冰蓄冷空调,常规集中空调进行了比较;分析结果表明,PCM蓄冷空调系统初投资较高,但运行费用最低,且静态回收期最短,可见相变材料蓄冷... 针对新型PCM蓄冷空调系统的经济性进行了研究,建立了PCM蓄冷空调系统的经济性分析模型,并利用该模型对冰蓄冷空调,常规集中空调进行了比较;分析结果表明,PCM蓄冷空调系统初投资较高,但运行费用最低,且静态回收期最短,可见相变材料蓄冷技术有着广泛的应用前景. 展开更多
关键词 相变蓄冷 经济性分析 空调系统 模型
下载PDF
空调蓄冷材料热性能实验研究 被引量:7
15
作者 方贵银 徐锡斌 李辉 《制冷学报》 CAS CSCD 北大核心 2004年第2期25-29,共5页
通过实验研究了空调蓄冷材料的凝固温度、融解温度、凝固潜热和融解潜热等热学性能。该蓄冷材料是由两种相变材料构成。在热性能测试中 ,用示差扫描量热仪来测定蓄冷材料的潜热 ,用红外光谱仪来测定蓄冷材料的结构变化。该蓄冷材料的融... 通过实验研究了空调蓄冷材料的凝固温度、融解温度、凝固潜热和融解潜热等热学性能。该蓄冷材料是由两种相变材料构成。在热性能测试中 ,用示差扫描量热仪来测定蓄冷材料的潜热 ,用红外光谱仪来测定蓄冷材料的结构变化。该蓄冷材料的融解热是 1 1 8.996kJ/kg、起始融解温度是 6 .399℃。其热容量比一般的无机水合盐大、融解温度比冰高。 展开更多
关键词 空调 蓄冷材料 热学性能 示差扫描量热仪
下载PDF
水蓄冷空调系统设计及经济性分析 被引量:17
16
作者 王峥 王建 《华北电力大学学报(自然科学版)》 CAS 北大核心 2007年第2期130-133,共4页
以一幢建筑面积约4.5×104m2的商务楼的空调系统为研究对象,在分析设计日逐时冷负荷图的基础上,提出水蓄冷空调系统设计方案和运行策略,并与常规空调系统进行了经济性分析和比较。研究表明水蓄冷空调具有显著的经济效益和社会效益。
关键词 水蓄冷 设计 经济性分析 空调
下载PDF
季节性含水层储能系统在住宅中的应用 被引量:3
17
作者 付峥嵘 李念平 +1 位作者 汤广发 龚光彩 《暖通空调》 北大核心 2004年第9期84-86,75,共4页
提出一种含水层储能的住宅集中空调系统。在分析含水层储能的数学模型及其离散算法的基础上 ,编制了计算机模拟程序 ,利用该程序对影响含水层储能效果的若干因素进行了模拟计算 ,认为集中回灌比分散回灌效果好 ;在回灌热量一定的情况下 ... 提出一种含水层储能的住宅集中空调系统。在分析含水层储能的数学模型及其离散算法的基础上 ,编制了计算机模拟程序 ,利用该程序对影响含水层储能效果的若干因素进行了模拟计算 ,认为集中回灌比分散回灌效果好 ;在回灌热量一定的情况下 ,小流量大温差运行效果较好 ;地质条件对系统热效率和抽水温差有影响。 展开更多
关键词 住宅 大温差 集中空调系统 回灌 含水层 基础 编制 效果 影响 季节性
下载PDF
干工况风机盘管加冰蓄冷新风系统空调过程研究 被引量:9
18
作者 周俊凯 周伟坤 陈国邦 《低温与超导》 CAS CSCD 北大核心 2003年第2期57-59,共3页
采用冰蓄冷装置作为新风系统处理机组 ( AHU )的冷源 ,结合设计实例 ,提出了干工况风机盘管加冰蓄冷新风系统空调设计方案 ,并就冰蓄冷新风系统 ( AHU )及风机盘管末端 ( FCU )的选择作一些探讨。
关键词 夏季 空调 过程设计 干工况 风机盘管 加冰蓄冷新风系统
下载PDF
空调用二元有机相变蓄冷材料的理论预测与研究 被引量:6
19
作者 唐恒博 武卫东 +1 位作者 苗朋柯 张华 《化工新型材料》 CAS CSCD 北大核心 2016年第3期121-123,126,共4页
有机相变材料在空调蓄冷中的应用是今后一个重要的发展方向,选取壬酸、辛酸、癸酸、月桂酸、正癸醇、月桂醇和肉豆蔻醇7种有机物质作为研究对象,两两组合,根据热力学第二定律和相平衡理论,预测出不同比例二元混合材料中的相变温度和相... 有机相变材料在空调蓄冷中的应用是今后一个重要的发展方向,选取壬酸、辛酸、癸酸、月桂酸、正癸醇、月桂醇和肉豆蔻醇7种有机物质作为研究对象,两两组合,根据热力学第二定律和相平衡理论,预测出不同比例二元混合材料中的相变温度和相变潜热。通过DSC测试各组样品的热物性,制备筛选出适用于空调场合使用的二元有机相变蓄冷材料。结果表明:辛酸/月桂醇、癸酸/月桂醇和辛酸/肉豆蔻醇3组二元混合材料的相变温度范围为5~9℃,相变潜热范围为145~172kJ/kg,符合空调蓄冷要求;上述混合体系中辛酸/肉豆蔻醇(质量比73.7∶26.3)样品的性能最好,其相变温度为6.9℃,相变潜热为169.1kJ/kg。 展开更多
关键词 相变 有机化合物 空调蓄冷 热物性 潜热
下载PDF
空调蓄冷材料研究现状及其新进展 被引量:7
20
作者 方贵银 李辉 《低温与超导》 CAS CSCD 北大核心 2003年第3期64-67,共4页
分析了空调蓄冷材料研究现状及存在的一些问题 ,提出研制一种新型空调复合蓄冷材料 ,通过实验 ,分析该蓄冷材料的融点、融解热等热学性能。并通过实验研究寻找到了一种新型空调蓄冷材料 ,测试结果表明该蓄冷材料具有较高的相变潜热、适... 分析了空调蓄冷材料研究现状及存在的一些问题 ,提出研制一种新型空调复合蓄冷材料 ,通过实验 ,分析该蓄冷材料的融点、融解热等热学性能。并通过实验研究寻找到了一种新型空调蓄冷材料 ,测试结果表明该蓄冷材料具有较高的相变潜热、适宜的相变温度和较好的热稳定性 ,因此可被应用于蓄冷空调系统中。 展开更多
关键词 空调蓄冷材料 水蓄冷 冰蓄冷 共晶盐蓄冷 共晶盐蓄冷 气体水合物蓄冷
下载PDF
上一页 1 2 6 下一页 到第