Ray tracing Particle Image Velocimetry(RT-PIV)is an optical technique for high resolution velocity measurements in challenging optical systems,such as transparent packed beds,that uses ray tracing to correct for disto...Ray tracing Particle Image Velocimetry(RT-PIV)is an optical technique for high resolution velocity measurements in challenging optical systems,such as transparent packed beds,that uses ray tracing to correct for distortions introduced by transparent geometries in the light paths.The ray tracing based correction is a post processing step applied to the raw PIV particle images before classical PIV evaluation.In this study,RT-PIV is performed in the top layer of a body centred cubic(bcc)sphere packing with gaseous flow,where optical access is obtained by the use of transparent N-BK7 glass balls with a diameter of d=40 mm.RT-PIV introduces new experimental and numerical challenges,for example a limited field of view,illumination difficulties,a very large required depth of field and high sensitivity to geometric parameters used in the ray tracing correction.These challenges and their implications are the main scope and discussed in the present work.Further,the validation of the ray tracing reconstruction step is presented and examples for the obtained corrected vector fields in a packed bed are given.The results show the strength of the method in reconstructing velocity fields behind transparent spheres that would not have been accessible by optical measurement techniques without the ray tracing correction.展开更多
基金funded by the Deutsche Forschungsgemeinschaft(DFG,German Research Foundation)-Project-ID 422037413-TRR 287.Peter Kovats and our student Zahin Thamed are acknowledged for their help during experiments.
文摘Ray tracing Particle Image Velocimetry(RT-PIV)is an optical technique for high resolution velocity measurements in challenging optical systems,such as transparent packed beds,that uses ray tracing to correct for distortions introduced by transparent geometries in the light paths.The ray tracing based correction is a post processing step applied to the raw PIV particle images before classical PIV evaluation.In this study,RT-PIV is performed in the top layer of a body centred cubic(bcc)sphere packing with gaseous flow,where optical access is obtained by the use of transparent N-BK7 glass balls with a diameter of d=40 mm.RT-PIV introduces new experimental and numerical challenges,for example a limited field of view,illumination difficulties,a very large required depth of field and high sensitivity to geometric parameters used in the ray tracing correction.These challenges and their implications are the main scope and discussed in the present work.Further,the validation of the ray tracing reconstruction step is presented and examples for the obtained corrected vector fields in a packed bed are given.The results show the strength of the method in reconstructing velocity fields behind transparent spheres that would not have been accessible by optical measurement techniques without the ray tracing correction.