Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has bee...Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has been established that facilitates microwave imaging reflectometry and electron cyclotron emission imaging.This platform utilizes plasma profiles as input and incorporates the finite-difference time domain,ray tracing and the radiative transfer equation to calculate the propagation of plasma spontaneous radiation and the external electromagnetic field in plasmas.Benchmark tests for classical cases have been conducted to verify the accuracy of every core module in the GSD platform.Finally,2D imaging of a typical electron temperature distribution is reproduced by this platform and the results are consistent with the given real experimental data.This platform also has the potential to be extended to 3D electromagnetic field simulations and other microwave diagnostics such as cross-polarization scattering.展开更多
An upgraded electron cyclotron emission imaging (ECEI) system consisting of new optics lenses with necessary electronics for receiving and processing signals for two dimension (2D) ECEI diagnostics was installed o...An upgraded electron cyclotron emission imaging (ECEI) system consisting of new optics lenses with necessary electronics for receiving and processing signals for two dimension (2D) ECEI diagnostics was installed on EAST. Hyperboloid lens were adopted in the new system to optimize the spatial resolutions. The mixers array of sixteen elements measured the plasma electron cyclotron emission at eight frequencies simultaneously, and the profiles of the electron temperature and its fluctuation in an area of 20 cm (vertical) × 6 cm (horizontal) could then be analyzed. Evolution of sawtooth precursor and crash in EAST was observed.展开更多
Imaging systems in nature have attracted a lot of research interest due to their superior optical and imaging characteristics, Recent advancements in materials science, mechanics, and stretchable electronics have led ...Imaging systems in nature have attracted a lot of research interest due to their superior optical and imaging characteristics, Recent advancements in materials science, mechanics, and stretchable electronics have led to successful development of bioinspired cameras that resemble the structures and functions of biological light-sensing organs. In this review, we discuss some recent progresses in mechanics of bioinspired imaging systems, including tunable hemispherical eyeball camera and artificial compound eye camera. The mechanics models and results reviewed in this article can provide efficient tools for design and optimization of such systems, as well as other related optoelectronic systems that combine rigid elements with soft substrates.展开更多
The fluctuation of the electron temperature has been measured by using the electron cyclotron emission imaging in the Hefei Tokamak-7 (HT-7) plasma. The electron temperature fluctuation with a broadband spectrum sho...The fluctuation of the electron temperature has been measured by using the electron cyclotron emission imaging in the Hefei Tokamak-7 (HT-7) plasma. The electron temperature fluctuation with a broadband spectrum shows that it propagates in the electron diamagnetic drift direction, and the mean poloidal wave-number kθ is calculated to be about 1.58cm^-1, or k^-θρs ≈ 0.34. It indicates that the fluctuation should come from the electron drift wave turbulence. The linear global scaling of the electron temperature fluctuation with the gradient of electron temperature is consistent with the mixing length scale qualitatively. Evolution of spectrum of the fluctuation during the sawtooth oscillation phases is investigated, and the fluctuation is found to increase with the gradient of electron temperature increasing during most phases of the sawtooth oscillation. The results indicate that the electron temperature gradient is probably the driver of the fluctuation enhancement. The steady heat flux driven by electron temperature fluctuation is estimated and compared with the results from power balance estimation.展开更多
The principle, imaging condition and experimental method for obtaining high resolution composition contrast in secondary electron image were described. A new technique of specimen preparation for secondary electron co...The principle, imaging condition and experimental method for obtaining high resolution composition contrast in secondary electron image were described. A new technique of specimen preparation for secondary electron composition contrast observation was introduced and discussed. By using multilayer P+Si1-xGex/pSi heterojunction internal photoemission infrared detector as an example, the applications of secondary electron composition contrast imaging in microstructure studies on heterojunction semiconducting materials and devices were stated. The characteristics of the image were compared with the ordinary transmission electron diffraction contrast image. The prospects of applications of the imaging method in heterojunction semiconductor devices and multilayer materials are also discussed.展开更多
At the first stage of the electron cyclotron emission imaging (ECEI) diagnostic project on HT-7, a 16-channel vertical-resolved ECEI diagnostic has been developed and installed on HT-7 tokamak to measure electron cy...At the first stage of the electron cyclotron emission imaging (ECEI) diagnostic project on HT-7, a 16-channel vertical-resolved ECEI diagnostic has been developed and installed on HT-7 tokamak to measure electron cyclotron emission with a temporal resolution of 0.5 usec. The system works at a fixed frequency of 97.5 GHz. The sample volumes of the system are aligned vertically with a vertical channel spacing of 11 mm, and can be shifted across the plasma cross-section by varying the toroidal magnetic field. The high spatial resolution of the system is achieved by utilizing a low-cost linear mixer/receiver array and an optical imaging system. The focus location may be shifted horizontally when translating one of the optical imaging elements. The details of the system design and laboratory testing of the ECEI optics are presented together with the preliminary experimental results.展开更多
The m/n = 1/1 and its higher harmonic modes are observed in sawtooth oscillations by using the novel high- resolution 2D ECE imaging system on the experimental advanced superconducting Tokamak (EAST). Higher harmoni...The m/n = 1/1 and its higher harmonic modes are observed in sawtooth oscillations by using the novel high- resolution 2D ECE imaging system on the experimental advanced superconducting Tokamak (EAST). Higher harmonic modes are appearing for a short time during the crash phase of sawtooth oscillation in lower βp plasma, which is not the preferabie position in the poloidal cross section. These modes generate sharp pressure points on the inversion radius during the crash phase of sawtooth oscillation. Furthermore, reconnection events proceed in two distinctive phases. In the first phase, a small amount of heat is expelled through the weak reconnection while in the second phase the remaining large quantity of heat and particles emerged rapidly from the hot core to the peripheral region of the inversion radius. In addition, these harmonic modes are only found before and after the ICRF pulse, while in the ICRF pulse only the (1,1) mode exists in the sawtooth oscillation.展开更多
We report direct nanoscale imaging of ultrafast plasmon in a gold dolmen nanostructure excited with the 7is laser pulses by combining the interferometric time-resolved technology with the three-photon photoemission el...We report direct nanoscale imaging of ultrafast plasmon in a gold dolmen nanostructure excited with the 7is laser pulses by combining the interferometric time-resolved technology with the three-photon photoemission electron microscopy (PEEM). The interferometric time-resolved traces show that the plasmon mode beating pattern appears at the ends of the dimer slabs in the dolmen nanostructure as a result of coherent superposition of multiple localized surface plasmon modes induced by broad bandwidth of the ultrafast laser pulses. The PEEM measurement further discloses that in-phase of the oscillation field of two neighbor defects are surprisingly observed, which is attributed to the plasmon coupling between them. Furthermore, the control of the temporal delay between the pump and probe laser pluses could be utilized for manipulation of the near-field distribution. These findings deepen our understanding of ultrafast plasmon dynamics in a complex nanosystem.展开更多
Using a scanning electron microscope (SEM) in the back-scattered electron (BSE) mode the composition of multi-element specimens may be determined based on the strong dependence of emission coefficient η on the averag...Using a scanning electron microscope (SEM) in the back-scattered electron (BSE) mode the composition of multi-element specimens may be determined based on the strong dependence of emission coefficient η on the average atomic number of elements Z. The output video signal of the usual BSE detectors is produced from their sensors, and the larger proportion of high-energy electrons with modified spectrum is added. Since η = is/ip (is and ip currents of specimen and probe), better accuracy must be achieved by direct measurements those currents on the specimen surface. Here, an experimental model of a current detector for a presented specimen is described. The cage is mounted on the carousel of the moving specimen stage. The input of the preamplifier is connected to the specimen holder in the form of a disk, the diameter of which is 12 mm. When the probe along its surface scanned, the input potential begins to pulsate with a negative polarity. The output of this preamplifier is connected to a small light-emitting diode, which creates intensity-modulated radiation in the chamber. Thus created the light video signal will be picked up by the photomultiplier of the E-T detector. The modes of true SE and BSE are set by applying tens bias volts of various polarities to the specimens or the cage itself.展开更多
A new robust electronic image stabilization system is presented, which involves feature-point, tracking based global motion estimation and Kalman filtering based motion compensation. First, global motion is estimated ...A new robust electronic image stabilization system is presented, which involves feature-point, tracking based global motion estimation and Kalman filtering based motion compensation. First, global motion is estimated from the local motions of selected feature points. Considering the local moving objects or the inevitable mismatch, the matching validation, based on the stable relative distance between the points set is proposed, thus maintaining high accuracy and robustness. Next, the global motion parameters are accumulated for correction by Kalman filteration. The experimental result illustrates that the proposed system is effective to stabilize translational, rotational, and zooming jitter and robust to local motions.展开更多
Currently,the 65Mn steel is quenched mainly by oil media.Even though the lower cooling rate of oil compared to water reduces the hardness of steel post quenching,the deforming and cracking of parts are often minimized...Currently,the 65Mn steel is quenched mainly by oil media.Even though the lower cooling rate of oil compared to water reduces the hardness of steel post quenching,the deforming and cracking of parts are often minimized.On the other hand,the oil media also has the disadvantage of being ammable,creating smoke that adversely affects the media.The poly alkylene glycol(PAG)polymer quenchant is commonly used for quenching a variety of steels based on its advantages such as non-ammability and exible cooling rate subjected to varying concentration and stirring speed.This article examines the effect of PAG polymer quenching solution(with concentrations of 10%and 20%)on deformation,hardness,and microstructure of C-ring samples made of 65Mn steel.Furthermore,the performance of PAG polymer quenchant is also compared with those of two common quenching solutions:Water and oil.When cooling in water,the C-ring samples had the largest deformation and 2 times higher than the results obtained when a 10%PAG solution was used.In particular,similar levels of deformation on the C-ring samples were observed in both cases of 20%PAG solution and oil as the primary quenching media.Furthermore,the hardness level measured between the sampled parts quenched in the 20%PAG solution appeared to be more uniform than that obtained from the oil-quenched sample.The study of the microscopic structure of steel by optical microscopy combined with X-ray diffraction showed that the water hardened sample exhibited cracks and comprised of two phases,martensite and retained austenite.According to the results of Electron Back Scattering Diffraction(EBSD)analysis and backscattering electronic image(BSE),the content of austenite residue in the sample when the sample was cooled in PAG 10 and 20%solution was 3.21%and 4.73%,respectively and smaller than the measurements obtained from oil quenching solution.Thus,the 65Mn steel is cooled in 20%PAG solution for high hardness and more evenly distributed than when it is quenched in oil while still ensuring a small level of deformation.Therefore,the PAG 20%solution can completely replace oil as the main media used to quench the 65Mn steel.展开更多
The influences of hydrogen on the mechanical properties and the fracture behaviour of Fe-22Mn-0.6C twinning induced plasticity steel have been investigated by slow strain rate tests and fractographic analysis.The stee...The influences of hydrogen on the mechanical properties and the fracture behaviour of Fe-22Mn-0.6C twinning induced plasticity steel have been investigated by slow strain rate tests and fractographic analysis.The steel showed high susceptibility to hydrogen embrittlement,which led to 62.9%and 74.2%reduction in engineering strain with 3.1 and 14.4 ppm diffusive hydrogen,respectively.The fracture surfaces revealed a transition from ductile to brittle dominated fracture modes with the rising hydrogen contents.The underlying deformation and fracture mechanisms were further exploited by examining the hydrogen effects on the dislocation substructure,stacking fault probability,and twinning behaviour in pre-strained slow strain rate test specimens and notched tensile specimens using coupled electron channelling contrast imaging and electron backscatter diffraction techniques.The results reveal that the addition of hydrogen promotes planar dislocation structures,earlier nucleation of stacking faults,and deformation twinning within those grains which have tensile axis orientations close to<111>//rolling direction and<112>//rolling direction.The developed twin lamellae result in strain localization and micro-voids at grain boundaries and eventually lead to grain boundary decohesion.展开更多
Digital image stabilization technique plays important roles in video surveillance and object acquisition.Many useful electronic image stabilization algorithms have been studied.A real-time algorithm is proposed based ...Digital image stabilization technique plays important roles in video surveillance and object acquisition.Many useful electronic image stabilization algorithms have been studied.A real-time algorithm is proposed based on field image gray projection which enables the regional odd and even field image to be projected into x and y directions and thus to get the regional gray projection curves in x and y directions,respectively.For the odd field image channel,motion parameters can be estimated via iterative minimum absolute difference based on two successive field image regional gray projection curves.Then motion compensations can be obtained after using the Kalman filter method.Finally,the odd field image is adjusted according to the compensations.In the mean time,motion compensation is applied to the even field image channel with the odd field image gray projection curves of the current frame.By minimizing absolute difference between odd and even field image gray projection curves of the current frame,the inter-field motion parameters can be estimated.Therefore,the even field image can be adjusted by combining the inter-field motion parameters and the odd field compensations.Finally,the stabilized image sequence can be obtained by synthesizing the adjusted odd and even field images.Experimental results show that the proposed algorithm can run in real-time and have a good stabilization performance.In addition,image blurring can be improved.展开更多
Noise,vibration and harshness(NVH)problems in vehicle engineering are always challenging in both traditional vehicles and intelligent vehicles.Although high accuracy manufacturing,modern structural roads and advanced ...Noise,vibration and harshness(NVH)problems in vehicle engineering are always challenging in both traditional vehicles and intelligent vehicles.Although high accuracy manufacturing,modern structural roads and advanced suspension technology have already significantly reduced NVH problems and their impacts;off-road condition,obstacles and extreme operating condition could still trigger NVH problems unexpectedly.This paper proposes a vehicular electronic image stabilization(EIS)system to solve the vibration problem of the camera and ensure the environment perceptive function of vehicles.Firstly,feature point detection and matching based on an oriented FAST and rotated BRIEF(ORB)algorithm are implemented to match images in the process of EIS.Furthermore,a novel improved random sampling consensus algorithm(i-RANSAC)is proposed to eliminate mismatched feature points and increase the matching accuracy significantly.And an adaptive Kalman filter(AKF)is applied to improve the adaptability of the vehicular EIS.Finally,an experimental platform based on a gasoline model car was established to validate its performance.The experimental results show that the proposed EIS system can satisfy vehicular performance requirements even under off-road condition with obvious obstacles.展开更多
The coarse pore system, interfacial transition zone (ITZ) between aggregate and paste matrix and volume fraction of unhydrated cement in concrete (w/c=0.3) containing mineral admixtures were quantitatively charact...The coarse pore system, interfacial transition zone (ITZ) between aggregate and paste matrix and volume fraction of unhydrated cement in concrete (w/c=0.3) containing mineral admixtures were quantitatively characterized by the scanning electron microscope-backscattered electron (SEM-BSE) image analysis technique. The experimental results show that compound addition of slag and fly ash decreases the coarse porosity from 10.17% to 3.74% and the threshold diameter of coarse pore size from 345 μm to 105 μm compared with concrete (w/c=0.30) without mineral admixtures; Moreover with compound addition of fly ash and slag, the volume proportion of unhydrated cement in paste matrix is reduced by 30%, the maximum amount of coarse pores in the ITZ between aggregate and paste decreases from 13.11% to 5.57% and the thickness of ITZ is reduced by 37% , compared with concrete without mineral admixtures.展开更多
Backscattered electron images(BSE) obtained by scanning electron microscope was used to quantitatively characterize the microstructure of interfacial transition zone(ITZ) in concrete. Influences of aggregate size...Backscattered electron images(BSE) obtained by scanning electron microscope was used to quantitatively characterize the microstructure of interfacial transition zone(ITZ) in concrete. Influences of aggregate size(5, 10, 20, and 30 mm), water to cement ratio(0.23, 0.35 and 0.53) and curing time(from 3d to 90d) on the microstructure of interfacial transition zone between coarse aggregate and bulk cement matrix were investigated. The volume percentage of detectable porosity and unhydrated cement in ITZ was quantitatively analyzed and compared with that in the matrix of various concretes. Nanoindentation technology was applied to obtain the elastic properties of ITZ and matrix, and the elastic modulus of concrete was then calculated based on the Lu & Torquato model and self-consistence scheme by using the ITZ thickness and elastic modulus obtained from this investigation. The experimental results demonstrated that the microstructure and thickness of ITZ in concrete vary with a variety of factors, like aggregate size, water to cement ratio and curing time. The relative low elastic properties of ITZ should be paid attention to, especially for early age concrete.展开更多
This study develops a novel cervical precancerous detection system by using texture analysis of field emission scanning electron microscopy(FE-SEM)images.The processing scheme adopted in the proposed system focused on...This study develops a novel cervical precancerous detection system by using texture analysis of field emission scanning electron microscopy(FE-SEM)images.The processing scheme adopted in the proposed system focused on two steps.The first step was to enhance cervical cell FE-SEM images in order to show the precancerous characterization indicator.A problem arises from the question of how to extract features which characterize cervical precancerous cells.For the first step,a preprocessing technique called intensity transformation and morphological operation(ITMO)algorithm used to enhance the quality of images was proposed.The algo-rithm consisted of contrast stretching and morphological opening operations.The second step was to characterize the cervical cells to three classes,namely normal,low grade intra-epithelial squamous lesion(LSIL),and high grade intra-epithelial squamous lesion(HSIL).To differen-tiate between normal and precancerous cells of the cervical cell FE-SEM images,human papillomavirus(HPV)contained in the surface of cells were used as indicators.In this paper,we investigated the use of texture as a tool in determining precancerous cell images based on the observation that cell images have a distinct visual texture.Gray level co-occurrences matrix(GLCM)technique was used to extract the texture features.To confirm the system's perfor-mance,the system was tested using 150 cervical cell FE-SEM images.The results showed that the accuracy,sensitivity and specificity of the proposed system are 95.7%,95.7%and 95.8%,respectively.展开更多
An effective algorithm of electronic image stabilization (EIS) of catadioptric panoramic imaging system for track robots is presented. The key techniques of this algorithm are as follows:① A model of electronic im...An effective algorithm of electronic image stabilization (EIS) of catadioptric panoramic imaging system for track robots is presented. The key techniques of this algorithm are as follows:① A model of electronic image stabilization is built by analyzing the imaging theory and the principle of EIS, and the image shift function of unwrapped panoramic image is deduced;② The relationship equation between motion estimation parameters of annular panoramic image and motion estimation parameters of unwrapped panoramic image is developed according to the constrained aspect ratio of real objects, motion parameters of annular panoramic image are firstly estimated, and then motion parameters among the image shift function are carried out according to the relationship equation;③ An excessive stabilization threshold is presented to prevent the phenomena of excessive stabilization, and the Kalman filtering is adopted to smooth the image sequences. Numerical experimental results show that this algorithm can effectively smooth out the unwanted motion and follow the intentional camera movement under certain resolutions.展开更多
The geometric structures and vibration frequencies of para-chlorofluorobenzene(p-Cl FPh)in the first excited state of neutral and ground state of cation were investigated by resonanceenhanced multiphoton ionization an...The geometric structures and vibration frequencies of para-chlorofluorobenzene(p-Cl FPh)in the first excited state of neutral and ground state of cation were investigated by resonanceenhanced multiphoton ionization and slow electron velocity-map imaging.The infrared spectrum of S0 state and absorption spectrum for S1←S0 transition in p-Cl FPh were also recorded.Based on the one-color resonant two-photon ionization spectrum and two-color resonant two-photon ionization spectrum,we obtained the adiabatic excited-state energy of p-Cl FPh as 36302±4 cm^-1.In the two-color resonant two-photon ionization slow electron velocity-map imagin spectra,the accurate adiabatic ionization potential of p-Cl FPh was extrapolated as 72937±8 cm^-1 via threshold ionization measurement.In addition,FranckCondon simulation was performed to help us confidently ascertain the main vibrational modes in the S1 and D0 states.Furthermore,the mixing of vibrational modes between S0→S1 and S1→D0 has been analyzed.展开更多
Electron affinities(EA)of most lanthanide elements still remain unknown owing to their relatively lower EA values and the fairly complicated electronic structures.In the present work,we report the high-resolution phot...Electron affinities(EA)of most lanthanide elements still remain unknown owing to their relatively lower EA values and the fairly complicated electronic structures.In the present work,we report the high-resolution photoelectron spectra of atomic cerium anion Ce−using the slow electron velocity-map imaging method in combination with a cold ion trap.The electron affinity of Ce is determined to be 4840.62(21)cm^-1 or 0.600160(26)eV.Moreover,several excited states of Ce(^4H9/2,^4I9/2,^2H9/2,^2G9/2,^2G7/2,^4H13/2,^2F5/2,and ^4I13/2)are observed.展开更多
基金supported by the National Magnetic Confinement Fusion Energy Program of China(No.2019YFE03020001)the Collaborative Innovation Program of Hefei Science Center,CAS(No.2021HSC-CIP010)the Fundamental Research Funds for the Central Universities。
文摘Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has been established that facilitates microwave imaging reflectometry and electron cyclotron emission imaging.This platform utilizes plasma profiles as input and incorporates the finite-difference time domain,ray tracing and the radiative transfer equation to calculate the propagation of plasma spontaneous radiation and the external electromagnetic field in plasmas.Benchmark tests for classical cases have been conducted to verify the accuracy of every core module in the GSD platform.Finally,2D imaging of a typical electron temperature distribution is reproduced by this platform and the results are consistent with the given real experimental data.This platform also has the potential to be extended to 3D electromagnetic field simulations and other microwave diagnostics such as cross-polarization scattering.
基金supported by the National Basic Research Program of China (No. 2008CB717800)National Natural Science Foundation of China (No. 10335060)+2 种基金Grants from the Ministry of Education and the Chinese Academy of SciencesCAS-JSPS Core University Program in Plasma and Nuclear Fusionby the PRC-US Fusion Cooperation Program (Plasma Physics, Project A-5)
文摘An upgraded electron cyclotron emission imaging (ECEI) system consisting of new optics lenses with necessary electronics for receiving and processing signals for two dimension (2D) ECEI diagnostics was installed on EAST. Hyperboloid lens were adopted in the new system to optimize the spatial resolutions. The mixers array of sixteen elements measured the plasma electron cyclotron emission at eight frequencies simultaneously, and the profiles of the electron temperature and its fluctuation in an area of 20 cm (vertical) × 6 cm (horizontal) could then be analyzed. Evolution of sawtooth precursor and crash in EAST was observed.
基金support from ACS Petroleum Research Fund(Grant No.53780-DNI7)NSF(Grant No.CMMI-1405355)
文摘Imaging systems in nature have attracted a lot of research interest due to their superior optical and imaging characteristics, Recent advancements in materials science, mechanics, and stretchable electronics have led to successful development of bioinspired cameras that resemble the structures and functions of biological light-sensing organs. In this review, we discuss some recent progresses in mechanics of bioinspired imaging systems, including tunable hemispherical eyeball camera and artificial compound eye camera. The mechanics models and results reviewed in this article can provide efficient tools for design and optimization of such systems, as well as other related optoelectronic systems that combine rigid elements with soft substrates.
基金supported by the National Natural Science Foundation of China (Grant No 10335060)PRC–US Fusion Cooperation Program (Plasma Physics,Project A–5)Chinese Academy of Sciences and Japanese Society of Promotion of Science (CAS-JSPS) Core University Program in Plasma and Nuclear Fusion
文摘The fluctuation of the electron temperature has been measured by using the electron cyclotron emission imaging in the Hefei Tokamak-7 (HT-7) plasma. The electron temperature fluctuation with a broadband spectrum shows that it propagates in the electron diamagnetic drift direction, and the mean poloidal wave-number kθ is calculated to be about 1.58cm^-1, or k^-θρs ≈ 0.34. It indicates that the fluctuation should come from the electron drift wave turbulence. The linear global scaling of the electron temperature fluctuation with the gradient of electron temperature is consistent with the mixing length scale qualitatively. Evolution of spectrum of the fluctuation during the sawtooth oscillation phases is investigated, and the fluctuation is found to increase with the gradient of electron temperature increasing during most phases of the sawtooth oscillation. The results indicate that the electron temperature gradient is probably the driver of the fluctuation enhancement. The steady heat flux driven by electron temperature fluctuation is estimated and compared with the results from power balance estimation.
文摘The principle, imaging condition and experimental method for obtaining high resolution composition contrast in secondary electron image were described. A new technique of specimen preparation for secondary electron composition contrast observation was introduced and discussed. By using multilayer P+Si1-xGex/pSi heterojunction internal photoemission infrared detector as an example, the applications of secondary electron composition contrast imaging in microstructure studies on heterojunction semiconducting materials and devices were stated. The characteristics of the image were compared with the ordinary transmission electron diffraction contrast image. The prospects of applications of the imaging method in heterojunction semiconductor devices and multilayer materials are also discussed.
基金supported by National Nature Science Foundation of China(Nos.10235010,10335000)JSPS-CAS Core University Program in the Field of Plasma and Nuclear Fusion Grants from the Ministry of Education and the Academy of Science of China
文摘At the first stage of the electron cyclotron emission imaging (ECEI) diagnostic project on HT-7, a 16-channel vertical-resolved ECEI diagnostic has been developed and installed on HT-7 tokamak to measure electron cyclotron emission with a temporal resolution of 0.5 usec. The system works at a fixed frequency of 97.5 GHz. The sample volumes of the system are aligned vertically with a vertical channel spacing of 11 mm, and can be shifted across the plasma cross-section by varying the toroidal magnetic field. The high spatial resolution of the system is achieved by utilizing a low-cost linear mixer/receiver array and an optical imaging system. The focus location may be shifted horizontally when translating one of the optical imaging elements. The details of the system design and laboratory testing of the ECEI optics are presented together with the preliminary experimental results.
基金Supported by the National Magnetic Confinement Fusion Energy Program of China under Grant Nos 2013GB106002 and 2014GB109002the National Natural Science Foundation of China under Grant Nos 10990210 and 11275200
文摘The m/n = 1/1 and its higher harmonic modes are observed in sawtooth oscillations by using the novel high- resolution 2D ECE imaging system on the experimental advanced superconducting Tokamak (EAST). Higher harmonic modes are appearing for a short time during the crash phase of sawtooth oscillation in lower βp plasma, which is not the preferabie position in the poloidal cross section. These modes generate sharp pressure points on the inversion radius during the crash phase of sawtooth oscillation. Furthermore, reconnection events proceed in two distinctive phases. In the first phase, a small amount of heat is expelled through the weak reconnection while in the second phase the remaining large quantity of heat and particles emerged rapidly from the hot core to the peripheral region of the inversion radius. In addition, these harmonic modes are only found before and after the ICRF pulse, while in the ICRF pulse only the (1,1) mode exists in the sawtooth oscillation.
基金Supported by the National Basic Research Program of China under Grant No 2013CB922404the National Natural Science Foundation of China under Grant Nos 11474040,11474039,61605017 and 61575030the Project of Changchun Science and Technology Bureau under Grant No 14KP007
文摘We report direct nanoscale imaging of ultrafast plasmon in a gold dolmen nanostructure excited with the 7is laser pulses by combining the interferometric time-resolved technology with the three-photon photoemission electron microscopy (PEEM). The interferometric time-resolved traces show that the plasmon mode beating pattern appears at the ends of the dimer slabs in the dolmen nanostructure as a result of coherent superposition of multiple localized surface plasmon modes induced by broad bandwidth of the ultrafast laser pulses. The PEEM measurement further discloses that in-phase of the oscillation field of two neighbor defects are surprisingly observed, which is attributed to the plasmon coupling between them. Furthermore, the control of the temporal delay between the pump and probe laser pluses could be utilized for manipulation of the near-field distribution. These findings deepen our understanding of ultrafast plasmon dynamics in a complex nanosystem.
文摘Using a scanning electron microscope (SEM) in the back-scattered electron (BSE) mode the composition of multi-element specimens may be determined based on the strong dependence of emission coefficient η on the average atomic number of elements Z. The output video signal of the usual BSE detectors is produced from their sensors, and the larger proportion of high-energy electrons with modified spectrum is added. Since η = is/ip (is and ip currents of specimen and probe), better accuracy must be achieved by direct measurements those currents on the specimen surface. Here, an experimental model of a current detector for a presented specimen is described. The cage is mounted on the carousel of the moving specimen stage. The input of the preamplifier is connected to the specimen holder in the form of a disk, the diameter of which is 12 mm. When the probe along its surface scanned, the input potential begins to pulsate with a negative polarity. The output of this preamplifier is connected to a small light-emitting diode, which creates intensity-modulated radiation in the chamber. Thus created the light video signal will be picked up by the photomultiplier of the E-T detector. The modes of true SE and BSE are set by applying tens bias volts of various polarities to the specimens or the cage itself.
基金the National Natural Science Foundation (60572152) of China and Science Foundation ofShaanxi Province (2005F26)
文摘A new robust electronic image stabilization system is presented, which involves feature-point, tracking based global motion estimation and Kalman filtering based motion compensation. First, global motion is estimated from the local motions of selected feature points. Considering the local moving objects or the inevitable mismatch, the matching validation, based on the stable relative distance between the points set is proposed, thus maintaining high accuracy and robustness. Next, the global motion parameters are accumulated for correction by Kalman filteration. The experimental result illustrates that the proposed system is effective to stabilize translational, rotational, and zooming jitter and robust to local motions.
基金supported by Industrial University of Ho Chi Minh City(IUH)under grant number 68/HD--DHCN.
文摘Currently,the 65Mn steel is quenched mainly by oil media.Even though the lower cooling rate of oil compared to water reduces the hardness of steel post quenching,the deforming and cracking of parts are often minimized.On the other hand,the oil media also has the disadvantage of being ammable,creating smoke that adversely affects the media.The poly alkylene glycol(PAG)polymer quenchant is commonly used for quenching a variety of steels based on its advantages such as non-ammability and exible cooling rate subjected to varying concentration and stirring speed.This article examines the effect of PAG polymer quenching solution(with concentrations of 10%and 20%)on deformation,hardness,and microstructure of C-ring samples made of 65Mn steel.Furthermore,the performance of PAG polymer quenchant is also compared with those of two common quenching solutions:Water and oil.When cooling in water,the C-ring samples had the largest deformation and 2 times higher than the results obtained when a 10%PAG solution was used.In particular,similar levels of deformation on the C-ring samples were observed in both cases of 20%PAG solution and oil as the primary quenching media.Furthermore,the hardness level measured between the sampled parts quenched in the 20%PAG solution appeared to be more uniform than that obtained from the oil-quenched sample.The study of the microscopic structure of steel by optical microscopy combined with X-ray diffraction showed that the water hardened sample exhibited cracks and comprised of two phases,martensite and retained austenite.According to the results of Electron Back Scattering Diffraction(EBSD)analysis and backscattering electronic image(BSE),the content of austenite residue in the sample when the sample was cooled in PAG 10 and 20%solution was 3.21%and 4.73%,respectively and smaller than the measurements obtained from oil quenching solution.Thus,the 65Mn steel is cooled in 20%PAG solution for high hardness and more evenly distributed than when it is quenched in oil while still ensuring a small level of deformation.Therefore,the PAG 20%solution can completely replace oil as the main media used to quench the 65Mn steel.
文摘The influences of hydrogen on the mechanical properties and the fracture behaviour of Fe-22Mn-0.6C twinning induced plasticity steel have been investigated by slow strain rate tests and fractographic analysis.The steel showed high susceptibility to hydrogen embrittlement,which led to 62.9%and 74.2%reduction in engineering strain with 3.1 and 14.4 ppm diffusive hydrogen,respectively.The fracture surfaces revealed a transition from ductile to brittle dominated fracture modes with the rising hydrogen contents.The underlying deformation and fracture mechanisms were further exploited by examining the hydrogen effects on the dislocation substructure,stacking fault probability,and twinning behaviour in pre-strained slow strain rate test specimens and notched tensile specimens using coupled electron channelling contrast imaging and electron backscatter diffraction techniques.The results reveal that the addition of hydrogen promotes planar dislocation structures,earlier nucleation of stacking faults,and deformation twinning within those grains which have tensile axis orientations close to<111>//rolling direction and<112>//rolling direction.The developed twin lamellae result in strain localization and micro-voids at grain boundaries and eventually lead to grain boundary decohesion.
基金supported by the National Natural Science Foundation of China(6110118561302145)
文摘Digital image stabilization technique plays important roles in video surveillance and object acquisition.Many useful electronic image stabilization algorithms have been studied.A real-time algorithm is proposed based on field image gray projection which enables the regional odd and even field image to be projected into x and y directions and thus to get the regional gray projection curves in x and y directions,respectively.For the odd field image channel,motion parameters can be estimated via iterative minimum absolute difference based on two successive field image regional gray projection curves.Then motion compensations can be obtained after using the Kalman filter method.Finally,the odd field image is adjusted according to the compensations.In the mean time,motion compensation is applied to the even field image channel with the odd field image gray projection curves of the current frame.By minimizing absolute difference between odd and even field image gray projection curves of the current frame,the inter-field motion parameters can be estimated.Therefore,the even field image can be adjusted by combining the inter-field motion parameters and the odd field compensations.Finally,the stabilized image sequence can be obtained by synthesizing the adjusted odd and even field images.Experimental results show that the proposed algorithm can run in real-time and have a good stabilization performance.In addition,image blurring can be improved.
基金National Natural Science Foundation of China(Grant Nos.52072072,52025121 and 51605087).
文摘Noise,vibration and harshness(NVH)problems in vehicle engineering are always challenging in both traditional vehicles and intelligent vehicles.Although high accuracy manufacturing,modern structural roads and advanced suspension technology have already significantly reduced NVH problems and their impacts;off-road condition,obstacles and extreme operating condition could still trigger NVH problems unexpectedly.This paper proposes a vehicular electronic image stabilization(EIS)system to solve the vibration problem of the camera and ensure the environment perceptive function of vehicles.Firstly,feature point detection and matching based on an oriented FAST and rotated BRIEF(ORB)algorithm are implemented to match images in the process of EIS.Furthermore,a novel improved random sampling consensus algorithm(i-RANSAC)is proposed to eliminate mismatched feature points and increase the matching accuracy significantly.And an adaptive Kalman filter(AKF)is applied to improve the adaptability of the vehicular EIS.Finally,an experimental platform based on a gasoline model car was established to validate its performance.The experimental results show that the proposed EIS system can satisfy vehicular performance requirements even under off-road condition with obvious obstacles.
文摘The coarse pore system, interfacial transition zone (ITZ) between aggregate and paste matrix and volume fraction of unhydrated cement in concrete (w/c=0.3) containing mineral admixtures were quantitatively characterized by the scanning electron microscope-backscattered electron (SEM-BSE) image analysis technique. The experimental results show that compound addition of slag and fly ash decreases the coarse porosity from 10.17% to 3.74% and the threshold diameter of coarse pore size from 345 μm to 105 μm compared with concrete (w/c=0.30) without mineral admixtures; Moreover with compound addition of fly ash and slag, the volume proportion of unhydrated cement in paste matrix is reduced by 30%, the maximum amount of coarse pores in the ITZ between aggregate and paste decreases from 13.11% to 5.57% and the thickness of ITZ is reduced by 37% , compared with concrete without mineral admixtures.
基金Funded by the National Natural Science Foundation of China(No.51178105)the Major State Basic Research Development Program of China(973 Program)(No.2015CB655104)the Collaborative Innovation Centre for Advanced Civil Engineering Materials
文摘Backscattered electron images(BSE) obtained by scanning electron microscope was used to quantitatively characterize the microstructure of interfacial transition zone(ITZ) in concrete. Influences of aggregate size(5, 10, 20, and 30 mm), water to cement ratio(0.23, 0.35 and 0.53) and curing time(from 3d to 90d) on the microstructure of interfacial transition zone between coarse aggregate and bulk cement matrix were investigated. The volume percentage of detectable porosity and unhydrated cement in ITZ was quantitatively analyzed and compared with that in the matrix of various concretes. Nanoindentation technology was applied to obtain the elastic properties of ITZ and matrix, and the elastic modulus of concrete was then calculated based on the Lu & Torquato model and self-consistence scheme by using the ITZ thickness and elastic modulus obtained from this investigation. The experimental results demonstrated that the microstructure and thickness of ITZ in concrete vary with a variety of factors, like aggregate size, water to cement ratio and curing time. The relative low elastic properties of ITZ should be paid attention to, especially for early age concrete.
基金UM Postgraduate Research Fund PG083-2013B and UM High Impact Research Grant UM-MOHE UM.C/625/1/HIR/MOHE/14 from the Ministry of Higher Education,Malaysia..
文摘This study develops a novel cervical precancerous detection system by using texture analysis of field emission scanning electron microscopy(FE-SEM)images.The processing scheme adopted in the proposed system focused on two steps.The first step was to enhance cervical cell FE-SEM images in order to show the precancerous characterization indicator.A problem arises from the question of how to extract features which characterize cervical precancerous cells.For the first step,a preprocessing technique called intensity transformation and morphological operation(ITMO)algorithm used to enhance the quality of images was proposed.The algo-rithm consisted of contrast stretching and morphological opening operations.The second step was to characterize the cervical cells to three classes,namely normal,low grade intra-epithelial squamous lesion(LSIL),and high grade intra-epithelial squamous lesion(HSIL).To differen-tiate between normal and precancerous cells of the cervical cell FE-SEM images,human papillomavirus(HPV)contained in the surface of cells were used as indicators.In this paper,we investigated the use of texture as a tool in determining precancerous cell images based on the observation that cell images have a distinct visual texture.Gray level co-occurrences matrix(GLCM)technique was used to extract the texture features.To confirm the system's perfor-mance,the system was tested using 150 cervical cell FE-SEM images.The results showed that the accuracy,sensitivity and specificity of the proposed system are 95.7%,95.7%and 95.8%,respectively.
基金Supported by State Key Laboratory of Explosion Science and Technology Foundation(ZDKT08-05)
文摘An effective algorithm of electronic image stabilization (EIS) of catadioptric panoramic imaging system for track robots is presented. The key techniques of this algorithm are as follows:① A model of electronic image stabilization is built by analyzing the imaging theory and the principle of EIS, and the image shift function of unwrapped panoramic image is deduced;② The relationship equation between motion estimation parameters of annular panoramic image and motion estimation parameters of unwrapped panoramic image is developed according to the constrained aspect ratio of real objects, motion parameters of annular panoramic image are firstly estimated, and then motion parameters among the image shift function are carried out according to the relationship equation;③ An excessive stabilization threshold is presented to prevent the phenomena of excessive stabilization, and the Kalman filtering is adopted to smooth the image sequences. Numerical experimental results show that this algorithm can effectively smooth out the unwanted motion and follow the intentional camera movement under certain resolutions.
基金the National Natural Science Foundation of China(No.11674003,No.21873003,No.21503003,No.11704004,and No.61475001)Anhui Natural Science Foundation(No.1908085QA17)+1 种基金support from Special Program for Applied Research on Super Computation of the NSFC-Guangdong Joint Fund(the second phase)(No.U1501501)Super Computation Center of Shenzhen。
文摘The geometric structures and vibration frequencies of para-chlorofluorobenzene(p-Cl FPh)in the first excited state of neutral and ground state of cation were investigated by resonanceenhanced multiphoton ionization and slow electron velocity-map imaging.The infrared spectrum of S0 state and absorption spectrum for S1←S0 transition in p-Cl FPh were also recorded.Based on the one-color resonant two-photon ionization spectrum and two-color resonant two-photon ionization spectrum,we obtained the adiabatic excited-state energy of p-Cl FPh as 36302±4 cm^-1.In the two-color resonant two-photon ionization slow electron velocity-map imagin spectra,the accurate adiabatic ionization potential of p-Cl FPh was extrapolated as 72937±8 cm^-1 via threshold ionization measurement.In addition,FranckCondon simulation was performed to help us confidently ascertain the main vibrational modes in the S1 and D0 states.Furthermore,the mixing of vibrational modes between S0→S1 and S1→D0 has been analyzed.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.91736102 and 11974199)the National Key R&D Program of China(Grant No.2018YFA0306504).
文摘Electron affinities(EA)of most lanthanide elements still remain unknown owing to their relatively lower EA values and the fairly complicated electronic structures.In the present work,we report the high-resolution photoelectron spectra of atomic cerium anion Ce−using the slow electron velocity-map imaging method in combination with a cold ion trap.The electron affinity of Ce is determined to be 4840.62(21)cm^-1 or 0.600160(26)eV.Moreover,several excited states of Ce(^4H9/2,^4I9/2,^2H9/2,^2G9/2,^2G7/2,^4H13/2,^2F5/2,and ^4I13/2)are observed.