Performance optimization of the neutron-sensitive image intensifier used in neutron imaging
1
作者 谭金昊 宋玉收 +14 位作者 周健荣 杨文钦 蒋兴奋 刘杰 张超月 周晓娟 夏远光 刘术林 闫保军 刘辉 王松林 赵豫斌 庄建 孙志嘉 陈元柏 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第8期380-387,共8页
As a non-destructive testing technology,neutron imaging plays an important role in various fields,including material science,nuclear engineering,and fundamental science.An imaging detector with a neutron-sensitive ima... As a non-destructive testing technology,neutron imaging plays an important role in various fields,including material science,nuclear engineering,and fundamental science.An imaging detector with a neutron-sensitive image intensifier has been developed and demonstrated to achieve good spatial resolution and timing resolution.However,the influence of the working voltage on the performance of the neutron-sensitive imaging intensifier has not been studied.To optimize the performance of the neutron-sensitive image intensifier at different voltages,experiments have been performed at the China Spallation Neutron Source(CSNS)neutron beamline.The change in the light yield and imaging quality with different voltages has been acquired.It is shown that the image quality benefits from the high gain of the microchannel plate(MCP)and the high accelerating electric field between the MCP and the screen.Increasing the accelerating electric field is more effective than increasing the gain of MCPs for the improvement of the imaging quality.Increasing the total gain of the MCP stack can be realized more effectively by improving the gain of the standard MCP than that of the n MCP.These results offer a development direction for image intensifiers in the future. 展开更多
关键词 neutron detector neutron imaging microchannel plate image intensifier
下载PDF
Holographic Goggles Optical System
2
作者 陈晃明 《Journal of Beijing Institute of Technology》 EI CAS 1992年第1期31-34,共4页
Based on the holographic theory, a pair of reflective holographic lenses have been utilized with an aim to improve the optical properties of night vision goggles. The aberration distribution of the holographic lens ha... Based on the holographic theory, a pair of reflective holographic lenses have been utilized with an aim to improve the optical properties of night vision goggles. The aberration distribution of the holographic lens has been confirmed by experiments and compensated by a conventional symmetrical spherical system. Resulting data of the whole optical system are given. 展开更多
关键词 image intensifiers grlatin/holographic goggles roof mirror exit pupil
下载PDF
Intensified CCD Image Sensor
3
作者 LIUJikun ZHAOBaoyun 《Semiconductor Photonics and Technology》 CAS 1997年第3期232-236,共5页
Work has been done with extending the useful imaging and detection range of CCD.This was accomplished through direct optical coupling and bonding of i-mage intensifiers to the CCD.It has been shown that the useful ran... Work has been done with extending the useful imaging and detection range of CCD.This was accomplished through direct optical coupling and bonding of i-mage intensifiers to the CCD.It has been shown that the useful range of a CCD may be extended two orders of magnitude using these techniques in coupling a microchannel plate image intensifier to the CCD array.All of these works were done with presently available CCD made by China. 展开更多
关键词 CCD Image intensifier ICCD
下载PDF
A novel 2-dimensional cosmic ray position detector based on a CsI(Na) pixel array and an ICCD camera
4
作者 葛永帅 王志刚 +14 位作者 俞伯祥 谢宇广 章爱武 薛镇 刘颖彪 高龙 牛顺利 蔡啸 方建 孙希磊 吕绮雯 宁飞鹏 周莉 胡涛 吕军光 《Chinese Physics C》 SCIE CAS CSCD 2012年第11期1101-1105,共5页
A novel 2-D cosmic ray position detector has been built and studied. It is integrated from a CsI(Na) crystal pixel array, an optical fiber array, an image intensifier and an ICCD camera. The 2-D positions of one cos... A novel 2-D cosmic ray position detector has been built and studied. It is integrated from a CsI(Na) crystal pixel array, an optical fiber array, an image intensifier and an ICCD camera. The 2-D positions of one cosmic ray track is determined by the location of a fired CsI(Na) pixel. The scintillation light of these 1.0× 1.0 mm CsI(Na) pixels is delivered to the image intensifier through fibers. The light information is recorded in the ICCD camera in the form of images, from which the 2-D positions can be reconstructed. The background noise and cosmic ray images have been studied. The study shows that the cosmic ray detection efficiency can reach up to 11.4%, while the false accept rate is less than 1%. 展开更多
关键词 cosmic ray 2-D position CsI(Na) crystal pixel array optical fiber array image intensifier ICCD camera