期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
The Development of A Fluorescence Polarization Immunoassay for Aflatoxin Detection 被引量:11
1
作者 SHENG Ya Jie EREMIN Sergei +3 位作者 MI Tie Jun ZHANG Su Xia SHEN Jian Zhong WANG Zhan Hui 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第2期126-129,共4页
A fluorescence polarization immunoassay (FPIA) was developed for the analysis ofaflatoxins (AFs) using an anti-aflatoxin B1 (AFB1) monoclonal antibody and a novel fluorescein-labeled AFB1 tracer. The FPIA showed... A fluorescence polarization immunoassay (FPIA) was developed for the analysis ofaflatoxins (AFs) using an anti-aflatoxin B1 (AFB1) monoclonal antibody and a novel fluorescein-labeled AFB1 tracer. The FPIA showed an IC50 value of 23.33 ng/mL with a limit of detection of 13.12 ng/mL for AFB1. The cross-reactivities of AFB1, AFB2, AFG1, AFG2, AFM1, and AFM2 with the antibody were 100%, 65.7%, 143%, 23.5%, 111.4%, and 2%, respectively. The group-specificity of anti-AFB1mAb indicated that the FPIA could potentially be used in a screening method for the detection of total AFs, albeit not AFG2 and AFM2. The total time required for analyzing 96 samples in one microplate was less than 5 rain. This study demonstrates the potential usefulness of the FPIA as a rapid and simple technique for monitoring AFs. 展开更多
关键词 FPIA AFB The Development of A Fluorescence Polarization immunoassay for Aflatoxin detection AFM EDF
下载PDF
Lateral Flow Immunoassay for Quantitative Detection of Ractopamine in Swine Urine 被引量:3
2
作者 REN Mei Ling CHEN Xue Lan +4 位作者 LI Chao Hui XU Bo LIU Wen Juan XU Heng Yi XIONG Yong Hua 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第2期134-137,共4页
A strip reader based lateral flow immunoassay (LFIA) was established for the rapid and quantitative detection of ractopamine (RAC) in swine urine. The ratio of the optical densities (ODs) of the test line (AT)... A strip reader based lateral flow immunoassay (LFIA) was established for the rapid and quantitative detection of ractopamine (RAC) in swine urine. The ratio of the optical densities (ODs) of the test line (AT) to that of the control line (Ac) was used to effectively minimize interference among strips and sample variations. The linear range for the quantitative detection of RAC was 0.2 ng/mL to 3.5 ng/mL with a median inhibitory concentration (IC50) of 0.59+0.06 ng/mL. The limit of detection (LOD) of the LFIA was 0.13 ng/mL. The intra-assay recovery rates were 92.97%, 97.25%, and 107.41%, whereas the inter-assay rates were 80.07%, 108.17%, and 93.7%, respectively. 展开更多
关键词 RAC Lateral Flow immunoassay for Quantitative detection of Ractopamine in Swine Urine FIGURE AT
下载PDF
Electrochemical detection of human ferritin based on gold nanorod reporter probe and cotton thread immunoassay device 被引量:1
3
作者 Ting-Ting Song Wei Wang +3 位作者 Li-Li Meng Yan Liu Xiao-Bo Jia Xun Mao 《Chinese Chemical Letters》 SCIE CAS CSCD 2017年第2期226-230,共5页
In this study,a natural cotton thread immunoassay device combined with gold nanorod(GNR) reporter probe is developed for the rapid,sensitive and quantitative electrochemical determination of human ferritin,a lung ca... In this study,a natural cotton thread immunoassay device combined with gold nanorod(GNR) reporter probe is developed for the rapid,sensitive and quantitative electrochemical determination of human ferritin,a lung cancer related biomarker.Human ferritin as an analyte and a pair of monoclonal antibodies are used to demonstrate the proof-of-concept on the cotton thread immunoassay device.An enhancement of the sensitivity is achieved by using gold nanorod as an electroactive report probe compared with a traditional gold nanoparticle(GNP) report probe.The device was capable of measuring 1.58 ng/mL ferritin in 30 min by anodic stripping voltammetry(ASV) testing,which meet the requirement for clinical diagnosis. 展开更多
关键词 Cotton thread immunoassay device Gold nanorod reporter probe Point-of-care diagnosis Protein detection Electrochemical immunoassay
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部