期刊文献+
共找到31,370篇文章
< 1 2 250 >
每页显示 20 50 100
Is primary transcatheter aortic valve implantation the new normal?
1
作者 R.Anantharaman C.Sundar +1 位作者 Kamal Kant Jena K.Arun 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2024年第4期458-461,共4页
Degenerative calcific aortic valve stenosis(AS)is the most common valvular heart disease in elderly.^[1] It is well documented that symptomatic severe AS follows a malignant course leading to cardiogenic shock(CS).
关键词 AORTIC STENOSIS implantATION
下载PDF
Nursing Care and Causative Analysis of Grade IV Capsular Contracture Following Breast Cancer Expander Implantation
2
作者 Rong Chen Nan Zhang Huiting Zhang 《Advances in Breast Cancer Research》 CAS 2024年第1期1-9,共9页
Objective: By observing the treatment and nursing care of a patient with Grade IV capsular contracture following breast cancer expander implantation and subsequent Stage II reconstruction, we aim to analyze the reason... Objective: By observing the treatment and nursing care of a patient with Grade IV capsular contracture following breast cancer expander implantation and subsequent Stage II reconstruction, we aim to analyze the reasons for the formation of capsular contracture after Stage I expander implantation and prevent its recurrence following Stage II reconstruction. Methods: In May 2020, the patient noticed an increase in the size of a breast mass. In August, she underwent AC-THP neoadjuvant chemotherapy, followed by a “right breast-conserving nipple-areolar subglandular excision + right axillary lymph node dissection + expander implantation” surgery in November 2020. Radiation therapy began in January 2021. During radiation therapy, the patient experienced severe breast hardening, distortion, tenderness, and was diagnosed with Grade IV capsular contracture. To relieve the capsular contracture, the patient underwent a “contracted capsule incision and release procedure + removal of the right breast expander + right breast implantation” surgery in July 2021. Postoperatively, measures were taken to prevent incision infection, emphasizing aseptic techniques, ensuring smooth negative pressure drainage, reducing skin flap tension, monitoring skin flap blood supply, actively preventing subcutaneous effusion and hematoma, and applying appropriate compression dressings. Results: The patient was discharged after the removal of the drainage tube. During the postoperative follow-up at 3 and 6 months, there was no recurrence of capsular contracture, and the breast appeared full, upright, and relatively soft. There were no complications such as hematoma, infection, breast implant rupture, breast sagging, or displacement. The patient had a good outcome without additional financial or surgical burdens. Conclusion: The occurrence of Grade IV capsular contracture in the patient is generally related to infection after Stage I expander implantation, improper compression dressing, excessive saline injection causing content infiltration, and radiation therapy. Therefore, it is recommended to enhance the intraoperative and postoperative prophylactic use of antibiotics after Stage I expander implantation. Intermittent saline injection after surgery, with the amount of saline gradually increasing rather than filling all at once, is advisable. This helps the breast tissue gradually adapt to expansion, reducing the risk of capsular contracture. Postoperatively, patients should be instructed to wear pressure garments and breast elastic bandages while intensifying breast monitoring during radiation therapy and increasing postoperative follow-up. 展开更多
关键词 Breast Cancer Capsular Contracture Expander implantation
下载PDF
Burden of routine orthopedic implant removal a single center retrospective study
3
作者 Ammar K AlOmran Nader Alosaimi +6 位作者 Ahmed A Alshaikhi Omar M Bakhurji Khalid J Alzahrani Basil Ziyad Salloot Tamim Omar Alabduladhem Ahmed I AlMulhim Arwa Alumran 《World Journal of Orthopedics》 2024年第2期139-146,共8页
BACKGROUND Open reduction and internal fixation represent prevalent orthopedic procedures,sparking ongoing discourse over whether to retain or remove asymptomatic implants.Achieving consensus on this matter is paramou... BACKGROUND Open reduction and internal fixation represent prevalent orthopedic procedures,sparking ongoing discourse over whether to retain or remove asymptomatic implants.Achieving consensus on this matter is paramount for orthopedic surgeons.This study aims to quantify the impact of routine implant removal on patients and healthcare facilities.A retrospective analysis of implant removal cases from 2016 to 2022 at King Fahad Hospital of the University(KFHU)was conducted and subjected to statistical scrutiny.Among these cases,44%necessitated hospitalization exceeding one day,while 56%required only a single day.Adults exhibited a 55%need for extended hospital stays,contrasting with 22.8%among the pediatric cohort.The complication rate was 6%,with all patients experiencing at least one complication.Notably,34.1%required sick leave and 4.8%exceeded 14 d.General anesthesia was predominant(88%).Routine implant removal introduces unwarranted complications,particularly in adults,potentially prolonging hospitalization.This procedure strains hospital resources,tying up the operating room that could otherwise accommodate critical surgeries.Clearly defined institutional guidelines are imperative to regulate this practice.AIM To measure the burden of routine implant removal on the patients and hospital.METHODS This is a retrospective analysis study of 167 routine implant removal cases treated at KFHU,a tertiary hospital in Saudi Arabia.Data were collected in the orthopedic department at KFHU from February 2016 to August 2022,which includes routine asymptomatic implant removal cases across all age categories.Nonroutine indications such as infection,pain,implant failure,malunion,nonunion,restricted range of motion,and prominent hardware were excluded.Patients who had external fixators removed or joints replaced were also excluded.RESULTS Between February 2016 and August 2022,360 implants were retrieved;however,only 167 of those who met the inclusion criteria were included in this study.The remaining implants were rejected due to exclusion criteria.Among the cases,44%required more than one day in the hospital,whereas 56%required only one day.55%of adults required more than one day of hospitalization,while 22.8%of pediatric patients required more than one day of inpatient care.The complication rate was 6%,with each patient experiencing at least one complication.Sick leave was required in 34.1%of cases,with 4.8%requiring more than 14 d.The most common type of anesthesia used in the surgeries was general anesthesia(88%),and the mean(SD)surgery duration was 77.1(54.7)min.CONCLUSION Routine implant removal causes unnecessary complications,prolongs hospital stays,depletes resources and monopolizing operating rooms that could serve more critical procedures. 展开更多
关键词 implant removal Healed fracture Orthopedic implant COMPLICATIONS Healthcare system
下载PDF
In‑depth proteome characterization of endometrium and extraembryonic membranes during implantation in pig
4
作者 Maria A.Gil Josep M.Cambra +3 位作者 Heriberto Rodriguez‑Martinez Cristina Cuello Inmaculada Parrilla Emilio A.Martinez 《Journal of Animal Science and Biotechnology》 SCIE CAS CSCD 2024年第3期1027-1055,共29页
Background Proteome characterization of the porcine endometrium and extraembryonic membranes is important to understand mother-embryo cross-communication.In this study,the proteome of the endometrium and cho-rioallant... Background Proteome characterization of the porcine endometrium and extraembryonic membranes is important to understand mother-embryo cross-communication.In this study,the proteome of the endometrium and cho-rioallantoic membrane was characterized in pregnant sows(PS)during early gestation(d 18 and 24 of gestation)and in the endometrium of non-pregnant sows(NPS)during the same days using LC-MS/MS analysis.The UniProtKB database and ClueGO were used to obtain functional Gene Ontology annotations and biological and functional networks,respectively.Results Our analysis yielded 3,254 and 3,457 proteins identified in the endometrium of PS and NPS,respectively;of these,1,753 being common while 1,501 and 1,704 were exclusive to PS and NPS,respectively.In addition,we iden-tified 3,968 proteins in the extraembryonic membranes of PS.Further analyses of function revealed some proteins had relevance for the immune system process and biological adhesion in endometrium while the embryonic chorion displayed abundance of proteins related to cell adhesion and cytoskeletal organization,suggesting they dominated the moment of endometrial remodeling,implantation and adhesion of the lining epithelia.Data are available via Pro-teomeXchange with identifier PXD042565.Conclusion This is the first in-depth proteomic characterization of the endometrium and extraembryonic mem-branes during weeks 3 to 4 of gestation;data that contribute to the molecular understanding of the dynamic environ-ment during this critical period,associated with the majority of pregnancy losses. 展开更多
关键词 ENDOMETRIUM Extraembryonic membranes implantATION PIG PROTEOME
下载PDF
Graphene-calcium carbonate coating to improve the degradation resistance and mechanical integrity of a biodegradable implant
5
作者 Lokesh Choudhary Parama Chakraborty Banerjee +5 位作者 R.K.Singh Raman Derrek E.Lobo Christopher D.Easton Mainak Majumder Frank Witte Jörg F.Löffler 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第1期394-404,共11页
Biodegradable implants are critical for regenerative orthopaedic procedures,but they may suffer from too fast corrosion in human-body environment.This necessitates the synthesis of a suitable coating that may improve ... Biodegradable implants are critical for regenerative orthopaedic procedures,but they may suffer from too fast corrosion in human-body environment.This necessitates the synthesis of a suitable coating that may improve the corrosion resistance of these implants without compromising their mechanical integrity.In this study,an AZ91 magnesium alloy,as a representative for a biodegradable Mg implant material,was modified with a thin reduced graphene oxide(RGO)-calcium carbonate(CaCO_(3))composite coating.Detailed analytical and in-vitro electrochemical characterization reveals that this coating significantly improves the corrosion resistance and mechanical integrity,and thus has the potential to greatly extend the related application field. 展开更多
关键词 Graphene coating Biodegradable implant HYDROXYAPATITE Corrosion Magnesium alloy
下载PDF
HVOF-sprayed HAp/S53P4 BG composite coatings on an AZ31 alloy for potential applications in temporary implants
6
作者 Carlos A.Poblano-Salas John Henao +6 位作者 Astrid L.Giraldo-Betancur Paola Forero-Sossa Diego German Espinosa-Arbelaez Jorge A.González-Sánchez Luis R.Dzib-Pérez Susana T.Estrada-Moo Idelfonso E.Pech-Pech 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第1期345-360,共16页
Bioactive thermal spray coatings produced via high-velocity oxygen fuel spray(HVOF)from hydroxyapatite(HAp)and bioactive glasses(BG)have the potential to be employed on temporary implants due to the ability of both HA... Bioactive thermal spray coatings produced via high-velocity oxygen fuel spray(HVOF)from hydroxyapatite(HAp)and bioactive glasses(BG)have the potential to be employed on temporary implants due to the ability of both HAp and BG to dissolve and promote osseointegration,considering that both phases have different reaction and dissolution rates under in-vitro conditions.In the present work,75%wt.HAp-25%wt.S53P4 bioactive glass powders were HVOF-sprayed to obtain HAp/S53P4 BG composite coatings on a bioresorbable AZ31 alloy.The study is focused on exploring the effect of the stand-off distance and fuel/oxygen ratio variation as HVOF parameters to obtain stable structural coatings and to establish their effect on the phases and microstructure produced in those coatings.Different characterization techniques,such as scanning electron microscopy,X-ray diffraction,and Fourier transform infrared spectroscopy,were employed to characterize relevant structural and microstructural properties of the composite coatings.The results showed that thermal gradients during coating deposition must be managed to avoid delamination due to the high temperature achieved(max 550℃)and the differences in coefficients of thermal expansion.It was also found that both spraying distance and oxygen/fuel ratio allowed to keep the hydroxyapatite as the main phase in the coatings.In addition,in-vitro electrochemical studies were performed on the obtained HAp/S53P4 BG composite coatings and compared against the uncoated AZ31 alloy.The results showed a significant decrease in hydrogen evolution(at least 98%)when the bioactive coating was applied on the Mg alloy during evaluation in simulated body fluid(SBF). 展开更多
关键词 Coatings Composites Thermal spray Temporary implants Hydrogen evolution
下载PDF
Peri-implant gas accumulation in response to magnesium-based musculoskeletal biomaterials:Reframing current evidence for preclinical research and clinical evaluation
7
作者 Yu Sun Heike Helmholz Regine Willumeit-Römer 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第1期59-71,共13页
Historically,the rapid degradation and massive gas release from magnesium(Mg)implants resulted in severe emphysema and mechanical failure.With the advent of new alloys and surface treatment methods,optimized Mg implan... Historically,the rapid degradation and massive gas release from magnesium(Mg)implants resulted in severe emphysema and mechanical failure.With the advent of new alloys and surface treatment methods,optimized Mg implants have re-entered clinics since last decade with reliable performance.However,the optimization aims at slowing down the degradation process,rather than exemption of the gas release.This study involved a systematic evaluation of current preclinical and clinical evidence,regarding the physical signs,symptoms,radiological features,pathological findings and complications potentially associated with peri±implant gas accumulation(PIGA)after musculoskeletal Mg implantation.The literature search identified 196 potentially relevant publications,and 51 papers were enrolled for further analysis,including 22 preclinical tests and 29 clinical studies published from 2005 to 2023.Various Mg-based materials have been evaluated in animal research,and the application of pure Mg and Mg alloys have been reported in clinical follow-ups involving multiple anatomical sites and musculoskeletal disorders.Soft tissue and intraosseous PIGA are common in both animal tests and clinical follow-ups,and potentially associated with certain adverse events.Radiological examinations especially micro-CT and clinical CT scans provide valuable information for quantitative and longitudinal analysis.While according to simulation tests involving Mg implantation and chemical processing,tissue fixation could lead to an increase in the volume of gas cavity,thus the results obtained from ex vivo imaging or histopathological evaluations should be interpreted with caution.There still lacks standardized procedures or consensus for both preclinical and clinical evaluation of PIGA.However,by providing focused insights into the topic,this evidence-based study will facilitate future animal tests and clinical evaluations,and support developing biocompatible Mg implants for the treatment of musculoskeletal disorders. 展开更多
关键词 Magnesium implant Degradation Hydrogen Gas release Postoperative follow-up
下载PDF
Systemic modulation of skeletal mineralization by magnesium implant promoting fracture healing: Radiological exploration enhanced with PCA-based machine learning in a rat femoral model
8
作者 Yu Sun Heike Helmholz Regine Willumeit-Römer 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第3期1009-1020,共12页
The clinical application of magnesium(Mg)and its alloys for bone fractures has been well supported by in vitro and in vivo trials.However,there were studies indicating negative effects of high dose Mg intake and susta... The clinical application of magnesium(Mg)and its alloys for bone fractures has been well supported by in vitro and in vivo trials.However,there were studies indicating negative effects of high dose Mg intake and sustained local release of Mg ions on bone metabolism or repair,which should not be ignored when developing Mg-based implants.Thus,it remains necessary to assess the biological effects of Mg implants in animal models relevant to clinical treatment modalities.The primary purpose of this study was to validate the beneficial effects of intramedullary Mg implants on the healing outcome of femoral fractures in a modified rat model.In addition,the mineralization parameters at multiple anatomical sites were evaluated,to investigate their association with healing outcome and potential clinical applications.Compared to the control group without Mg implantation,postoperative imaging at week 12 demonstrated better healing outcomes in the Mg group,with more stable unions in 3D analysis and high-mineralized bridging in 2D evaluation.The bone tissue mineral density(TMD)was higher in the Mg group at the non-operated femur and lumbar vertebra,while no differences between groups were identified regarding the bone tissue volume(TV),TMD and bone mineral content(BMC)in humerus.In the surgical femur,the Mg group presented higher TMD,but lower TV and BMC in the distal metaphyseal region,as well as reduced BMC at the osteotomy site.Principal component analysis(PCA)-based machine learning revealed that by selecting clinically relevant parameters,radiological markers could be constructed for differentiation of healing outcomes,with better performance than 2D scoring.The study provides insights and preclinical evidence for the rational investigation of bioactive materials,the identification of potential adverse effects,and the promotion of diagnostic capabilities for fracture healing. 展开更多
关键词 MAGNESIUM implants Bone fracture MINERALIZATION Systemic modulation Principal component analysis.
下载PDF
Clinical prediction of insufficient vaults after implantable collamer lens implantation
9
作者 Jun Zhu Dan Cheng +3 位作者 Xue-Ying Zhu Fen-Fen Li Ye Yang Yu-Feng Ye 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第7期1300-1306,共7页
AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants ... AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants underwent ICL surgery and were divided into the low(<250μm)and normal(250-1000μm)vault groups based on the postoperative vault at 3mo.The preoperative biometric parameters and clinical outcomes were compared between the two groups.The relationship between the 3-month vault values and preoperative ocular parameters were evaluated by Generalized estimating equations.RESULTS:Sixteen(23 eyes)and 36 patients(63 eyes)were in the low and normal vault groups,respectively.All implantation procedures were uneventful with no cataract formation in the early postoperative period.The sulcusto-sulcus lens rise(STSL)and iris ciliary angle(ICA)were correlated with vault at 3mo after surgery.Every 0.1 mm increase in STSL was associated with 38.9μm decrease in the postoperative 3-month vault.A rise of 1 degree in ICA is associated with a reduction of 4μm in vault.CONCLUSION:Eyes with a narrow ciliary sulcus are associated with a higher rate of low vault after ICL implantation,suggesting a need for adjustments to the ICL size in these patients.Evaluating the characteristics of the ciliary sulcus contributes valuable information to predict low vault after surgery. 展开更多
关键词 insufficient vault implantable collamer lens ciliary body posterior chamber
下载PDF
Complicated calcified alloplastic implants in the nasal dorsum:A clinical analysis
10
作者 Yong-Seon Hwang Taek-Kyun Kim +2 位作者 Dong-Jun Yang Si-Hyong Jang Da-Woon Lee 《World Journal of Clinical Cases》 SCIE 2024年第18期3351-3359,共9页
BACKGROUND In rhinoplasty,calcification around silicone implants is frequently observed in the tip dorsum(TD)area.Additionally,based on a review of various literature,it is presumed that calcification in silicone impl... BACKGROUND In rhinoplasty,calcification around silicone implants is frequently observed in the tip dorsum(TD)area.Additionally,based on a review of various literature,it is presumed that calcification in silicone implants occurs due to both inflammatory chemical reactions and physical friction against the tissue.The calcification of nasal silicone implants not only results in the functional loss of the implants,but also leads to material deformation.However,there is a lack of research on calcification of nasal silicone implants in the current literature.AIM To elucidate various clinical characteristics of calcification around nasal silicone implants,using histological and radiological analysis.METHODS This study analyzed data from 16 patients of calcified nasal implants,who underwent revision rhinoplasty for various reasons after undergoing augmentation rhinoplasty with silicone implants.The collected data included information on implant duration,implant types,location of calcification,presence of inflammatory reactions,and computed tomography(CT)scans.RESULTS The most common location of calcification,as visually analyzed,was in the TD area,accounting for 56%.Additionally,the analysis of CT scans revealed a trend of increasing Hounsfield Unit values for calcification with the duration of implantation,although this trend was not statistically significant(P=0.139).CONCLUSION Our study shows that reducing the frequency of calcification may be achievable by using softer silicone implants and by minimizing the damage to perioperative tissues. 展开更多
关键词 Silicone implants RHINOPLASTY CALCIFICATION COMPLICATION Hounsfield unit
下载PDF
Advances in Wireless,Batteryless,Implantable Electronics for Real‑Time,Continuous Physiological Monitoring
11
作者 Hyeonseok Kim Bruno Rigo +2 位作者 Gabriella Wong Yoon Jae Lee Woon‑Hong Yeo 《Nano-Micro Letters》 SCIE EI CSCD 2024年第3期254-302,共49页
This review summarizes recent progress in developing wireless,batteryless,fully implantable biomedical devices for real-time continuous physiological signal monitoring,focusing on advancing human health care.Design co... This review summarizes recent progress in developing wireless,batteryless,fully implantable biomedical devices for real-time continuous physiological signal monitoring,focusing on advancing human health care.Design considerations,such as biological constraints,energy sourcing,and wireless communication,are discussed in achieving the desired performance of the devices and enhanced interface with human tissues.In addition,we review the recent achievements in materials used for developing implantable systems,emphasizing their importance in achieving multi-functionalities,biocompatibility,and hemocompatibility.The wireless,batteryless devices offer minimally invasive device insertion to the body,enabling portable health monitoring and advanced disease diagnosis.Lastly,we summarize the most recent practical applications of advanced implantable devices for human health care,highlighting their potential for immediate commercialization and clinical uses. 展开更多
关键词 implantable electronics Biomedical systems Batteryless devices Wireless electronics Physiological signal monitoring
下载PDF
Implantable Electrochemical Microsensors for In Vivo Monitoring of Animal Physiological Information
12
作者 Jin Zhou Shenghan Zhou +4 位作者 Peidi Fan Xunjia Li Yibin Ying Jianfeng Ping Yuxiang Pan 《Nano-Micro Letters》 SCIE EI CSCD 2024年第3期183-211,共29页
In vivo monitoring of animal physiological information plays a crucial role in promptly alerting humans to potential diseases in animals and aiding in the exploration of mechanisms underlying human diseases.Currently,... In vivo monitoring of animal physiological information plays a crucial role in promptly alerting humans to potential diseases in animals and aiding in the exploration of mechanisms underlying human diseases.Currently,implantable electrochemical microsensors have emerged as a prominent area of research.These microsensors not only fulfill the technical requirements for monitoring animal physiological information but also offer an ideal platform for integration.They have been extensively studied for their ability to monitor animal physiological information in a minimally invasive manner,characterized by their bloodless,painless features,and exceptional performance.The development of implantable electrochemical microsensors for in vivo monitoring of animal physiological information has witnessed significant scientific and technological advancements through dedicated efforts.This review commenced with a comprehensive discussion of the construction of microsensors,including the materials utilized and the methods employed for fabrication.Following this,we proceeded to explore the various implantation technologies employed for electrochemical microsensors.In addition,a comprehensive overview was provided of the various applications of implantable electrochemical microsensors,specifically in the monitoring of diseases and the investigation of disease mechanisms.Lastly,a concise conclusion was conducted on the recent advancements and significant obstacles pertaining to the practical implementation of implantable electrochemical microsensors. 展开更多
关键词 Electrochemical microsensors implantable sensors In vivo monitoring Animal physiological information
下载PDF
Baerveldt glaucoma implant with Supramid© ripcord stent in neovascular glaucoma: a case series
13
作者 Yuen Keat Gan Shiivaa Manjare Birapadian +1 位作者 Muhammad Irfan Abdul Jalal Norshamsiah Md Din 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期265-271,共7页
AIM:To report the outcome of Baerveldt glaucoma implant(BGI)with Supramid©ripcord use in neovascular glaucoma(NVG).METHODS:We retrospectively evaluated the surgical outcome of the BGI with Supramid©3/0 ripco... AIM:To report the outcome of Baerveldt glaucoma implant(BGI)with Supramid©ripcord use in neovascular glaucoma(NVG).METHODS:We retrospectively evaluated the surgical outcome of the BGI with Supramid©3/0 ripcord stent in patients with NVG.No tube ligation or venting slits were performed.Supramid was removed after 3mo if the target intraocular pressure(IOP)was not achieved.Surgical success was defined as IOP≤21 mm Hg with(qualified success)or without IOP-lowering medications(complete success).RESULTS:Twenty-six eyes from 24 patients were included in the study.The median duration of follow-up was 4[interquartile range(IQR)=1-5]y,ranging from 0.5 to 5y.IOP decreased by a mean of 24.2 mm Hg(59.7%);from a mean of 40.5±12.6 mm Hg at baseline to 16.3±11.9 mm Hg,P≤0.001.The number of glaucoma medications reduced from a median of 5(IQR=5-6)to 1(IQR=0-2,P≤0.001)at the final follow-up.Overall success rates were 88.0%at 1y,34.8%at 3y,66.7%at 4y,and 50%at 5y.Hypertensive phase(HP)in the first 3mo occurred in 15/26 eyes(57.7%)with a mean IOP of 31.1 mm Hg.CONCLUSION:BGI with Supramid©ripcord stent gives close to 90%of the overall survival rate at the final follow-up without significant early hypotony.However,early HP is still a challenge. 展开更多
关键词 neovascular glaucoma Supramid ripcord stent Baerveldt glaucoma implant
下载PDF
Rhegmatogenous retinal detachment in highly myopic eyes with implantable collamer lens
14
作者 Jun Li Chong-Lin Chen +2 位作者 Jia-Qing Li Xiao-Ling Liang Chun Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期392-396,共5页
AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who receiv... AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who received treatment for nontraumatic RRD after ICL implantation surgery at the Retinal Department of Zhongshan Ophthalmic Center from Jan 2018 to Dec 2022 were reviewed.Comprehensive ophthalmologic examinations including visual acuity measurement and digital fundus photography were performed in each patient.RESULTS:A total of nine RRD eyes from nine patients who received V4c-ICL implantation were included.The mean time from ICL implantation surgery to the diagnosis of RRD was 32.44±22.56mo(range,1-60mo).At the initial visit for RRD,giant retinal tear(GRT),horseshoe tear,simple round hole,and horseshoe tear combined with round hole were detected in 3,3,2,and 1 eye(s),respectively,with maculaoff in eyes.Eight patients received surgical treatment,and one patient was treated by retinal laser photocoagulation alone.The ICL was preserved in 7 eyes.At the last followup,the mean best corrected visual acuity(BCVA)improved significantly from 1.76±1.06 logMAR at presentation to 0.81±1.01 logMAR(P=0.035),and no case of recurrent retinal detachment was found.CONCLUSION:The morphological presentation of retinal breaks is diverse in this study.The ICL can be preserved in most cases during the course of retinal detachment repair surgery in our data,companied with acceptable visual and anatomical outcomes. 展开更多
关键词 high myopia implantable collamer lens rhegmatogenous retinal detachment
下载PDF
Deep brain implantable microelectrode arrays for detection and functional localization of the subthalamic nucleus in rats with Parkinson’s disease
15
作者 Luyi Jing Zhaojie Xu +11 位作者 Penghui Fan Botao Lu Fan Mo Ruilin Hu Wei Xu Jin Shan Qianli Jia Yuxin Zhu Yiming Duan Mixia Wang Yirong Wu Xinxia Cai 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2024年第4期439-452,共14页
The subthalamic nucleus(STN)is considered the best target for deep brain stimulation treatments of Parkinson’s disease(PD).It is difficult to localize the STN due to its small size and deep location.Multichannel micr... The subthalamic nucleus(STN)is considered the best target for deep brain stimulation treatments of Parkinson’s disease(PD).It is difficult to localize the STN due to its small size and deep location.Multichannel microelectrode arrays(MEAs)can rapidly and precisely locate the STN,which is important for precise stimulation.In this paper,16-channel MEAs modified with multiwalled carbon nanotube/poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate)(MWCNT/PEDOT:PSS)nanocomposites were designed and fabricated,and the accurate and rapid identification of the STN in PD rats was performed using detection sites distributed at different brain depths.These results showed that nuclei in 6-hydroxydopamine hydrobromide(6-OHDA)-lesioned brains discharged more intensely than those in unlesioned brains.In addition,the MEA simultaneously acquired neural signals from both the STN and the upper or lower boundary nuclei of the STN.Moreover,higher values of spike firing rate,spike amplitude,local field potential(LFP)power,and beta oscillations were detected in the STN of the 6-OHDA-lesioned brain,and may therefore be biomarkers of STN localization.Compared with the STNs of unlesioned brains,the power spectral density of spikes and LFPs synchronously decreased in the delta band and increased in the beta band of 6-OHDA-lesioned brains.This may be a cause of sleep and motor disorders associated with PD.Overall,this work describes a new cellular-level localization and detection method and provides a tool for future studies of deep brain nuclei. 展开更多
关键词 Functional localization implantable microelectrode arrays Parkinson’s disease Subthalamic nucleus
下载PDF
Osteotomy Protocol for Implant Insertion of One Day Biotech: One Drill, One Implant
16
作者 Jin Hwan Kim Jaehyun Song +3 位作者 Jaegyun Choi Jose Francisco Ballester Ireh Kim Santiago Jose Ballester 《Open Journal of Stomatology》 2024年第5期255-277,共23页
Background: Four factors determine the quality of an implantology kit: 1) Heat generated by the drills;2) Morphology of the osteotomy according to the diameter of the implant;3) Efficiency of collecting autologous bon... Background: Four factors determine the quality of an implantology kit: 1) Heat generated by the drills;2) Morphology of the osteotomy according to the diameter of the implant;3) Efficiency of collecting autologous bone;and 4) Osteotomy execution time. Materials and Methods: This article examines the heat produced by drills during osteotomy, focusing on the effect of the following factors: drilling technique;volume of autologous bone harvested;drilling time;implant primary stability;and the percentage of osseointegrated implants after primary healing. Discussion: The four factors mentioned above are analyzed based on the data obtained for sequential, biological, and One Drill milling techniques. Conclusions: 1) One Drill is the fastest technique for performing the osteotomy;2) All techniques stay within the biological temperature range of living bone, with the lowest increase in temperature achieved using One Drill with irrigation;3) The bone harvested showed no statistically significant differences between biological milling and the One Drill technique, both far superior to the sequential technique;and 4) There is no statistically significant difference in the number of osseointegrated implants among the three techniques analyzed. 展开更多
关键词 Dental implant Bur Primary Stability Drilling Time OSTEOTOMY Irrigation Bone Collected
下载PDF
Elimination of methicillin‑resistant Staphylococcus aureus biofilms on titanium implants via photothermally‑triggered nitric oxide and immunotherapy for enhanced osseointegration
17
作者 Yong‑Lin Yu Jun‑Jie Wu +5 位作者 Chuan‑Chuan Lin Xian Qin Franklin R.Tay Li Miao Bai‑Long Tao Yang Jiao 《Military Medical Research》 SCIE CAS CSCD 2024年第2期157-179,共23页
Background:Treatment of methicillin-resistant Staphylococcus aureus(MRSA)biofilm infections in implant placement surgery is limited by the lack of antimicrobial activity of titanium(Ti)implants.There is a need to expl... Background:Treatment of methicillin-resistant Staphylococcus aureus(MRSA)biofilm infections in implant placement surgery is limited by the lack of antimicrobial activity of titanium(Ti)implants.There is a need to explore more effective approaches for the treatment of MRSA biofilm infections.Methods:Herein,an interfacial functionalization strategy is proposed by the integration of mesoporous polydopamine nanoparticles(PDA),nitric oxide(NO)release donor sodium nitroprusside(SNP)and osteogenic growth peptide(OGP)onto Ti implants,denoted as Ti-PDA@SNP-OGP.The physical and chemical properties of Ti-PDA@SNP-OGP were assessed by scanning electron microscopy,X-ray photoelectron spectroscope,water contact angle,photothermal property and NO release behavior.The synergistic antibacterial effect and elimination of the MRSA biofilms were evaluated by 2′,7′-dichlorofluorescein diacetate probe,1-N-phenylnaphthylamine assay,adenosine triphosphate intensity,O-nitrophenyl-β-D-galactopyranoside hydrolysis activity,bicinchoninic acid leakage.Fluorescence staining,assays for alkaline phosphatase activity,collagen secretion and extracellular matrix mineralization,quantitative real‑time reverse transcription‑polymerase chain reaction,and enzyme-linked immunosorbent assay(ELISA)were used to evaluate the inflammatory response and osteogenic ability in bone marrow stromal cells(MSCs),RAW264.7 cells and their co-culture system.Giemsa staining,ELISA,micro-CT,hematoxylin and eosin,Masson's trichrome and immunohistochemistry staining were used to evaluate the eradication of MRSA biofilms,inhibition of inflammatory response,and promotion of osseointegration of Ti-PDA@SNP-OGP in vivo.Results:Ti-PDA@SNP-OGP displayed a synergistic photothermal and NO-dependent antibacterial effect against MRSA following near-infrared light(NIR)irradiation,and effectively eliminated the formed MRSA biofilms by inducing reactive oxygen species(ROS)-mediated oxidative stress,destroying bacterial membrane integrity and causing leakage of intracellular components(P<0.01).In vitro experiments revealed that Ti-PDA@SNP-OGP not only facilitated osteogenic differentiation of MSCs,but also promoted the polarization of pro-inflammatory M1 macrophages to the anti-inflammatory M2-phenotype(P<0.05 or P<0.01).The favorable osteo-immune microenvironment further facilitated osteogenesis of MSCs and the anti-inflammation of RAW264.7 cells via multiple paracrine signaling pathways(P<0.01).In vivo evaluation confirmed the aforementioned results and revealed that Ti-PDA@SNP-OGP induced ameliorative osseointegration in an MRSA-infected femoral defect implantation model(P<0.01).Conclusions:Ti-PDA@SNP-OGP is a promising multi-functional material for the high-efficient treatment of MRSA infections in implant replacement surgeries. 展开更多
关键词 Polydopamine nanoparticles Methicillin-resistant Staphylococcus aureus Nitric oxide OSSEOINTEGRATION Osteo-immunomodulation Photothermal effect Titanium implants
下载PDF
Glaucoma drainage device implantation and cyclophotocoagulation in the management of refractory glaucoma after Descemet-stripping automated endothelial keratoplasty
18
作者 Min-Shu Wang Xue-Chuan Dong +4 位作者 Mi-Yun Zheng Xiang Fan Ge-Ge Xiao Jing Hong Ling-Ling Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期257-264,共8页
AIM:To compare the surgical outcomes of glaucoma drainage device implantation(GDI)and trans-scleral neodymium:YAG cyclophotocoagulation(CPC)in the management of refractory glaucoma after Descemetstripping automated en... AIM:To compare the surgical outcomes of glaucoma drainage device implantation(GDI)and trans-scleral neodymium:YAG cyclophotocoagulation(CPC)in the management of refractory glaucoma after Descemetstripping automated endothelial keratoplasty(DSAEK).METHODS:This retrospective study on observational case series enrolled 29 patients who underwent DSAEK and posterior anti-glaucoma surgery(15 with GDI and 14 with CPC).The main outcome measures were intraocular pressure(IOP),glaucoma surgery success rate(defined as IOP of 6–21 mm Hg without additional anti-glaucoma operation),number of glaucoma medications,endothelial graft status,and best-corrected visual acuity(BCVA).RESULTS:The mean follow-up time was 34.1 and 21.0mo for DSAEK or glaucoma surgeries,both for the GDI and CPC groups.Both groups showed significant IOP reduction after glaucoma surgery.The GDI group presented a significantly higher success rate in IOP control than the CPC group(60%vs 21.4%,P=0.03).Both procedures significantly decreased the number of glaucoma medications(P=0.03).Forty percent and 57%of cases in the GDI and the CPC group,respectively,experienced endothelial graft failure during follow-up(P=0.36).Significantly worse BCVA after surgery was observed in the CPC group but not in the GDI group.CONCLUSION:Both GDI and CPC significantly decrease IOP in eyes with glaucoma after DSAEK.GDI is preferable to CPC in refractory glaucoma cases after DSAEK,as it manifests a significantly higher success rate for IOP control,similar endothelial graft failure rate,and relatively preserves BCVA than CPC. 展开更多
关键词 glaucoma drainage device implantation CYCLOPHOTOCOAGULATION refractory glaucoma Descemetstripping automated endothelial keratoplasty
下载PDF
Superior rectus/levator complex in acquired anophthalmic socket repaired with spheric implant—a computed tomography scan and topographic study
19
作者 Shaikha Al Eid Hamad M AlSulaiman +4 位作者 Sahar M Elkhamary Osama Al Sheikh Alicia Ferrero-Galindo Rajiv Kandekhar Silvana A Schellini 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第8期1483-1488,共6页
AIM:To determine whether the levator palpebrae superioris(LPS)/superior rectus(SR)muscle complex,can influence the position of the upper lid and fornix in acquired anophthalmic sockets.METHODS:This comparative non-ran... AIM:To determine whether the levator palpebrae superioris(LPS)/superior rectus(SR)muscle complex,can influence the position of the upper lid and fornix in acquired anophthalmic sockets.METHODS:This comparative non-randomized and non-interventional study included retrospective data of 21 patients with unilateral acquired anophthalmic sockets repaired with spheric implants.High-resolution computed tomography(CT)measurements of the LPM/SR muscle complex and clinical topographic position of the upper lid,superior and inferior fornix depth in primary gaze position were evaluated.Demographic data were presented as frequency and percentage proportions and quantitative variables comparing the socket measurements with the normal contralateral orbit was statistically analyzed using non-parametric tests considering P<0.05.RESULTS:The anophthalmic orbits had a significantly shorter LPS length(P=0.01)and significantly thicker SR(P=0.02)than the normal orbit.Lagophthalmos was present in anophthalmic sockets but not in normal orbits(P=0.002),while levator function was normal in both(P>0.05,all comparisons).The superior fornix depth was similar in the anophthalmic socket and the contralateral normal orbit(P=0.192)as well the inferior fornix depth(P=0.351).CONCLUSION:Acquired anophthalmic sockets repaired with spheric implants have shorter LPS,thicker SR,and more lagophthalmos than normal orbits.The relationship of the LPS and SR with other orbital structures,associated with passive or active forces acting in the final position of the lids and external ocular prosthesis should be further investigated. 展开更多
关键词 anophthalmic socket spheric implant levator palpebrae superioris superior rectus lagophthalmos fornix depth
下载PDF
In vivo and in vitro study of resorbable magnesium wires for medical implants:Mg purity,surface quality,Zn alloying and polymer coating
20
作者 K.Tesar J.Luňácková +12 位作者 M.Jex M.Žaloudková R.Vrbová M.Bartoš P.Klein L.Vištejnová J.Dušková E.Filová Z.Sucharda M.Steinerová S.Habr K.Balík A.Singh 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第6期2472-2488,共17页
Magnesium is an excellent material in terms of biocompatibility and its corrosion products can serve as an active source for new bone formation.However,localized corrosion and H_(2)generation limit the potential of Mg... Magnesium is an excellent material in terms of biocompatibility and its corrosion products can serve as an active source for new bone formation.However,localized corrosion and H_(2)generation limit the potential of Mg-based implants.Utilizing low-alloyed Mg-Zn wires can strongly reduce problems with large H_(2)bubbles and improve the mechanical properties considerably while maintaining excellent long-term biocompatibility.Acidic pickling and a polymer coating can be effectively used to lower the rate of in vivo degradation.In this work,microstructural,mechanical,and in vitro characterization of 250μm and 300μm extruded wires made from ultra-pure Mg,commercially pure Mg,Mg-0.15Zn,Mg-0.4Zn and Mg-1Zn was performed.Additionally,Mg-0.4Zn wires together with a variant coated with a copolymer of L-lactide andε-caprolactone were tested in vivo on artificially damaged Wistar rat femurs.Based on the observed Mg-induced osteogenesis,polymer-coated Mg wires with a small addition of Zn are a perspective material for bone-support applications,such as cerclage and fixation wires. 展开更多
关键词 MAGNESIUM Resorbable Mg wire Mg-Zn implant degradation Biocompatibility study Zn grain boundary segregation
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部