Bone defect repairs are based on bone graft fusion or replacement.Current large bone defect treatments are inadequate and lack of reliable technology.Therefore,we aimed to investigate a simple technique using three-di...Bone defect repairs are based on bone graft fusion or replacement.Current large bone defect treatments are inadequate and lack of reliable technology.Therefore,we aimed to investigate a simple technique using three-dimensional(3D)-printed individualized porous implants without any bone grafts,osteoinductive agents,or surface biofunctionalization to treat large bone defects,and systematically study its long-term therapeutic effects and osseointegration characteristics.Twenty-six patients with large bone defects caused by tumor,infection,or trauma received treatment with individualized porous implants;among them,three typical cases underwent a detailed study.Additionally,a large segmental femur defect sheep model was used to study the osseointegration characteristics.Immediate and long-term biomechanical stability was achieved,and the animal study revealed that the bone grew into the pores with gradual remodeling,resulting in a long-term mechanically stable implant-bone complex.Advantages of 3D-printed microporous implants for the repair of bone defects included 1)that the stabilization devices were immediately designed and constructed to achieve early postoperative mobility,and 2)that osseointegration between the host bone and implants was achieved without bone grafting.Our osseointegration method,in which the“implant-bone”interface fusion concept was used instead of“bone-bone”fusion,subverts the traditional idea of osseointegration.展开更多
A dual-mode mechanical resonator using an atomic force microscope (AFM) as a force sensor is developed. The resonator consists of a long vertical glass fiber with one end glued onto a rectangular cantilever beam and...A dual-mode mechanical resonator using an atomic force microscope (AFM) as a force sensor is developed. The resonator consists of a long vertical glass fiber with one end glued onto a rectangular cantilever beam and the other end immersed through a liquid-air interface. By measuring the resonant spectrum of the modified AFM cantilever, one is able to accurately determine the longitudinal friction coefficient ξv along the fiber axis associated with the vertical oscillation of the hanging fiber and the traversal friction coefficient ξh perpendicular to the fiber axis associated with the horizontal swing of the fiber around its joint with the cantilever. The technique is tested by measurement of the friction coefficient of a fluctuating (and slipping) contact line between the glass fiber and the liquid interface. The experiment verifies the theory and demonstrates its applications. The dual-mode mechanical resonator provides a powerful tool for the study of the contact line dynamics and the rheological property of anisotropic fluids.展开更多
基金the grant from the Ministry of Science and Technology of the People’s Republic of China(grant number 2016YFB1101501)Beijing Municipal Science&Technology Commission(Project Z181100001718195)。
文摘Bone defect repairs are based on bone graft fusion or replacement.Current large bone defect treatments are inadequate and lack of reliable technology.Therefore,we aimed to investigate a simple technique using three-dimensional(3D)-printed individualized porous implants without any bone grafts,osteoinductive agents,or surface biofunctionalization to treat large bone defects,and systematically study its long-term therapeutic effects and osseointegration characteristics.Twenty-six patients with large bone defects caused by tumor,infection,or trauma received treatment with individualized porous implants;among them,three typical cases underwent a detailed study.Additionally,a large segmental femur defect sheep model was used to study the osseointegration characteristics.Immediate and long-term biomechanical stability was achieved,and the animal study revealed that the bone grew into the pores with gradual remodeling,resulting in a long-term mechanically stable implant-bone complex.Advantages of 3D-printed microporous implants for the repair of bone defects included 1)that the stabilization devices were immediately designed and constructed to achieve early postoperative mobility,and 2)that osseointegration between the host bone and implants was achieved without bone grafting.Our osseointegration method,in which the“implant-bone”interface fusion concept was used instead of“bone-bone”fusion,subverts the traditional idea of osseointegration.
基金supported by the Research Grants Council of Hong Kong,China(Grant Nos.605013,604211,and SRFI11/SC02)the National Natural Science Foundation of China(Grand Nos.10974259 and 11274391)
文摘A dual-mode mechanical resonator using an atomic force microscope (AFM) as a force sensor is developed. The resonator consists of a long vertical glass fiber with one end glued onto a rectangular cantilever beam and the other end immersed through a liquid-air interface. By measuring the resonant spectrum of the modified AFM cantilever, one is able to accurately determine the longitudinal friction coefficient ξv along the fiber axis associated with the vertical oscillation of the hanging fiber and the traversal friction coefficient ξh perpendicular to the fiber axis associated with the horizontal swing of the fiber around its joint with the cantilever. The technique is tested by measurement of the friction coefficient of a fluctuating (and slipping) contact line between the glass fiber and the liquid interface. The experiment verifies the theory and demonstrates its applications. The dual-mode mechanical resonator provides a powerful tool for the study of the contact line dynamics and the rheological property of anisotropic fluids.