期刊文献+
共找到294篇文章
< 1 2 15 >
每页显示 20 50 100
Class III Reversion with Immediate Complete Denture and Immediate Implant-Retained Overdenture: Case Report
1
作者 Giovanna Lima Costa Barcelos Rafaella de Oliveira Matiolo +2 位作者 Sérgio Carvalho Costa Cláudia Lopes Brilhante Bhering José Augusto César Discacciati 《Open Journal of Stomatology》 2020年第12期372-382,共11页
With the increased life expectancy, complete dentures have been used in the treatment of edentulism<span> </span><span>progressively. It restores stomatognathic system functions, providing improvemen... With the increased life expectancy, complete dentures have been used in the treatment of edentulism<span> </span><span>progressively. It restores stomatognathic system functions, providing improvements in chewing, aesthetics, and phonetics. The aim was to report an oral rehabilitation of a patient with severe aesthetic and functional impairment, with Angle’s class III malocclusion. The patient sought the extension project of the School of Dentistry of the Federal University of Minas Gerais with aesthetic complaints. After clinical and radiographic evaluation, the proposed planning was immediate complete denture maxilla and immediate implant-retained overdenture in mandible. During clinical evaluation it was observed that the patient was Angle</span><span>’</span><span>s III. The rehabilitation was performed as proposed and at the end of the treatment, it was possible to revert the class III occlusal pattern to Angle’s I. The excellent maxillomandibular relationship was achieved, which ensured optimal facial aesthetics and functional condition. It was concluded that the immediate complete dentures and immediate implant-retained overdenture might be beneficial for restoring the aesthetics and function of patients with Angle’s class III malocclusion.</span> 展开更多
关键词 Dental Prosthesis Immediate Complete Denture overdenture Dental Implants Dental Occlusion
下载PDF
An in vitro Investigation into Retention Strength and Fatigue Resistance of Various Designs of Tooth/Implant Supported Overdentures 被引量:2
2
作者 Abdalbseet A Fatalla 宋珂 +1 位作者 杜田丰 曹颖光 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2012年第1期124-129,共6页
Previously, the choice of prosthetic implant-retained overdentures has depended on data from previous studies about the retention-fatigue strength of the attachment system selected. Little or no data have been availab... Previously, the choice of prosthetic implant-retained overdentures has depended on data from previous studies about the retention-fatigue strength of the attachment system selected. Little or no data have been available on the correlation between the attachment system selected and the overdenture support configuration. The purpose of the present study was to evaluate the retention force and fatigue resistance of three attachment systems and four support designs of overdenture prosthesis. Four lower edentulous acrylic models were prepared and eight combinations of attachments groups were investigated in the study. These included: O-Rings with mini-dental implants (MDIs), Dalbo elliptic with Dalbo Rotex and fabricated flexible acrylic attachments with both MDI and Dalbo Rotex. The study was divided into four test groups: groups A and B, controls, and groups C and D, experimental groups. Control group A contained three overdenture supports: two free standing MDIs in the canine region and at the midline, and one simulated tooth root with Dalbo Rotex screwed in. Control group B contained four overdenture support foundations: two free standing MDIs in the right canine region and the first premolar region, and two simulated tooth roots with Dalbo Rotex screwed in at the same MDI position, but on the left side of the model. Experimental group C contained three overdenture support foundations: two free standing MDIs in the canine region and at the midline, and one simulated tooth root with MDI screwed in. Experimental group D contained four overdenture support foundations: two free standing MDIs in the right canine region and the first premolar region, and two simulated tooth roots with MDIs screwed in at the same MDI position, but on the left side of the model. Each group was further divided into two subgroups according to attachment type used. Five samples were prepared for each group. Retention force (N) values were recorded initially (0 cycles) and after 360, 720, 1440 and 2880 insertion and removal cycles. During the tensile test a cross-head speed of 10 mm/min was applied. Values of absolute force (AF) and relative force (RF) were statistically analyzed by two-way ANOVA and multiple comparison Tukey’s tests between groups and cycles periods. The results of fatigue tests showed a 50% reduction in retention force in the subgroups with flexible attachments. A triangular design of overdenture support foundations with O-Ring attachments revealed the lowest value of AF and a relatively high reduction in RF. The four overdenture support designs with flexible acrylic attachments improved the retention force and reduced the fatigue retention. Furthermore, the results of the investigation demonstrate that flexible acrylic attachments for both teeth and implant-supported overdentures offer a wide range of retention forces. 展开更多
关键词 mini-dental implant simulated tooth flexible acrylic overdenture attachments overdenture retention
下载PDF
A novel bio-sensor for registration of biting force in occlusally reactive single mandibular implant overdenture
3
作者 Fahad H. Banasr Manal R. Alammari 《Open Journal of Stomatology》 2013年第7期370-378,共9页
Mandibular single denture opposed by maxillary natural dentition showed a great problem. However, mandibular implant overdenture treatment has gained considerable recognition. Ten male patients with complete mandibula... Mandibular single denture opposed by maxillary natural dentition showed a great problem. However, mandibular implant overdenture treatment has gained considerable recognition. Ten male patients with complete mandibular edentulous arch and opposing arch have full natural dentition. Patients were divided into two groups. All patients received two endosseous titanium implants. In Group I, patients were rehabilitated with conventional implant retained overdentures. While in Group II, Patients were rehabilitated with occlusal reactive implant overdentures. A Novel proposed biosensor was used to measure the amount of biting force on the implant retained overdenture. Quantitative electromyographic (EMG) signals of the masseter and anterior fibers of temporalis muscles were recorded, filtered and directly interfaced with a computer to represent the data graphically. The mean amplitude (μV), turn, and activity were recorded at the baseline and after three months. The results revealed an increase in the muscle activity in group II after three months as compared to group I. Significant difference in bilateral biting force at the premolar-molar area was found between group I and group II after three months. This study concluded that a resilient implant overdenture denture could be a desirable treatment in mandibular overdenture supported by two implants with resilient attachment and opposing natural dentition due to its easy fabrication and durability in use and increased muscle activity. 展开更多
关键词 Bio-Sensor BITING Force MANDIBULAR IMPLANT Resilient overdenture
下载PDF
Swallowing threshold parameters of subjects with complete dentures and overdentures
4
作者 Dick. J. Witter F. Anneke Tekamp +2 位作者 Ad P. Slagter Cees M. Kreulen Nico H. J. Creugers 《Open Journal of Stomatology》 2011年第3期69-74,共6页
Aim: To compare the chewing process and swallowing threshold parameters of subjects with complete dentures and overdentures with data obtained from subjects with complete natural dentitions. Metho-dology: The chewing ... Aim: To compare the chewing process and swallowing threshold parameters of subjects with complete dentures and overdentures with data obtained from subjects with complete natural dentitions. Metho-dology: The chewing process in terms of swallowing threshold parameters of four groups of subjects with complete dentures (all females) was quantified by sieving particles after chewing of an artificial test ‘food’ and compared with that of subjects with com-plete natural dentitions as a reference group (33 sub-jects). All subjects (except those of the reference group) had a complete denture in the upper jaw. Regarding the lower jaw two groups with complete dentures (with high (24 subjects), respectively low mandible (12 subjects)) and two groups with overdentures (implant-retained (22 subjects), respectively natural root supported (19 subjects)) were composed. Results: The ‘overdenture-implants’ group needed significantly more chewing cycles and time (mean: 45 cycles in 32 seconds) until ‘swallowing’ compared to the group with complete natural dentitions (mean: 26 cycles in 19 seconds until ‘swallowing’). Also the ‘complete denture-low mandible’ group needed sig-nificantly more cycles and time (mean: 52 cycles in 44 seconds) until ‘swallowing’ than the complete dentition group. In the ‘overdenture-natural roots’ group these outcomes (33 cycles in 24 seconds) were not significantly different compared with the complete dentition group. The ‘complete denture-high mandi-ble’ group (32 cycles in 26 seconds) needed not sig-nificantly more cycles until ‘swallowing’, however time until ‘swallowing’ was significantly longer com-pared to the complete dentition group. All denture groups had significantly larger mean particle sizes when ‘swallowing’ (sizes in the order of 3 mm) than the natural dentition group (about 2 mm). Conclusion: Despite efforts to compensate for a reduced chewing efficiency, subjects with complete dentures (including overdentures) had 50% larger median particle sizes when ‘swallowing’ compared to subjects with complete natural dentitions. 展开更多
关键词 SWALLOWING THRESHOLD CHEWING Efficiency Complete DENTURE overdenture Oral Implant
下载PDF
Biomechanical Analysis of Implant Assisted-Overdentures with Variations in the Attachments Systems
5
作者 Eduardo Vedovatto Jose Vitor Quinelli Mazaro +3 位作者 Humberto Gennari Filho Paulo Sérgio Perri de Carvalho Caroline Cantieri de Mello Cleidiel Aparecido Araujo Lemos 《Materials Sciences and Applications》 2015年第8期734-742,共9页
The aim of this study was to assess the stress patterns on the peri-implant zone and residual alveolar ridge in different overdenture attachment system designs by the photoelasticity method. Four attachments systems w... The aim of this study was to assess the stress patterns on the peri-implant zone and residual alveolar ridge in different overdenture attachment system designs by the photoelasticity method. Four attachments systems were tested: O-ring, ERA, Bar-clip, and Bar-clip/O-ring association. The prostheses were loaded with 100 N in five pre-determined points and the photoelastic model was evaluated by a circular polariscope. The anterior load, O-ring, and ERA showed better stress distribution in relation to the bars systems, which presented stress levels surrounding implants. The molar load, Bar-clip/O-ring association, presented the biggest stress concentration on the peri-implant region in relation to the others. When the second molar was loaded, there was a concentration of stress in the alveolar ridge in all situations analyzed. Within the limitation of this “in vitro” study, it could be concluded that there were biomechanical differences among the attachments systems analyzed, principally between isolated and the bars systems. The O-ring showed better stress distribution and the Bar-clip/O-ring showed higher stress concentration. 展开更多
关键词 DENTAL IMPLANTS Complete DENTURE overdentureS
下载PDF
舌侧金属加强杆种植覆盖义齿的三维有限元分析
6
作者 张馨月 王勇 +4 位作者 陈倩 周团锋 马珂楠 王子轩 赵一姣 《医用生物力学》 CAS CSCD 北大核心 2024年第3期532-538,共7页
目的 通过三维有限元分析探讨舌侧金属加强结构义齿基托设计对无牙下颌种植修复义齿的生物力学影响,为无牙颌修复治疗提供参考。方法 构建舌侧金属加强结构与无加强结构两种义齿基托设计的2颗种植体支持Locator式覆盖义齿三维有限元模型... 目的 通过三维有限元分析探讨舌侧金属加强结构义齿基托设计对无牙下颌种植修复义齿的生物力学影响,为无牙颌修复治疗提供参考。方法 构建舌侧金属加强结构与无加强结构两种义齿基托设计的2颗种植体支持Locator式覆盖义齿三维有限元模型,分别对后牙中央窝垂直施加150 N载荷、斜向施加150 N载荷以及对前牙垂直施加150 N载荷,模拟正中咬合、左右侧方咀嚼以及前牙切割食物时两种模型各组织的受力情况。结果 后牙及前牙垂直向加载时,两种义齿基托设计模型各组织的应力分布较为接近,所受最大应力差别在0~0.16 MPa之间;偏侧咀嚼时,未添加金属加强杆的义齿基托、种植体和黏骨膜应力集中范围,以及种植体、种植体周围骨最大受力明显大于添加金属加强杆模型,所受最大应力差别在0.59~2.99 MPa之间。结论 在义齿基托舌侧添加金属加强杆,可以起到应力分散的作用,或可在一定程度上减小骨吸收及基托折断的风险。 展开更多
关键词 覆盖义齿 种植体 义齿基托 有限元分析
下载PDF
48例Locator种植覆盖全口义齿5年临床修复效果评价
7
作者 周团锋 杨雪 +2 位作者 张华 张智勇 陈全 《上海口腔医学》 CAS 2024年第1期90-96,共7页
目的:观察Locator按扣式种植覆盖全口义齿的长期临床修复效果。方法:选择2016—2017年北京大学口腔医院门诊部采用Locator按扣式种植覆盖全口义齿修复的无牙颌患者48例,其中双颌全口义齿修复21例,单颌27例,共植入种植体230颗。观察种植... 目的:观察Locator按扣式种植覆盖全口义齿的长期临床修复效果。方法:选择2016—2017年北京大学口腔医院门诊部采用Locator按扣式种植覆盖全口义齿修复的无牙颌患者48例,其中双颌全口义齿修复21例,单颌27例,共植入种植体230颗。观察种植体的留存率、种植体周黏膜探诊出血(BOP)、种植体周牙槽骨垂直吸收高度变化、义齿基托折裂和人工牙脱落折断等并发症,以及义齿固位力变化等。采用SPSS 13.0软件包对数据进行统计学分析。结果:在5年观察期间,5颗种植体脱落,1颗前牙区窄颈种植体颈部折断,12颗失访,种植体存留率为97.25%。种植修复后1年,48颗种植体周黏膜探诊出血(BOP+)(21.4%),平均出血指数(BI)为0.21±0.42,前牙区高于后牙区。种植体周牙槽骨垂直吸收高度为(0.21±0.35) mm,义齿基托折断2例。修复后5年,163颗种植体周黏膜探诊出血(BOP+)(76.89%),BI为1.00±0.70,种植体周牙槽骨垂直吸收高度为(0.58±0.85) mm;种植体周黏膜探诊出血指数与牙槽骨垂直吸收高度在男女之间、前牙区与后牙区之间均无统计学差异(P>0.05)。1年观察期和5年观察期间,种植体周黏膜平均出血指数、种植体周牙槽骨垂直吸收高度前后比较有显著差异(P<0.01)。义齿折裂17例,折裂率为26.15%,人工牙脱落折断率为16.92%,多发于前牙中线区及Locator基台附着体安放位置,因固位力下降首次更换Locator基台固位垫圈平均(34.2±10.3)个月。结论:Locator按扣式种植覆盖全口义齿有良好的临床修复效果。并发症多见于种植体周黏膜探诊出血和垂直向骨吸收,随着戴用时间延长有逐渐加重的趋势。其次是义齿基托折裂及人工牙脱落与折断,种植体脱落及折断。提示义齿制作时应加强金属支架在Locator基台位置和前牙中线区的强度,前牙区尽量避免使用窄径种植体。 展开更多
关键词 种植牙 无牙颌 覆盖全口义齿 出血指数 牙槽骨吸收
下载PDF
p38MAPK在周期性压应力下对颌骨成骨细胞分化的作用
8
作者 杜启翠 苏林旺 +1 位作者 杭晨 郭娜 《中华老年口腔医学杂志》 2023年第4期193-197,241,共6页
目的探讨p38丝裂原活化蛋白激酶(p38 mitogen activated protein kinases,p38 MAPK)在周期性压应力作用下对无牙颌种植覆盖义齿牙槽嵴成骨细胞分化中的作用机制,为无牙颌骨组织的改建和种植覆盖义齿修复提供理论依据。方法构建无牙颌牙... 目的探讨p38丝裂原活化蛋白激酶(p38 mitogen activated protein kinases,p38 MAPK)在周期性压应力作用下对无牙颌种植覆盖义齿牙槽嵴成骨细胞分化中的作用机制,为无牙颌骨组织的改建和种植覆盖义齿修复提供理论依据。方法构建无牙颌牙槽嵴成骨细胞力学刺激模型,采用简单随机抽样法将力学刺激模型分为对照组(15%压应力)和阻断组(15%压应力+阻断剂)。加载参数设定为细胞拉伸形变率15%,加力时间均为6 h、12 h、24 h。CCK-8检测牙槽骨成骨细胞增殖活性;Western-blotting检测p38 MAPK差异性表达,q PCR检测碱性磷酸酶(Alkaline phosphatase,ALP)和破骨细胞分化因子(Receptor activator of nuclear factor-κB ligand,RANKL)的差异性表达变化。结果15%压应力使得牙槽嵴成骨细胞增殖活性增加,加力12 h细胞增殖活性最高;对照组加力12 h后,P-p38MAPK蛋白、ALP mRNA、RANKL mRNA的分别表达量均明显过于6 h(P<0.05);加力24 h P-p38MAPK蛋白表达量均比6 h、12 h显著升高(P<0.05);加力24 h ALP mRNA、RANKL mRNA的表达量比6 h显著升高(P<0.05),比12 h有一定程度升高(P>0.05)。阻断组加力6 h、12 h、24 h P-p38MAPK蛋白、ALP mRNA、RANKL mRNA的表达量分别均明显低于对照组相应的时间点(P<0.05)。结论p38MAPK信号转导通路参与了周期性压应力下无牙颌种植覆盖义齿牙槽嵴成骨细胞分化的过程,参与无牙颌种植覆盖义齿修复骨组织改建过程。 展开更多
关键词 P38MAPK 无牙颌 种植覆盖义齿 周期性压应力 细胞分化
下载PDF
先天缺牙患儿活动和种植修复1例
9
作者 李娇 张杰 +1 位作者 李梦雪 周毅 《口腔医学研究》 CAS CSCD 北大核心 2023年第1期89-91,共3页
先天缺牙影响儿童生长颌面部发育,需要早期对患儿进行包括义齿修复在内的多学科序列治疗,保障软硬组织有足够的力学刺激。本文报道1例先天缺牙患儿序列治疗中通过活动义齿和种植义齿进行缺失牙修复的阶段治疗过程。
关键词 先天缺牙 活动义齿 种植覆盖义齿
下载PDF
种植覆盖义齿与固定义齿治疗无牙颌患者的效果比较
10
作者 张世锋 《河南医学研究》 CAS 2023年第5期826-829,共4页
目的对比种植覆盖义齿与固定义齿治疗无牙颌患者的效果。方法回顾性分析2018年7月至2020年9月郑州市第三人民医院收治的62例无牙颌患者,并根据采用的种植修复方案进行分组,将接受种植固定义齿修复的患者纳入对照组(30例),将接受种植覆... 目的对比种植覆盖义齿与固定义齿治疗无牙颌患者的效果。方法回顾性分析2018年7月至2020年9月郑州市第三人民医院收治的62例无牙颌患者,并根据采用的种植修复方案进行分组,将接受种植固定义齿修复的患者纳入对照组(30例),将接受种植覆盖义齿修复的患者纳入观察组(32例),因失访退出研究2例,最终完成研究30例。修复完成后随访1 a,行常规修复体检查与效果评价,测定菌斑指数、骨吸收、修复体成功率、患者满意度评分、口腔健康相关生命质量。结果两组修复完成后1 a的菌斑指数比较,差异无统计学意义(P>0.05);种植术后3个月、修复治疗后1 a,两组骨吸收情况比较,差异无统计学意义(P>0.05)。对比两组修复体成功率,差异无统计学意义(P>0.05)。两组固位、发音、咀嚼、舒适评分比较,差异无统计学意义(P>0.05);观察组美观、总体满意度评分高于对照组,差异有统计学意义(P<0.05);随访1 a,观察组口腔影响程度量表(OHIP-14)中文版评分中Q1、Q5、Q7评分及总分比对照组低,Q6、Q10评分比对照组高,差异有统计学意义(P<0.05)。结论种植覆盖义齿与固定义齿均可有效治疗无牙颌患者,成功率较高,其中种植覆盖义齿患者的美观及总体满意度评分较高,并可提高患者的口腔健康相关生命质量。 展开更多
关键词 无牙颌 种植体 覆盖义齿 固定义齿
下载PDF
种植覆盖义齿与种植固定义齿对无牙颌患者的临床疗效
11
作者 邵一博 贾斌 黄世冲 《当代医学》 2023年第8期128-131,共4页
目的探究种植覆盖义齿与种植固定义齿对无牙颌患者的临床疗效。方法选取2018年10月至2020年5月本院收治的84例无牙颌患者作为研究对象,依照患者入院先后顺序分为两组,每组42例。覆盖组行种植覆盖义齿治疗,固定组行种植固定义齿治疗,比... 目的探究种植覆盖义齿与种植固定义齿对无牙颌患者的临床疗效。方法选取2018年10月至2020年5月本院收治的84例无牙颌患者作为研究对象,依照患者入院先后顺序分为两组,每组42例。覆盖组行种植覆盖义齿治疗,固定组行种植固定义齿治疗,比较两组种植体周围的菌斑指数及种植成功率,探诊龈沟出血情况,评估两组患者的口腔健康主观感受。结果重复测量方差分析结果显示,修复后1、3、6个月,两组组间、时间、交互菌斑指数(PLI)评分及出血指数(BI)评分比较差异无统计学意义;组内比较:修复后1、3、6个月,两组PLI评分各时间点两两比较差异无统计学意义;修复后6个月,两组BI评分均低于修复后1个月(P<0.05),两组修复后3个月与修复后1、6个月比较差异均无统计学意义;组间比较:修复后1、3、6个月,两组PLI评分及BI评分比较差异均无统计学意义。覆盖组种植成功率(97.09%)稍高于固定组(95.86%),差异无统计学意义;覆盖组口腔健康影响程度量表(OHIP-14)评分低于固定组,差异有统计学意义(P<0.05)。结论无牙颌患者开展种植覆盖义齿和种植固定义齿治疗均有较显著效果,种植覆盖义齿治疗的患者主观感受较好、满意度更高,两种种植修复技术优缺点并存,在临床治疗中需要患者结合实际情况选择合适的修复方案。 展开更多
关键词 种植覆盖义齿 种植固定义齿 无牙颌 种植体成功率 口腔健康影响程度量表评分
下载PDF
Magfit磁性附着体在全口义齿修复中的应用 被引量:76
12
作者 赵铱民 邵龙泉 +2 位作者 林丽红 赵军 艾勇 《实用口腔医学杂志》 CAS CSCD 北大核心 1999年第6期422-425,共4页
评价以Magfit磁性附着体改善全口覆盖义齿固位的远期效果。方法:采用铸接法设置报面伤铁,并对应用Magfit磁性附着体的长期效果,如义齿的固位、稳定状态,以及义齿应用后出现的问题进行16~38月的随访观察。结果:①设置2只以上Magfit... 评价以Magfit磁性附着体改善全口覆盖义齿固位的远期效果。方法:采用铸接法设置报面伤铁,并对应用Magfit磁性附着体的长期效果,如义齿的固位、稳定状态,以及义齿应用后出现的问题进行16~38月的随访观察。结果:①设置2只以上MagfitEX600或设置3只以上MagfitEX400磁性附着体即可使全口覆盖义齿获得保证行使各种口腔功能所需的长期稳定的固位力;②铸接式衔铁较粘接式衔铁有更好的密合性,可有效地防止继发龋;③Co-Cr合金可以被用于待接式衔铁的制作;④应用MagfitEX系列磁性附着体的全口覆盖义齿戴用后并发症发生率较低。结论:Magfit磁性附着体,能有效改善全口覆盖义齿的固位,并发症少,具有良好的远期效果。 展开更多
关键词 磁力学 覆盖义齿 义齿固位 义齿 修复
下载PDF
MAGFIT磁性附着体的临床应用及疗效观察 被引量:13
13
作者 张洁 宋雍康 +1 位作者 骆小平 王岚 《口腔医学研究》 CAS CSCD 2003年第5期395-397,共3页
目的 :观察Magfit磁性附着体用于全口覆盖义齿和可摘局部覆盖义齿的修复疗效。方法 :为 2 0名患者制作 31只Magfit磁性附着体 ,对义齿的固位 ,咀嚼和使用情况进行为期 2年的随访观察。结果 :31只磁性附着体均在正常使用 ,其义齿的固位... 目的 :观察Magfit磁性附着体用于全口覆盖义齿和可摘局部覆盖义齿的修复疗效。方法 :为 2 0名患者制作 31只Magfit磁性附着体 ,对义齿的固位 ,咀嚼和使用情况进行为期 2年的随访观察。结果 :31只磁性附着体均在正常使用 ,其义齿的固位力 ,稳定性 ,咀嚼功能良好 ,基牙健康。结论 :Magfit磁性附着体能提高义齿的固位力及咀嚼效率 ,缩短义齿的适应期 ,保护基牙的健康 ,美观效果好 。 展开更多
关键词 MAGFIT磁性附着体 临床应用 疗效观察 全口覆盖义齿
下载PDF
磁性附着体覆盖义齿修复牙列缺损的临床应用 被引量:12
14
作者 吴利军 王雪 张广耘 《口腔医学研究》 CAS CSCD 北大核心 2010年第2期259-261,共3页
目的:探讨磁性附着体覆盖义齿在临床修复中的制作方法及疗效。方法:对修复科68例牙列缺损患者行磁性附着体覆盖义齿,观察其固位力和咀嚼效率。结果:安放磁体后义齿的固位力及咀嚼效率显著大于磁体粘固前(P<0.05)。结论:磁性附着体覆... 目的:探讨磁性附着体覆盖义齿在临床修复中的制作方法及疗效。方法:对修复科68例牙列缺损患者行磁性附着体覆盖义齿,观察其固位力和咀嚼效率。结果:安放磁体后义齿的固位力及咀嚼效率显著大于磁体粘固前(P<0.05)。结论:磁性附着体覆盖义齿能有效地利用残冠残根,且制作简便、美观耐用,具有广泛的应用前景。 展开更多
关键词 磁性附着体 覆盖义齿 固位力 咀嚼效率
下载PDF
磁性附着体在全口覆盖义齿的临床应用 被引量:21
15
作者 沈倍勇 郑苍尚 周琦 《中国现代医学杂志》 CAS CSCD 北大核心 2005年第12期1857-1859,共3页
目的评价磁性附着体的临床应用效果。方法用53个Magtit磁性附着体为18名患者制做25件总义齿,进行12~18个月的随访观察。结果19件总义齿采用了2~4枚磁体的总义齿,固位效果满意或良好;6件采用了1枚磁体的总义齿,固位也得到改善。结论磁... 目的评价磁性附着体的临床应用效果。方法用53个Magtit磁性附着体为18名患者制做25件总义齿,进行12~18个月的随访观察。结果19件总义齿采用了2~4枚磁体的总义齿,固位效果满意或良好;6件采用了1枚磁体的总义齿,固位也得到改善。结论磁性附着体对改善义齿的功能有显著作用。 展开更多
关键词 覆盖义齿 磁性附着体 固位力
下载PDF
磁性附着体在下颌全口覆盖义齿中的临床应用 被引量:85
16
作者 肖雪 冯海兰 《华西口腔医学杂志》 CAS CSCD 北大核心 2000年第4期232-234,共3页
目的 :观察磁性附着体的临床应用效果。方法 :用MagfitEX 6 0 0磁性附着体为 10名患者制作下颌全口覆盖义齿 ,粘固磁体前后进行固位力和咀嚼效率测试 ,并观察基牙情况。结果 :粘固磁体后固位力及咀嚼效率明显提高 ,观察的 6个月内 ,基... 目的 :观察磁性附着体的临床应用效果。方法 :用MagfitEX 6 0 0磁性附着体为 10名患者制作下颌全口覆盖义齿 ,粘固磁体前后进行固位力和咀嚼效率测试 ,并观察基牙情况。结果 :粘固磁体后固位力及咀嚼效率明显提高 ,观察的 6个月内 ,基牙松动度和牙周指标明显好转。结论 :磁性附着体对改善义齿的功能有显著作用。 展开更多
关键词 下颌全口 覆盖义齿 磁性附着体 固位力
下载PDF
种植覆盖总义齿的满意度分析 被引量:21
17
作者 黄建生 周磊 +3 位作者 宋光保 黄云飞 徐淑兰 张雪洋 《口腔颌面修复学杂志》 2002年第4期240-242,共3页
目的:了解种植覆盖总义齿患者对修复体的满意度。方法:共完成38件种植覆盖总义齿,在该研究中应用满意度的问卷调查,以分析种植覆盖总义齿的合理性和稳定性。结果:患者对种植覆盖总义齿的固位、舒适和咀嚼效能满意度较旧义齿明显提高。结... 目的:了解种植覆盖总义齿患者对修复体的满意度。方法:共完成38件种植覆盖总义齿,在该研究中应用满意度的问卷调查,以分析种植覆盖总义齿的合理性和稳定性。结果:患者对种植覆盖总义齿的固位、舒适和咀嚼效能满意度较旧义齿明显提高。结论: 种植覆盖总义齿的临床效果满意。 展开更多
关键词 种植覆盖总义齿 满意度 临床应用 全口牙缺失
下载PDF
孤立尖牙与单个种植体套筒冠覆盖义齿修复上颌牙列缺损1例 被引量:8
18
作者 赵海红 王鹏 +1 位作者 周军 杨英双 《华西口腔医学杂志》 CAS CSCD 北大核心 2012年第6期659-661,共3页
1例上颌牙列缺损患者,仅余A3,在B3区植入种植体1颗,利用A3和种植体支持制作套筒冠覆盖义齿修复。义齿修复后患者取戴自如,异物感小,固位力好,恢复了患者的咀嚼功能,保证了基牙和种植体周围软硬组织健康,患者对修复效果满意。研究证明利... 1例上颌牙列缺损患者,仅余A3,在B3区植入种植体1颗,利用A3和种植体支持制作套筒冠覆盖义齿修复。义齿修复后患者取戴自如,异物感小,固位力好,恢复了患者的咀嚼功能,保证了基牙和种植体周围软硬组织健康,患者对修复效果满意。研究证明利用孤立尖牙和单个种植体制作套筒冠覆盖义齿修复的方法是可行的,临床效果满意。 展开更多
关键词 尖牙 套筒冠 覆盖义齿
下载PDF
种植体-杆卡式附着体固位的覆盖全口义齿 被引量:9
19
作者 赵铱民 刘宝林 +3 位作者 马轩祥 张铁 赵军 邵龙泉 《华西口腔医学杂志》 CAS CSCD 北大核心 1999年第4期338-340,共3页
目的:总结和评价种植体-杆卡式附着体在覆盖全口义齿中的应用经验和效果。方法:将种植体与杆卡式附着体结合,以粘膜支持式、混合支持式和种植体支持式3种设计形式,为46例患者制作种植式全口覆盖义齿,并检查义齿的固位力和稳定性;同时采... 目的:总结和评价种植体-杆卡式附着体在覆盖全口义齿中的应用经验和效果。方法:将种植体与杆卡式附着体结合,以粘膜支持式、混合支持式和种植体支持式3种设计形式,为46例患者制作种植式全口覆盖义齿,并检查义齿的固位力和稳定性;同时采用修复体测力仪对其中15例患者义齿的固位效果进行定量评价。结果:3种设计均可达到良好的固位效果,其中混合支持式和种植体支持式的稳定、支持效果更好;应用2~3只尼龙卡可分别为覆盖义齿提供10~15N的固位力。结论:种植体-杆卡式附着体固位的全口覆盖义齿是无牙颌修复的非常有效的方式。 展开更多
关键词 种植体 杆卡式附着体 覆盖全口义齿 义齿
下载PDF
全下颌牙种植义齿及支持组织应力的三维有限元分析Ⅵ.不同上部结构对覆盖种植义齿应力分布的影响 被引量:11
20
作者 何佳凝 岑远坤 +1 位作者 毛祥彦 宫苹 《华西口腔医学杂志》 CAS CSCD 北大核心 1997年第1期67-69,共3页
采用三维有限元方法 ,考察了不同的上部结构设计 ,包括套筒冠、杆卡式附着体、改良杆卡式附着体对全下颌种植覆盖义齿及其支持组织在正中情况下应力分布的影响。结果发现杆卡式附着体的使用可降低种植体及剩余牙槽嵴表面的应力 ,但使... 采用三维有限元方法 ,考察了不同的上部结构设计 ,包括套筒冠、杆卡式附着体、改良杆卡式附着体对全下颌种植覆盖义齿及其支持组织在正中情况下应力分布的影响。结果发现杆卡式附着体的使用可降低种植体及剩余牙槽嵴表面的应力 ,但使界面应力增加。改良杆卡式附着体不利于种植体及骨界面的应力分布。 展开更多
关键词 义齿 种植体 有限元分析 应力
下载PDF