期刊文献+
共找到295篇文章
< 1 2 15 >
每页显示 20 50 100
Challenges and Suggestions of Ethical Review on Clinical Research Involving Brain-Computer Interfaces
1
作者 Xue-Qin Wang Hong-Qiang Sun +3 位作者 Jia-Yue Si Zi-Yan Lin Xiao-Mei Zhai Lin Lu 《Chinese Medical Sciences Journal》 CAS CSCD 2024年第2期131-139,共9页
Brain-computer interface(BCI)technology is rapidly advancing in medical research and application.As an emerging biomedical engineering technology,it has garnered significant attention in the clinical research of brain... Brain-computer interface(BCI)technology is rapidly advancing in medical research and application.As an emerging biomedical engineering technology,it has garnered significant attention in the clinical research of brain disease diagnosis and treatment,neurological rehabilitation,and mental health.However,BCI also raises several challenges and ethical concerns in clinical research.In this article,the authors investigate and discuss three aspects of BCI in medicine and healthcare:the state of international ethical governance,multidimensional ethical challenges pertaining to BCI in clinical research,and suggestive concerns for ethical review.Despite the great potential of frontier BCI research and development in the field of medical care,the ethical challenges induced by itself and the complexities of clinical research and brain function have put forward new special fields for ethics in BCI.To ensure"responsible innovation"in BCI research in healthcare and medicine,the creation of an ethical global governance framework and system,along with special guidelines for cutting-edge BCI research in medicine,is suggested. 展开更多
关键词 brain-computer interface clinical research BIOETHICS ethical governance ethical review
下载PDF
Double Deep Q-Network Decoder Based on EEG Brain-Computer Interface
2
作者 REN Min XU Renyu ZHU Ting 《ZTE Communications》 2023年第3期3-10,共8页
Brain-computer interfaces(BCI)use neural activity as a control signal to enable direct communication between the human brain and external devices.The electrical signals generated by the brain are captured through elec... Brain-computer interfaces(BCI)use neural activity as a control signal to enable direct communication between the human brain and external devices.The electrical signals generated by the brain are captured through electroencephalogram(EEG)and translated into neural intentions reflecting the user’s behavior.Correct decoding of the neural intentions then facilitates the control of external devices.Reinforcement learning-based BCIs enhance decoders to complete tasks based only on feedback signals(rewards)from the environment,building a general framework for dynamic mapping from neural intentions to actions that adapt to changing environments.However,using traditional reinforcement learning methods can have challenges such as the curse of dimensionality and poor generalization.Therefore,in this paper,we use deep reinforcement learning to construct decoders for the correct decoding of EEG signals,demonstrate its feasibility through experiments,and demonstrate its stronger generalization on motion imaging(MI)EEG data signals with high dynamic characteristics. 展开更多
关键词 brain-computer interface(BCI) electroencephalogram(EEG) deep reinforcement learning(Deep RL) motion imaging(MI)generalizability
下载PDF
Non-invasive EEG-based brain-computer interfaces in patients with disorders of consciousness 被引量:1
3
作者 Emilia Mikoajewska Dariusz Mikoajewski 《Journal of Medical Colleges of PLA(China)》 CAS 2014年第2期109-114,共6页
Disorders of consciousness(DoCs) are chronic conditions resulting usually from severe neurological deficits. The limitations of the existing diagnosis systems and methodologies cause a need for additional tools for re... Disorders of consciousness(DoCs) are chronic conditions resulting usually from severe neurological deficits. The limitations of the existing diagnosis systems and methodologies cause a need for additional tools for relevant patients with DoCs assessment, including brain-computer interfaces(BCIs). Recent progress in BCIs' clinical applications may offer important breakthroughs in the diagnosis and therapy of patients with DoCs. Thus the clinical significance of BCI applications in the diagnosis of patients with DoCs is hard to overestimate. One of them may be brain-computer interfaces. The aim of this study is to evaluate possibility of non-invasive EEG-based brain-computer interfaces in diagnosis of patients with DOCs in post-acute and long-term care institutions. 展开更多
关键词 neurological disorders disorders of consciousness brain-computer interfaces EEG-based BCIs
下载PDF
A Survey on Machine Learning Algorithms in Little-Labeled Data for Motor Imagery-Based Brain-Computer Interfaces
4
作者 Yuxi Jia Feng Li +1 位作者 Fei Wang Yan Gui 《Journal of Information Hiding and Privacy Protection》 2019年第1期11-21,共11页
The Brain-Computer Interfaces(BCIs)had been proposed and used in therapeutics for decades.However,the need of time-consuming calibration phase and the lack of robustness,which are caused by little-labeled data,are res... The Brain-Computer Interfaces(BCIs)had been proposed and used in therapeutics for decades.However,the need of time-consuming calibration phase and the lack of robustness,which are caused by little-labeled data,are restricting the advance and application of BCI,especially for the BCI based on motor imagery(MI).In this paper,we reviewed the recent development in the machine learning algorithm used in the MI-based BCI,which may provide potential solutions for addressing the issue.We classified these algorithms into two categories,namely,and enhancing the representation and expanding the training set.Specifically,these methods of enhancing the representation of features collected from few EEG trials are based on extracting features of multiple bands,regularization,and so on.The methods of expanding the training dataset include approaches of transfer learning(session to session transfer,subject to subject transfer)and generating artificial EEG data.The result of these techniques showed the resolution of the challenges to some extent.As a developing research area,the study of BCI algorithms in little-labeled data is increasingly requiring the advancement of human brain physiological structure research and more transfer learning algorithms research. 展开更多
关键词 brain-computer interface electroencephalography(EEG) machine learning
下载PDF
A Hybrid Brain-Computer Interface for Closed-Loop Position Control of a Robot Arm 被引量:6
5
作者 Arnab Rakshit Amit Konar Atulya K.Nagar 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2020年第5期1344-1360,共17页
Brain-Computer interfacing(BCI)has currently added a new dimension in assistive robotics.Existing braincomputer interfaces designed for position control applications suffer from two fundamental limitations.First,most ... Brain-Computer interfacing(BCI)has currently added a new dimension in assistive robotics.Existing braincomputer interfaces designed for position control applications suffer from two fundamental limitations.First,most of the existing schemes employ open-loop control,and thus are unable to track positional errors,resulting in failures in taking necessary online corrective actions.There are examples of a few works dealing with closed-loop electroencephalography(EEG)-based position control.These existing closed-loop brain-induced position control schemes employ a fixed order link selection rule,which often creates a bottleneck preventing time-efficient control.Second,the existing brain-induced position controllers are designed to generate a position response like a traditional firstorder system,resulting in a large steady-state error.This paper overcomes the above two limitations by keeping provisions for steady-state visual evoked potential(SSVEP)induced linkselection in an arbitrary order as required for efficient control and generating a second-order response of the position-control system with gradually diminishing overshoots/undershoots to reduce steady-state errors.Other than the above,the third innovation is to utilize motor imagery and P300 signals to design the hybrid brain-computer interfacing system for the said application with gradually diminishing error-margin using speed reversal at the zero-crossings of positional errors.Experiments undertaken reveal that the steady-state error is reduced to 0.2%.The paper also provides a thorough analysis of the stability of the closed-loop system performance using the Root Locus technique. 展开更多
关键词 brain-computer interfacing(BCI) electroencepha-lography(EEG) Jaco robot arm motor imagery P300 steady-state visually evoked potential(SSVEP)
下载PDF
Electric Wheelchair Control System Using Brain-Computer Interface Based on Alpha-Wave Blocking 被引量:2
6
作者 明东 付兰 +8 位作者 陈龙 汤佳贝 綦宏志 赵欣 周鹏 张力新 焦学军 王春慧 万柏坤 《Transactions of Tianjin University》 EI CAS 2014年第5期358-363,共6页
A brain-computer interface(BCI)-based electric wheelchair control system was developed, which enables the users to move the wheelchair forward or backward, and turn left or right without any pre-learning. This control... A brain-computer interface(BCI)-based electric wheelchair control system was developed, which enables the users to move the wheelchair forward or backward, and turn left or right without any pre-learning. This control system makes use of the amplitude enhancement of alpha-wave blocking in electroencephalogram(EEG) when eyes close for more than 1 s to constitute a BCI for the switch control of wheelchair movements. The system was formed by BCI control panel, data acquisition, signal processing unit and interface control circuit. Eight volunteers participated in the wheelchair control experiments according to the preset routes. The experimental results show that the mean success control rate of all the subjects was 81.3%, with the highest reaching 93.7%. When one subject's triggering time was 2.8 s, i.e., the flashing time of each cycle light was 2.8 s, the average information transfer rate was 8.10 bit/min, with the highest reaching 12.54 bit/min. 展开更多
关键词 electric wheelchair alpha-wave blocking brain-computer interface (BCI) success control rate
下载PDF
Application of Brain-Computer-Interface in Awareness Detection Using Machine Learning Methods 被引量:1
7
作者 Kaiqiang Feng Weilong Lin +6 位作者 Feng Wu Chengxin Pang Liang Song Yijia Wu Rong Cao Huiliang Shang Xinhua Zeng 《China Communications》 SCIE CSCD 2022年第6期279-291,共13页
The awareness detection in patients with disorders of consciousness currently relies on behavioral observations and CRS-R tests,however,the misdiagnosis rates have been relatively high.In this study,we applied brain-c... The awareness detection in patients with disorders of consciousness currently relies on behavioral observations and CRS-R tests,however,the misdiagnosis rates have been relatively high.In this study,we applied brain-computer interface(BCI)to awareness detection with a passive auditory stimulation paradigm.12 subjects with normal hearing were invited to collect electroencephalogram(EEG)based on a BCI communication system,in which EEG signals are transmitted wirelessly.After necessary preprocessing,RBF-SVM and EEGNet were used for algorithm realization and analysis.For a single subject,RBF-SVM can distinguish his(her)name stimuli awareness with classification accuracies ranging from 60-95%.EEGNet was used to learn all subjects'data and improved accuracy to 78.04%for characteristics finding and model generalization.Moreover,we completed the supplementary analysis work from the time domain and time-frequency domain.This study applied BCI communication to human awareness detection,proposed a passive auditory paradigm,and proved the effectiveness,which could be an inspiration for brain,mental or physical diseases diagnosis and detection. 展开更多
关键词 brain-computer interface EEG awareness detection machine learning deep learning
下载PDF
Individualization of Data-Segment-Related Parameters for Improvement of EEG Signal Classification in Brain-Computer Interface 被引量:1
8
作者 曹红宝 BESIO Walter G +1 位作者 JONES Steven 周鹏 《Transactions of Tianjin University》 EI CAS 2010年第3期235-238,共4页
In electroencephalogram (EEG) modeling techniques, data segment selection is the first and still an important step. The influence of a set of data-segment-related parameters on feature extraction and classification in... In electroencephalogram (EEG) modeling techniques, data segment selection is the first and still an important step. The influence of a set of data-segment-related parameters on feature extraction and classification in an EEG-based brain-computer interface (BCI) was studied. An auto search algorithm was developed to study four datasegment-related parameters in each trial of 12 subjects’ EEG. The length of data segment (LDS), the start position of data (SPD) segment, AR order, and number of trials (NT) were used to build the model. The study showed that, compared with the classification ratio (CR) without parameter selection, the CR was increased by 20% to 30% with proper selection of these data-segment-related parameters, and the optimum parameter values were subject-dependent. This suggests that the data-segment-related parameters should be individualized when building models for BCI. 展开更多
关键词 data segment parameter selection EEG classification brain-computer interface (BCI)
下载PDF
Common Spatial Pattern Ensemble Classifier and Its Application in Brain-Computer Interface 被引量:5
9
作者 Xu Lei Ping Yang Peng Xu Tie-Jun Liu De-Zhong Yao 《Journal of Electronic Science and Technology of China》 2009年第1期17-21,共5页
Abstract-Common spatial pattern (CSP) algorithm is a successful tool in feature estimate of brain-computer interface (BCI). However, CSP is sensitive to outlier and may result in poor outcomes since it is based on... Abstract-Common spatial pattern (CSP) algorithm is a successful tool in feature estimate of brain-computer interface (BCI). However, CSP is sensitive to outlier and may result in poor outcomes since it is based on pooling the covariance matrices of trials. In this paper, we propose a simple yet effective approach, named common spatial pattern ensemble (CSPE) classifier, to improve CSP performance. Through division of recording channels, multiple CSP filters are constructed. By projection, log-operation, and subtraction on the original signal, an ensemble classifier, majority voting, is achieved and outlier contaminations are alleviated. Experiment results demonstrate that the proposed CSPE classifier is robust to various artifacts and can achieve an average accuracy of 83.02%. 展开更多
关键词 brain-computer interface channel selection classifier ensemble common spatial pattern.
下载PDF
Image Segmentation-P300 Selector: A Brain–Computer Interface System for Target Selection
10
作者 Hang Sun Changsheng Li He Zhang 《Computers, Materials & Continua》 SCIE EI 2024年第5期2505-2522,共18页
Brain–computer interface (BCI) systems, such as the P300 speller, enable patients to express intentions withoutnecessitating extensive training.However, the complexity of operational instructions and the slow pace of... Brain–computer interface (BCI) systems, such as the P300 speller, enable patients to express intentions withoutnecessitating extensive training.However, the complexity of operational instructions and the slow pace of characterspelling pose challenges for some patients. In this paper, an image segmentation P300 selector based on YOLOv7-mask and DeepSORT is proposed. The proposed system utilizes a camera to capture real-world objects forclassification and tracking. By applying predefined stimulation rules and object-specificmasks, the proposed systemtriggers stimuli associated with the objects displayed on the screen, inducing the generation of P300 signals in thepatient’s brain. Its video processing mechanism enables the system to identify the target the patient is focusing oneven if the object is partially obscured, overlapped, moving, or changing in number. The system alters the target’scolor display, thereby conveying the patient’s intentions to caregivers. The data analysis revealed that the selfrecognitionaccuracy of the subjects using this method was between 92% and 100%, and the cross-subject P300recognition precision was 81.9%–92.1%. This means that simple instructions such as “Do not worry, just focuson what you desire” effectively discerned the patient’s intentions using the Image Segmentation-P300 selector. Thisapproach provides cost-effective support and allows patients with communication difficulties to easily express theirneeds. 展开更多
关键词 brain-computer interface deep learning ELECTROENCEPHALOGRAM P300 YOLOv7-mask
下载PDF
Neurological rehabilitation of stroke patients via motor imaginary-based brain-computer interface technology
11
作者 Hongyu Sun Yang Xiang Mingdao Yang 《Neural Regeneration Research》 SCIE CAS CSCD 2011年第28期2198-2202,共5页
The present study utilized motor imaginary-based brain-computer interface technology combined with rehabilitation training in 20 stroke patients. Results from the Berg Balance Scale and the Holden Walking Classificati... The present study utilized motor imaginary-based brain-computer interface technology combined with rehabilitation training in 20 stroke patients. Results from the Berg Balance Scale and the Holden Walking Classification were significantly greater at 4 weeks after treatment (P 〈 0.01), which suggested that motor imaginary-based brain-computer interface technology improved balance and walking in stroke patients. 展开更多
关键词 brain-computer interface motor cortex neuronal plasticity REHABILITATION STROKE neural regeneration
下载PDF
Probabilistic Methods in Multi-Class Brain-Computer Interface 被引量:1
12
作者 Ping Yang Xu Lei Tie-Jun Liu Peng Xu De-Zhong Yao 《Journal of Electronic Science and Technology of China》 2009年第1期12-16,共5页
Abstract-Two probabilistic methods are extended to research multi-class motor imagery of brain-computer interface (BCI): support vector machine (SVM) with posteriori probability (PSVM) and Bayesian linear discr... Abstract-Two probabilistic methods are extended to research multi-class motor imagery of brain-computer interface (BCI): support vector machine (SVM) with posteriori probability (PSVM) and Bayesian linear discriminant analysis with probabilistic output (PBLDA). A comparative evaluation of these two methods is conducted. The results shows that: 1) probabilistie information can improve the performance of BCI for subjects with high kappa coefficient, and 2) PSVM usually results in a stable kappa coefficient whereas PBLDA is more efficient in estimating the model parameters. 展开更多
关键词 Bayesian linear discriminant analysis brain-computer interface kappa coefficient support vector machine.
下载PDF
Transfer Learning Algorithm Design for Feature Transfer Problem in Motor Imagery Brain-computer Interface
13
作者 Yu Zhang Huaqing Li +3 位作者 Heng Dong Zheng Dai Xing Chen Zhuoming Li 《China Communications》 SCIE CSCD 2022年第2期39-46,共8页
The non-stationary of the motor imagery electroencephalography(MI-EEG)signal is one of the main limitations for the development of motor imagery brain-computer interfaces(MI-BCI).The nonstationary of the MI-EEG signal... The non-stationary of the motor imagery electroencephalography(MI-EEG)signal is one of the main limitations for the development of motor imagery brain-computer interfaces(MI-BCI).The nonstationary of the MI-EEG signal and the changes of the experimental environment make the feature distribution of the testing set and training set deviates,which reduces the classification accuracy of MI-BCI.In this paper,we propose a Kullback–Leibler divergence(KL)-based transfer learning algorithm to solve the problem of feature transfer,the proposed algorithm uses KL to measure the similarity between the training set and the testing set,adds support vector machine(SVM)classification probability to classify and weight the covariance,and discards the poorly performing samples.The results show that the proposed algorithm can significantly improve the classification accuracy of the testing set compared with the traditional algorithms,especially for subjects with medium classification accuracy.Moreover,the algorithm based on transfer learning has the potential to improve the consistency of feature distribution that the traditional algorithms do not have,which is significant for the application of MI-BCI. 展开更多
关键词 brain-computer interface motor imagery feature transfer transfer learning domain adaptation
下载PDF
Performance and Implementations of Vibrotactile Brain-Computer Interface with Ipsilateral and Bilateral Stimuli
14
作者 SUN Hongyan JIN Jing +2 位作者 ZHANG Yu WANG Bei WANG Xingyu 《Journal of Donghua University(English Edition)》 EI CAS 2018年第6期439-445,共7页
The tactile P300 brain-computer interface( BCI) is related to the somatosensory perception and response of the human brain,and is different from visual or audio BCIs. Recently,several studies focused on the tactile st... The tactile P300 brain-computer interface( BCI) is related to the somatosensory perception and response of the human brain,and is different from visual or audio BCIs. Recently,several studies focused on the tactile stimuli delivered to different parts of the human body. Most of these stimuli were symmetrically bilateral.Only a fewstudies explored the influence of tactile stimuli laterality.In the current study,we extensively tested the performance of a vibrotactile BCI system using ipsilateral stimuli and bilateral stimuli.Two vibrotactile P300-based paradigms were tested. The target stimuli were located on the left and right forearms for the left forearm and right forearm( LFRF) paradigm,and on the left forearm and calf for the left forearm and left calf( LFLC)paradigm. Ten healthy subjects participated in this study. Our experiments and analysis showed that the bilateral paradigm( LFRF) elicited larger P300 amplitude and achieved significantly higher classification accuracy than the ipsilateral paradigm( LFLC). However, both paradigms achieved classification accuracies higher than 70% after the completion of several trials on average,which was usually regarded as the minimum accuracy level required for BCI system to be deemed useful. 展开更多
关键词 brain-computer interface (BCI) tactile P300 IPSILATERAL stimuli BILATERAL stimuli paradigm LEFT FOREARM right FOREARM LEFT CALF
下载PDF
Possibility to Realize the Brain-Computer Interface from the Quantum Brain Model Based on Superluminal Particles
15
作者 Takaaki Musha Toshiki Sugiyama 《Journal of Quantum Information Science》 2011年第3期111-115,共5页
R. Penrose and S. Hameroff have proposed an idea that the brain can attain high efficient quantum computation by functioning of microtubular structure of neurons in the cytoskelton of biological cells, including neuro... R. Penrose and S. Hameroff have proposed an idea that the brain can attain high efficient quantum computation by functioning of microtubular structure of neurons in the cytoskelton of biological cells, including neurons of the brain. But Tegmark estimated the duration of coherence of a quantum state in a warm wet brain to be on the order of 10>–13 </supseconds, which is far smaller than the one tenth of a second associated with consciousness. Contrary to his calculation, it can be shown that the microtubule in a biological brain can perform computation satisfying the time scale required for quantum computation to achieve large quantum bits calculation compared with the conventional silicon processors even at the room temperature from the assumption that tunneling photons are superluminal particles called tachyons. According to the non-local property of tachyons, it is considered that the tachyon field created inside the brain has the capability to exert an influence around the space outside the brain and it functions as a macroscopic quantum dynamical system to meditate the long-range physical correlations with the surrounding world. From standpoint of the brain model based on superluminal tunneling photons, the authors theoretically searched for the possibility to realize the brain-computer interface that allows paralyzed patient to operate computers by their thoughts and they obtained the positive result for its realization from the experiments conducted by using the prototype of a brain-computer interface system. 展开更多
关键词 brain-computer interface EVANESCENT Photon TACHYON QUANTUM Computation DECOHERENCE
下载PDF
Real-Time Detection of Human Drowsiness via a Portable Brain-Computer Interface
16
作者 Julia Shen Baiyan Li Xuefei Shi 《Open Journal of Applied Sciences》 2017年第3期98-113,共16页
In this paper, we proposed a new concept: depth of drowsiness, which can more precisely describe the drowsiness than existing binary description. A set of effective markers for drowsiness: normalized band norm was suc... In this paper, we proposed a new concept: depth of drowsiness, which can more precisely describe the drowsiness than existing binary description. A set of effective markers for drowsiness: normalized band norm was successfully developed. These markers are invariant from voltage amplitude of brain waves, eliminating the need for calibrating the voltage output of the brain-computer interface devices. A new polling algorithm was designed and implemented for computing the depth of drowsiness. The time cost of data acquisition and processing for each estimate is about one second, which is well suited for real-time applications. Test results with a portable brain-computer interface device show that the depth of drowsiness computed by the method in this paper is generally invariant from ages of test subjects and sensor channels (P3 and C4). The comparison between experiment and computing results indicate that the new method is noticeably better than one of the recent methods in terms of accuracy for predicting the drowsiness. 展开更多
关键词 brain-computer interface BRAIN Wave DROWSINESS Real-Time FOURIER TRANSFORM POLLING Algorithm
下载PDF
On Similarities and Differences of Invasive and Non-Invasive Electrical Brain Signals in Brain-Computer Interfacing
17
作者 David Steyrl Reinmar J. Kobler Gernot R. Müller-Putz 《Journal of Biomedical Science and Engineering》 2016年第8期393-398,共7页
We perceive that some Brain-Computer Interface (BCI) researchers believe in totally different origins of invasive and non-invasive electrical BCI signals. Based on available literature we argue, however, that although... We perceive that some Brain-Computer Interface (BCI) researchers believe in totally different origins of invasive and non-invasive electrical BCI signals. Based on available literature we argue, however, that although invasive and non-invasive BCI signals are different, the underlying origin of electrical BCIs signals is the same. 展开更多
关键词 brain-computer interfaces Electrical Brain Signals Invasive Signals Non-Invasive Signals COMPARISON
下载PDF
Brain-Computer Interface Design Using Signal Powers Extracted During Motor Imagery Tasks
18
作者 HE Ke-ren WANG Xin-guang +1 位作者 ZOU Ling MA Zheng-hua 《Chinese Journal of Biomedical Engineering(English Edition)》 2011年第4期139-149,共11页
Accurate classification of EEG left and right hand motor imagery is an important issue in brain-computer interface. Firstly, discrete wavelet transform method was used to decompose the average power of C3 electrode an... Accurate classification of EEG left and right hand motor imagery is an important issue in brain-computer interface. Firstly, discrete wavelet transform method was used to decompose the average power of C3 electrode and C4 electrode in left-right hands imagery movement during some periods of time. The reconstructed signal of approximation coefficient A6 on the 6al level was selected to build up a feature signal. Secondly, the performances by Fisher Linear Discriminant Analysis with two different threshold calculation ways and Support Vector Machine methods were compared. The final classification results showed that false classification rate by Support Vector Machine was lower and gained an ideal classification results. 展开更多
关键词 brain-computer interface motor imagery feature extraction pattern classification
下载PDF
Design of an EEG Preamplifier for Brain-Computer Interface
19
作者 Xian-Jie Pu Tie-Jun Liu De-Zhong Yao 《Journal of Electronic Science and Technology of China》 2009年第1期56-60,共5页
As a non-invasive neurophysiologieal index for brain-computer interface (BCI), electroencephalogram (EEG) attracts much attention at present. In order to have a portable BCI, a simple and efficient pre-amplifier i... As a non-invasive neurophysiologieal index for brain-computer interface (BCI), electroencephalogram (EEG) attracts much attention at present. In order to have a portable BCI, a simple and efficient pre-amplifier is crucial in practice. In this work, a preamplifier based on the characteristics of EEG signals is designed, which consists of a highly symmetrical input stage, low-pass filter, 50 Hz notch filter and a post amplifier. A prototype of this EEG module is fabricated and EEG data are obtained through an actual experiment. The results demonstrate that the EEG preamplifier will be a promising unit for BCI in the future. 展开更多
关键词 brain-computer interface(BCI) electroencephalogram(EEG) FILTERING interference pre amplifier.
下载PDF
On the development of optical peripheral nerve interfaces 被引量:1
20
作者 Hans E.Anderson Richard F.ff.Weir 《Neural Regeneration Research》 SCIE CAS CSCD 2019年第3期425-436,共12页
Limb loss and spinal cord injury are two debilitating conditions that continue to grow in prevalence. Prosthetic limbs and limb reanimation present two ways of providing affected individuals with means to interact in ... Limb loss and spinal cord injury are two debilitating conditions that continue to grow in prevalence. Prosthetic limbs and limb reanimation present two ways of providing affected individuals with means to interact in the world. These techniques are both dependent on a robust interface with the peripheral nerve. Current methods for interfacing with the peripheral nerve tend to suffer from low specificity, high latency and insufficient robustness for a chronic implant. An optical peripheral nerve interface may solve some of these problems by decreasing invasiveness and providing single axon specificity. In order to implement such an interface three elements are required:(1) a transducer capable of translating light into a neural stimulus or translating neural activity into changes in fluorescence,(2) a means for delivering said transducer and(3) a microscope for providing the stimulus light and detecting the fluorescence change. There are continued improvements in both genetically encoded calcium and voltage indicators as well as new optogenetic actuators for stimulation. Similarly, improvements in specificity of viral vectors continue to improve expression in the axons of the peripheral nerve. Our work has recently shown that it is possible to virally transduce axons of the peripheral nerve for recording from small fibers. The improvements of these components make an optical peripheral nerve interface a rapidly approaching alternative to current methods. 展开更多
关键词 PERIPHERAL NERVE interfaces optogenetics OPTICAL neural interface OPTICAL PERIPHERAL NERVE interface GCaMP ArcLight adenoassociated VIRAL vector lentiviral VECTORS VIRAL VECTORS implantable microscopy
下载PDF
上一页 1 2 15 下一页 到第
使用帮助 返回顶部