期刊文献+
共找到20篇文章
< 1 >
每页显示 20 50 100
Rhegmatogenous retinal detachment in highly myopic eyes with implantable collamer lens
1
作者 Jun Li Chong-Lin Chen +2 位作者 Jia-Qing Li Xiao-Ling Liang Chun Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期392-396,共5页
AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who receiv... AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who received treatment for nontraumatic RRD after ICL implantation surgery at the Retinal Department of Zhongshan Ophthalmic Center from Jan 2018 to Dec 2022 were reviewed.Comprehensive ophthalmologic examinations including visual acuity measurement and digital fundus photography were performed in each patient.RESULTS:A total of nine RRD eyes from nine patients who received V4c-ICL implantation were included.The mean time from ICL implantation surgery to the diagnosis of RRD was 32.44±22.56mo(range,1-60mo).At the initial visit for RRD,giant retinal tear(GRT),horseshoe tear,simple round hole,and horseshoe tear combined with round hole were detected in 3,3,2,and 1 eye(s),respectively,with maculaoff in eyes.Eight patients received surgical treatment,and one patient was treated by retinal laser photocoagulation alone.The ICL was preserved in 7 eyes.At the last followup,the mean best corrected visual acuity(BCVA)improved significantly from 1.76±1.06 logMAR at presentation to 0.81±1.01 logMAR(P=0.035),and no case of recurrent retinal detachment was found.CONCLUSION:The morphological presentation of retinal breaks is diverse in this study.The ICL can be preserved in most cases during the course of retinal detachment repair surgery in our data,companied with acceptable visual and anatomical outcomes. 展开更多
关键词 high myopia implantable collamer lens rhegmatogenous retinal detachment
下载PDF
Postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens implantation versus small incision lenticule extraction in myopic eyes:a Meta-analysis 被引量:2
2
作者 Hong-Yu Li Zi Ye Zhao-Hui Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第3期442-452,共11页
AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,W... AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,Web of Science,Cochrane Library and several Chinese databases were searched at May 2021 to select relevant studies in comparison of clinical outcomes between ICL implantation and SMILE for myopia.The primary outcomes were efficacy,safety,and predictability.And the secondary outcomes were postoperative higher-order ocular aberrations(HOAs),modulation transfer function cutoff frequency(MTF),objective scatter index(OSI),contrast sensitivity and a quality of vision(Qo V)questionnaire.RESULTS:A total of 1036 eyes from 10 studies,of which 503 eyes underwent ICL implantation and 533 eyes underwent SMILE,were enrolled in this Meta-analysis.Pooled results revealed that ICL group had a better safety index and post-corrected distance visual acuity(CDVA)(P=0.007,<0.00001,respectively),and a lower percentage of eyes with a postoperative CDVA lost 1 line(P=0.007)than the SMILE group.No significant differences were found in comparison of the other primary outcomes.In the longterm follow-up(>6mo),ICL group had a lower total HOA,coma,and spherical aberration than SMILE group(P=0.003,<0.00001,0.04).Yet higher trefoil was found in ICL group at 6mo after surgery(P=0.003).Additionally,ICL group also had a higher MTF value(P=0.02),and a higher contrast sensitivity score for spatial frequencies of 1.5,6,and 12 cpds(P=0.02,0.005,0.02,respectively).And it also had a lower score of bothersome in Qo V questionnaire than SMILE group(P=0.003).CONCLUSION:ICL implantation and SMILE have similar and comparable outcomes in term of the efficacy and predictability for correcting high myopia.However,ICL group is relatively safer and also has better visual quality in comparison of SMILE group. 展开更多
关键词 implantable collamer lens small incision lenticule extraction MYOPIA refractive surgery META-ANALYSIS
下载PDF
Long-term observation on safety and visual quality of implantable collamer lens V4c implantation for myopia correction:a 5-year follow-up 被引量:2
3
作者 Xiao Chen Li Li +4 位作者 Jing Rao Yue-Xi Chen Yang Gao Rui-Xue Huang Qi-Zhi Zhou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第7期1123-1129,共7页
AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted... AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted on 58 patients(114 eyes)who were followed up for at least 5y after ICL V4c implantation.The observation was done before and on 1d,1mo,1 and 5y or more after the surgical procedure.The visual acuity,subjective refraction,intraocular pressure,vault,axial length,central hole position,pupil diameter,visual quality,and adverse events were analyzed.The visual quality includes aberration,the modulation transfer function cutoff frequency(MTF cutoff),objective scattering index(OSI),Stroller's ratio(SR),and visual quality questionnaire.RESULTS:The average follow-up period was 69.25±3.80mo(range 60–82mo)and the preoperative spherical equivalent(SE)was-8.66±1.97 D.At 5y after operation,the safety index was 1.01±0.02 and the efficacy index was 0.99±0.42 and SE was-0.65±0.63 D.The 59.6%of the eyes achieved an uncorrected distance visual acuity of 20/20,76.3%of the eyes had SE within±1.0 D at the last visit.The axial length increased by 0.29±0.71 mm 5y after the surgery(t=-3.843,P<0.001).The mean vault at the last follow-up was 510.59±245.61μm.The central hole was on the temporal side in 80 eyes(84.2%).The visual quality questionnaire showed that 98.2%patients were satisfied with the surgical procedure.Adverse events occurred in 4 eyes(3.5%),including the posttraumatic toric ICL rotation(2 eyes),iris incarceration(1 eye),and posttraumatic ICL displacement(1 eye)at the last follow-up.CONCLUSION:Long-term ICL V4c implantation is safe,effective,and stable for correcting moderate and to high myopia,and the visual quality with patients is excellent and satisfactory,but the progression of axial length still needs attention after surgery. 展开更多
关键词 implantable collamer lens with central hole myopia correction refractive surgery visual quality
下载PDF
Vault predicting after implantable collamer lens implantation using random forest network based on different features in ultrasound biomicroscopy images
4
作者 Bin Fang Qiu-Jian Zhu +1 位作者 Hui Yang Li-Cheng Fan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第10期1561-1567,共7页
AIM:To analyze ultrasound biomicroscopy(UBM)images using random forest network to find new features to make predictions about vault after implantable collamer lens(ICL)implantation.METHODS:A total of 450 UBM images we... AIM:To analyze ultrasound biomicroscopy(UBM)images using random forest network to find new features to make predictions about vault after implantable collamer lens(ICL)implantation.METHODS:A total of 450 UBM images were collected from the Lixiang Eye Hospital to provide the patient’s preoperative parameters as well as the vault of the ICL after implantation.The vault was set as the prediction target,and the input elements were mainly ciliary sulcus shape parameters,which included 6 angular parameters,2 area parameters,and 2 parameters,distance between ciliary sulci,and anterior chamber height.A random forest regression model was applied to predict the vault,with the number of base estimators(n_estimators)of 2000,the maximum tree depth(max_depth)of 17,the number of tree features(max_features)of Auto,and the random state(random_state)of 40.0.RESULTS:Among the parameters selected in this study,the distance between ciliary sulci had a greater importance proportion,reaching 52%before parameter optimization is performed,and other features had less influence,with an importance proportion of about 5%.The importance of the distance between the ciliary sulci increased to 53% after parameter optimization,and the importance of angle 3 and area 1 increased to 5% and 8%respectively,while the importance of the other parameters remained unchanged,and the distance between the ciliary sulci was considered the most important feature.Other features,although they accounted for a relatively small proportion,also had an impact on the vault prediction.After parameter optimization,the best prediction results were obtained,with a predicted mean value of 763.688μm and an actual mean value of 776.9304μm.The R²was 0.4456 and the root mean square error was 201.5166.CONCLUSION:A study based on UBM images using random forest network can be performed for prediction of the vault after ICL implantation and can provide some reference for ICL size selection. 展开更多
关键词 random forest network ultrasound biomicroscopy images vault prediction implantable collamer lens
下载PDF
Implantable collamer lens for residual refractive error after corneal refractive surgery 被引量:6
5
作者 Xun Chen Xiao-Ying Wang +2 位作者 Xi Zhang Zhi Chen Xing-Tao Zhou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第10期1421-1426,共6页
AIM:To assess the safety,efficacy,predictability and stability of implantable collamer lens(ICL) for residual refractive error after corneal refractive surgery.METHODS: This study evaluated 19 eyes of 12 patients ... AIM:To assess the safety,efficacy,predictability and stability of implantable collamer lens(ICL) for residual refractive error after corneal refractive surgery.METHODS: This study evaluated 19 eyes of 12 patients who underwent ICL implantation after corneal refractive surgeries.They were followed up for 1y to 5y of uncorrected distance visual acuity(UDVA),corrected distance visual acuity(CDVA),manifest refractive error,flat and steep K value,axial length,intraocular pressure,corneal endothelial cell density,adverse events after ICL surgery.RESULTS: The mean follow-up period was 39.05 ±19.22 mo(range,1-5y).Spherical equivalent refractive error changed from-7.45±3.02 D preoperatively to-0.85±1.10 D 1wk to 1mo after ICL implantation,with the safety and efficacy indices being 1.12 and 1.15,respectively.A total of 52.63% of eyes were within ±0.5 D of the predicted spherical equivalents,73.68% were within ±1.0 D.A trend of mild regression towards myopia with axial elongation after 5y was observed.One eye with mild anterior capsule opacity and retinal detachment 1y after surgery were observed.CONCLUSION: ICL implantation is safe and effective for the correction of residual refractive error after corneal refractive surgeries,especially in moderate to high residual myopia. 展开更多
关键词 implantable collamer lens radial keratotomy photorefractive keratectomy laser-assisted in situ keratomileusis laser-assisted subepithelial keratomileusis
下载PDF
Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens 被引量:7
6
作者 Min Ji Park Hye Min Jeon Kyoung Heon Lee Sang Youp Han 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第4期619-623,共5页
AIM:To evaluate the clinical outcomes of V4 c implantable collamer lens(Hole ICL) implantation with regard to the optical quality assessed according to different degrees of decentering.METHODS:This included 49 eye... AIM:To evaluate the clinical outcomes of V4 c implantable collamer lens(Hole ICL) implantation with regard to the optical quality assessed according to different degrees of decentering.METHODS:This included 49 eyes that received conventional ICL and 94 eyes that received Hole ICL.The eyes that received Hole ICL were divided into three groups according to the degree of decentering:group 1,central hole within 1 hole diameter(HD) from the pupil center;group 2,central hole within 1 HD to 2 HD;and group 3,central hole within 2 HD to 3 HD.Visual acuity(VA),intraocular pressure(IOP),and spherical equivalent(SE) values were assessed at 1wk,1 and 3mo after surgery.The ocular modulation transfer function,Strehl ratio,objective scattering index,and higher order aberrations(HOAs) were measured for 4-mm pupils at 3mo after surgery.RESULTS:There were no significant differences in VA,IOP,and SE among the conventional and Hole ICL groups.With regard to HOAs,values for coma and spherical aberrations showed no differences.The total HOA and trefoil values were significantly higher in group 2 than in group 1(P=0.02,0.03,respectively).There were no significant differences among groups with regard to other optical quality parameter at 3mo after surgery.CONCLUSION:Our results suggest that Hole ICL implantation provides satisfactory visual quality that is equivalent to that provided by conventional ICL,regardless of the presence of central hole and degree of decentering. 展开更多
关键词 implantable collamer lens optical quality phakic IOL refractive surgery
下载PDF
A case of hypermature cataract formation following implantation of an implantable collamer lens with an Aquaport 被引量:3
7
作者 Kyu-Yeon Hwang Sung A.Lim So-Hyang Chung 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第6期1014-1015,共2页
To improve humor circulation the latest V4c Visian implantable collamer lens (ICL) was designed with a0.36-ram Aquapon. This design also eliminates the need to perform peripheral iridectomy before ICL implantation. ... To improve humor circulation the latest V4c Visian implantable collamer lens (ICL) was designed with a0.36-ram Aquapon. This design also eliminates the need to perform peripheral iridectomy before ICL implantation. Several authors reported rates of secondary surgical intervention related to insufficient vault in the presence or absence of cataract formation and excessive vault in the presence or absence of elevated intraocular pressure (IOP) after ICL insertion. Here, we report a case of rapid progression of a cataract to a hypermature state after implantation of an ICL with an Aquaport. 展开更多
关键词 ICL A case of hypermature cataract formation following implantation of an implantable collamer lens with an Aquaport CASE
下载PDF
Comparison of choroidal thickness in high myopic eyes after FS-LASIK versus implantable collamer lens implantation with swept-source optical coherence tomography 被引量:2
8
作者 Jing Zhang Fang-Lin He +1 位作者 Yan Liu Xian-Qun Fan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第5期773-781,共9页
AIM:To investigate the changes in choroidal thickness(CT)in high myopic eyes after femtosecond laser-assisted in situ keratomileusis(FS-LASIK)surgery or central hole implantable collamer lens(ICL V4c)implantation usin... AIM:To investigate the changes in choroidal thickness(CT)in high myopic eyes after femtosecond laser-assisted in situ keratomileusis(FS-LASIK)surgery or central hole implantable collamer lens(ICL V4c)implantation using swept-source optical coherence tomography(SS-OCT).METHODS:We examined the right eyes of 116 patients with high myopia who were candidates for FS-LASIK surgery and ICL implantation.Sixty eyes underwent ICL V4c implantation and 56 eyes were subjected to FS-LASIK surgery.The CT was measured with SS-OCT.All data were recorded preoperatively and 2 h,1 wk,1 and 3 mo postoperatively.Other demographic information was collected,including age,sex,uncorrected visual acuity(UCVA),best corrected visual acuity(BCVA),spherical equivalent(SE),intraocular pressure(IOP)and axial length(AL).RESULTS:The UCVA improved in both groups and showed no significant differences between groups.There also were no significant differences between the two groups in postoperative BCVA and SE(P=0.581 and 0.203,respectively).The foveal CTs,inner nasal and outer nasal CTs were significantly thicker at 2 h postoperatively in both groups(P<0.05)but returned to baseline levels in 1 wk;after 1 mo,no significant differences were found relative to the preoperative values.At 3 mo in each group,nine regions showed variations in the CT as compared with preoperative thickening,but only the foveal and nasal area CTs preoperative differences were statistically significant(P<0.05).In addition,there was no significant difference in 9 regions of CT between the two groups at all follow-up times(P>0.05).CONCLUSION:The CTs after ICL implantation and FSLASIK surgery are significantly thicker than those before operation,especially in the foveal and nasal areas,but there is no significant difference between the two methods. 展开更多
关键词 choroidal thickness high myopia laser in situ keratomileusis implantable collamer lens implantation swept-source optical coherence tomography
下载PDF
Comparison of optical quality after implantable collamer lens implantation and wavefront-guided laser in situ keratomileusis 被引量:11
9
作者 Hong-Ting Liu Zhou Zhou +8 位作者 Wu-Qiang Luo Wen-Jing He Owhofasa Agbedia Jiang-Xia Wang Jian-Zhong Huang Xin Gao Min Kong Min Li Li Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第4期656-661,共6页
AIM: To compare the optical quality after implantation of implantable collamer lens(ICL) and wavefront-guided laser in situ keratomileusis(WG-LASIK).METHODS: The study included 40 eyes of 22 patients with myopia... AIM: To compare the optical quality after implantation of implantable collamer lens(ICL) and wavefront-guided laser in situ keratomileusis(WG-LASIK).METHODS: The study included 40 eyes of 22 patients with myopia who accepted ICL implantation and 40 eyes of 20 patients with myopia who received WG-LASIK. Before surgery and three months after surgery, the objective scattering index(OSI), the values of modulation transfer function(MTF) cutoff frequency, Strehl ratio, and the Optical Quality Analysis System(OQAS) values(OVs) were accessed. The higher order aberrations(HOAs) data including coma, trefoil, spherical, 2^(nd) astigmatism and tetrafoil were also obtained. For patients with pupil size 〈6 mm, HOAs data were analyzed for 4 mm-pupil diameter. For patients with pupil size ≥6 mm, HOAs data were calculated for 6 mm-pupil diameter. Visual acuity, refraction, pupil size and intraocular pressures were also recorded.RESULTS: In both ICL and WG-LASIK group, significant improvements in visual acuities were found postoperatively, with a significant reduction in spherical equivalent(P〈 0.001). After the ICL implantation, the OSI decreasedslightly from 2.34±1.92 to 2.24±1.18 with no statistical significance(P=0.62). While in WG-LASIK group, the OSI significantly increased from 0.68±0.43 preoperatively to 0.91±0.53 postoperatively(Wilcoxon signed ranks test, P=0.000). None of the mean MTF cutoff frequency, Strehl ratio, OVs showed statistically significant changes in both ICL and WG-LASIK groups. In the ICL group, there were no statistical differences in the total HOAs for either 4 mmpupil or 6 mm-pupil. In the WG-LASIK group, the HOA parameters increased significantly at 4 mm-pupil. The total ocular HOAs, coma, spherical and 2^(nd) astigmatism were 0.12±0.06, 0.06±0.03, 0.00±0.03, 0.02±0.01, respectively. After the operation, these values were increased into 0.16±0.07, 0.08±0.05,-0.04±0.04, 0.03±0.01 respectively(Wilcoxon signed ranks test, all P〈0.05). At 6 mm-pupil, the induction of total HOAs was not statistically significant in the WG-LASIK group. CONCLUSION: ICL implantation has a less disturbance to optical quality than WG-LASIK. The OQAS is a valuable complementary measurement to the wavefront aberrometers in evaluating the optical quality. 展开更多
关键词 optical quality implantable collamer lens wavefront-guided laser in situ keratomileusis
下载PDF
Optical and visual quality comparison of implantable collamer lens and femtosecond laser assisted laser in situ keratomileusis for high myopia correction 被引量:2
10
作者 Zheng Jiang Hua Wang +1 位作者 Dong-Qiang Luo Jiao Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第5期737-743,共7页
AIM:To compare clinical outcomes and refractive stability of implantable collamer lens(ICL)implantation and femtosecond laser assisted laser in situ keratomileusis(FSLASIK)for high myopia correction.METHODS:The Optica... AIM:To compare clinical outcomes and refractive stability of implantable collamer lens(ICL)implantation and femtosecond laser assisted laser in situ keratomileusis(FSLASIK)for high myopia correction.METHODS:The Optical Quality Analysis System(OQAS)was used to evaluate clinical outcomes objectively after operation for high myopia correction.We compared the two procedures in terms of 1-year changes in uncorrected distance visual acuity(UDVA),corrected distance visual acuity(CDVA),safety index,efficacy index,spherical equivalent,modulation transfer function(MTF)cutoff frequency,strehl ratio(SR)and objective scatter index(OSI).RESULTS:At 1 y postoperatively,the safety indices were 1.33±0.27 in ICL group,and 1.17±0.24 in FS-LASIK group.39.58%in the ICL group and 27.59%in the FS-LASIK group gained CDVA in 2 lines or better than that in preoperative CDVA.The efficacy indices were 1.28±0.22 in ICL group,and 1.13±0.26 in FS-LASIK group.The changes of spherical equivalent from 1 wk to 1 y postoperatively was-0.12±0.37 D in ICL group,and-0.79±0.58 D in FS-LASIK group(P<0.05).Spherical equivalent within±0.50 D was achieved in 97.92%in ICL group and 68.97%in FS-LASIK group.MTF cutoff frequency were higher with ICL as compared to FSLASIK(P<0.05)at each postoperative follow-up stage;for postoperative 1 mo later,SR was statistically significant difference between two groups(P<0.05);with no statistically significant difference in OSI between two groups(P>0.05)in postoperative 3 mo later.CONCLUSION:ICL implantation and FS-LASIK procedures both provide good safety and predictability in high myopia correction.ICL implantation provides better clinical outcomes and refractive stability than FS-LASIK. 展开更多
关键词 implantable collamer lens implantation femtosecond laser assisted laser in situ keratomileusis refractive stability high myopia
下载PDF
Clinical observations of iridociliary cysts and their changes after implantable collamer lens implantation in myopic patients 被引量:2
11
作者 Qian Chen Meng-Ying Qi +1 位作者 Xiao-Hua Lei Qing-Yan Zeng 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第6期965-969,共5页
AIM:To observe the characteristics of iridociliary cysts in myopic patients and evaluate the influences on the position and safety of implantable collamer lens(ICL)after surgery.METHODS:Totally 270 eyes of 135 patient... AIM:To observe the characteristics of iridociliary cysts in myopic patients and evaluate the influences on the position and safety of implantable collamer lens(ICL)after surgery.METHODS:Totally 270 eyes of 135 patients who underwent ICL surgery for the corrections of myopia were included in this study.Preoperative and postoperative morphology of iridociliary cysts were observed in ultrasonic biomicroscopy(UBM)image.RESULTS:A total of 138 iridociliary cysts were found in 88 eyes of 50 patients among 270 eyes of 135 patients before surgery(37%).Twenty-five patients had cysts in one eye(50%)and 25 had cysts in both eyes(50%).The prevalence of iridociliary cysts was negatively correlated with age,but no gender difference(P>0.05).The incidence of iridociliary cysts was much less in eyes with myopia greater than-9.00 D(P<0.05).The diameter of the largest cyst was 1.96 mm and the smallest cyst was 0.24 mm,with a majority within the range of 0.5 to 1.0 mm.Most of the cysts were located in the inferior temporal quadrant.One year after ICL implantation,51 iridociliary cysts(37%)remained unchanged,47 cysts(34%)decreased in size,and 40 cysts(29%)disappeared.Most of cysts that changed after surgery were smaller than 1.0 mm(P<0.05)and located in the nasal and temporal sides around the haptics of implantable lens.All the ICL were in their original position.CONCLUSION:Iridociliary cysts are commonly seen in myopic eyes.The cysts have no impact on the safety of ICL surgery.Some cysts may decrease in size or disappear after ICL implantation. 展开更多
关键词 iridociliary cysts implantable collamer lens myopic
下载PDF
Full-vision maintenance in extra-high myopia from implantable collamer lens to trifocal intraocular lens implantation 被引量:1
12
作者 Shu-Yang Chen Chen Xie +1 位作者 Yang Wang Ye Shen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第7期1239-1242,共4页
Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patien... Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patient with extrahigh myopia from implantable collamer lens (ICL) to trifocal intraocular lens (IOL) implantation. 展开更多
关键词 ICL IOL Full-vision maintenance in extra-high myopia from implantable collamer lens to trifocal intraocular lens implantation
下载PDF
Indications for exchange or explantation of phakic implantable collamer lens with central port in patients with and without keratoconus
13
作者 Albanderi Alhamzah Saad S.Alharbi +2 位作者 Fahad Alfardan Tariq Aldebasi Tariq Almudhaiyan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第11期1714-1720,共7页
AIM:To evaluate the causes of phakic implantable collamer lens(ICL)exchange/explantation in patients with and without keratoconus(KC)at two tertiary hospitals in Riyadh,Saudi Arabia.METHODS:A retrospective chart revie... AIM:To evaluate the causes of phakic implantable collamer lens(ICL)exchange/explantation in patients with and without keratoconus(KC)at two tertiary hospitals in Riyadh,Saudi Arabia.METHODS:A retrospective chart review of all patients who underwent ICL(model V4 c with central port)exchange/explantation was performed using the electronic medical record systems.All available preoperative and postoperative data were documented for each patient.RESULTS:Over 7 y,2283 ICL implantation procedures were performed;46 implants(2%)required exchange(21 implants)/explantation(25 implants),of which 14 cases(30.4%)were patients with KC.Indications for ICL exchange/explantation in non-KC group were vault measurement,cataract formation,increased intraocular pressure,inaccurate refraction,and patient dissatisfaction in 22(68.75%),4(12.5%),3(9.37%),2(6.25%),and 1(3.12%)case,respectively.The most common indication for ICL exchange/explantation in the KC group was inaccurate vault sizing in 11 patients(78.57%),inaccurate refraction in 2 patients(14.28%),and patient dissatisfaction postoperatively in 1(7.14%)case.CONCLUSION:ICL implantation results in predictable refractive outcomes over the long term with exchange/explantation rates comparable to previous literature.Improper vault size is the most common cause of ICL exchange/explantation among patients with or without KC. 展开更多
关键词 EXPLANTATION EXCHANGE implantable collamer lens vault
下载PDF
The effects of implantable collamer lens implantation on higher order aberrations
14
作者 Belma Kayhan Efekan Coskunseven +1 位作者 Onurcan Sahin Ioannis Pallikaris 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第12期1848-1852,共5页
AIM: To evaluate the changes in higher order aberrations(HOAs) after implantable collamer lens(ICL;Staar Surgical, Nidau, Switzerland) implantation. METHODS: Totally 30 eyes of 18 patients with myopia were included in... AIM: To evaluate the changes in higher order aberrations(HOAs) after implantable collamer lens(ICL;Staar Surgical, Nidau, Switzerland) implantation. METHODS: Totally 30 eyes of 18 patients with myopia were included in this study with an average age of 25.77y(min: 21, max: 40). Refraction, uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), HOAs(entire, corneal and internal) were evaluated preoperatively and three months postoperatively. Ocular aberrations were measured by using iT race(Tracey Technology, Houston, Texas, USA). SPSS(IBM Corp. Released 2013. IBM SPSS Statistics for Windows, Version 22.0. Armonk, NY: IBM Corp) was used for the statistical analysis and the interpretation of the data. P values of less than 0.05 were considered statistically significant. RESULTS: The preoperative mean spherical power was -9.01 D(min:-5.00, max:-13.00) and the mean cylindrical error was -2.40 D(min:-0.50, max:-4.75). The postoperative mean residual spherical power was -0.73 D(min:-0.20, max:-1.75) and the mean cylindrical error was -0.89 D(min:-0.18, max:-2.09). Analyses were made on root mean square(RMS) values of total HOAs(tH OAs), spherical aberration, coma and trefoil as entire, corneal and internal components. The differences in entire t HOAs and in internal t HOAs were significant. There was no significant change found in spherical aberrations. The differences in entire coma and in internal coma were significant. There was no significant change found in corneal coma. With respect to trefoil, the only significant difference was in internal trefoil. CONCLUSION: The ICL implantation corrects the refractive error successfully and changes entire and internal HOAs of the eye. 展开更多
关键词 implantable collamer lens MYOPIA ABERRATIONS
下载PDF
In vivo optical quality of posterior-chamber phakic implantable collamer lenses with a central port
15
作者 Robert Montés-Micó Francisco Pastor-Pascual +2 位作者 Enrique Artiaga-Elordi Ramón Ruiz-Mesa Pedro Tañá-Rivero 《Eye and Vision》 SCIE CSCD 2023年第5期24-31,共8页
Background: The aim of this review is to summarize the optical quality results in patients following theimplantation of the V4c implantable collamer lens with a central port (ICL, STAAR Surgical Inc.).Main text: A lit... Background: The aim of this review is to summarize the optical quality results in patients following theimplantation of the V4c implantable collamer lens with a central port (ICL, STAAR Surgical Inc.).Main text: A literature search in several databases was carried out to identify those publications, both prospective,retrospective and/or comparative with other refractive surgery procedures, reporting optical outcomes of patientswho were implanted with the V4c ICL model. A total of 17 clinical studies published between 2012 and 2021 wereincluded in this review. A detailed analysis of the available data was performed including number of eyes, follow-upand preoperative spherical equivalent. Specifically, the review focused on several optical parameters includinghigher-order aberrations (HOAs), modulation transfer function (MTF) cut-off frequency and Strehl ratio. This reviewencompassed a total of 817 eyes measured using different optical devices based on Hartmann-Shack, retinal imagequality measurement and ray-tracing technologies at different follow-ups.Conclusions: The outcomes found in this review lead us to conclude that the ICL V4c model provides good opticalquality, by means of different metrics, when implanted. 展开更多
关键词 implantable collamer lens PHAKIC Optical quality Higher order aberrations Modulation transfer function
原文传递
Biometric and ICL-related risk factors associated to sub-optimal vaults in eyes implanted with implantable collamer lenses
16
作者 Santiago Cerpa Manito Angel Sánchez Trancón +2 位作者 Oscar Torrado Sierra António Manuel Baptista Pedro Miguel Serra 《Eye and Vision》 SCIE CSCD 2023年第5期1-10,共10页
Background To identify biometric and implantable collamer lens(ICL)-related risk factors associated with sub-optimal postoperative vault in eyes implanted with phakic ICL.Methods This study reports a retrospective cas... Background To identify biometric and implantable collamer lens(ICL)-related risk factors associated with sub-optimal postoperative vault in eyes implanted with phakic ICL.Methods This study reports a retrospective case series of the first operated eye in 360 patients implanted with myopic spherical or toric ICL.Preoperatively,white-to-white(WTW),central keratometry(Kc)and central corneal thickness(CCT)were measured using the Pentacam.Anterior-segment optical coherence tomography(AS-OCT,Visante)was applied preoperatively for measuring the horizontal anterior-chamber angle-to-angle distance(ATA),internal anterior chamber depth(ACD),crystalline lens rise(CLR),anterior-chamber angle(ACA)and postoperatively the vault.Eyes were divided into three vault groups:low(LVG:≤250μm),optimal(OVG:>250 and<1000μm)and high(HVG:≥1000μm).Multinomial logistic regression(MLR)was used to find the sub-optimal vault predictors.Results MLR showed that CLR,ICL size minus the ATA(ICL size-ATA),age,ICL spherical equivalent(ICLSE)and ICL size as contributing factors for sub-optimal vaults(pseudo-R2=0.40).Increased CLR(OR:1.01,CI:1.00–1.01)and less myopic ICLSE(OR:1.22,CI:1.07–1.40)were risk factors for low vaults.Larger ICL size-ATA(OR:41.29,CI:10.57–161.22)and the 13.7 mm ICL(OR:7.08,CI:3.16–15.89)were risk factors for high vaults,whereas less myopic ICLSE(OR:0.85,CI:0.76–0.95)and older age(OR:0.92,CI:0.88–0.98)were protective factors.Conclusion High CLR and low ICLSE were the major risk factors in eyes presenting low vaults.In the opposite direction,ICL size-ATA was the major contributor for high vaults.This relationship was more critical in higher myopic ICLSE,younger eyes and when 13.7 mm ICL were used.The findings show that factors influencing the vault have differentiated weight of influence depending on the type of vault(low,optimal or high). 展开更多
关键词 implantable collamer lens Refractive surgery VAULT Risk factors
原文传递
Biometric and ICL-related risk factors associated to sub-optimal vaults in eyes implanted with implantable collamer lenses 被引量:7
17
作者 Santiago Cerpa Manito Angel Sánchez Trancón +2 位作者 Oscar Torrado Sierra António Manuel Baptista Pedro Miguel Serra 《Eye and Vision》 SCIE CSCD 2021年第1期253-262,共10页
Background:To identify biometric and implantable collamer lens(ICL)-related risk factors associated with suboptimal postoperative vault in eyes implanted with phakic ICL.Methods:This study reports a retrospective case... Background:To identify biometric and implantable collamer lens(ICL)-related risk factors associated with suboptimal postoperative vault in eyes implanted with phakic ICL.Methods:This study reports a retrospective case series of the first operated eye in 360 patients implanted with myopic spherical or toric ICL.Preoperatively,white-to-white(WTW),central keratometry(Kc)and central corneal thickness(CCT)were measured using the Pentacam.Anterior-segment optical coherence tomography(AS-OCT,Visante)was applied preoperatively for measuring the horizontal anterior-chamber angle-to-angle distance(ATA),internal anterior chamber depth(ACD),crystalline lens rise(CLR),anterior-chamber angle(ACA)and postoperatively the vault.Eyes were divided into three vault groups:low(LVG:≤250μm),optimal(OVG:>250 and<1000μm)and high(HVG:≥1000μm).Multinomial logistic regression(MLR)was used to find the sub-optimal vault predictors.Results:MLR showed that CLR,ICL size minus the ATA(ICL size-ATA),age,ICL spherical equivalent(ICLSE)and ICL size as contributing factors for sub-optimal vaults(pseudo-R2=0.40).Increased CLR(OR:1.01,CI:1.00-1.01)and less myopic ICLSE(OR:1.22,CI:1.07-1.40)were risk factors for low vaults.Larger ICL size-ATA(OR:41.29,CI:10.57-161.22)and the 13.7mm ICL(OR:7.08,CI:3.16-15.89)were risk factors for high vaults,whereas less myopic ICLSE(OR:0.85,CI:0.76-0.95)and older age(OR:0.92,CI:0.88-0.98)were protective factors.Conclusion:High CLR and low ICLSE were the major risk factors in eyes presenting low vaults.In the opposite direction,ICL size-ATA was the major contributor for high vaults.This relationship was more critical in higher myopic ICLSE,younger eyes and when 13.7mm ICL were used.The findings show that factors influencing the vault have differentiated weight of influence depending on the type of vault(low,optimal or high). 展开更多
关键词 implantable collamer lens Refractive surgery VAULT Risk factors
原文传递
In vivo optical quality of posterior-chamber phakic implantable collamer lenses with a central port 被引量:3
18
作者 Robert Montés-Micó Francisco Pastor-Pascual +2 位作者 Enrique Artiaga-Elordi Ramón Ruiz-Mesa Pedro Tañá-Rivero 《Eye and Vision》 SCIE CSCD 2021年第1期295-302,共8页
Background:The aim of this review is to summarize the optical quality results in patients following the implantation of the V4c implantable collamer lens with a central port(ICL,STAAR Surgical Inc.).Main text:A litera... Background:The aim of this review is to summarize the optical quality results in patients following the implantation of the V4c implantable collamer lens with a central port(ICL,STAAR Surgical Inc.).Main text:A literature search in several databases was carried out to identify those publications,both prospective,retrospective and/or comparative with other refractive surgery procedures,reporting optical outcomes of patients who were implanted with the V4c ICL model.A total of 17 clinical studies published between 2012 and 2021 were included in this review.A detailed analysis of the available data was performed including number of eyes,follow-up and preoperative spherical equivalent.Specifically,the review focused on several optical parameters including higher-order aberrations(HOAs),modulation transfer function(MTF)cut-off frequency and Strehl ratio.This review encompassed a total of 817 eyes measured using different optical devices based on Hartmann-Shack,retinal image quality measurement and ray-tracing technologies at different follow-ups.Conclusions:The outcomes found in this review lead us to conclude that the ICL V4c model provides good optical quality,by means of different metrics,when implanted. 展开更多
关键词 implantable collamer lens PHAKIC Optical quality Higher order aberrations Modulation transfer function
原文传递
Analysis of macular microvasculature and thickness after ICL implantation in patients with myopia using optical coherence tomography 被引量:3
19
作者 Qiu-Jian Zhu Meng-Yu Wang +4 位作者 Peng Yu Xiao-Suo Liang Lie Ma Hai-Xiang Xiao You Yuan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第12期1948-1954,共7页
AIM:To investigate changes in macular vessels and thickness in myopic eyes after intraocular collamer lens(ICL)implantation using quantitative optical coherence tomography angiography(OCTA).METHODS:This retrospective ... AIM:To investigate changes in macular vessels and thickness in myopic eyes after intraocular collamer lens(ICL)implantation using quantitative optical coherence tomography angiography(OCTA).METHODS:This retrospective included 73 myopic eyes of 73 patients(average age,27.53±6.16 y)who underwent ICL implantation(28 eyes were Toric ICL).Axial length(AL),uncorrected visual acuity(UCVA),refractive dioptre(RD),intraocular pressure(IOP)and OCTA were measured and compared with before and 1 wk,1,and 3 mo after surgery.OCTA was used to image vessel density(VD)and skeleton density(SD)in both the superficial(SCP)and deep capillary plexus(DCP).Central retinal thickness(CRT)and ganglion cellinner plexiform layer thickness(GCT)were also measured.Changes between pre-and postoperative measurements were analysed by repeated measures analysis of variance.RESULTS:Compared with preoperative data,postoperative data on UCVA revealed significant improvements in all patients(P<0.05).However,there was no significant difference in IOP.After the operation,CRT and GCT exhibited significant changes(P<0.05).Among these measures,CRT was significantly higher at one and three months postoperative(all P<0.01).GCT was significantly higher at 1 wk,1,and 3 mo postoperative(all P<0.01).Changes in VD and SD were nonsignificant in both the SCP and DCP.There was no difference in postoperative changes between the ICL and Toric ICL groups.CONCLUSION:ICL and Toric ICL implantation both have good efficacy and safety for myopic eyes,but macular area changes that occur after surgery need attention. 展开更多
关键词 intraocular collamer lens implantation vessel density macular thickness optical coherence tomography angiography
下载PDF
Seven-year follow-up of posterior chamber phakic intraocular lens with central port design 被引量:4
20
作者 Luis Fernández-Vega-Cueto Belén Alfonso-Bartolozzi +2 位作者 Carlos Lisa David Madrid-Costa JoséF.Alfonso 《Eye and Vision》 SCIE CSCD 2021年第1期223-231,共9页
Background:To assess the clinical outcomes of the Visian Implantable Collamer Lens(ICL)with a central port throughout 7 years of follow-up.Methods:Eighty-four eyes of 52 patients were evaluated over a follow-up period... Background:To assess the clinical outcomes of the Visian Implantable Collamer Lens(ICL)with a central port throughout 7 years of follow-up.Methods:Eighty-four eyes of 52 patients were evaluated over a follow-up period of 7 years after V4c ICL implantation.Uncorrected(UDVA)and corrected(CDVA)distance visual acuities,refraction,intraocular pressure(IOP),endothelial cell density(ECD)and vault were analysed.Results:The mean postoperative UDVA(logMAR)was 0.04±0.11,0.13±0.19 and 0.17±0.23 at 1-,5-and 7-years,respectively(P<0.0001).The mean CDVA(logMAR)remains unchanged throughout a 7-year follow-up period(0.02±0.08 and 0.02±0.08,at 5-and 7-years,respectively,P=0.2).At all follow-up visits,more than 95%of the eyes achieved a CDVA of 20/25 or better and more than 85%a CDVA of 20/20.At the end of the follow-up(7 years),no eye lost more lines of CDVA,56 eyes(66.7%)and 28 eyes(33.3%)gained lines of CDVA.At 7-years,the spherical equivalent was−0.62±0.62 D.No significant increase in IOP(>20 mmHg or an increase higher than 5 mmHg)occurred in any case throughout the 7-year of follow-up.The loss in ECD from the preoperative baseline at the last follow-up visit was 2.6%.No intraoperative or postoperative complications or adverse events occurred during the follow-up period.Conclusions:The outcomes of this study show the long-term viability of the V4c ICL implantation as a surgical option for the correction of myopia. 展开更多
关键词 implantable collamer lens ICL MYOPIA LONG-TERM
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部