期刊文献+
共找到2,310篇文章
< 1 2 116 >
每页显示 20 50 100
Additively manufactured Ti–Ta–Cu alloys for the next-generation load-bearing implants 被引量:1
1
作者 Amit Bandyopadhyay Indranath Mitra +4 位作者 Sushant Ciliveri Jose D Avila William Dernell Stuart B Goodman Susmita Bose 《International Journal of Extreme Manufacturing》 SCIE EI CAS CSCD 2024年第1期353-374,共22页
Bacterial colonization of orthopedic implants is one of the leading causes of failure and clinical complexities for load-bearing metallic implants. Topical or systemic administration of antibiotics may not offer the m... Bacterial colonization of orthopedic implants is one of the leading causes of failure and clinical complexities for load-bearing metallic implants. Topical or systemic administration of antibiotics may not offer the most efficient defense against colonization, especially in the case of secondary infection, leading to surgical removal of implants and in some cases even limbs. In this study, laser powder bed fusion was implemented to fabricate Ti3Al2V alloy by a 1:1 weight mixture of CpTi and Ti6Al4V powders. Ti-Tantalum(Ta)–Copper(Cu) alloys were further analyzed by the addition of Ta and Cu into the Ti3Al2V custom alloy. The biological,mechanical, and tribo-biocorrosion properties of Ti3Al2V alloy were evaluated. A 10 wt.% Ta(10Ta) and 3 wt.% Cu(3Cu) were added to the Ti3Al2V alloy to enhance biocompatibility and impart inherent bacterial resistance. Additively manufactured implants were investigated for resistance against Pseudomonas aeruginosa and Staphylococcus aureus strains of bacteria for up to 48 h. A 3 wt.% Cu addition to Ti3Al2V displayed improved antibacterial efficacy, i.e.78%–86% with respect to CpTi. Mechanical properties for Ti3Al2V–10Ta–3Cu alloy were evaluated, demonstrating excellent fatigue resistance, exceptional shear strength, and improved tribological and tribo-biocorrosion characteristics when compared to Ti6Al4V. In vivo studies using a rat distal femur model revealed improved early-stage osseointegration for alloys with10 wt.% Ta addition compared to CpTi and Ti6Al4V. The 3 wt.% Cu-added compositions displayed biocompatibility and no adverse infammatory response in vivo. Our results establish the Ti3Al2V–10Ta–3Cu alloy’s synergistic effect on improving both in vivo biocompatibility and microbial resistance for the next generation of load-bearing metallic implants. 展开更多
关键词 TI6AL4V load-bearing implants additive manufacturing 3D printing antibacterial performance
下载PDF
Elimination of methicillin‑resistant Staphylococcus aureus biofilms on titanium implants via photothermally‑triggered nitric oxide and immunotherapy for enhanced osseointegration
2
作者 Yong‑Lin Yu Jun‑Jie Wu +5 位作者 Chuan‑Chuan Lin Xian Qin Franklin R.Tay Li Miao Bai‑Long Tao Yang Jiao 《Military Medical Research》 SCIE CAS CSCD 2024年第2期157-179,共23页
Background:Treatment of methicillin-resistant Staphylococcus aureus(MRSA)biofilm infections in implant placement surgery is limited by the lack of antimicrobial activity of titanium(Ti)implants.There is a need to expl... Background:Treatment of methicillin-resistant Staphylococcus aureus(MRSA)biofilm infections in implant placement surgery is limited by the lack of antimicrobial activity of titanium(Ti)implants.There is a need to explore more effective approaches for the treatment of MRSA biofilm infections.Methods:Herein,an interfacial functionalization strategy is proposed by the integration of mesoporous polydopamine nanoparticles(PDA),nitric oxide(NO)release donor sodium nitroprusside(SNP)and osteogenic growth peptide(OGP)onto Ti implants,denoted as Ti-PDA@SNP-OGP.The physical and chemical properties of Ti-PDA@SNP-OGP were assessed by scanning electron microscopy,X-ray photoelectron spectroscope,water contact angle,photothermal property and NO release behavior.The synergistic antibacterial effect and elimination of the MRSA biofilms were evaluated by 2′,7′-dichlorofluorescein diacetate probe,1-N-phenylnaphthylamine assay,adenosine triphosphate intensity,O-nitrophenyl-β-D-galactopyranoside hydrolysis activity,bicinchoninic acid leakage.Fluorescence staining,assays for alkaline phosphatase activity,collagen secretion and extracellular matrix mineralization,quantitative real‑time reverse transcription‑polymerase chain reaction,and enzyme-linked immunosorbent assay(ELISA)were used to evaluate the inflammatory response and osteogenic ability in bone marrow stromal cells(MSCs),RAW264.7 cells and their co-culture system.Giemsa staining,ELISA,micro-CT,hematoxylin and eosin,Masson's trichrome and immunohistochemistry staining were used to evaluate the eradication of MRSA biofilms,inhibition of inflammatory response,and promotion of osseointegration of Ti-PDA@SNP-OGP in vivo.Results:Ti-PDA@SNP-OGP displayed a synergistic photothermal and NO-dependent antibacterial effect against MRSA following near-infrared light(NIR)irradiation,and effectively eliminated the formed MRSA biofilms by inducing reactive oxygen species(ROS)-mediated oxidative stress,destroying bacterial membrane integrity and causing leakage of intracellular components(P<0.01).In vitro experiments revealed that Ti-PDA@SNP-OGP not only facilitated osteogenic differentiation of MSCs,but also promoted the polarization of pro-inflammatory M1 macrophages to the anti-inflammatory M2-phenotype(P<0.05 or P<0.01).The favorable osteo-immune microenvironment further facilitated osteogenesis of MSCs and the anti-inflammation of RAW264.7 cells via multiple paracrine signaling pathways(P<0.01).In vivo evaluation confirmed the aforementioned results and revealed that Ti-PDA@SNP-OGP induced ameliorative osseointegration in an MRSA-infected femoral defect implantation model(P<0.01).Conclusions:Ti-PDA@SNP-OGP is a promising multi-functional material for the high-efficient treatment of MRSA infections in implant replacement surgeries. 展开更多
关键词 Polydopamine nanoparticles Methicillin-resistant Staphylococcus aureus Nitric oxide OSSEOINTEGRATION Osteo-immunomodulation Photothermal effect Titanium implants
下载PDF
HVOF-sprayed HAp/S53P4 BG composite coatings on an AZ31 alloy for potential applications in temporary implants
3
作者 Carlos A.Poblano-Salas John Henao +6 位作者 Astrid L.Giraldo-Betancur Paola Forero-Sossa Diego German Espinosa-Arbelaez Jorge A.González-Sánchez Luis R.Dzib-Pérez Susana T.Estrada-Moo Idelfonso E.Pech-Pech 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第1期345-360,共16页
Bioactive thermal spray coatings produced via high-velocity oxygen fuel spray(HVOF)from hydroxyapatite(HAp)and bioactive glasses(BG)have the potential to be employed on temporary implants due to the ability of both HA... Bioactive thermal spray coatings produced via high-velocity oxygen fuel spray(HVOF)from hydroxyapatite(HAp)and bioactive glasses(BG)have the potential to be employed on temporary implants due to the ability of both HAp and BG to dissolve and promote osseointegration,considering that both phases have different reaction and dissolution rates under in-vitro conditions.In the present work,75%wt.HAp-25%wt.S53P4 bioactive glass powders were HVOF-sprayed to obtain HAp/S53P4 BG composite coatings on a bioresorbable AZ31 alloy.The study is focused on exploring the effect of the stand-off distance and fuel/oxygen ratio variation as HVOF parameters to obtain stable structural coatings and to establish their effect on the phases and microstructure produced in those coatings.Different characterization techniques,such as scanning electron microscopy,X-ray diffraction,and Fourier transform infrared spectroscopy,were employed to characterize relevant structural and microstructural properties of the composite coatings.The results showed that thermal gradients during coating deposition must be managed to avoid delamination due to the high temperature achieved(max 550℃)and the differences in coefficients of thermal expansion.It was also found that both spraying distance and oxygen/fuel ratio allowed to keep the hydroxyapatite as the main phase in the coatings.In addition,in-vitro electrochemical studies were performed on the obtained HAp/S53P4 BG composite coatings and compared against the uncoated AZ31 alloy.The results showed a significant decrease in hydrogen evolution(at least 98%)when the bioactive coating was applied on the Mg alloy during evaluation in simulated body fluid(SBF). 展开更多
关键词 Coatings Composites Thermal spray Temporary implants Hydrogen evolution
下载PDF
Investigation of bioactivity and biodegradability of Mg-bioceramic implants:An in vitro study for biomedical applications
4
作者 ESMAIELZADEH Omar EIVANI Ali Reza +3 位作者 MEHDIZADE Maryam TAJALI Nooshin S.H.MOUSAVI ANIJDAN JAFARIAN Hamid Reza 《Journal of Central South University》 SCIE EI CAS CSCD 2024年第9期2992-3013,共22页
In this study,Mg-based composites,by the addition of ZnO,Ca_(2)ZnSi_(2)O_(7),Ca_(2)MgSi_(2)O_(7),and CaSiO_(3)as bioactive agents,were fabricated using friction stir processing.The microstructure and in vitro assessme... In this study,Mg-based composites,by the addition of ZnO,Ca_(2)ZnSi_(2)O_(7),Ca_(2)MgSi_(2)O_(7),and CaSiO_(3)as bioactive agents,were fabricated using friction stir processing.The microstructure and in vitro assessment of bioactivity,biodegradation rate,and corrosion behavior of the resultant composites were investigated in simulated body fluid(SBF).The results showed that during the immersion of composites in SBF for 28 d,due to the release of Ca^(2+)and PO_(4)^(3-)ions,hydroxyapatite(HA)crystals with cauliflower shaped morphology were deposited on the surface of composites,confirming good bioactivity of composites.In addition,due to the uniform distribution of bioceramic powders throughout Mg matrix,grain refinement of the Mg matrix,and uniform redistribution of secondary phase particles,the polarization resistance increased,and the biodegradation rate of composites significantly reduced compared to monolithic Mg matrix.The polarization corrosion resistance of Mg-ZnO increased from 0.216 to 2.499 kΩ/cm^(2)compared to monolithic Mg alloy.Additionally,Mg-ZnO composite with the weight loss of 0.0217 g after 28 d immersion showed lower weight loss compared to other samples with increasing immersion time.Moreover,Mg-ZnO composite with the biodegradation rate of 37.71 mm/a exhibited lower biodegradation rate compared to other samples with increasing immersion time. 展开更多
关键词 Mg-bioceramic bone implants friction stir processing bioactivity in vitro biodegradation BIOCORROSION
下载PDF
Digital manufacturing of personalized magnesium implants through binder jet additive manufacturing and automated post machining
5
作者 Mojtaba Salehi Dennis Wee Keong Neo +5 位作者 Viktor Rudel Marc Stautner Philipp Ganser Su Xia Zhang Hang Li Seet Mui Ling Sharon Nai 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第8期3308-3324,共17页
While magnesium(Mg)is a promising material for personalized temporary implants,the lack of a digital manufacturing solution for Mg implants impedes its potential progress.This study introduces a hybrid manufacturing p... While magnesium(Mg)is a promising material for personalized temporary implants,the lack of a digital manufacturing solution for Mg implants impedes its potential progress.This study introduces a hybrid manufacturing process that integrates binder jet additive manufacturing with automated dry post-machining to enable end-to-end digital manufacturing of personalized Mg implants.Spherical cap-shaped Mg implants were additively manufactured through binder jetting.These implants were placed on graphite flakes during sintering as a potential non-reactive support material,allowing unrestricted shrinkage of 15.2%to a relative density of 87%.Microstructural and dimensional analysis revealed consistent interconnected porous microstructures with a shrinkage distortion within±0.2 mm of the original digital drawing.High-speed dry milling of the sintered samples,assessed via an orthogonal cutting test,identified the optimized cutting parameters.A three-step machining process for automated 5-axis machining,along with clamping strategies,referencing,and an adaptive plug-in,were successfully implemented.The automated dry machining on binder-jet printed Mg implants resulted in an average roughness of<1.3μm with no defects.In summary,this work introduces a robust digital manufacturing solution to advance the transformative landscape of Mg implants and scaffolds.©2024 Chongqing University.Publishing services provided by Elsevier B.V.on behalf of KeAi Communications Co.Ltd. 展开更多
关键词 SINTERING Binder jet additive manufacturing Computer-aided manufacturing Orthogonal cutting Magnesium implants
下载PDF
Complicated calcified alloplastic implants in the nasal dorsum:A clinical analysis
6
作者 Yong-Seon Hwang Taek-Kyun Kim +2 位作者 Dong-Jun Yang Si-Hyong Jang Da-Woon Lee 《World Journal of Clinical Cases》 SCIE 2024年第18期3351-3359,共9页
BACKGROUND In rhinoplasty,calcification around silicone implants is frequently observed in the tip dorsum(TD)area.Additionally,based on a review of various literature,it is presumed that calcification in silicone impl... BACKGROUND In rhinoplasty,calcification around silicone implants is frequently observed in the tip dorsum(TD)area.Additionally,based on a review of various literature,it is presumed that calcification in silicone implants occurs due to both inflammatory chemical reactions and physical friction against the tissue.The calcification of nasal silicone implants not only results in the functional loss of the implants,but also leads to material deformation.However,there is a lack of research on calcification of nasal silicone implants in the current literature.AIM To elucidate various clinical characteristics of calcification around nasal silicone implants,using histological and radiological analysis.METHODS This study analyzed data from 16 patients of calcified nasal implants,who underwent revision rhinoplasty for various reasons after undergoing augmentation rhinoplasty with silicone implants.The collected data included information on implant duration,implant types,location of calcification,presence of inflammatory reactions,and computed tomography(CT)scans.RESULTS The most common location of calcification,as visually analyzed,was in the TD area,accounting for 56%.Additionally,the analysis of CT scans revealed a trend of increasing Hounsfield Unit values for calcification with the duration of implantation,although this trend was not statistically significant(P=0.139).CONCLUSION Our study shows that reducing the frequency of calcification may be achievable by using softer silicone implants and by minimizing the damage to perioperative tissues. 展开更多
关键词 Silicone implants RHINOPLASTY CALCIFICATION COMPLICATION Hounsfield unit
下载PDF
Review on the Fabrication of Surface Functional Structures for Enhancing Bioactivity of Titanium and Titanium Alloy Implants
7
作者 Heng Tang Jiaxiang Xu +4 位作者 Bin Guo Yansong Xie Yalong Sun Yanjun Lu Yong Tang 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2024年第4期23-49,共27页
Titanium and its alloys have been widely applied in many biomedical fields because of its excellent mechanical properties,corrosion resistance and good biocompatibility.However,problems such as rejection,shedding and ... Titanium and its alloys have been widely applied in many biomedical fields because of its excellent mechanical properties,corrosion resistance and good biocompatibility.However,problems such as rejection,shedding and infection will occur after titanium alloy implantation due to the low biological activity of titanium alloy surface.The structures with specific functions,which can enhance osseointegration and antibacterial properties,are fabricated on the surface of titanium implants to improve the biological activity between the titanium implants and human tissues.This paper presents a comprehensive review of recent developments and applications of surface functional structure in titanium and titanium alloy implants.The applications of surface functional structure on different titanium and titanium alloy implants are introduced,and their manufacturing technologies are summarized and compared.Furthermore,the fabrication of various surface functional structures used for titanium and titanium alloy implants is reviewed and analyzed in detail.Finally,the challenges affecting the development of surface functional structures applied in titanium and titanium alloy implants are outlined,and recommendations for future research are presented. 展开更多
关键词 Surface functional structure Titanium implant Manufacturing technology Bioactivity
下载PDF
In vivo and in vitro study of resorbable magnesium wires for medical implants:Mg purity,surface quality,Zn alloying and polymer coating
8
作者 K.Tesar J.Luňácková +12 位作者 M.Jex M.Žaloudková R.Vrbová M.Bartoš P.Klein L.Vištejnová J.Dušková E.Filová Z.Sucharda M.Steinerová S.Habr K.Balík A.Singh 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第6期2472-2488,共17页
Magnesium is an excellent material in terms of biocompatibility and its corrosion products can serve as an active source for new bone formation.However,localized corrosion and H_(2)generation limit the potential of Mg... Magnesium is an excellent material in terms of biocompatibility and its corrosion products can serve as an active source for new bone formation.However,localized corrosion and H_(2)generation limit the potential of Mg-based implants.Utilizing low-alloyed Mg-Zn wires can strongly reduce problems with large H_(2)bubbles and improve the mechanical properties considerably while maintaining excellent long-term biocompatibility.Acidic pickling and a polymer coating can be effectively used to lower the rate of in vivo degradation.In this work,microstructural,mechanical,and in vitro characterization of 250μm and 300μm extruded wires made from ultra-pure Mg,commercially pure Mg,Mg-0.15Zn,Mg-0.4Zn and Mg-1Zn was performed.Additionally,Mg-0.4Zn wires together with a variant coated with a copolymer of L-lactide andε-caprolactone were tested in vivo on artificially damaged Wistar rat femurs.Based on the observed Mg-induced osteogenesis,polymer-coated Mg wires with a small addition of Zn are a perspective material for bone-support applications,such as cerclage and fixation wires. 展开更多
关键词 MAGNESIUM Resorbable Mg wire Mg-Zn implant degradation Biocompatibility study Zn grain boundary segregation
下载PDF
Complications of dexamethasone implants:risk factors,prevention,and clinical management
9
作者 Nil Celik Ramin Khoramnia +2 位作者 Gerd.U Auffarth Saadettin Sel Christian S Mayer 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第10期1612-1620,共9页
AIM:To evaluate major complications after intravitreal injection of dexamethasone implants(Ozurdex)and their clinical management.METHODS:In a retrospective observational study between 2014 and 2016 at two university h... AIM:To evaluate major complications after intravitreal injection of dexamethasone implants(Ozurdex)and their clinical management.METHODS:In a retrospective observational study between 2014 and 2016 at two university hospitals,we reviewed the clinical records of 1241 consecutive macular edema patients treated with the dexamethasone implant,and separated severe adverse events in the injection procedure from those that were post-injection complications.We evaluated the cause and the outcomes in each case.RESULTS:In twenty-one procedures(1.69%)we noticed significant complications during and after intravitreal injection of the dexamethasone implant.Complications related to the injection procedure were in one case,that a second implant was injected by mistake in the same eye on the same day.In another case,the implant lodged in the sclera during retraction of the injector needle.Leaking scleral tunnel at the injection site led to hypotony in another case.There were 10 cases of post-injection displacement of the implant into the anterior chamber and one case with a migrated and trapped device between the intraocular lens and an artificial iris.Displacement typically occurred in patients with preexisting risk factors:eyes with complicated intraocular lens implantation,iris reconstruction or iris defects or pseudophakic eyes after vitrectomy were prone to develop this complication.Displacement led to secondary corneal decompensation with pseudohypopyon.One case developed an endophthalmitis,and we observed four cases of retinal detachment.Two eyes presented with long-lasting hypotony due to ciliary insufficiency.CONCLUSION:Treatment with the dexamethasone implant may cause various expected or unexpected complications that may have serious consequences for the patient and require further surgery.To reduce complications,clinicians should evaluate certain risk factors before scheduling patients for dexamethasone implant treatment and use proper injection techniques. 展开更多
关键词 intravitreal implants dexamethasone implants Ozurdex intravitreal injection slow release drug
下载PDF
Finite element analysis of stress at implant-bone interface of dental implants with different structures 被引量:3
10
作者 陈良建 何浩 +3 位作者 李益民 李挺 郭小平 汪瑞芳 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2011年第7期1602-1610,共9页
The effect of structure,elastic modulus and thickness of lower modulus layer in porous titanium implants on the stress distribution at the implant-bone interface was investigated.Three-dimensional finite element model... The effect of structure,elastic modulus and thickness of lower modulus layer in porous titanium implants on the stress distribution at the implant-bone interface was investigated.Three-dimensional finite element models of different titanium implants were constructed.The structures of the implants included the whole lower modulus style (No.1),bio-mimetic style (No.2),the whole lower modulus style in cancellous bone (No.3) and the whole dense style No.4.The stress distributions at bone-implant interface under static loading were analyzed using Ansys Workbench 10.0 software.The results indicated that the distribution of interface stress is strongly depended on the structure of the implants.The maximum stresses in cancellous bone and root region of implant No.2 are lower than those in the other three implants.A decrease in the modulus of the low modulus layer facilitates the interface stress transferring.Increasing the thickness of the low modulus layer can reduce the stress and induce a more uniform stress distribution at the interface.Among the four implants,biomimetic style implant No.2 is superior in transferring implant-bone interface stress to surrounding bones. 展开更多
关键词 titanium implant elastic modulus finite element analysis porous structure
下载PDF
Biodegradable Mg alloys for orthopedic implants——A review 被引量:21
11
作者 Violeta Tsakiris Christu Tardei Florentina Marilena Clicinschi 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2021年第6期1884-1905,共22页
The last decade has seen a significant growth in the market for alloys used for implants,especially for those intended for orthopedic implants.Research into biodegradable magnesium-based alloys has made great strides ... The last decade has seen a significant growth in the market for alloys used for implants,especially for those intended for orthopedic implants.Research into biodegradable magnesium-based alloys has made great strides in this period,so huge progress has been made in their use in the medical industry.The important factors that led to the intensification of research in this regard,were social but also economic,wanting to improve the quality of life,by reducing the use of conventionally permanent metallic implants(stainless steel,cobalt-based alloys,and titanium alloys)which involve the second implant removal surgery and other undesirable effects(stress shielding and metal ion releases),with a negative impact on the emotional and physical condition of patients,and by significantly reducing the costs for both the patient and the health system in the field of orthopedics.This paper refers to the impact and importance of biodegradable Mg alloys,reviewing the beginning of their development,the significant characteristics that make them so desirable for such applications(orthopedic implants)but also the characteristics that must be modulated(corrosion rate and mechanical properties)to arrive at the ideal product for the targeted application.It highlights,in detail,the mechanism and aspects related to the corrosion behaviour of Mg alloys,electrochemical characterization techniques/methods,as well as strategies to improve the corrosion behaviour and mechanical properties of these types of biodegradable alloys.The means of optimization,the category and the effect of the alloying elements,the design criteria,the requirements that the implants of biodegradable alloys Mg-based must meet and the aspects related to their efficiency are also presented.Finally,the potential applications in the specialized clinics,as well as the final products currently used and made by important prestigious companies in the world are approached. 展开更多
关键词 Mg alloys BIODEGRADABLE Orthopedic implants CORROSION DEGRADATION Biomedical applications
下载PDF
A comprehensive review on biocompatible Mg-based alloys as temporary orthopaedic implants:Current status,challenges,and future prospects 被引量:10
12
作者 Darothi Bairagi Sumantra Mandal 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2022年第3期674-722,共49页
Mg and its alloys are drawing huge attention since the last two decades as a viable option for temporary implants applications.A commendable progress has already been made in the development of these alloys.The biodeg... Mg and its alloys are drawing huge attention since the last two decades as a viable option for temporary implants applications.A commendable progress has already been made in the development of these alloys.The biodegradable nature of Mg,appreciable biocompatibility of elemental Mg,and its close resemblance to natural bone in terms of density and elastic modulus make them highly preferable option amongst other available alternatives in this field.This review article presents an overview covering the recent advancements made in the field of Mg-based biodegradable implants for orthopaedic implant applications.The paper focuses on alloy development and fabrication techniques,the state of the art of important Mg-based alloy systems in terms of their mechanical properties,in-vitro and in-vivo degradation behaviour and cytotoxicity.Further,the paper reviews the current progress achieved in the clinical transition of Mg-based alloys for orthopaedic fixtures.The review also includes the degradation mechanisms of the alloys in physiological environment and highlights the mismatch existing between the rate of bone healing and alloy degradation due to rapid corrosion of the alloys in such environment,which has still restricted their widespread application.Finally,the surface coating techniques available for the alloys as an effective way to reduce the degradation rate are reviewed,followed by a discussion on the future research prospects. 展开更多
关键词 Mg-based alloys BIOMATERIALS Temporary implants BIOCOMPATIBILITY Degradation behaviour orthopaedic fixtures.
下载PDF
Effect of basic fibroblast growth factor(bFGF) on the treatment of exposure of the orbital implants 被引量:13
13
作者 CUI Hong-guang LI Hui-yan 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2007年第9期620-625,共6页
Objective: To evaluate the efficacy and the indication of basic fibroblast growth factor (bFGF) in the treatment of exposure of orbital implants. Design: Retrospective and observational case series. Methods: We review... Objective: To evaluate the efficacy and the indication of basic fibroblast growth factor (bFGF) in the treatment of exposure of orbital implants. Design: Retrospective and observational case series. Methods: We reviewed 41 patients (41 eyes) suffering exposure of orbital implants from Jan. 2000 to June 2006. The study group patients with mild exposure received com-bined treatment with bFGF and antibiotic drops, and while the control group patients with mild exposure were treated with anti-biotic drops only. The study group patients with moderate and severe exposure received combined treatment with bFGF and antibiotic drops, and after 2 months they were subjected to amniotic membrane transplantation, while the control group patients with moderate and severe exposure underwent amniotic membrane transplantation after using antibiotic drops. Observation of the growth of conjunctival epithelium and comparison of the healing rate of the two groups. Results: The healing rates of the mild, moderate and severe exposure study group were 100% and 92.3%. The healing rates of the mild, moderate and severe exposure control group were 55.6% and 66.7% respectively. The difference of the healing rates of the mild exposure study group and the control group was significant (P=0.033). And the difference of the healing rates of the moderate and severe exposure study group and the control group was not significant (P=0.167). Conclusion: bFGF may promote obviously the healing of orbital implant exposure, particularly it can be the first choice for the treatment of mild degree exposure. For the moderate and severe cases, it can be administered before surgical repair to enhance neovascularization and will tend to increase the success rate of surgical repair. 展开更多
关键词 EXPOSURE Orbital implants Basic fibroblast growth factor (bFGF)
下载PDF
Sensory innervation around immediately vs. delayed loaded implants: a pilot study 被引量:7
14
作者 Yan Huang Jeroen van Dessel +6 位作者 Wendy Martens Ivo Lambrichts Wei-Jian Zhong Guo-Wu Ma Dan Lin Xin Liang Reinhilde Jacobs 《International Journal of Oral Science》 SCIE CAS CSCD 2015年第1期49-55,共7页
Although neurophysiological and psychophysical proof of osseoperception is accumulating, histomorphometric evidence for the neural mechanisms of functional compensation following immediate and delayed implant loading ... Although neurophysiological and psychophysical proof of osseoperception is accumulating, histomorphometric evidence for the neural mechanisms of functional compensation following immediate and delayed implant loading is still lacking. For this randomized split-mouth study, six mongrel dogs randomly received one of four treatment protocols at 36 implant-recipient sites over 16 weeks (third maxillary incisor, third and fourth mandibular premolar): immediate implant placement and immediate loading (liP+ IL); delayed implant placement and delayed loading (DIP+DL); delayed implant placement and immediate loading (DIP+IL); and natural extraction socket healing (control). Histomorphometry was performed in the peri-implant bone and soft tissues within 300 pm around the implants. Immunocytochemistry and transmission electron microscopy were used to confirm the presence of neural structures and to reveal their ultrastructural characteristics, respectively. Myelinated nerve fibres densely populated the peri-implant crestal gingival and apical regions, although they were also identified in the woven bone and in the osteons near the implant threads. Compared with the control group in the mandible, the group that received IIP+IL showed a higher innervation (in N.mm^-2, 5.94±1.12 vs. 3.15±0.63, P〈0.001) and smaller fibre diameter (in pm, 1.37±0.05 vs. 1.64±0.13, P=0.016), smaller axon diameter (in pm, 0.89±0.05 vs. 1.24±0,10, P=0.009) and g-ratio (0.64±0.04 vs. 0.76±0.05, P〈0.001) in the middle region around the implants. Compared with DIP+IL in the mandible, IIP+IL had a higher nerve density (in N.mm^-2, 13.23±2.54 vs. 9.64±1.86, P=0.027), greater fibre diameter (in pm, 1.32±0.02 vs. 1.20±0.04, P=0.021), greater axon diameter (in μm, 0.92±0.01 vs. 0.89±0.03, P=-0.035) and lower g-ratio (0.69±0.01 vs. 0.74±0.01, P=-0.033) in the apical region around the implants. It may be assumed that the treatment protocol with liP+ IL is the preferred method to allow optimized peri-implant re-innervation, but further functional measurements are still required. 展开更多
关键词 animal experiments dental implants HISTOMORPHOMETRY immediate loading MECHANORECEPTOR myelinated nerve fibres osseoperception
下载PDF
Experiment research of cisplatin implants inhibiting transplantation tumor growth and regulating the expression of KLK7 and E-cad of tumor-bearing mice with gastric cancer 被引量:6
15
作者 Gui-Feng Zhuang Yan Tan +2 位作者 Yuan-Zheng Yang Jie-Wei Zhang Jing Tang 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2016年第6期586-590,共5页
Objective: To study the influence of cisplatin implants on transplantation tumor growth and the expression of tissue kallikrein-7(KLK7) and E-cadherin(E-cad) in tumor-bearing mice with gastric cancer. Methods: BALB/c ... Objective: To study the influence of cisplatin implants on transplantation tumor growth and the expression of tissue kallikrein-7(KLK7) and E-cadherin(E-cad) in tumor-bearing mice with gastric cancer. Methods: BALB/c nude mice were collected as experimental animal and were randomly divided into model control group(Group A), tail intravenous injection of cisplatin group(Group B), intratumor injection of cisplatin group(Group C) and cisplatin implants treatment group(Group D). After the drugs intervening, the weight and volume of transplantation tumors were measured on Day 20, Day 30 and Day 40 and serum and KLK7 and E-cad contents in transplanted tumor tissue were examined. Results: On Day 20, Day 30 and Day 40 after treatment, the weight and volume of transplantation tumors of tumorbearing mice in four groups were different(Group A > Group B > Group C > Group D). The contents of KLK-7 and E-cad in tumor tissue and serum of tumor-bearing mice in four groups were different(Group A > Group B > Group C > Group D in KLK-7) and(Group A < Group B < Group C < Group D in E-cad). The weight and volume, and KLK7 and E-cad contents of transplantation tumors in four groups were significant difference(P<0.05). Conclusion: Cisplatin implants can inhibit the growth of transplanted tumor tissue and down-regulated KLK7 expression and up-regulated E-cad expression of tumor-bearing mice with gastric 展开更多
关键词 GASTRIC cancer CISPLATIN implants Tissue kallikrein-7 E-cadherin
下载PDF
Porous metal implants: processing,properties, and challenges 被引量:8
16
作者 Amit Bandyopadhyay Indranath Mitra +2 位作者 Jose D Avila Mahadev Upadhyayula Susmita Bose 《International Journal of Extreme Manufacturing》 SCIE EI CAS CSCD 2023年第3期441-483,共43页
Porous and functionally graded materials have seen extensive applications in modern biomedical devices—allowing for improved site-specific performance;their appreciable mechanical,corrosive,and biocompatible properti... Porous and functionally graded materials have seen extensive applications in modern biomedical devices—allowing for improved site-specific performance;their appreciable mechanical,corrosive,and biocompatible properties are highly sought after for lightweight and high-strength load-bearing orthopedic and dental implants.Examples of such porous materials are metals,ceramics,and polymers.Although,easy to manufacture and lightweight,porous polymers do not inherently exhibit the required mechanical strength for hard tissue repair or replacement.Alternatively,porous ceramics are brittle and do not possess the required fatigue resistance.On the other hand,porous biocompatible metals have shown tailorable strength,fatigue resistance,and toughness.Thereby,a significant interest in investigating the manufacturing challenges of porous metals has taken place in recent years.Past research has shown that once the advantages of porous metallic structures in the orthopedic implant industry have been realized,their biological and biomechanical compatibility—with the host bone—has been followed up with extensive methodical research.Various manufacturing methods for porous or functionally graded metals are discussed and compared in this review,specifically,how the manufacturing process influences microstructure,graded composition,porosity,biocompatibility,and mechanical properties.Most of the studies discussed in this review are related to porous structures for bone implant applications;however,the understanding of these investigations may also be extended to other devices beyond the biomedical field. 展开更多
关键词 porous metals load-bearing implants 3d printing additive manufacturing mechanical properties biological properties
下载PDF
Impact of osteoporosis in dental implants:A systematic review 被引量:11
17
作者 Gabriela Giro Leandro Chambrone +6 位作者 Abrao Goldstein Jose Augusto Rodrigues Elton Zenóbio Magda Feres Luciene Cristina Figueiredo Alessandra Cassoni Jamil Awad Shibli 《World Journal of Orthopedics》 2015年第2期311-315,共5页
AIM: To assess the failure and bone-to-implant contact rate of dental implants placed on osteoporotic subjects. METHODS: Extensive examination strategies were created to classify studies for this systematic review. ME... AIM: To assess the failure and bone-to-implant contact rate of dental implants placed on osteoporotic subjects. METHODS: Extensive examination strategies were created to classify studies for this systematic review. MEDLINE(via Pub Med) and EMBASE database were examined for studies in English up to and including May 2014. The examination presented a combination of the MeS H words described as follow: "osteoporosis" or "osteopenia" or "estrogen deficiency" AND "implant" or "dental implant" or "osseointegration". Assessment of clinical and/or histological peri-implant conditions in osteoporosis subjects treated with titanium dental implants. The examination included a combination of the MeS H terms described as follow: "osteoporosis" or "osteopenia" or "estrogen deficiency" AND "implant" or "dental implant" or "osseointegration".RESULTS: Of 943 potentially eligible articles, 12 were included in the study. A total of 133 subjects with osteoporosis, 73 subjects diagnosed with osteopenia and 708 healthy subjects were assessed in this systematic review. In these subjects were installed 367, 205, 2981 dental implants in osteoporotic, osteopenic and healthy subjects, respectively. The failure rate of dental implant was 10.9% in osteoporotic subjects, 8.29% in osteopenic and 11.43% in healthy ones. Bone-to-implant contact obtained from retrieved implants ranged between 49.96% to 47.84%, for osteoporosis and non-osteoporotic subjects. CONCLUSION: Osteoporotic subjects presented higher rates of implant loss, however, there is a lower evidence to strengthen or refute the hypothesis that osteoporosis may have detrimental effects on bone healing. Consequently, final conclusions regarding the effect of osteoporosis in dental implant therapy cannot be made at this time. There are no randomized clinical trial accessible for evaluation and the retrospectivenature of the evaluated studies shall be taken in account when interpreting this study. 展开更多
关键词 Dental implants OSTEOPOROSIS FAILURES OSTEOPENIA OSSEOINTEGRATION
下载PDF
From oral formulations to drug-eluting implants:using 3D and 4D printing to develop drug delivery systems and personalized medicine 被引量:3
18
作者 Niels G.A.Willemen Margaretha A.J.Morsink +4 位作者 Devin Veerman Classius F.da Silva Juliana C.Cardoso Eliana B.Souto Patrícia Severino 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2022年第1期85-106,共22页
Since the start of the Precision Medicine Initiative by the United States of America in 2015,interest in personalized medicine has grown extensively.In short,personalized medicine is a term that describes medical trea... Since the start of the Precision Medicine Initiative by the United States of America in 2015,interest in personalized medicine has grown extensively.In short,personalized medicine is a term that describes medical treatment that is tuned to the individual.One possible way to realize personalized medicine is 3D printing.When using materials that can be tuned upon stimulation,4D printing is established.In recent years,many studies have been exploring a new field that combines 3D and 4D printing with therapeutics.This has resulted in many concepts of pharmaceutical devices and formulations that can be printed and,possibly,tailored to an individual.Moreover,the first 3D printed drug,Spritam®,has already found its way to the clinic.This review gives an overview of various 3D and 4D printing techniques and their applications in the pharmaceutical field as drug delivery systems and personalized medicine. 展开更多
关键词 Drug delivery systems 3D/4D printing Drug-eluting implants MICRONEEDLES Oral formulations
下载PDF
MUSIC AND COCHLEAR IMPLANTS 被引量:4
19
作者 Mao Yitao Xu Li 《Journal of Otology》 2013年第1期32-38,共7页
Currently, most people with modern multichannel cochlear implant systems can understand speech in qui-et environment very well. However, studies in recent decades reported a lack of satisfaction in music percep-tion w... Currently, most people with modern multichannel cochlear implant systems can understand speech in qui-et environment very well. However, studies in recent decades reported a lack of satisfaction in music percep-tion with cochlear implants. This article reviews the literature on music ability of cochlear implant users by presenting a systematic outline of the capabilities and limitations of cochlear implant recipients with regard to their music perception as well as production. The review also evaluates the similarities and differences be-tween electric hearing and acoustic hearing regarding music perception. We summarize the research results in terms of the individual components of music (e.g., rhythm, pitch, and timbre). Finally, we briefly intro-duce the vocal singing of prelingually-deafened children with cochlear implants as evaluated by acoustic measures. 展开更多
关键词 Music perception vocal singing cochlear implants
下载PDF
Calcium phosphate conversion technique:A versatile route to develop corrosion resistant hydroxyapatite coating over Mg/Mg alloys based implants 被引量:2
20
作者 G.S.Hikku C.Arthi +2 位作者 R.B.Jeen Robert K.Jeyasubramanian R.Murugesan 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2022年第7期1821-1845,共25页
Globally,vast research interest is emerging towards the development of biodegradable orthopedic implants as it overcomes the toxicity exerted by non-degradable implants when fixed in the human body for a longer period... Globally,vast research interest is emerging towards the development of biodegradable orthopedic implants as it overcomes the toxicity exerted by non-degradable implants when fixed in the human body for a longer period.In this context,magnesium(Mg)plays a major role in the production of biodegradable implants owing to their characteristic degradation nature under the influence of body fluids.Also,Mg is one of the essential nutrients required to perform various metabolic activities by the human cells,and therefore,the degraded Mg products will be readily absorbed by the nearby tissues.Nevertheless,the higher corrosion rate in the biological environment is the primary downside of using Mg implants that liberate H2gas resulting in the formation of cavities.Further,in certain cases,Mg undergoes complete degradation before the healing of damaged bone tissue and cannot serve the purpose of providing mechanical support.So,many studies have been focused on the development of different strategies to improve the corrosion-resistant behavior of Mg according to the requirement.In this regard,the present review focused on the limitations of using pure Mg and Mg alloys for the fabrication of medical implants and how the calcium phosphate conversion coating alters the corrosive tendency through the formation of hydroxyapatite protective films for enhanced performance in medical implant applications. 展开更多
关键词 Biodegradable implants MAGNESIUM Controlled corrosion ALLOYING HYDROXYAPATITE Calcium phosphate conversion coating
下载PDF
上一页 1 2 116 下一页 到第
使用帮助 返回顶部