期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Accuracy improvement of quantitative analysis of calorific value of coal by combining support vector machine and partial least square methods in laser-induced breakdown spectroscopy 被引量:2
1
作者 李雄威 杨阳 +2 位作者 李庚达 陈保卫 胡文森 《Plasma Science and Technology》 SCIE EI CAS CSCD 2020年第7期105-109,共5页
Laser-induced breakdown spectroscopy(LIBS) is a potential technology for online coal property analysis,but successful quantitative measurement of calorific value using LIBS suffers from relatively low accuracy caused ... Laser-induced breakdown spectroscopy(LIBS) is a potential technology for online coal property analysis,but successful quantitative measurement of calorific value using LIBS suffers from relatively low accuracy caused by the matrix effect.To solve this problem,the support vector machine(SVM) and the partial least square(PLS) were combined to increase the measurement accuracy of calorific value in this study.The combination model utilized SVM to classify coal samples into two groups according to their volatile matter contents to reduce the matrix effect,and then applied PLS to establish calibration models for each sample group respectively.The proposed model was applied to the measurement of calorific values of 53 coal samples,showing that the proposed model could greatly increase accuracy of the measurement of calorific values.Compared with the traditional PLS method,the coefficient of determination(R2) was improved from 0.93 to 0.97,the root-mean-square error of prediction was reduced from 1.68 MJ kg-1 to1.08 MJ kg-1,and the average relative error was decreased from 6.7% to 3.93%,showing an overall improvement. 展开更多
关键词 accuracy improvement calorific value COAL PLS SVM LIBS
下载PDF
Improving Accuracy of Estimating Two-Qubit States with Hedged Maximum Likelihood
2
作者 殷琪 项国勇 +1 位作者 李传锋 郭光灿 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第3期1-5,共5页
As a widely used reconstruction algorithm in quantum state tomography, maximum likelihood estimation tends to assign a rank-deficient matrix, which decreases estimation accuracy for certain quantum states. Fortunately... As a widely used reconstruction algorithm in quantum state tomography, maximum likelihood estimation tends to assign a rank-deficient matrix, which decreases estimation accuracy for certain quantum states. Fortunately, hedged maximum likelihood estimation (HMLE) [Phys. Rev. Lett. 105 (2010)200504] was proposed to avoid this problem. Here we study more details about this proposal in the two-qubit case and further improve its performance. We ameliorate the HMLE method by updating the hedging function based on the purity of the estimated state. Both performances of HMLE and ameliorated HMLE are demonstrated by numerical simulation and experimental implementation on the Werner states of polarization-entangled photons. 展开更多
关键词 MLE Improving accuracy of Estimating Two-Qubit States with Hedged Maximum Likelihood
下载PDF
Distance-Coefficient-Based Imaging Accuracy Improving Method Based on the Lamb Wave
3
作者 陈少杰 周邵萍 +2 位作者 李勇 项延训 戚敏新 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第4期55-59,共5页
An imaging accuracy improving method is established, within which a distance coefficient including location information between sparse array configuration and the location of defect is proposed to select higher signal... An imaging accuracy improving method is established, within which a distance coefficient including location information between sparse array configuration and the location of defect is proposed to select higher signal- to-noise ratio data from all experimental data and then to use these selected data for elliptical imaging. Tile relationships among imaging accuracy, distance coefficient and residual direct wave are investigated, and then the residual direct wave is introduced to make the engineering application more convenient. The effectiveness of the proposed method is evaluated experimentally by sparse transducer array of a rectangle, and the results reveal that selecting experimental data of smaller distance coefficient can effectively improve imaging accuracy. Moreover, the direct wave difference increases with the decrease of the distance coefficient, which implies that the imaging accuracy can be effectively improved by using the experimental data of the larger direct wave difference. 展开更多
关键词 Distance-Coefficient-Based Imaging accuracy Improving Method Based on the Lamb Wave
下载PDF
A Way to Improve the Key Recovery Accuracy Based on Dynamic Programming
4
作者 PENG Shuanghe ZHOU Qiaofeng LIU Peiyao 《Wuhan University Journal of Natural Sciences》 CAS CSCD 2018年第6期535-540,共6页
Key-recovery technology is often used by an adversary to attempt to recover the cryptographic key of an encryption scheme. The most obvious key-recovery attack is the exhaustive key-search attack. But modern ciphers o... Key-recovery technology is often used by an adversary to attempt to recover the cryptographic key of an encryption scheme. The most obvious key-recovery attack is the exhaustive key-search attack. But modern ciphers often have a key space of size 2128 or greater, making such attacks infeasible with current technology. Cache-based side channel attack is another way to get the cryptographic key of an encryption scheme, but there are random noises in side channel attack. In order to reduce random errors, it is advisable to repeat the key recovery process many times. This paper is focused on the way to improve the key recovery accuracy by dealing with the key sequences obtained from the repeated Cache-based side channel attacks. To get the real key, private key bits from side channel attack are collected firstly. And then the key sequences are aligned using sequence alignment algorithms based on dynamic programming. The provided method of key recovery is universal, which is not limited to any cryptographic algorithm. The experiment shows that the proposed method has a good performance and a high availability when the error rate of the collected key bit is within a reasonable range. 展开更多
关键词 key recovery dynamic programming SEQUENCEALIGNMENT improve accuracy information security
原文传递
Using single wavelength light to improve the synchronization accuracy of the White Rabbit system 被引量:3
5
作者 袁绪 王波 《Chinese Optics Letters》 SCIE EI CAS CSCD 2017年第10期61-65,共5页
We demonstrate a new synchronization method for the White Rabbit system. Signals are transmitted in a single mode fiber in both directions with the same light wavelength. Without the complex calibration process of the... We demonstrate a new synchronization method for the White Rabbit system. Signals are transmitted in a single mode fiber in both directions with the same light wavelength. Without the complex calibration process of the fiber asymmetry parameter, the new method reduces the effect of chromatic dispersion and improves the synchronization accuracy. The experiment achieves timing synchronization accuracy below 200 ps over 50 km fiber constructed by different companies' fiber spools. The proposed method would make White Rabbit technology immune to the chromatic dispersion of fiber links and can be applied to long distance synchronization. 展开更多
关键词 length MS Using single wavelength light to improve the synchronization accuracy of the White Rabbit system
原文传递
Calibration method to improve the accuracy of THz imaging and spectroscopy in reflection geometry 被引量:3
6
作者 Shuting Fan Edward P.J.Parrott +1 位作者 Benjamin S.Y.Ung Emma Pickwell-MacPherson 《Photonics Research》 SCIE EI 2016年第3期29-35,共7页
We introduce a novel method to accurately extract the optical parameters in terahertz reflection imaging. Our method builds on standard self-referencing methods using the reflected signal from the bottom of the imagin... We introduce a novel method to accurately extract the optical parameters in terahertz reflection imaging. Our method builds on standard self-referencing methods using the reflected signal from the bottom of the imaging window material to further compensate for time-dependent system fluctuations and position-dependent variation in the window thickness. Our proposed method not only improves the accuracy, but also simplifies the imaging procedure and reduces measurement times. 展开更多
关键词 Calibration method to improve the accuracy of THz imaging and spectroscopy in reflection geometry THZ
原文传递
A new simpler rotation/curvature correction method for Spalart-Allmaras turbulence model 被引量:8
7
作者 Zhang Qiang Yang Yong 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2013年第2期326-333,共8页
A new and much simpler rotation and curvature effects factor, which takes the form of Richardson number suggested by Hellsten originally for SST k-ω model, is presented for Spalart and Shur's rotation and curvature ... A new and much simpler rotation and curvature effects factor, which takes the form of Richardson number suggested by Hellsten originally for SST k-ω model, is presented for Spalart and Shur's rotation and curvature correction in the context of Spalart-Allmaras (SA) turbulence model. The new factor excludes the Lagrangian derivative of the strain rate tensor that exists in the SARC model, resulting in a simple, efficient and easy-to-implement approach for SA turbulence model (denoted as SARCM) to account for the effects of system rotation and curvature, techniquely. And then the SARCM is tested through turbulent curved wall flows: one is the flow over a zeropressure-gradient curved wall and the other is the channel flow in a duct with a U-turn. Predictions of the SARCM model are compared with experimental data and with the results obtained using original SA and SARC models. The numerical results show that SARCM can predict the rotation-curvature effects as accurately as SARC, but considerably more efficiently. Additionally, the accuracy of SARCM might strongly depend on the rotation-curvature model constants. Suggesting values for those constants are given, after some trials and errors. 展开更多
关键词 accuracy Computation Curvature improvement Robust Rotation Strain rate tensor Turbulence model
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部