Under complex grid conditions,the grid voltage usually has an imbalance,low order harmonics,and a small of DC bias.When the grid voltage contains low order harmonics and a small amount of DC bias component,the inverte...Under complex grid conditions,the grid voltage usually has an imbalance,low order harmonics,and a small of DC bias.When the grid voltage contains low order harmonics and a small amount of DC bias component,the inverter’s output current cannot meet the grid connection requirements,and there is a three-phase current imbalance in the control strategy of common VSG under unbalanced voltage.A theoretical analysis of non-ideal power grids is carried out,and a VSG control strategy under complex operating conditions is proposed.Firstly,the third-order generalized integrator(TOGI)is used to eliminate the influence of the DC component of grid voltage.An improved delay signal cancellation(DSC)method is proposed to control the balance current and power fluctuation under unbalanced voltage based on the method of common VSG positive and negative sequence separation,It also eliminates the harmonic of command current.Then,the improved quasi proportional resonant controller(QPR)cascaded PI is used to suppress the harmonic current further so that the harmonic content of grid-connected current can meet the grid-connected requirements and achieve the three-phase current balance.Finally,the proposed strategy is verified by simulation under the control objectives of the current balance,active power,and reactive power constant.展开更多
串联补偿装置会引发汽轮机组的次同步谐振(subsynchronous resonance,SSR)。提出了一种改进粒子群算法,并基于该算法利用静止无功补偿器(static var compensators,SVC)抑制SSR的原理,选取适当的测试量,设计了次同步阻尼控制器。将SVC的...串联补偿装置会引发汽轮机组的次同步谐振(subsynchronous resonance,SSR)。提出了一种改进粒子群算法,并基于该算法利用静止无功补偿器(static var compensators,SVC)抑制SSR的原理,选取适当的测试量,设计了次同步阻尼控制器。将SVC的控制器参数视为自适应参数,通过改进粒子群算法,以阻尼比为目标函数,计算出不同运行情况下的控制器参数,达到抑制SSR的目的。以南方电网墨红串补、砚崇串补子系统的仿真模型为例,验证了该阻尼控制器的有效性。展开更多
基金National Natural Science Foundation of China(61863023).
文摘Under complex grid conditions,the grid voltage usually has an imbalance,low order harmonics,and a small of DC bias.When the grid voltage contains low order harmonics and a small amount of DC bias component,the inverter’s output current cannot meet the grid connection requirements,and there is a three-phase current imbalance in the control strategy of common VSG under unbalanced voltage.A theoretical analysis of non-ideal power grids is carried out,and a VSG control strategy under complex operating conditions is proposed.Firstly,the third-order generalized integrator(TOGI)is used to eliminate the influence of the DC component of grid voltage.An improved delay signal cancellation(DSC)method is proposed to control the balance current and power fluctuation under unbalanced voltage based on the method of common VSG positive and negative sequence separation,It also eliminates the harmonic of command current.Then,the improved quasi proportional resonant controller(QPR)cascaded PI is used to suppress the harmonic current further so that the harmonic content of grid-connected current can meet the grid-connected requirements and achieve the three-phase current balance.Finally,the proposed strategy is verified by simulation under the control objectives of the current balance,active power,and reactive power constant.
文摘串联补偿装置会引发汽轮机组的次同步谐振(subsynchronous resonance,SSR)。提出了一种改进粒子群算法,并基于该算法利用静止无功补偿器(static var compensators,SVC)抑制SSR的原理,选取适当的测试量,设计了次同步阻尼控制器。将SVC的控制器参数视为自适应参数,通过改进粒子群算法,以阻尼比为目标函数,计算出不同运行情况下的控制器参数,达到抑制SSR的目的。以南方电网墨红串补、砚崇串补子系统的仿真模型为例,验证了该阻尼控制器的有效性。