期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
High-speed VUV spectroscopy for edge impurity line emission measurements in HL-2A tokamak 被引量:1
1
作者 郑典麟 张凯 +7 位作者 崔正英 孙平 董春凤 卢平 傅炳忠 刘泽田 石中兵 杨青巍 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第10期75-83,共9页
A 20 cm focal length normal incidence vacuum ultraviolet (VUV_20 cm) monochromator with a fast time response has been developed for measuring edge impurity line emission in the wavelength range of 300-2000 A on an H... A 20 cm focal length normal incidence vacuum ultraviolet (VUV_20 cm) monochromator with a fast time response has been developed for measuring edge impurity line emission in the wavelength range of 300-2000 A on an HL-2A tokamak. An aberration corrected concave holographic grating with 1200 grooves/mm is adopted in the monochromator, which provides a wavelength dispersion of 40 A mm-1. The aperture is f/4.5. A channel electron multiplier is used as a detector. The time resolution of the system is 17 μs. Wavelength calibration of the system has been done by using a hollow cathode light source in the laboratory with helium and argon gases. The obtained signals of helium and argon spectra are very strong since the inner surface of the monochromator vacuum chamber is blackened and the stray light level is then significantly reduced. The optical property of the system has been examined by scanning the width of the entrance and exit slits. The system is then installed at the mid-port of the HL-2A tokamak and typical line emissions from the HL-2A plasma are measured. Time behaviors of edge impurity line emissions are observed with the fast time response system in different plasma confinement regimes, especially in the H-mode discharges. The result shows that the VUV_20 cm system works very well to measure the edge impurity line emissions in the edge localized modes phase of H-mode discharges. 展开更多
关键词 VUV monochromator CEM detector wavelength calibration impurity line emission H-mode plasmas
下载PDF
Observation of the Two-Dimensional Distribution of Impurity Line Emissions Using a Space-Resolved EUV Spectrometer in LHD
2
作者 王二辉 S.MORITA +1 位作者 M.GOTO 董春凤 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第2期106-109,共4页
A space-resolved EUV spectrometer for measuring the one-dimensional distribution of impurity line emissions in Large Helical Device (LHD) has been upgraded to measure two- dimensional distributions of impurity line ... A space-resolved EUV spectrometer for measuring the one-dimensional distribution of impurity line emissions in Large Helical Device (LHD) has been upgraded to measure two- dimensional distributions of impurity line emissions with an extension of working wavelength range to 30-650% The two-dimensional measurement is performed by scanning the observation chord horizontally. A rectangular plasma region of 520 × 700 mm2 in vertical and horizontal sizes can be observed during a single horizontal scan. The horizontal scan requires a time duration of 5 s at least. The spatial resolution is 10 mm in the vertical direction when a spatial-resolution slit of 0.2 mm in width is adopted. Although a spatial resolution in the toroidal direction is 75 mm, it is a function of CCD exposure time and horizontal scanning speed. Two-dimensional distribution of EUV line emissions from several impurities has been successfully observed for the first time from steady discharges in LHD. In this paper two-dimensional distributions of He II (303.78A), C V (40.27A), C VI (33.73A) and Fe XX (132.85A) located at different radial positions are presented with simple analysis on the magnetic field structure of LHD. 展开更多
关键词 EUV spectrometer impurity line emission two-dimensional distribution
下载PDF
Line identification of extreme ultraviolet (EUV) spectra from low-Z impurity ions in EAST tokamak plasmas 被引量:1
3
作者 黎嫘 张凌 +15 位作者 许棕 Shigeru MORITA 程云鑫 张丰玲 张文敏 段艳敏 臧庆 王守信 戴舒宇 左桂忠 孙震 王亮 丁晓彬 钱金平 刘海庆 胡立群 《Plasma Science and Technology》 SCIE EI CAS CSCD 2021年第7期15-30,共16页
Extreme ultraviolet(EUV) spectra emitted from low-Z impurity ions in the wavelength range of10–500Å were observed in Experimental Advanced Superconducting Tokamak(EAST)discharges. Several spectral lines from K-a... Extreme ultraviolet(EUV) spectra emitted from low-Z impurity ions in the wavelength range of10–500Å were observed in Experimental Advanced Superconducting Tokamak(EAST)discharges. Several spectral lines from K-and L-shell partially ionized ions were successfully observed with sufficient spectral intensities and resolutions for helium, lithium, boron, carbon,oxygen, neon, silicon and argon using two fast-time-response EUV spectrometers of which the spectral intensities are absolutely calibrated based on the intensity comparison method between visible and EUV bremsstrahlung continua. The wavelength is carefully calibrated using wellknown spectra. The lithium, boron and silicon are individually introduced for the wall coating of the EAST vacuum vessel to suppress mainly the hydrogen and oxygen influxes from the vacuum wall, while the carbon and oxygen intrinsically exist in the plasma. The helium is frequently used as the working gas as well as the deuterium. The neon and argon are also often used for the radiation cooling of edge plasma to reduce the heat flux onto the divertor plate. The measured spectra were analyzed mainly based on the database of National Institute of Standards and Technology. As a result, spectral lines of He Ⅱ, Li Ⅱ–Ⅲ, B Ⅳ–Ⅴ, C Ⅲ–Ⅵ, O Ⅲ–Ⅷ, Ne Ⅱ–Ⅹ,Si Ⅴ–Ⅻ, and Ar Ⅹ–XVI are identified in EAST plasmas of which the central electron temperature and chord-averaged electron density range in Te0=0.6–2.8 keV and ne=(0.5–6.0)×1019 m-3, respectively. The wavelengths and transitions of EUV lines identified here are summarized and listed in a table for each impurity species as the database for EUV spectroscopy using fusion plasmas. 展开更多
关键词 line identification EUV spectroscopy EUV spectra impurity line emissions tokamak plasmas
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部