Based on the lightning monitoring data, automatic and routine weather station observation data in spring (March-May) of 2013 of Sichuan Province, the corresponding relationship between the spatial distribution and t...Based on the lightning monitoring data, automatic and routine weather station observation data in spring (March-May) of 2013 of Sichuan Province, the corresponding relationship between the spatial distribution and the different regions, and the characteristics of atmospheric circulation and evolution of influence the sys- tem were analyzed and summarized. The results show that: the lightning and thunderstorm showed great regional differences in the spring of 2013 in Sichuan Province and the thunderstorm activity period was not the same in different areas. Because of the change of atmospheric circulation, the influence system from March to May corresponding to the thunderstorms in Sichuan tended to be volatile, also.展开更多
A case series was used to evaluate the efficacy of halffluence photodynamic therapy(PDT) for chronic central serous chorioretinopathy(CSCR). Patients were treated with standard-dose verteporfin and half-fluence PD...A case series was used to evaluate the efficacy of halffluence photodynamic therapy(PDT) for chronic central serous chorioretinopathy(CSCR). Patients were treated with standard-dose verteporfin and half-fluence PDT. Totally 13 eyes from 11 patients were included. The mean patient age was 52.0 y. There was a mean reduction in central retinal thickness of 107.0 microns. Totally 7/13 eyes(53.8%) achieved resolution of subretinal fluid(SRF) on optical coherence tomography(OCT) scan after 1 treatment with PDT. Four eyes had further treatment with PDT; of these 1 eye achieved resolution of SRF. Seven of the 13 eyes(53.8%) achieved an improvement of more than 5 ETDRS letters. One patient experienced acute macula oedema 1 d post PDT treatment. These results support the hypothesis that half-fluence PDT can have a positive effect in chronic CSCR for a gain in visual acuity and reduction in sub-retinal fluid. Acute macula oedema is a rare but potential adverse effect of half-fluence PDT.展开更多
Integrating photoacoustic(PA)and ultrasound(US)into a handheld probe to perform P A/US dual-modal imaging has been widely studied over the past few years.However,optical fuence decreases quickly in deeper tissue due t...Integrating photoacoustic(PA)and ultrasound(US)into a handheld probe to perform P A/US dual-modal imaging has been widely studied over the past few years.However,optical fuence decreases quickly in deeper tissue due to light scattering and absorption,which would signifi-cantly affect the quantitative PA imaging.In this paper,we performed a fluence compensation for a PA imaging study of human breast.The comparison of P A/US image with and without optical fuence compensation demonstrated that the fuence compensation could effectively improve imaging quality for handheld probe.展开更多
The influences of SSD on the beam characteristics in the near held are investigated. Results snow that it the SSD parameters are increased, the laser intensity modulation increases while fluence modulation decreases, ...The influences of SSD on the beam characteristics in the near held are investigated. Results snow that it the SSD parameters are increased, the laser intensity modulation increases while fluence modulation decreases, which is attributed to the temporal and spatial variation of the SSD pulse phase. The variations of intensity and fluence modulations with the SSD parameters are given. The simulation results are presented along with a method for choosing appropriate SSD parameters according to the variations and the requirements of applications.展开更多
The problem of determining the in vivo dosimetry for patients undergoing radiation treatment has been an area of interest since the development of the field. More recent methods of measurement employ Electronic Portal...The problem of determining the in vivo dosimetry for patients undergoing radiation treatment has been an area of interest since the development of the field. More recent methods of measurement employ Electronic Portal Image Devices (EPID), or dosimeter arrays, for entrance or exit fluence determination. The more recent methods of in vivo dosimetry make use of detector arrays and reconstruction techniques to determine dose throughout the patient volume. One method uses an array of ion chambers located upstream of the patient. This requires a special hardware device and places an additional attenuator in the beam path, which may not be desirable. An alternative to this approach is to use the existing EPID, which is part of most modern linear accelerators, to image the patient using the treatment beam. Methods exist to deconvolve the detector function of the EPID using a series of weighted exponentials [1]. Additionally, this method has been extended to the deconvolution of the patient scatter in order to determine in vivo dosimetry. The method developed here intends to use EPID images and an iterative deconvolution algorithm to reconstruct the impinging primary fluence on the patient. This primary fluence may then be employed, using treatment time volumetric imaging, to determine dose through the entire patient volume. Presented in this paper is the initial discussion of the algorithm, and a theoretical evaluation of its efficacy using montecarlo derived virtual fluence measurements. The results presented here indicate an agreement of 1% dose difference within 95% the field area receiving 10% of the entrance fluence for a set of sample highly modulated fields. These results warrant continued investigation in applying this algorithm to clinical patient treatments.展开更多
Prescriptions for radiation therapy are given in terms of dose-volume constraints (DVCs). Solving the fluence map optimization (FMO) problem while satisfying DVCs often requires a tedious trial-and-error for selecting...Prescriptions for radiation therapy are given in terms of dose-volume constraints (DVCs). Solving the fluence map optimization (FMO) problem while satisfying DVCs often requires a tedious trial-and-error for selecting appropriate dose control parameters on various organs. In this paper, we propose an iterative approach to satisfy DVCs using a multi-objective linear programming (LP) model for solving beamlet intensities. This algorithm, starting from arbitrary initial parameter values, gradually updates the values through an iterative solution process toward optimal solution. This method finds appropriate parameter values through the trade-off between OAR sparing and target coverage to improve the solution. We compared the plan quality and the satisfaction of the DVCs by the proposed algorithm with two nonlinear approaches: a nonlinear FMO model solved by using the L-BFGS algorithm and another approach solved by a commercial treatment planning system (Eclipse 8.9). We retrospectively selected from our institutional database five patients with lung cancer and one patient with prostate cancer for this study. Numerical results show that our approach successfully improved target coverage to meet the DVCs, while trying to keep corresponding OAR DVCs satisfied. The LBFGS algorithm for solving the nonlinear FMO model successfully satisfied the DVCs in three out of five test cases. However, there is no recourse in the nonlinear FMO model for correcting unsatisfied DVCs other than manually changing some parameter values through trial and error to derive a solution that more closely meets the DVC requirements. The LP-based heuristic algorithm outperformed the current treatment planning system in terms of DVC satisfaction. A major strength of the LP-based heuristic approach is that it is not sensitive to the starting condition.展开更多
The mean sputter depth depends on the surface composition gradient during ion implantation.For the high fluence ion implantation into a Pt-Cu alloy, the surface composition gradient of Cu is so large that the differen...The mean sputter depth depends on the surface composition gradient during ion implantation.For the high fluence ion implantation into a Pt-Cu alloy, the surface composition gradient of Cu is so large that the difference in mean sputter depth between Pt and Cu, is significant. However, for the high fluence ion implantation into 10B-11B isotope mixture, the surface composition gradient of 10B is so small that the difference in mean sputter depth between 10B and 11B is insignificant.展开更多
AIM:To compare the efficacy of low-fluence photodynamic therapy(PDT) combinations in the treatment of age-related macular degeneration(AMD).· METHODS:Forty-five previously untreated eyes of 45 patients with exuda...AIM:To compare the efficacy of low-fluence photodynamic therapy(PDT) combinations in the treatment of age-related macular degeneration(AMD).· METHODS:Forty-five previously untreated eyes of 45 patients with exudative AMD whose best-corrected visual acuity(BCVA) was ≥0.3(Snellen) were enrolled.15 patients in Group I underwent low-fluence PDT(25J/cm2-300mW/cm2-83sec) and intravitreal pegaptanib combination,15 patients in Group II underwent PDT(50J/cm2-600mW/cm2-83sec) and intravitreal pegaptanib combination while,15 patients in Group III underwent intravitreal pegaptanib monotherapy.Complete ophthalmologic examinations were performed in pre and post treatment visits,and the results were statistically analised.A clinical activity score(CAS) was calculated by using changes in lesion size,amount of hemorrhage,staining pattern in FA and OCT measurement of intra/subretinal fluid.≤3 logMAR lines of decrease in BCVA and decrease in CAS were considered as successful treatment.· RESULTS:The mean age of 19 female(42.2%) and 26 male(57.8%) patients was(72.82±8.02) years.Mean follow-up was(13.93±5.87) months.Lesion type was occult in 28 eyes(62.2%).Treatment success rates according to BCVA assessments were 86.7%,80%,60% and mean BCVA decrease were 0.3,1.0,2.2 logMAR lines in Group I,II and III,respectively(P >0.05).According to the changes in central macular thickness and CAS,no difference was found among the study groups(P =0.850 and P =0.811,respectively).Patients treated with combination regimens had lower intravitreal injection frequencies(P =0.015).· CONCLUSION:Combination regimen with intravitreal pegaptanib and low-fluence PDT seems to be safe and effective in stabilizing the clinical activity and BCVA in exudative AMD.·展开更多
On the basis of analyzing the reliability of the organization’ management chain of the large and medium- sized project in the construction period, the paper studies the factors influencing the reliability of the orga...On the basis of analyzing the reliability of the organization’ management chain of the large and medium- sized project in the construction period, the paper studies the factors influencing the reliability of the organi-zation management chain, which, corresponding to four elements of management chain – “Management Loop”, “Management Link”, “Management Chain”, and “Management Network”, can be summarized as project main body, interface management, connection sequence and management model. The paper then re-searches on the specific influencing factors from the above-mentioned four aspects.展开更多
文摘Based on the lightning monitoring data, automatic and routine weather station observation data in spring (March-May) of 2013 of Sichuan Province, the corresponding relationship between the spatial distribution and the different regions, and the characteristics of atmospheric circulation and evolution of influence the sys- tem were analyzed and summarized. The results show that: the lightning and thunderstorm showed great regional differences in the spring of 2013 in Sichuan Province and the thunderstorm activity period was not the same in different areas. Because of the change of atmospheric circulation, the influence system from March to May corresponding to the thunderstorms in Sichuan tended to be volatile, also.
文摘A case series was used to evaluate the efficacy of halffluence photodynamic therapy(PDT) for chronic central serous chorioretinopathy(CSCR). Patients were treated with standard-dose verteporfin and half-fluence PDT. Totally 13 eyes from 11 patients were included. The mean patient age was 52.0 y. There was a mean reduction in central retinal thickness of 107.0 microns. Totally 7/13 eyes(53.8%) achieved resolution of subretinal fluid(SRF) on optical coherence tomography(OCT) scan after 1 treatment with PDT. Four eyes had further treatment with PDT; of these 1 eye achieved resolution of SRF. Seven of the 13 eyes(53.8%) achieved an improvement of more than 5 ETDRS letters. One patient experienced acute macula oedema 1 d post PDT treatment. These results support the hypothesis that half-fluence PDT can have a positive effect in chronic CSCR for a gain in visual acuity and reduction in sub-retinal fluid. Acute macula oedema is a rare but potential adverse effect of half-fluence PDT.
基金International S&T Cooperation Program of China(2015DFA30440)National Natural Science Foundation of China(81301268,81421004)+1 种基金Beijing Nova Program(Z131107000413063)The National Key Instrumentation Development Project(2013YQ030651)。
文摘Integrating photoacoustic(PA)and ultrasound(US)into a handheld probe to perform P A/US dual-modal imaging has been widely studied over the past few years.However,optical fuence decreases quickly in deeper tissue due to light scattering and absorption,which would signifi-cantly affect the quantitative PA imaging.In this paper,we performed a fluence compensation for a PA imaging study of human breast.The comparison of P A/US image with and without optical fuence compensation demonstrated that the fuence compensation could effectively improve imaging quality for handheld probe.
基金Project supported by the State Key Program of the National Natural Science Foundation of China (Grant No.61138005)the National Natural Science Foundation of China (Grant No.61008005)
文摘The influences of SSD on the beam characteristics in the near held are investigated. Results snow that it the SSD parameters are increased, the laser intensity modulation increases while fluence modulation decreases, which is attributed to the temporal and spatial variation of the SSD pulse phase. The variations of intensity and fluence modulations with the SSD parameters are given. The simulation results are presented along with a method for choosing appropriate SSD parameters according to the variations and the requirements of applications.
文摘The problem of determining the in vivo dosimetry for patients undergoing radiation treatment has been an area of interest since the development of the field. More recent methods of measurement employ Electronic Portal Image Devices (EPID), or dosimeter arrays, for entrance or exit fluence determination. The more recent methods of in vivo dosimetry make use of detector arrays and reconstruction techniques to determine dose throughout the patient volume. One method uses an array of ion chambers located upstream of the patient. This requires a special hardware device and places an additional attenuator in the beam path, which may not be desirable. An alternative to this approach is to use the existing EPID, which is part of most modern linear accelerators, to image the patient using the treatment beam. Methods exist to deconvolve the detector function of the EPID using a series of weighted exponentials [1]. Additionally, this method has been extended to the deconvolution of the patient scatter in order to determine in vivo dosimetry. The method developed here intends to use EPID images and an iterative deconvolution algorithm to reconstruct the impinging primary fluence on the patient. This primary fluence may then be employed, using treatment time volumetric imaging, to determine dose through the entire patient volume. Presented in this paper is the initial discussion of the algorithm, and a theoretical evaluation of its efficacy using montecarlo derived virtual fluence measurements. The results presented here indicate an agreement of 1% dose difference within 95% the field area receiving 10% of the entrance fluence for a set of sample highly modulated fields. These results warrant continued investigation in applying this algorithm to clinical patient treatments.
文摘Prescriptions for radiation therapy are given in terms of dose-volume constraints (DVCs). Solving the fluence map optimization (FMO) problem while satisfying DVCs often requires a tedious trial-and-error for selecting appropriate dose control parameters on various organs. In this paper, we propose an iterative approach to satisfy DVCs using a multi-objective linear programming (LP) model for solving beamlet intensities. This algorithm, starting from arbitrary initial parameter values, gradually updates the values through an iterative solution process toward optimal solution. This method finds appropriate parameter values through the trade-off between OAR sparing and target coverage to improve the solution. We compared the plan quality and the satisfaction of the DVCs by the proposed algorithm with two nonlinear approaches: a nonlinear FMO model solved by using the L-BFGS algorithm and another approach solved by a commercial treatment planning system (Eclipse 8.9). We retrospectively selected from our institutional database five patients with lung cancer and one patient with prostate cancer for this study. Numerical results show that our approach successfully improved target coverage to meet the DVCs, while trying to keep corresponding OAR DVCs satisfied. The LBFGS algorithm for solving the nonlinear FMO model successfully satisfied the DVCs in three out of five test cases. However, there is no recourse in the nonlinear FMO model for correcting unsatisfied DVCs other than manually changing some parameter values through trial and error to derive a solution that more closely meets the DVC requirements. The LP-based heuristic algorithm outperformed the current treatment planning system in terms of DVC satisfaction. A major strength of the LP-based heuristic approach is that it is not sensitive to the starting condition.
文摘The mean sputter depth depends on the surface composition gradient during ion implantation.For the high fluence ion implantation into a Pt-Cu alloy, the surface composition gradient of Cu is so large that the difference in mean sputter depth between Pt and Cu, is significant. However, for the high fluence ion implantation into 10B-11B isotope mixture, the surface composition gradient of 10B is so small that the difference in mean sputter depth between 10B and 11B is insignificant.
文摘AIM:To compare the efficacy of low-fluence photodynamic therapy(PDT) combinations in the treatment of age-related macular degeneration(AMD).· METHODS:Forty-five previously untreated eyes of 45 patients with exudative AMD whose best-corrected visual acuity(BCVA) was ≥0.3(Snellen) were enrolled.15 patients in Group I underwent low-fluence PDT(25J/cm2-300mW/cm2-83sec) and intravitreal pegaptanib combination,15 patients in Group II underwent PDT(50J/cm2-600mW/cm2-83sec) and intravitreal pegaptanib combination while,15 patients in Group III underwent intravitreal pegaptanib monotherapy.Complete ophthalmologic examinations were performed in pre and post treatment visits,and the results were statistically analised.A clinical activity score(CAS) was calculated by using changes in lesion size,amount of hemorrhage,staining pattern in FA and OCT measurement of intra/subretinal fluid.≤3 logMAR lines of decrease in BCVA and decrease in CAS were considered as successful treatment.· RESULTS:The mean age of 19 female(42.2%) and 26 male(57.8%) patients was(72.82±8.02) years.Mean follow-up was(13.93±5.87) months.Lesion type was occult in 28 eyes(62.2%).Treatment success rates according to BCVA assessments were 86.7%,80%,60% and mean BCVA decrease were 0.3,1.0,2.2 logMAR lines in Group I,II and III,respectively(P >0.05).According to the changes in central macular thickness and CAS,no difference was found among the study groups(P =0.850 and P =0.811,respectively).Patients treated with combination regimens had lower intravitreal injection frequencies(P =0.015).· CONCLUSION:Combination regimen with intravitreal pegaptanib and low-fluence PDT seems to be safe and effective in stabilizing the clinical activity and BCVA in exudative AMD.·
文摘On the basis of analyzing the reliability of the organization’ management chain of the large and medium- sized project in the construction period, the paper studies the factors influencing the reliability of the organi-zation management chain, which, corresponding to four elements of management chain – “Management Loop”, “Management Link”, “Management Chain”, and “Management Network”, can be summarized as project main body, interface management, connection sequence and management model. The paper then re-searches on the specific influencing factors from the above-mentioned four aspects.