期刊文献+
共找到17,170篇文章
< 1 2 250 >
每页显示 20 50 100
Operating Parameters of the District Heating Substation Cooperating With the Installation of Technological Air Conditioning With High Efficiency of Heat Recovery
1
作者 Żarski Kazimierz Kryża Mariusz 《Chinese Business Review》 2024年第1期1-12,共12页
The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchange... The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchangers with high efficiency of heat recovery.Attention was paid to the correct selection of heat exchangers for the heat output balance depending on the heat recovery protection algorithms against a drop in the temperature of the heat transfer surface below 0℃.Critical parameters were determined in Polish climatic conditions,at which the operation of the heat recovery exchanger in the air conditioning system is switched off or limited.It has been proven that the proper functioning of the district heating substation cooperating with the installation of air conditioning with high heat recovery efficiency requires the use of two heat exchangers with different characteristics,equipped with properly selected temperature control systems.The optimal model of cooperation between the technological air conditioning system and the heating substation was also indicated. 展开更多
关键词 ventilation of operating theatre air conditioning flow control in heating circuit
下载PDF
Localized Theoretical Analysis of Thermal Performance of Individually Finned Heat Pipe Heat Exchanger for Air Conditioning with Freon R404A as Working Fluid
2
作者 Élcio Nogueira 《Journal of Materials Science and Chemical Engineering》 2023年第8期61-85,共17页
This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat... This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat exchangers with individually finned heat pipes. The fundamental parameters used for performance analysis were the number of fins per heat pipe, the number of heat pipes, the inlet temperatures, and the flow rates of hot and cold fluids. The heat exchanger under analysis uses Freon 404A as a working fluid in an air conditioning system for cooling in the Evaporator and energy recovery in the Condenser. The theoretical model is localized and applied individually to the Evaporator, Condenser, and heat exchanger regions. The results obtained through the simulation are compared with experimental results that use a global approach for the heat exchanger. The thermal quantities obtained through the theoretical model in the mentioned regions are air velocity, Nusselt number, thermal effectiveness, heat transfer rate, and outlet temperature. The comparisons made with global experimental results are in excellent agreement, demonstrating that the localized theoretical approach developed is consistent and can be used as a comprehensive analysis tool for heat exchangers using heat pipes. 展开更多
关键词 Individually Finned Heat Pipe Heat Exchanger Thermal Efficiency Thermal Effectiveness air conditioning Freon R404A
下载PDF
Localized Theoretical Analysis of Thermal Performance of Individually Finned Heat Pipe Heat Exchanger for Air Conditioning with Freon R404A as Working Fluid
3
作者 Élcio Nogueira 《Journal of Modern Physics》 2023年第8期61-85,共6页
This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat... This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat exchangers with individually finned heat pipes. The fundamental parameters used for performance analysis were the number of fins per heat pipe, the number of heat pipes, the inlet temperatures, and the flow rates of hot and cold fluids. The heat exchanger under analysis uses Freon 404A as a working fluid in an air conditioning system for cooling in the Evaporator and energy recovery in the Condenser. The theoretical model is localized and applied individually to the Evaporator, Condenser, and heat exchanger regions. The results obtained through the simulation are compared with experimental results that use a global approach for the heat exchanger. The thermal quantities obtained through the theoretical model in the mentioned regions are air velocity, Nusselt number, thermal effectiveness, heat transfer rate, and outlet temperature. The comparisons made with global experimental results are in excellent agreement, demonstrating that the localized theoretical approach developed is consistent and can be used as a comprehensive analysis tool for heat exchangers using heat pipes. 展开更多
关键词 Individually Finned Heat Pipe Heat Exchanger Thermal Efficiency Thermal Effectiveness air conditioning Freon R404A
下载PDF
Analyses of an air conditioning system with entropy generation minimization and entransy theory 被引量:3
4
作者 吴艳秋 蔡黎 吴鸿娟 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第6期130-136,共7页
In this paper,based on the generalized heat transfer law,an air conditioning system is analyzed with the entropy generation minimization and the entransy theory.Taking the coefficient of performance(denoted as COP) ... In this paper,based on the generalized heat transfer law,an air conditioning system is analyzed with the entropy generation minimization and the entransy theory.Taking the coefficient of performance(denoted as COP) and heat flow rate Qout which is released into the room as the optimization objectives,we discuss the applicabilities of the entropy generation minimization and entransy theory to the optimizations.Five numerical cases are presented.Combining the numerical results and theoretical analyses,we can conclude that the optimization applicabilities of the two theories are conditional.If Qout is the optimization objective,larger entransy increase rate always leads to larger Qout,while smaller entropy generation rate does not.If we take COP as the optimization objective,neither the entropy generation minimization nor the concept of entransy increase is always applicable.Furthermore,we find that the concept of entransy dissipation is not applicable for the discussed cases. 展开更多
关键词 entropy generation entransy increase entransy dissipation optimization analyses finite time thermodynamics air conditioning system
下载PDF
Air-condition process for scalable fabrication of CdS/ZnS 1D/2D heterojunctions toward efficient and stable photocatalytic hydrogen production
5
作者 Dongdong Zhang Jie Teng +7 位作者 Hongli Yang Zhi Fang Kai Song Lin Wang Huilin Hou Xianlu Lu Chris RBowen Weiyou Yang 《Carbon Energy》 SCIE CSCD 2023年第7期1-14,共14页
We report the scalable fabrication of CdS/ZnS 1D/2D heterojunctions under ambient air conditions(i.e.,room temperature and atmospheric pressure)in which ZnS nanoparticles are anchored on the surface of CdS nanosheets.... We report the scalable fabrication of CdS/ZnS 1D/2D heterojunctions under ambient air conditions(i.e.,room temperature and atmospheric pressure)in which ZnS nanoparticles are anchored on the surface of CdS nanosheets.The as-formed heterojunctions exhibit a significantly enhanced photocatalytic H_(2) evolution rate of 14.02 mmol h^(-1) g^(-1) when irradiated with visible light,which is~10 and 85 times higher than those of pristine CdS nanosheets and CdS nanoparticles,respectively,and superior to most of the CdS-based photocatalysts reported to date.Furthermore,they provide robust photocatalytic performance with demonstratable stability over 58 h,indicating their potential for practical applications.The formation of 1D/2D heterojunctions not only provides improved exposed active sites that respond to illumination but also provides a rapid pathway to generate photogenerated carriers for efficient separation and transfer through the matrix of single-crystalline CdS nanosheets.In addition,first-principles simulations demonstrate that the existence of rich Zn vacancies increases the energy level of the ZnS valence band maximum to construct type-II and Z-scheme mixed heterojunctions,which plays a critical role in suppressing the recombination of carriers with limited photocorrosion of CdS to enhance photocatalytic behavior. 展开更多
关键词 air condition CdS HETEROJUNCTIONS photocatalytic hydrogen production ZNS
下载PDF
Modelling of a Two-Phase Thermosyphon Loop for Passive Air-Conditioning of a House in Hot and Dry Climate Countries 被引量:1
6
作者 Abdoulaye 1 Diallo Xavier Chesneau +1 位作者 Idrissa Diaby Djanfar El-Maktoume 《Energy and Power Engineering》 2021年第6期243-260,共18页
The two-phase thermosyphon loop is an efficient solution for space cooling. This paper presents the simulation results of numerical studies on the heat transfer and thermal performance of a two-phase thermosiphon loop... The two-phase thermosyphon loop is an efficient solution for space cooling. This paper presents the simulation results of numerical studies on the heat transfer and thermal performance of a two-phase thermosiphon loop for passive air-conditioning of a house. The fluid considered in this study is methanol, which is compatible with copper and is environmentally friendly. These numerical results show that the temperature at the evaporator wall drops from 23<span style="color:#111111;font-family:Roboto, sans-serif;font-size:16px;white-space:normal;background-color:#FFFFFF;">°</span>C to 13<span style="color:#111111;font-family:Roboto, sans-serif;font-size:16px;white-space:normal;background-color:#FFFFFF;">°</span>C and increases at the condenser. The solar flux density has a strong influence on the condenser temperature. The mass flow rates and masses at the evaporator and condenser increase with temperature. The variation of evaporating and condensing temperature affects the performance of the system. For a constant evaporating and condensing temperature of 2<span style="color:#111111;font-family:Roboto, sans-serif;font-size:16px;white-space:normal;background-color:#FFFFFF;">°</span>C and 29<span style="color:#111111;font-family:Roboto, sans-serif;font-size:16px;white-space:normal;background-color:#FFFFFF;">°</span>C, the COP is 0.77 and 0.84 respectively. With these results, the use of the two-phase thermosyphon loop in air conditioning is possible to obtain a thermal comfort of the occupants acceptable by the standards but with a large exchange surface of the evaporator. 展开更多
关键词 Two-Phase Thermosiphon Loop MODELLING Passive air conditioning Thermal Performance
下载PDF
Effect of Two Kinds of Similarity Factors on Principal Component Analysis Fault Detection in Air Conditioning Systems 被引量:2
7
作者 杨学宾 何如如 +1 位作者 王吉 罗雯军 《Journal of Donghua University(English Edition)》 CAS 2021年第3期245-251,共7页
Screening similar historical fault-free candidate data would greatly affect the effectiveness of fault detection results based on principal component analysis(PCA).In order to find out the candidate data,this study co... Screening similar historical fault-free candidate data would greatly affect the effectiveness of fault detection results based on principal component analysis(PCA).In order to find out the candidate data,this study compares unweighted and weighted similarity factors(SFs),which measure the similarity of the principal component subspace corresponding to the first k main components of two datasets.The fault detection employs the principal component subspace corresponding to the current measured data and the historical fault-free data.From the historical fault-free database,the load parameters are employed to locate the candidate data similar to the current operating data.Fault detection method for air conditioning systems is based on principal component.The results show that the weighted principal component SF can improve the effects of the fault-free detection and the fault detection.Compared with the unweighted SF,the average fault-free detection rate of the weighted SF is 17.33%higher than that of the unweighted,and the average fault detection rate is 7.51%higher than unweighted. 展开更多
关键词 similarity factor(SF) fault detection principal component analysis(PCA) historical candidate data air conditioning system
下载PDF
Influence of Three Sizes of Sliding Windows on Principle Component Analysis Fault Detection of Air Conditioning Systems 被引量:1
8
作者 杨学宾 马艳云 +2 位作者 何如如 王吉 罗雯军 《Journal of Donghua University(English Edition)》 CAS 2022年第1期72-78,共7页
Principal component analysis(PCA)has been already employed for fault detection of air conditioning systems.The sliding window,which is composed of some parameters satisfying with thermal load balance,can select the ta... Principal component analysis(PCA)has been already employed for fault detection of air conditioning systems.The sliding window,which is composed of some parameters satisfying with thermal load balance,can select the target historical fault-free reference data as the template which is similar to the current snapshot data.The size of sliding window is usually given according to empirical values,while the influence of different sizes of sliding windows on fault detection of an air conditioning system is not further studied.The air conditioning system is a dynamic response process,and the operating parameters change with the change of the load,while the response of the controller is delayed.In a variable air volume(VAV)air conditioning system controlled by the total air volume method,in order to ensure sufficient response time,30 data points are selected first,and then their multiples are selected.Three different sizes of sliding windows with 30,60 and 90 data points are applied to compare the fault detection effect in this paper.The results show that if the size of the sliding window is 60 data points,the average fault-free detection ratio is 80.17%in fault-free testing days,and the average fault detection ratio is 88.47%in faulty testing days. 展开更多
关键词 sliding window principal component analysis(PCA) fault detection sensitivity analysis air conditioning system
下载PDF
Energy Efficient Air Conditioning System Using Geothermal Cooling-Solar Heating in Gujarat, India 被引量:1
9
作者 Sneha Shahare T. Harinarayana 《Journal of Power and Energy Engineering》 2016年第1期57-71,共15页
It is well known that one unit of electrical energy saved is equal to more than two units produced. One way of economizing the power is utilization of energy efficient systems at all locations. In the present study, t... It is well known that one unit of electrical energy saved is equal to more than two units produced. One way of economizing the power is utilization of energy efficient systems at all locations. In the present study, the air conditioning system is analysed and an innovative way is suggested. We use natural low temperature of shallow sub surface (1 - 3 m) of the earth—geothermal cooling system. It is known that majority of the households and the apartment complexes in India have two tanks for water storage. One is the underground water sump and the other is the overhead water tank. In our study, we use these two water storage systems for space cooling during summer and also for heating during winter. The main aim of our paper is air-conditioning of the space in an economic way to save electricity. It is based on a simple idea of transferring the low temperature from underground water sump to the room in the house using water as a mode of transport. Since India is a tropical country located at low latitude, most of the year, the air temperature is high and demands space cooling. However, for a couple of months during severe winter months (Dec.-Jan.) at Ahmedabad, heating of the space is required. For heating the space, we suggest to use the well-known solar water heater. Effective use of heat exchanger is shown through computation, modelling schemes and lab experiment. We recommend geothermal cooling for 10 months in a year and solar hot water system during 2 months of winter. It is observed that the ambient air temperature of 35°C - 40°C in the room can be brought down to 26°C without much consumption of electricity. In a similar manner, the room temperature at night (13°C) during winter in Ahmedabad can be increased to 27°C through circulation of water from solar water heater in the heat exchanger. 展开更多
关键词 Energy Efficiency Geothermal Cooling air conditioning CFD Thermal Comfort Earth Water Heat Exchanger
下载PDF
Impact of summer office set air-conditioning temperature on energy consumption and thermal comfort 被引量:3
10
作者 刘红 马小磊 高亚峰 《Journal of Central South University》 SCIE EI CAS 2009年第S1期6-11,共6页
To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three... To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three similar offices at temperatures of 24,26 and 28 ℃ respectively. A thermal comfort questionnaire survey was conducted. It is demonstrated that air-conditioner energy consumption at the set temperature of 28 ℃ is 113% and 271% lower than at 26 ℃ and 24 ℃,respectively. A linear relationship exists between air-conditioner energy consumption and the indoor and outdoor temperature difference. When comfortably dressed,over 80% of research participants accept the set temperature of 28 ℃. The regression analysis leads to a neutral temperature of 26.2 ℃ and an acceptable temperature of 28.2 ℃ for over 80% of the research participants subjects,indicating that the current 26 ℃ set temperature for offices in summer,required by Chinese General Office of the State Council,can be increased to 28 ℃. Moreover,analysis of predicted mean vote(PMV) index shows that a set temperature of 27 ℃,not 26 ℃,is sufficiently comfortable for office staff wearing long-sleeve shirts,long pants and leather shoes. 展开更多
关键词 air-conditioning TEMPERATURE thermal COMFORT air-conditIONER energy consumption NEUTRAL TEMPERATURE acceptable TEMPERATURE
下载PDF
Experimental Study of Air Conditioning Unit of Evaporative Cooling Assisted Mechanical Refrigeration 被引量:3
11
作者 HUANG Xiang,XU Fang-cheng,WU Jun-mei(Xi’an polytechnic University,Xi’an,Shaanxi 710048,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期106-110,共5页
The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analy... The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analyzed.The test shows that making full use of the evaporative cooling "free cooling" in Spring and Autumn seasons can fully meet the requirements of air-conditioned comfort through the switch of the function in different seasons.Taking into account the evaporative cooling fan and pump energy consumption,compared with the traditional mechanical refrigeration system,more than 80 percent of energy can be saved,and the energy efficiency ratio of the Unit(EER)is as high as 7.63.Using the two stages of indirect evaporative cooling to pre-cool the new wind in summer,under the conditions of the same air supply temperature requirements,0.83 kg/s chilled water saved can be equivalent to the traditional mechanical refrigeration system,and when the new wind ratio up to 50 percent,more than 10 percent load was reduced in mechanical refrigeration system.The overall EER increased about 35 percent. 展开更多
关键词 EVAPORATIVE COOLING mechanical REFRIGERATION air-conditioning unit EER
下载PDF
Genetic Optimization Algorithm of PID Decoupling Control for VAV Air-Conditioning System 被引量:3
12
作者 王江江 安大伟 +1 位作者 张春发 荆有印 《Transactions of Tianjin University》 EI CAS 2009年第4期308-314,共7页
Variable-air-volume (VAV) air-conditioning system is a multi-variable system and has multi coupling control loops. While all of the control loops are working together, they interfere and influence each other. A multiv... Variable-air-volume (VAV) air-conditioning system is a multi-variable system and has multi coupling control loops. While all of the control loops are working together, they interfere and influence each other. A multivariable decoupling PID controller is designed for VAV air-conditioning system. Diagonal matrix decoupling method is employed to eliminate the coupling between the loop of supply air temperature and that of thermal-space air temperature. The PID controller parameters are optimized by means of an improved genetic algorithm in floating point representations to obtain better performance. The population in the improved genetic algorithm mutates before crossover, which is helpful for the convergence. Additionally the micro mutation algorithm is proposed and applied to improve the convergence during the later evolution. To search the best parameters, the optimized parameters ranges should be amplified 10 times the initial ideal parameters. The simulation and experiment results show that the decoupling control system is effective and feasible. The method can overcome the strong coupling feature of the system and has shorter governing time and less over-shoot than non-optimization PID control. 展开更多
关键词 变风量空调系统 遗传优化算法 PID控制器 解耦控制系统 浮点遗传算法 控制回路 送风温度 多变量系统
下载PDF
Entropy Assessment on Environmental Influence of Condense Heat in Recovery System in Air-Conditioning Refrigerating Machine 被引量:2
13
作者 TANG Wen-wu1,2,WANG Han-qing1,2(1.School of Energy Science and Engineering,Central South University,Changsha,Hunan 410083,China 2.School of Civil Engineering,Hunan University of Technology,Zhuzhou,Hunan 412008,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期96-101,共6页
This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an ... This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an emission entropy from the condense heat recovery system in the air conditioning refrigerating machine were introduced.For the evaluation of the entropies,we developed a new algorithm for the parameter identification,called the composite influence coefficient,based on the Least Squares Support Vector Machine method.By simulation,the numerical experiments shows that the Least Squares Support Vector Machine method is one of the powerful methods for the parameter identification to compute the damage entropy of the condense heat,with the largest training error being-0.025(the relative error being-3.56%),and the biggest test error being 0.015(the relative error being 2.5%). 展开更多
关键词 air-conditioning refrigerating MACHINE condense HEAT ENTROPY evaluation LS-SVM
下载PDF
System design and analysis of the trans-critical carbon-dioxide automotive air-conditioning system 被引量:2
14
作者 穆景阳 陈江平 陈芝久 《Journal of Zhejiang University Science》 EI CSCD 2003年第3期305-308,共4页
As an environmentally harmless and feasible alternate refrigerant, CO2 has attracted worldwide attention, especially in the area of automobile air-conditioning (AAC). The thermal property of CO2 and its trans-eritical... As an environmentally harmless and feasible alternate refrigerant, CO2 has attracted worldwide attention, especially in the area of automobile air-conditioning (AAC). The thermal property of CO2 and its trans-eritical refrigeration cycle is very different from that of the traditional CFC or HCFC system. The detailed process of CO2 system thermal cycle design and optimization is described in this paper. System prototype and performance test bench were developed to analyze the performance of the CO2 AAC system. 展开更多
关键词 自动空气调节系统 系统设计 二氧化碳 制冷剂 横向临界循环制冷
下载PDF
A Case Study:Distribution of Bacterial and Fungal Aerosols in Air-Conditioning Systems in Shaanxi History Museum
15
作者 LI An-gui,HOU Juan-juan,JI Zeng-bao,ZHU Xiao-bin(School of Environmental & Municipal Engineering,Xi’an University of Architecture and Technology,Xi’an,Shaanxi 710055,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期10-14,共5页
In order to investigate the bacteria and fungi aerosol characteristic distribution in HVAC-system and its components at Shaanxi History Museum.Measurements were performed to probe the bacteria and fungi aerosol in HVA... In order to investigate the bacteria and fungi aerosol characteristic distribution in HVAC-system and its components at Shaanxi History Museum.Measurements were performed to probe the bacteria and fungi aerosol in HVAC systems,located at Xi'an city,China.The results showed that there was fungi growth inside the ventilation ducts,fungi contamination was worse than bacteria,and both of them were distributed into occupied space with the air supply ducts.The dominating genera of fungi was found to be Penicillium spp.and Aspergillus spp.,which was respectively 46.1% and 20.7% in settling fungi,and the dominating genera of fungi in dust were Cladosporium spp.and Penicillium spp.,which was 41.8% and 30.1% respectively.It suggests that available measures to improve and control the performance of HVAC-systems such as the maintenance,management and cleaning should be taken to prevent this pollution and to develop strategies to keep this pollution away. 展开更多
关键词 central air conditioning MICROBE bacteria FUNGI contamination field experiment
下载PDF
Method for acquiring part load distribution coefficient of air conditioning system
16
作者 丁勇 李百战 谭颖 《Journal of Central South University》 SCIE EI CAS 2009年第S1期95-99,共5页
This paper presents a method to acquire runtime distribution ratio of building air conditioning system under part load condition (part load coefficient of system) through practical energy consumption data. By utilizin... This paper presents a method to acquire runtime distribution ratio of building air conditioning system under part load condition (part load coefficient of system) through practical energy consumption data. By utilizing monthly energy consumption data of the entire year as the analysis object,this paper identifies data distribution,verifies distribution characteristics and analyzes distribution probability density for the issue of running time distribution ratio of air conditioning system in part load zones in the whole operation period,thus providing a basic calculation basis for an overall analysis of energy efficiency of air conditioning system. In view of the general survey of public building energy consumption carried by the government of Chongqing,this paper takes the governmental office building as an example,the part load ratio coefficient corresponding to practical running of air conditioning system of governmental office building in Chongqing is obtained by utilizing the above probability analysis and the solving method of probability density function. By utilizing the ratio coefficient obtained using this method,the part load coefficient with any running ratio of air conditioning system can be obtained according to the requirement of analysis,which can be used in any load ratio for analyzing running energy efficiency of air conditioning system. 展开更多
关键词 air conditioning SYSTEM MONTHLY energy CONSUMPTION PROBABILITY density distribution part load COEFFICIENT of SYSTEM
下载PDF
Applicability of sewage heat pump air-conditioning system
17
作者 陈金华 刘猛 +2 位作者 刘勇 靳鸣 陈洁 《Journal of Central South University》 SCIE EI CAS 2009年第S1期183-187,共5页
A sewage heat pump system and its application based on a project in Chongqing,China,were discussed. Based on the sewage conditions,a feasibility analysis of the sewage heat pump air conditioning system was conducted. ... A sewage heat pump system and its application based on a project in Chongqing,China,were discussed. Based on the sewage conditions,a feasibility analysis of the sewage heat pump air conditioning system was conducted. The theoretical and quantitative calculations indicate that sewage flux in the city sewage main pipe in the project can satisfy heat exchange requirements,and taking water from the pipes has relatively small influence on the pipe net in summer and winter. The sewage heat pump air-conditioning system can save 21.5% operating cost in one year,which is energy efficient and environmentally friendly. 展开更多
关键词 SEWAGE heat PUMP air conditioning system NUMERICAL calculation energy efficiency environmental FRIENDLINESS
下载PDF
Evaporative Condensers in Comfortable Air Conditioning System
18
作者 YIN Ying-de1,ZHU Dong-sheng1,DU Gui-mei2,LI Yuan-xi1,SUN He-jing1,LIU Qing-ming1(1.Key Lab of Enhancement Heat Transfer and Energy Conservation,the Ministry of Education,South China University of Technology,Guangzhou,Guangdong 510641,China 2.College of Civil Engineering,Hunan University,Changsha,Hunan 410082,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期136-140,共5页
The operating theory of an evaporative condenser was expatiated.The difference between an evaporative condensing refrigeration system and a general refrigeration system was analyzed.Compared with the air-cooled and th... The operating theory of an evaporative condenser was expatiated.The difference between an evaporative condensing refrigeration system and a general refrigeration system was analyzed.Compared with the air-cooled and the water-cooled,the virtues of energy-conservation and water-conservation of evaporative condensers were analyzed.Some questions existing in the application of evaporative condensers were pointed out,the corresponding solving methods were analyzed accordingly,and the development trend of evaporative condensing technique in mechanical refrigeration system field and the applied foreground of evaporative condensers in comfortable air conditioning were prospected. 展开更多
关键词 EVAPORATIVE CONDENSERS EVAPORATIVE condensing REFRIGERATION SYSTEM general REFRIGERATION SYSTEM comfortable air conditioning SYSTEM
下载PDF
Numerical Analysis on Ventilating and Air Conditioning Scheme of Shenyang Subway Station 被引量:1
19
作者 李伟 那艳玲 《Transactions of Tianjin University》 EI CAS 2007年第2期147-151,共5页
Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and opera... Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and operating status. In this paper, a physical and mathematical model is built according to the design of Shenyang subway (line 1), the boundary conditions of the model are defined by the design and experiments, the numerical analysis of ventilating scheme and air conditioning scheme is introduced individually, and the temperature field and air flow field of the two schemes are compared, so that the feasibility of using a ventilating scheme in subway of northeast cities is discussed. Considering comfort and economy, it can be concluded that mechanical ventilation is feasible in subway of northeast cities because the air temperature there is not very high in summer. 展开更多
关键词 沈阳 地铁车站 通风换气 空气调节方案 温度场 气流场
下载PDF
AIR CONDITIONING REFRIGERANTS AND OZONE PROTECTION
20
作者 周亚素 华征宇 《Journal of China Textile University(English Edition)》 EI CAS 1995年第1期56-60,共5页
Until recently, CFC-11 and CFC-12 were the most widely used refrigerant gases in air conditioning systems. Environmental agencies around the world, however, have specifical concern for these gases as a direct cause of... Until recently, CFC-11 and CFC-12 were the most widely used refrigerant gases in air conditioning systems. Environmental agencies around the world, however, have specifical concern for these gases as a direct cause of the depletion of the Earth’s ozone layer. Consequently, the world’s industrial nations are taking concerted action to decrease the use of CFCs, calling for attention of the engineers and designers involved in the manufacture and application of refrigeration systems for air conditioning. This paper analyses the available alternatives of CFCs in the industry and examines the problem found in process application. 展开更多
关键词 air conditioning refeigerant CHLOROFLUOROCARBONS OZONE layer ALTERNATIVE refrigerant.
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部