The in-situ instrumentation technique for measuring mercury and itsspeciation downstream a utility 100 MW pulverized coal (PC) fired boiler system was developed andconducted by the use of the Ontario hydro method (OHM...The in-situ instrumentation technique for measuring mercury and itsspeciation downstream a utility 100 MW pulverized coal (PC) fired boiler system was developed andconducted by the use of the Ontario hydro method (OHM) consistent with American standard test methodtogether with the semi-continuous emissions monitoring (SCEM) system as well as a mobile laboratoryfor mercury monitoring. The mercury and its speciation concentrations including participate mercuryat three locations of before air preheater, before electrostatic precipitator (ESP) and after ESPwere measured using the OHM and SCEM methods under normal operation conditions of the boiler systemas a result of firing a bituminous coal. The vapor-phase total mercury Hg(VT) concentration declinedwith the decrease of flue gas temperature because of mercury species transformation from oxidizedmercury to particulate mercury as the flue gas moved downstream from the air preheater to the ESPand after the ESP. A good agreement for Hg°, Hg^(2+) and Hg( VT) was obtained between the twomethods in the ash-free area. But in the dense particle-laden flue gas area, there appeared to be abig bias for mercury speciation owing to dust cake formed in the filter of OHM sampling probe. Theparticulateaffinity to the flue gas mercury and the impacts of sampling condition to accuracy ofmeasure were discussed.展开更多
Four months after the Wenchuan Ms 8 earthquake in western Sichuan, China, in situ stress measurements were carried out along the Longmenshan fault zone with the purpose of obtaining stress parameters for earthquake ha...Four months after the Wenchuan Ms 8 earthquake in western Sichuan, China, in situ stress measurements were carried out along the Longmenshan fault zone with the purpose of obtaining stress parameters for earthquake hazard assessment. In-situ stresses were measured in three new boreholes by using overcoring with the piezomagnetic stress gauges for shallow depths and hydraulic fracturing for lower depths. The maximum horizontal stress in shallow depths (-20 m) is about 4.3 MPa, oriented N19°E, in the epicenter area at Yingxiu Town, about 9.7 MPa, oriented N51°W, at Baoxing County in the southwestern Longmenshan range, and about 2.6 MPa, oriented N39°E, near Kangding in the southernmost zone of the Longmenshan range. Hydraulic fracturing at borehole depths from 100 to 400 m shows a tendency towards increasing stress with depth. A comparison with the results measured before the Wenchuan earthquake along the Longmenshan zone and in the Tibetan Plateau demonstrates that the stress level remains relatively high in the southwestern segment of the Longmenshan range, and is still moderate in the epicenter zone. These results provide a key appraisal for future assessment of earthquake hazards of the Longmenshan fault zone and the aftershock occurrences of the Wenchuan earthquake.展开更多
Moisture content is a fundamental physical index that quantifies soil property and is closely associatedwith the hydrological, ecological and engineering behaviors of soil. To measure in-situ soil moisturecontents, a ...Moisture content is a fundamental physical index that quantifies soil property and is closely associatedwith the hydrological, ecological and engineering behaviors of soil. To measure in-situ soil moisturecontents, a distributed measurement system for in-situ soil moisture content (SM-DTS) is introduced.The system is based on carbon-fiber heated cable (CFHC) technology that has been developed to enhancethe measuring accuracy of in-situ soil moisture content. Using CFHC technique, a temperature characteristicvalue (Tt) can be defined from temperatureetime curves. A relationship among Tt, soil thermalimpedance coefficient and soil moisture content is then established in laboratory. The feasibility of theSM-DTS technology to provide distributed measurements of in-situ soil moisture content is verifiedthrough field tests. The research reported herein indicates that the proposed SM-DTS is capable ofmeasuring in-situ soil moisture content over long distances and large areas.展开更多
In-situ stress is an essential parameter for design and construction of most engineering projects that involve excavation in rocks. Progress in in-situ stress measurement from the 1950s in China is briefly introduced....In-situ stress is an essential parameter for design and construction of most engineering projects that involve excavation in rocks. Progress in in-situ stress measurement from the 1950s in China is briefly introduced. Stress relief by overcoring technique and hydraulic fracturing: technique are the two main techniques for in-situ stress measurement in China at present. To make them suitable for application at great depth and to increase their measuring reliability and accuracy, a series of techniques have been developed. Applications and achievements of in-situ stress measurement in Chinese rock engineering, including mining, geotechnical and hydropower engineering, and earthquake prediction, are introduced. Suggestions for further development of in-situ stress measurement are also proposed.展开更多
Compared with the laboratory acoustic measurement of sediment samples, the in-situ acoustic measurement in marine sediment is considered more accurate and rehable, because it covers all of the surrounding environment ...Compared with the laboratory acoustic measurement of sediment samples, the in-situ acoustic measurement in marine sediment is considered more accurate and rehable, because it covers all of the surrounding environment factors and avoids the disturbance during the course of sampling and transporting of sediment samples. A new multi-frequency in-situ geoacoustic measurement system (MFIS^AMS) has been developed. The system can provide acoustic vdocity (compressional wave) and attenuation profiles of the uppermost 4 - 8 m sediment in the seafloor. It consists of 8 channels with 12 frequencies (multi-frequencies) and 0.5 - 2 MHz sampling rates. The data collected can be transmiuted in real-time. Associated with inclinometer and altimeter, it can provide the data for depth emendation. Acoustic velocity and attenuation data have been obtained from two in-situ experiments conducted in the Hangzhou Bay.展开更多
In-situ stress measurement using the hydraulic fracturing technique was made at Wanfu Coal Mine in Shandong Province, China. To solve problems caused by great measuring depth and extra thick overburden soil layers in ...In-situ stress measurement using the hydraulic fracturing technique was made at Wanfu Coal Mine in Shandong Province, China. To solve problems caused by great measuring depth and extra thick overburden soil layers in the mine, a series of improved techniques were developed for the traditional hydraulic fracturing technique and equipment to increase their pressure-enduring ability and to ensure safe and flexible removal of the sealing packers with other experimental apparatus. Successful in-situ stress measurement at 37 points within 7 boreholes, which were mostly over 1000 m deep, was completed. Through the measurement, detailed information of in-situ stress state has been provided for mining design of the mine. The improved hydraulic fracturing technique and equipment also provide reliable tools for in-situ stress measurement at great depth of other mines.展开更多
Common displays such as CRT or LCD screens have limited capabilities in displaying most color spectra correctly. The main disadvantage of these devices is that they work with three primaries and the colors displayed a...Common displays such as CRT or LCD screens have limited capabilities in displaying most color spectra correctly. The main disadvantage of these devices is that they work with three primaries and the colors displayed are the mixture of these three colours. Consequently these devices can be confusing in testing human color identification, because the spectral distribution of the colors displayed is the combined spectrum of the three primaries. We have developed a new instrument for spectrally correct color vision measurement. This instrument uses light emitting diodes (LEDs) and is capable of producing all spectra of perceivable colors, thus with appropriate test methods this instrument can be a reliable and useful tool in test~ing human color vision and in verifying color vision correction.展开更多
The multi-point simultaneous long-term measurement of CO_(2) concentration in seawater can provide more-valuable data for further understanding of the spatial and temporal distribution of CO_(2).Thus,the requirement f...The multi-point simultaneous long-term measurement of CO_(2) concentration in seawater can provide more-valuable data for further understanding of the spatial and temporal distribution of CO_(2).Thus,the requirement for a low-cost sensor with high precision,low power consumption,and a small size is becoming urgent.In this work,an in-situ sensor for CO_(2) detection in seawater,based on a permeable membrane and non-dispersive infrared(NDIR)technology,is developed.The sensor has a small size(Ф66 mm×124 mm),light weight(0.7 kg in air),low power consumption(<0.9 W),low cost(<US$1000),and high-pressure tolerance(<200 m).After laboratory performance tests,the sensor was found to have a measurement range of(0–2000)×10^(-6),and the gas linear correlation R^(2) is 0.99,with a precision of about 0.98%at a sampling rate of 1 s.A comparison measurement was carried out with a commercial sensor in a pool for 7 days,and the results showed a consistent trend.Further,the newly developed sensor was deployed in Qingdao nearshore water for 35 days.The results proved that the sensor could measure the dynamic changes of CO_(2) concentration in seawater continuously,and had the potential to carry out long-term observations on an oceanic platform.It is hoped that the sensor could be applied to field ocean observations in near future.展开更多
With the rapid increase of energy demand and the increasingly highlighted environmental problems, clean, safe and widely distributed geothermal resources have become a hot spot for renewable resources development. The...With the rapid increase of energy demand and the increasingly highlighted environmental problems, clean, safe and widely distributed geothermal resources have become a hot spot for renewable resources development. The state of in-situ stress is a major control parameter for multiple links including well location, fracture inspiration and reservoir assessment, so how to determine the accurate state of in-situ stress in the deep thermal reservoir becomes a core problem drawing widely attention and urgent to be solved. Based on features of hot dry rock reservoir in terms of temperature and pressure and the comparison analysis, this article proposes the method of Anelastic Strain Recovery(ASR) as an effective method for determining the state of in-situ stress in the area with HDR resources distributed and explains the availability of ASR method by application examples.展开更多
Reliable information of in--situ stress state is necessary for the design andconstruction of most important rock projects. As most rock projects are getting deeper and deeper,traditional techniques of in--situ stress ...Reliable information of in--situ stress state is necessary for the design andconstruction of most important rock projects. As most rock projects are getting deeper and deeper,traditional techniques of in--situ stress measurement are not very suitable. The current techniquesof in--situ stress measurement and their insufficiency for use at great depth are analyzed. Somebasic ideas of the development of new techniques and the improvement of current techniques for useat great depth are provided.展开更多
In order to obtain the distribution rules of abutment pressure around the 1151 (3) fully mechanized top-coal caving (FMTC) face of Xieqiao Colliery, the KSE-II-1 type bore-hole stress gauges were installed in the ...In order to obtain the distribution rules of abutment pressure around the 1151 (3) fully mechanized top-coal caving (FMTC) face of Xieqiao Colliery, the KSE-II-1 type bore-hole stress gauges were installed in the tailentry and headentry to measure the mining-induced stress. The distribution rules of the front and side abutment pressure were demonstrated. The results show that distribution rules of stress are obviously different in the vicinity of the face and entries. The peak value of abutment pressure in the protective coal pillar and face are located commonly in front of the working face along the strike, and they are located at the stress-decreased zone near the face. There is no stress peak value in the lateral coal mass beside the headentry in front of the face on the strike, and the peak value of abutment pressure appears at the rear area of the face. There are stress peak values both in the protective coal pillar and in the lateral coal mass beside the headentry to the dip.展开更多
In this article,the relevant instruments and techniques for measuring solid precipitation and blowing snow are reviewed,with a focus on the in situ instrument measurements.Moreover,a literature review and specific obs...In this article,the relevant instruments and techniques for measuring solid precipitation and blowing snow are reviewed,with a focus on the in situ instrument measurements.Moreover,a literature review and specific observation activities for solid precipitation are provided,the working principles of several instruments are introduced,and the advantages and disadvantages,measurement performance,and specific application scenarios of the instruments are evaluated.Currently,there are numerous solid precipitation measurement instruments available,and the standardization and sustainability of these measurements also need to be considered.The purpose of the review is not to be exhaustive but to provide readers with information on the current status of the development of relevant technologies and the prospects for their application in the polar regions.展开更多
A new in-situ seabed acoustic measurement system is developed for direct in-situ measurement of sediment geoacoustic properties (compressional wave velocity and attenuation). The new in-situ system consists of two p...A new in-situ seabed acoustic measurement system is developed for direct in-situ measurement of sediment geoacoustic properties (compressional wave velocity and attenuation). The new in-situ system consists of two parts: the deck control unit and the underwater measurement unit. The underwater measurement unit emits sonic waves that propagate through the seafloor sediment, receives the returning signals, and transmits them to the deck control unit for waveform display and analysis. The entire operation is controlled and monitored in real time by the deck control unit on the research vessel and can provide recording of full waveforms to determine the sound velocity and attenuation. This paper outlines the design of the system, the measurement process, and demonstrates its application in tests carded out on seabed sediment off the Qingdao coast, China. The test results show that the system performed well and rapidly provided accurate in-situ acoustic velocity and attenuation estimates of the seafloor sediment.展开更多
We introduce the first domestic in-situ multi-information measurement system for a gallium nitride (GaN) photo- cathode. This system can successfully fulfill heat cleaning and activation for GaN in an ultrahigh vacu...We introduce the first domestic in-situ multi-information measurement system for a gallium nitride (GaN) photo- cathode. This system can successfully fulfill heat cleaning and activation for GaN in an ultrahigh vacuum environment and produce a GaN photocathode with a negative electron affinity (NEA) status. Information including the heat clean- ing temperature, vacuum degree, photocurrent, electric current of cesium source, oxygen source, and the most important information about the spectral response, or equivalently, the quantum efficiency (QE) can be obtained during prepa- ration. The preparation of a GaN photocathode with this system indicates that the optimal heating temperature in a vacuum is about 700 ~C. We also develop a method of quickly evaluating the atomically clean surface with the vacuum degree versus wavelength curve to prevent possible secondary contamination when the atomic level cleaning surface is tested with X-ray photoelectron spectroscopy. The photocurrent shows a quick enhancement when the current ratio between the cesium source and oxygen source is 1.025. The spectral response of the GaN photocathode is flat in a wavelength range from 240 nm to 365 nm, and an abrupt decline is observed at 365 nm, which demonstrates that with the in-si$u multi-information measurement system the NEA GaN photocathode can be successfully prepared.展开更多
In-situ layerwise imaging measurement of laser powder bed fusion(LPBF)provides a wealth of forming and defect data which enables monitoring of components quality and powder bed homogeneity.Using high-resolution camera...In-situ layerwise imaging measurement of laser powder bed fusion(LPBF)provides a wealth of forming and defect data which enables monitoring of components quality and powder bed homogeneity.Using high-resolution camera layerwise imaging and image processing algorithms to monitor fusion area and powder bed geometric defects has been studied by many researchers,which successfully monitored the contours of components and evaluated their accuracy.However,research for the methods of in-situ 3D contour measurement or component edge warping identification is rare.In this study,a 3D contour mea-surement method combining gray intensity and phase difference is proposed,and its accuracy is verified by designed experiments.The results show that the high-precision of the 3D contours can be achieved by the constructed energy minimization function.This method can detect the deviations of common ge-ometric features as well as warpage at LPBF component edges,and provides fundamental data for in-situ quality monitoring tools.展开更多
In-situ stress measurement for deep reservoir formation is difficult in terms of security, reliability and technique. Acoustic velocity anisotropy test is a basic method for stress measurement of rock cores, which is ...In-situ stress measurement for deep reservoir formation is difficult in terms of security, reliability and technique. Acoustic velocity anisotropy test is a basic method for stress measurement of rock cores, which is based on the distribution of acoustic velocity in different directions around rock cores. The heterogeneity of core samples, such as fractures and gravel contained, can also lead to wave velocity anisotropy. Therefore, the corresponding reliability evaluation method is established to exclude some other anisotropy factors caused by non-tectonic stresses. In this paper, the reliability of testing results is evaluated from three aspects, i.e. phase difference, anisotropy index and waveform, to remove the factors caused by non-tectonic stresses.展开更多
In-situ measurement of internal solitary waves(ISWs)is complicated in the ocean due to their randomness.At present,the ISWs are mainly detected by the chain structure of conductivity-temperature-depth systems(CTDs)or ...In-situ measurement of internal solitary waves(ISWs)is complicated in the ocean due to their randomness.At present,the ISWs are mainly detected by the chain structure of conductivity-temperature-depth systems(CTDs)or temperature sensors.The high cost limits the spatial resolution,which ultimately affects the measuring accuracy of the ISW amplitude.In this paper,we developed an experimental measurement system for detecting ISWs based on the stimulated Raman scattering in distributed optical fibers.This system has the advantages of high precision,low cost,and easy operation.The experimental results show that the system is consistent with CTDs in the measurement of vertical ocean temperature variation.The spatial resolution of the system can reach 1.0 m and the measuring accuracy of temperature is 0.2℃.We successfully detected 3 ISWs by the system in the South China Sea and two optical remote sensing images collected on May 18,2021,the same day of two detected ISWs,verify the occurrence of the measured ISWs.We used the image pairs method to calculate the phase velocity of ISW and the result is 1.71 ms^(-1).By extracting the distances between wave packets,it can be found that the semi-diurnal tide generates the detected ISWs.The impact of the tidal current velocity on the ISW in amplitude is undeniable.Undoubtedly,the system has a great application prospect for detecting ISWs and other dynamic phenomena in the ocean.展开更多
In this paper a pH microprobe technique was developed to measure in-situ the pH value at the electrode/solution interface. Iridium oxide was used as a pH sensitive material with good response behavior in the measured ...In this paper a pH microprobe technique was developed to measure in-situ the pH value at the electrode/solution interface. Iridium oxide was used as a pH sensitive material with good response behavior in the measured solutions. The experimental results indicated that the interfacial pH increased with the applied potential, first jumped to a maximum, then slowly decreased at the controlled potential during the electrodeposition process of functional ceramics.展开更多
The practical method for precise penetration rate measurement in a short time and the instrument design have been specially discussed in this paper.Considering the defects of the penetration rate meters available,via ...The practical method for precise penetration rate measurement in a short time and the instrument design have been specially discussed in this paper.Considering the defects of the penetration rate meters available,via the balanced design in consideration of service life,costs,accuracy and reliability,a kind of penetration rate meter has been put forward.The meter consists of a magnetic clutch,a gear box and a raster disk system to pick up the signal.The meter has the following advantages-it might measure a low speed with higher accura-cy,it could disengage automatically without being divorced from the driving device during tripping rods at high speed,it has a circuit of rotary direction discrimination and of repeated counting prevention so as to eU-minate error caused by rod vibration.展开更多
With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle,...With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle, operation step and data processing in the instrumental analysis, including: calibration curve best linear equation is set up, measurand best linear equation is set up, and calculation of best value of a concentration. The results showed that mean of thrice determination , s = 0 μg/mL, RSD = 0. Results of preliminary application are simply introduced in the basic instrumental analysis for atomic absorption spectrophotometry, ion-selective electrodes, coulometry and polarographic analysis and are contrasted to results of normal measurements.展开更多
文摘The in-situ instrumentation technique for measuring mercury and itsspeciation downstream a utility 100 MW pulverized coal (PC) fired boiler system was developed andconducted by the use of the Ontario hydro method (OHM) consistent with American standard test methodtogether with the semi-continuous emissions monitoring (SCEM) system as well as a mobile laboratoryfor mercury monitoring. The mercury and its speciation concentrations including participate mercuryat three locations of before air preheater, before electrostatic precipitator (ESP) and after ESPwere measured using the OHM and SCEM methods under normal operation conditions of the boiler systemas a result of firing a bituminous coal. The vapor-phase total mercury Hg(VT) concentration declinedwith the decrease of flue gas temperature because of mercury species transformation from oxidizedmercury to particulate mercury as the flue gas moved downstream from the air preheater to the ESPand after the ESP. A good agreement for Hg°, Hg^(2+) and Hg( VT) was obtained between the twomethods in the ash-free area. But in the dense particle-laden flue gas area, there appeared to be abig bias for mercury speciation owing to dust cake formed in the filter of OHM sampling probe. Theparticulateaffinity to the flue gas mercury and the impacts of sampling condition to accuracy ofmeasure were discussed.
基金the auspice of National Key Basic Project(973)(granted No.2008CB425702)National Science and Technology Project(granted No.SinoProbe-06)
文摘Four months after the Wenchuan Ms 8 earthquake in western Sichuan, China, in situ stress measurements were carried out along the Longmenshan fault zone with the purpose of obtaining stress parameters for earthquake hazard assessment. In-situ stresses were measured in three new boreholes by using overcoring with the piezomagnetic stress gauges for shallow depths and hydraulic fracturing for lower depths. The maximum horizontal stress in shallow depths (-20 m) is about 4.3 MPa, oriented N19°E, in the epicenter area at Yingxiu Town, about 9.7 MPa, oriented N51°W, at Baoxing County in the southwestern Longmenshan range, and about 2.6 MPa, oriented N39°E, near Kangding in the southernmost zone of the Longmenshan range. Hydraulic fracturing at borehole depths from 100 to 400 m shows a tendency towards increasing stress with depth. A comparison with the results measured before the Wenchuan earthquake along the Longmenshan zone and in the Tibetan Plateau demonstrates that the stress level remains relatively high in the southwestern segment of the Longmenshan range, and is still moderate in the epicenter zone. These results provide a key appraisal for future assessment of earthquake hazards of the Longmenshan fault zone and the aftershock occurrences of the Wenchuan earthquake.
基金The financial supports provided by the National Natural Science Foundation of China(Grant Nos.41230636,41372265,41427801)National Basic Research Program of China(973 Project)(Grant No.2011CB710605)
文摘Moisture content is a fundamental physical index that quantifies soil property and is closely associatedwith the hydrological, ecological and engineering behaviors of soil. To measure in-situ soil moisturecontents, a distributed measurement system for in-situ soil moisture content (SM-DTS) is introduced.The system is based on carbon-fiber heated cable (CFHC) technology that has been developed to enhancethe measuring accuracy of in-situ soil moisture content. Using CFHC technique, a temperature characteristicvalue (Tt) can be defined from temperatureetime curves. A relationship among Tt, soil thermalimpedance coefficient and soil moisture content is then established in laboratory. The feasibility of theSM-DTS technology to provide distributed measurements of in-situ soil moisture content is verifiedthrough field tests. The research reported herein indicates that the proposed SM-DTS is capable ofmeasuring in-situ soil moisture content over long distances and large areas.
文摘In-situ stress is an essential parameter for design and construction of most engineering projects that involve excavation in rocks. Progress in in-situ stress measurement from the 1950s in China is briefly introduced. Stress relief by overcoring technique and hydraulic fracturing: technique are the two main techniques for in-situ stress measurement in China at present. To make them suitable for application at great depth and to increase their measuring reliability and accuracy, a series of techniques have been developed. Applications and achievements of in-situ stress measurement in Chinese rock engineering, including mining, geotechnical and hydropower engineering, and earthquake prediction, are introduced. Suggestions for further development of in-situ stress measurement are also proposed.
基金supported by the National High Technology Research and Development Program of China(863 Pro-gram, Grant No.2005AA615040)the National Natural Science Foundation of China(Grant No.40776038)+2 种基金Open Fund of Key Laboratory of Geo-detection(China University of Geosciences,Beijing),Ministry of Education (GrantNo. GDL0802)the Ocean Public Welfare Scientific Research Special Appropriation Project(Grant Nos.200805079and 200805005)the Open Fund of Key Laboratory of Submarine Geoscience,State Oceanic Administration(Grant No. KCSG0803)
文摘Compared with the laboratory acoustic measurement of sediment samples, the in-situ acoustic measurement in marine sediment is considered more accurate and rehable, because it covers all of the surrounding environment factors and avoids the disturbance during the course of sampling and transporting of sediment samples. A new multi-frequency in-situ geoacoustic measurement system (MFIS^AMS) has been developed. The system can provide acoustic vdocity (compressional wave) and attenuation profiles of the uppermost 4 - 8 m sediment in the seafloor. It consists of 8 channels with 12 frequencies (multi-frequencies) and 0.5 - 2 MHz sampling rates. The data collected can be transmiuted in real-time. Associated with inclinometer and altimeter, it can provide the data for depth emendation. Acoustic velocity and attenuation data have been obtained from two in-situ experiments conducted in the Hangzhou Bay.
基金supported by the National Natural Science Foundation of China (No. 50490271)
文摘In-situ stress measurement using the hydraulic fracturing technique was made at Wanfu Coal Mine in Shandong Province, China. To solve problems caused by great measuring depth and extra thick overburden soil layers in the mine, a series of improved techniques were developed for the traditional hydraulic fracturing technique and equipment to increase their pressure-enduring ability and to ensure safe and flexible removal of the sealing packers with other experimental apparatus. Successful in-situ stress measurement at 37 points within 7 boreholes, which were mostly over 1000 m deep, was completed. Through the measurement, detailed information of in-situ stress state has been provided for mining design of the mine. The improved hydraulic fracturing technique and equipment also provide reliable tools for in-situ stress measurement at great depth of other mines.
文摘Common displays such as CRT or LCD screens have limited capabilities in displaying most color spectra correctly. The main disadvantage of these devices is that they work with three primaries and the colors displayed are the mixture of these three colours. Consequently these devices can be confusing in testing human color identification, because the spectral distribution of the colors displayed is the combined spectrum of the three primaries. We have developed a new instrument for spectrally correct color vision measurement. This instrument uses light emitting diodes (LEDs) and is capable of producing all spectra of perceivable colors, thus with appropriate test methods this instrument can be a reliable and useful tool in test~ing human color vision and in verifying color vision correction.
基金Supported by the National Nature Science Foundation of China(No.41527901)the Provincial Key Research and Development Program of Shandong,China(No.2019JZZY010417)the Special Program of Shandong Province for Qingdao Pilot National Laboratory of Marine Science and Technology(No.2021QNLM020002).
文摘The multi-point simultaneous long-term measurement of CO_(2) concentration in seawater can provide more-valuable data for further understanding of the spatial and temporal distribution of CO_(2).Thus,the requirement for a low-cost sensor with high precision,low power consumption,and a small size is becoming urgent.In this work,an in-situ sensor for CO_(2) detection in seawater,based on a permeable membrane and non-dispersive infrared(NDIR)technology,is developed.The sensor has a small size(Ф66 mm×124 mm),light weight(0.7 kg in air),low power consumption(<0.9 W),low cost(<US$1000),and high-pressure tolerance(<200 m).After laboratory performance tests,the sensor was found to have a measurement range of(0–2000)×10^(-6),and the gas linear correlation R^(2) is 0.99,with a precision of about 0.98%at a sampling rate of 1 s.A comparison measurement was carried out with a commercial sensor in a pool for 7 days,and the results showed a consistent trend.Further,the newly developed sensor was deployed in Qingdao nearshore water for 35 days.The results proved that the sensor could measure the dynamic changes of CO_(2) concentration in seawater continuously,and had the potential to carry out long-term observations on an oceanic platform.It is hoped that the sensor could be applied to field ocean observations in near future.
基金founded by Project of National Natural Science Foundation of China “Study on the Anelastic Strain Recovery Compliance in the In-situ Stress Measurement by ASR Method”, No 41404080the Project of Geological Survey “Survey on the In-situ Stress Field in Southern China”
文摘With the rapid increase of energy demand and the increasingly highlighted environmental problems, clean, safe and widely distributed geothermal resources have become a hot spot for renewable resources development. The state of in-situ stress is a major control parameter for multiple links including well location, fracture inspiration and reservoir assessment, so how to determine the accurate state of in-situ stress in the deep thermal reservoir becomes a core problem drawing widely attention and urgent to be solved. Based on features of hot dry rock reservoir in terms of temperature and pressure and the comparison analysis, this article proposes the method of Anelastic Strain Recovery(ASR) as an effective method for determining the state of in-situ stress in the area with HDR resources distributed and explains the availability of ASR method by application examples.
文摘Reliable information of in--situ stress state is necessary for the design andconstruction of most important rock projects. As most rock projects are getting deeper and deeper,traditional techniques of in--situ stress measurement are not very suitable. The current techniquesof in--situ stress measurement and their insufficiency for use at great depth are analyzed. Somebasic ideas of the development of new techniques and the improvement of current techniques for useat great depth are provided.
基金Supported by the National Natural Science Foundation of Anhui Province (K J2010A090)
文摘In order to obtain the distribution rules of abutment pressure around the 1151 (3) fully mechanized top-coal caving (FMTC) face of Xieqiao Colliery, the KSE-II-1 type bore-hole stress gauges were installed in the tailentry and headentry to measure the mining-induced stress. The distribution rules of the front and side abutment pressure were demonstrated. The results show that distribution rules of stress are obviously different in the vicinity of the face and entries. The peak value of abutment pressure in the protective coal pillar and face are located commonly in front of the working face along the strike, and they are located at the stress-decreased zone near the face. There is no stress peak value in the lateral coal mass beside the headentry in front of the face on the strike, and the peak value of abutment pressure appears at the rear area of the face. There are stress peak values both in the protective coal pillar and in the lateral coal mass beside the headentry to the dip.
基金supported by the National Key Research and Development Program of China(Grant no.2021YFC2802501).
文摘In this article,the relevant instruments and techniques for measuring solid precipitation and blowing snow are reviewed,with a focus on the in situ instrument measurements.Moreover,a literature review and specific observation activities for solid precipitation are provided,the working principles of several instruments are introduced,and the advantages and disadvantages,measurement performance,and specific application scenarios of the instruments are evaluated.Currently,there are numerous solid precipitation measurement instruments available,and the standardization and sustainability of these measurements also need to be considered.The purpose of the review is not to be exhaustive but to provide readers with information on the current status of the development of relevant technologies and the prospects for their application in the polar regions.
基金Supported by the National Special Research Fund for Non-Profit Marine Sector(No.200905025)
文摘A new in-situ seabed acoustic measurement system is developed for direct in-situ measurement of sediment geoacoustic properties (compressional wave velocity and attenuation). The new in-situ system consists of two parts: the deck control unit and the underwater measurement unit. The underwater measurement unit emits sonic waves that propagate through the seafloor sediment, receives the returning signals, and transmits them to the deck control unit for waveform display and analysis. The entire operation is controlled and monitored in real time by the deck control unit on the research vessel and can provide recording of full waveforms to determine the sound velocity and attenuation. This paper outlines the design of the system, the measurement process, and demonstrates its application in tests carded out on seabed sediment off the Qingdao coast, China. The test results show that the system performed well and rapidly provided accurate in-situ acoustic velocity and attenuation estimates of the seafloor sediment.
基金Project supported by the National Natural Science Foundation of China (Grant No. 60871012)the Natural Science Foundation of Shandong Province,China (Grant No. ZR2011FQ027)
文摘We introduce the first domestic in-situ multi-information measurement system for a gallium nitride (GaN) photo- cathode. This system can successfully fulfill heat cleaning and activation for GaN in an ultrahigh vacuum environment and produce a GaN photocathode with a negative electron affinity (NEA) status. Information including the heat clean- ing temperature, vacuum degree, photocurrent, electric current of cesium source, oxygen source, and the most important information about the spectral response, or equivalently, the quantum efficiency (QE) can be obtained during prepa- ration. The preparation of a GaN photocathode with this system indicates that the optimal heating temperature in a vacuum is about 700 ~C. We also develop a method of quickly evaluating the atomically clean surface with the vacuum degree versus wavelength curve to prevent possible secondary contamination when the atomic level cleaning surface is tested with X-ray photoelectron spectroscopy. The photocurrent shows a quick enhancement when the current ratio between the cesium source and oxygen source is 1.025. The spectral response of the GaN photocathode is flat in a wavelength range from 240 nm to 365 nm, and an abrupt decline is observed at 365 nm, which demonstrates that with the in-si$u multi-information measurement system the NEA GaN photocathode can be successfully prepared.
基金This work was supported by the foundation of Key Research and Development Program of Hubei Province(2020BAB137)Shen-zhen Fundamental Research Program(JCYJ20210324142007022).
文摘In-situ layerwise imaging measurement of laser powder bed fusion(LPBF)provides a wealth of forming and defect data which enables monitoring of components quality and powder bed homogeneity.Using high-resolution camera layerwise imaging and image processing algorithms to monitor fusion area and powder bed geometric defects has been studied by many researchers,which successfully monitored the contours of components and evaluated their accuracy.However,research for the methods of in-situ 3D contour measurement or component edge warping identification is rare.In this study,a 3D contour mea-surement method combining gray intensity and phase difference is proposed,and its accuracy is verified by designed experiments.The results show that the high-precision of the 3D contours can be achieved by the constructed energy minimization function.This method can detect the deviations of common ge-ometric features as well as warpage at LPBF component edges,and provides fundamental data for in-situ quality monitoring tools.
基金Supported by the PetroChina Company Limited (112002Kt0090001)
文摘In-situ stress measurement for deep reservoir formation is difficult in terms of security, reliability and technique. Acoustic velocity anisotropy test is a basic method for stress measurement of rock cores, which is based on the distribution of acoustic velocity in different directions around rock cores. The heterogeneity of core samples, such as fractures and gravel contained, can also lead to wave velocity anisotropy. Therefore, the corresponding reliability evaluation method is established to exclude some other anisotropy factors caused by non-tectonic stresses. In this paper, the reliability of testing results is evaluated from three aspects, i.e. phase difference, anisotropy index and waveform, to remove the factors caused by non-tectonic stresses.
基金National Natural Science Foundation of China(Nos.61871353,62031005)。
文摘In-situ measurement of internal solitary waves(ISWs)is complicated in the ocean due to their randomness.At present,the ISWs are mainly detected by the chain structure of conductivity-temperature-depth systems(CTDs)or temperature sensors.The high cost limits the spatial resolution,which ultimately affects the measuring accuracy of the ISW amplitude.In this paper,we developed an experimental measurement system for detecting ISWs based on the stimulated Raman scattering in distributed optical fibers.This system has the advantages of high precision,low cost,and easy operation.The experimental results show that the system is consistent with CTDs in the measurement of vertical ocean temperature variation.The spatial resolution of the system can reach 1.0 m and the measuring accuracy of temperature is 0.2℃.We successfully detected 3 ISWs by the system in the South China Sea and two optical remote sensing images collected on May 18,2021,the same day of two detected ISWs,verify the occurrence of the measured ISWs.We used the image pairs method to calculate the phase velocity of ISW and the result is 1.71 ms^(-1).By extracting the distances between wave packets,it can be found that the semi-diurnal tide generates the detected ISWs.The impact of the tidal current velocity on the ISW in amplitude is undeniable.Undoubtedly,the system has a great application prospect for detecting ISWs and other dynamic phenomena in the ocean.
文摘In this paper a pH microprobe technique was developed to measure in-situ the pH value at the electrode/solution interface. Iridium oxide was used as a pH sensitive material with good response behavior in the measured solutions. The experimental results indicated that the interfacial pH increased with the applied potential, first jumped to a maximum, then slowly decreased at the controlled potential during the electrodeposition process of functional ceramics.
文摘The practical method for precise penetration rate measurement in a short time and the instrument design have been specially discussed in this paper.Considering the defects of the penetration rate meters available,via the balanced design in consideration of service life,costs,accuracy and reliability,a kind of penetration rate meter has been put forward.The meter consists of a magnetic clutch,a gear box and a raster disk system to pick up the signal.The meter has the following advantages-it might measure a low speed with higher accura-cy,it could disengage automatically without being divorced from the driving device during tripping rods at high speed,it has a circuit of rotary direction discrimination and of repeated counting prevention so as to eU-minate error caused by rod vibration.
文摘With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle, operation step and data processing in the instrumental analysis, including: calibration curve best linear equation is set up, measurand best linear equation is set up, and calculation of best value of a concentration. The results showed that mean of thrice determination , s = 0 μg/mL, RSD = 0. Results of preliminary application are simply introduced in the basic instrumental analysis for atomic absorption spectrophotometry, ion-selective electrodes, coulometry and polarographic analysis and are contrasted to results of normal measurements.