A distributed measurement method for in-situ soil moisture content by using carbon-fiber heated cable 被引量:13
1
作者 Dingfeng Cao Bin Shi +3 位作者 Honghu Zhu Guangqing Wei Shen-En Chen Junfan Yan 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2015年第6期700-707,共8页
Moisture content is a fundamental physical index that quantifies soil property and is closely associatedwith the hydrological, ecological and engineering behaviors of soil. To measure in-situ soil moisturecontents, a ... Moisture content is a fundamental physical index that quantifies soil property and is closely associatedwith the hydrological, ecological and engineering behaviors of soil. To measure in-situ soil moisturecontents, a distributed measurement system for in-situ soil moisture content (SM-DTS) is introduced.The system is based on carbon-fiber heated cable (CFHC) technology that has been developed to enhancethe measuring accuracy of in-situ soil moisture content. Using CFHC technique, a temperature characteristicvalue (Tt) can be defined from temperatureetime curves. A relationship among Tt, soil thermalimpedance coefficient and soil moisture content is then established in laboratory. The feasibility of theSM-DTS technology to provide distributed measurements of in-situ soil moisture content is verifiedthrough field tests. The research reported herein indicates that the proposed SM-DTS is capable ofmeasuring in-situ soil moisture content over long distances and large areas. 展开更多
关键词 in-situ soil moisture content Distributed measurement Carbon-fiber heated cable (CFHC) Fiber-optic sensing
下载PDF
Analysis of a Simple Probe for <i>In-Situ</i>Resistivity Measurements
2
作者 Jens Munk Todd Petersen +1 位作者 Matt Cullin William Schnabel 《Journal of Water Resource and Protection》 2017年第1期1-10,共10页
We present a probe factor for a simple measurement device, which can be used to determine in-situ electrical resistivity in soils or other penetrable bodies. The probe is primarily sensitive to the material immediatel... We present a probe factor for a simple measurement device, which can be used to determine in-situ electrical resistivity in soils or other penetrable bodies. The probe is primarily sensitive to the material immediately surrounding it and therefore is ideal for determining localized conductivities. The geometry of the probe can be scaled to effectively adjust the region of interest. The calibration, or “probe factor” is a function of the geometry, as well as the electrode configuration. Results are presented assuming a Wenner array configuration, however they can easily be extended to other geometries, such as the Schlumberger or dipole-dipole array. 展开更多
关键词 ELECTRICAL resistIVITY measurements soil Moisture ELECTRICAL CONDUCTIVITY GEOPHYSICAL measurement
下载PDF
接地电阻测量仪智能化改造方法的研究
3
作者 杨思元 陈梓荣 +1 位作者 林来鑫 马俊深 《自动化应用》 2024年第9期100-102,共3页
为了解决传统接地电阻测量工作存在的测量数据不便、记录不准确、数据利用不深入等问题,对接地电阻测量仪进行智能化改造,设计开发数据采集模块连接接地电阻测量仪及土壤电阻率测量仪,将接地电阻测量工作与土壤电阻率测量工作结合,简化... 为了解决传统接地电阻测量工作存在的测量数据不便、记录不准确、数据利用不深入等问题,对接地电阻测量仪进行智能化改造,设计开发数据采集模块连接接地电阻测量仪及土壤电阻率测量仪,将接地电阻测量工作与土壤电阻率测量工作结合,简化接地电阻测量工作流程,转变数据测量及录入工作模式,将接地电阻数据与土壤电阻率结合,并实现测量数据的全自动化读取录入,将工作向智能化、自动化方法引领,使得数量庞大的测量数据可以表达更多内容,更大化发挥数据的作用,使得数据联动性更强、可分析性更高。 展开更多
关键词 接地电阻 智能化改造 土壤电阻率 接地电阻测量仪
下载PDF
基于接地电阻测量仪的数据管理系统设计
4
作者 马俊深 林来鑫 +1 位作者 陈梓荣 杨思元 《电工技术》 2024年第9期135-138,共4页
接地电阻测量仪的数据管理是接地电阻测量工作的重要内容之一。为使数量庞大的接地电阻测量数据可表达更多内容,发挥更大作用,设计了数据管理系统。结合土壤电阻率数据,对接地系统的情况进行分析,使得数据联动性更强,可分析程度更高。
关键词 接地电阻测量仪 数据 土壤电阻率 管理系统
下载PDF
MEASUREMENT OF SOLID SLURRY FLOW VIA CORRELATION OF ELECTROMAGNETIC FLOW METER,ELECTRICAL RESISTANCE TOMOGRAPHY AND MECHANISTIC MODELLING 被引量:3
5
作者 XU Jing-yu WU Ying-xiang +5 位作者 ZHENG Zhi-chu WANG M. MUNIR B. OLUWADAREY H. I. SCHLABERG H. I. WILLIAMS R. A. 《Journal of Hydrodynamics》 SCIE EI CSCD 2009年第4期557-563,共7页
The study presented here was carried out to obtain the actual solids flow rate by the combination of electrical resistance tomography and electromagnetic flow meter. A new in-situ measurement method based on measureme... The study presented here was carried out to obtain the actual solids flow rate by the combination of electrical resistance tomography and electromagnetic flow meter. A new in-situ measurement method based on measurements of the Electromagnetic Flow Meters (EFM) and Electrical Resistance Tomography (ERT) to study the flow rates of individual phases in a vertical flow was proposed. The study was based on laboratory experiments that were carded out with a 50 mm vertical flow rig for a number of sand concentrations and different mixture velocities. A range of sand slurries with median particle size from 212 μm to 355 μm was tested. The solid concentration by volume covered was 5% and 15%, and the corresponding density of 5% was 1078 kg/m^3 and of 15% was 1238 kg/m^3. The flow velocity was between 1.5 m/s and 3.0 m/s. A total of 6 experimental tests were conducted. The equivalent liquid model was adopted to validate in-situ volumetric solids fraction and calculate the slip velocity. The results show that the ERT technique can be used in conjunction with an electromagnetic flow meter as a way of measurement of slurry flow rate in a vertical pipe flow. However it should be emphasized that the EFM results must be treated with reservation when the flow pattern at the EFM mounting position is a non-homogenous flow. The flow rate obtained by the EFM should be corrected considering the slip velocity and the flow pattern. 展开更多
关键词 slurry measurement Electrical resistance Tomography (ERT) Electromagnetic Flow Meters (EFM) in-situ mean volumetric fraction slip velocity
原文传递
Influence of Precipitation on the Determination of Proper Time for Soil Resistivity Measurement 被引量:1
6
作者 李良福 李航 +1 位作者 向波 覃彬全 《Acta meteorologica Sinica》 SCIE 2010年第2期259-268,共10页
In order to obtain reliable and effective upland soil resistivity measurements,it is necessary to know how much time after the rain stops is required before making soil resistivity observations so that the influence o... In order to obtain reliable and effective upland soil resistivity measurements,it is necessary to know how much time after the rain stops is required before making soil resistivity observations so that the influence of precipitation on the measurements can be eliminated.Based on the soil resistivity monitoring data at different depths obtained from the soil conductance automatic monitoring system using the triple-electrode method,and the precipitation data from the synchronous and automatic observing system in Hechuan County of Chongqing,this paper analyzed the effect of rain on the determination of upland soil resistivity measurement time.The results showed that the required interval time between the measurement and the termination of rain should be as follows:if the rainfall was less than 0.1 mm,the interval time was zero;the interval time was 24 h if the precipitation time was less than 1 h or the rainfall was 0.1-2.0 mm;the interval time was 72 h if the precipitation time was 2-10 h or the rainfall was within 2.1-5.0 mm;and the interval time of 72-232 h was observed when the precipitation time was 10-25 h or longer or the rainfall was 5.0-10.1 mm or larger.Relevant observations showed that the above conclusions were on the whole valid for different soil depths.On the other hand,the results indicated that the maximum variance ratio for the influence of precipitation on resistivity measurement was about 28.9%,and the average variance was about 3.9%.Moreover,a preliminary analysis also showed that the precipitation process time might play a more crucial role in the resistivity recovery time than the precipitation amount.It is also found that it is practically better to use the rank correlation method than the numerical correlation analysis method to determine the time break between the stop of rain and the time to carry out the soil resistivity measurement. 展开更多
关键词 PRECIPITATION effect soil resistivity measurement time
原文传递
阶梯作用下土质边坡坡面流的水力学特性试验研究
7
作者 张崟崟 何贵平 +1 位作者 雷孝章 陈前 《西北水电》 2023年第6期12-17,共6页
为了探究阶梯布置下土质边坡的阻力规律及产沙特性,揭示阶梯布置下土壤侵蚀水力学机理,将阶梯消能工运用到坡面流中,通过室内放水冲刷试验,研究土质边坡在西南地区常见坡度(10°)、4个放水流量(2、4、8、16 L/min)、4个阶梯级数(裸... 为了探究阶梯布置下土质边坡的阻力规律及产沙特性,揭示阶梯布置下土壤侵蚀水力学机理,将阶梯消能工运用到坡面流中,通过室内放水冲刷试验,研究土质边坡在西南地区常见坡度(10°)、4个放水流量(2、4、8、16 L/min)、4个阶梯级数(裸坡、一级、二级、三级)和2个阶梯高度(1、2 cm)条件下的水力学特性。结果表明:裸坡条件下平均流速与流量成线性关系,布置阶梯后转为幂函数关系;流程一定时,阶梯级数越多阶梯消能效果越好;二级和三级阶梯,阶梯高度2 cm的平均产沙量小于1 cm,一级则相反。通过阻力分析得出,阶梯可以增加坡面阻力,降低坡面径流平均流速、壅高坡面平均水深,使得径流对坡面土颗粒的侵蚀作用减弱,从而减少输沙量。 展开更多
关键词 坡面流 土壤侵蚀 工程措施 阻力系数 阶梯布置
下载PDF
高速铁路盐渍土路基填料复掺改良试验研究 被引量:1
8
作者 申涛 《路基工程》 2023年第4期32-36,共5页
利用复掺水泥+S95级矿粉+煤系偏高岭土(CMK)方式对取自包银铁路的盐渍土进行改良试验,结果表明:掺入CMK能明显改善土体结构,增强密实度和稳定性,提高强度和抗渗性能,固结物含量、强度随CMK掺量增加呈先增大后减小变化特征,渗透系数随CM... 利用复掺水泥+S95级矿粉+煤系偏高岭土(CMK)方式对取自包银铁路的盐渍土进行改良试验,结果表明:掺入CMK能明显改善土体结构,增强密实度和稳定性,提高强度和抗渗性能,固结物含量、强度随CMK掺量增加呈先增大后减小变化特征,渗透系数随CMK掺量增加呈先减小后增大变化特征;随着CMK掺量提升,最优含水率逐渐增大,土体内部的孔隙水含量增加,土体的导电性随之增大,电阻率随着CMK掺量增加而减小;盐渍土∶水泥∶S95级矿粉∶CMK=90∶2∶6∶2为最佳的路基改良处治方案,其固结物含量最高,强度可提高数倍,抗渗性提升一个数量级以上,电阻率提升2.8~3.3倍。 展开更多
关键词 路基填料 水泥+S95级矿粉+煤系偏高岭土复掺 改良盐渍土 固结物含量 渗透系数 电阻率
下载PDF
考虑实测锤击数影响的动力触探杆长修正系数研究
9
作者 刘慧 沈志平 付君宜 《岩土力学》 EI CAS CSCD 北大核心 2023年第7期2050-2063,共14页
现行规范中动力触探锤击数修正系数的确定需考虑实测锤击数影响,而业内对此少有研究。在一次人工做功击打时,动力触探落锤和探杆通过碰撞传递机械能,基于一维碰撞理论,若恢复系数不为0,则二者碰撞后速度不等,在重力和土阻力作用下会继... 现行规范中动力触探锤击数修正系数的确定需考虑实测锤击数影响,而业内对此少有研究。在一次人工做功击打时,动力触探落锤和探杆通过碰撞传递机械能,基于一维碰撞理论,若恢复系数不为0,则二者碰撞后速度不等,在重力和土阻力作用下会继续碰撞。推导了仅计算首次碰撞后探杆能量、计算首次碰撞后落锤与探杆能量之和及计算首次碰撞后有限次碰撞3种计算方案下的杆长修正系数计算方法。研究结果表明:在碰撞过程中和在一次人工做功击打的两次碰撞间是否考虑土体阻力作用,对杆长修正系数的计算都有影响。使用计算首次碰撞后落锤与探杆能量和的计算函数对现行规范中杆长修正系数拟合,得到重型和超重型决定系数分别为0.9935、0.9751。仅考虑两次碰撞间土体对探杆阻力的影响,使用计算首次碰撞后有限次碰撞的计算方法,当恢复系数≤0.3时,计算得到的杆长修正系数随锤击数增大而减小。 展开更多
关键词 动力触探 修正系数 一维碰撞理论 实测锤击数 土体对探杆阻力
下载PDF
高应变实测曲线拟合法在PHC桩周土阻力分布计算中的应用
10
作者 赵月 《建材技术与应用》 2023年第6期32-36,共5页
基于高应变动测技术原理,在预应力混凝土管桩工程的静载试验桩中进行高应变动力检测,对采集的有效力和速度信号进行实测曲线拟合法计算,得出PHC桩周土阻力分布数据,为优化工程桩的选型与布置设计提供参考。
关键词 高应变动测 实测曲线拟合法 预应力混凝土管桩 桩周土阻力
下载PDF
引线间互感对土壤电阻率测量结果的影响 被引量:7
11
作者 鲁志伟 常树生 +2 位作者 兰淑丽 李越 许政委 《高电压技术》 EI CAS CSCD 北大核心 2004年第5期28-30,共3页
测量引线间互感可能造成土壤电阻率的测量误差。计算了引线间互感对土壤电阻率测量的影响。结果表明 ,当均匀土壤电阻率或多层土壤中下层土壤电阻率较低时 ,引线间互感可能造成较大的测量误差 ;采用短电压极距的不等极距四极法 。
关键词 土壤电阻率 测量误差 接地系统 互感仪器 电流引线
下载PDF
沙质林地土壤阻抗系数测量方法 被引量:7
12
作者 朱教君 徐大勇 +2 位作者 康宏樟 Gonda Yutaka Matsuzaki Takeshi 《生态学杂志》 CAS CSCD 北大核心 2005年第2期222-227,共6页
介绍了土壤阻抗系数的测量目的及测量的一般方法 ;重点描述了应用大地阻抗仪 (YokogawaType 32 4 4 ) (specificearthresistancetester)测量沙质林地土壤阻抗系数的理论背景和室内、外操作步骤与数据处理方法。结果表明 ,使用 32 4 4大... 介绍了土壤阻抗系数的测量目的及测量的一般方法 ;重点描述了应用大地阻抗仪 (YokogawaType 32 4 4 ) (specificearthresistancetester)测量沙质林地土壤阻抗系数的理论背景和室内、外操作步骤与数据处理方法。结果表明 ,使用 32 4 4大地阻抗仪 ,即运用Wenner法测量沙质林地土壤阻抗系数是可行的 ,其测量结果在对土壤分层、确定表层土壤含水量、初步确定地下水位等具有一定的应用前景。 展开更多
关键词 土壤阻抗系数 土壤阻抗 Yokogawa TYPE 3244 测量方法 沙质土壤
下载PDF
一般化三电极接地电阻测量方法 被引量:6
13
作者 王涛 时卫东 +4 位作者 张小青 陈灏 王杰 盛才旺 刘峰 《中国电力》 CSCD 北大核心 2011年第3期31-33,共3页
推荐一般化三电极接地电阻测量方法,运用此方法可以将电压测量电极在一圆形轨迹上任意位置移动。根据三电极测量布极系统的阻抗计算公式推导出此圆形轨迹的圆心位置和半径,为了校验该一般化方法,与国际推荐的直线法、三角形法进行比较,... 推荐一般化三电极接地电阻测量方法,运用此方法可以将电压测量电极在一圆形轨迹上任意位置移动。根据三电极测量布极系统的阻抗计算公式推导出此圆形轨迹的圆心位置和半径,为了校验该一般化方法,与国际推荐的直线法、三角形法进行比较,测量了单根垂直接地体和组合接地体的接地电阻,结果表明3种方法测得的数据都能够较好地吻合,证明该一般化测量方法具有可行性,且测量电极设置位置灵活,不受测量现场地形和地貌的限制,便于布线实施测量。 展开更多
关键词 接地电阻 测量电极 接地装置 土壤电阻率
下载PDF
我国土壤酸化的原因及改良措施研究进展 被引量:23
14
作者 张璐 逄洪波 +2 位作者 张雨欣 金海涛 王子琪 《贵州农业科学》 CAS 2017年第8期49-52,共4页
土壤酸化已成为制约我国经济、社会发展的重要环境问题之一。为我国酸性土壤的改良提供参考,分析了氮沉降、酸沉降、工业生产废物、农作物种植导致我国目前土壤酸化的主要原因及其防治措施,并介绍了具有发展前景的微生物和生物炭改良法。
关键词 土壤酸化 防治措施 铝胁迫 耐酸植物
下载PDF
垂直分层土壤中接地电阻的测量及其误差分析 被引量:11
15
作者 鲁志伟 史艳玲 文习山 《高电压技术》 EI CAS CSCD 北大核心 2001年第3期36-38,41,共4页
分析了垂直分层土壤结构中的接地系统接地电阻测量电极的布极规律及测量中可能产生的误差。提出了一种新方法—反向修正系数法 ,可供工程实际参考。
关键词 接地电阻 测量 误差分析 5D-0.618直线法
下载PDF
现场杆塔接地电阻和土壤电阻率测量存在问题及误差分析 被引量:10
16
作者 颜喜平 许根养 +5 位作者 敬亮兵 张杰 江龙才 李志娟 马福 李景禄 《电瓷避雷器》 CAS 2008年第3期38-41,共4页
介绍了杆塔接地电阻和土壤电阻率的测量原理和测量方法,针对安徽池州供电局的4条110kV输电线路杆塔接地电阻和土壤电阻率的测量误差,采用数据对比、理论计算的方法并配合电路模型,分析了杆塔接地电阻测量误差的产生原因。结果表明:杆塔... 介绍了杆塔接地电阻和土壤电阻率的测量原理和测量方法,针对安徽池州供电局的4条110kV输电线路杆塔接地电阻和土壤电阻率的测量误差,采用数据对比、理论计算的方法并配合电路模型,分析了杆塔接地电阻测量误差的产生原因。结果表明:杆塔接地电阻测量时,宜采用直线三级法;电流极的布线长度至少应达到接地网对角线的2倍;布线方向应尽量和塔体基座垂直;测量时应在晴朗天气下进行。 展开更多
关键词 杆塔接地电阻 土壤电阻率 接地电阻测试仪 测量误差
下载PDF
垂直分层土壤中测试电极布置对变电站接地电阻测量值的影响 被引量:14
17
作者 曾嵘 何金良 +2 位作者 高延庆 孙为民 姚金霞 《电网技术》 EI CSCD 北大核心 2000年第10期36-39,共4页
采用数值计算方法分析了垂直分层土壤结构中的接地系统接地电阻测量时测量电极的布置规律。分析了接地系统布置在不同位置时 ,不同方向布置测量线路所要求的电压极的正确位置。分析表明 ,更加科学、合理的测量方法应当是在了解接地系统... 采用数值计算方法分析了垂直分层土壤结构中的接地系统接地电阻测量时测量电极的布置规律。分析了接地系统布置在不同位置时 ,不同方向布置测量线路所要求的电压极的正确位置。分析表明 ,更加科学、合理的测量方法应当是在了解接地系统附近的土壤分层结构情况的基础上 ,选择合理的电流极的引线方向及电压极的布置位置 ,才能得到比较准确的测量结果 ,才能做到对测量结果与真实值之间的差别心中有数。 展开更多
关键词 接地电阻 测量值 变电站 电极布置 垂直分层土壤
下载PDF
土的电阻率原位测试技术研究 被引量:4
18
作者 查甫生 刘松玉 +2 位作者 杜延军 崔可锐 蔡国军 《工程勘察》 CSCD 北大核心 2009年第1期18-23,共6页
土的电阻率是土的基本物性参数之一,可反映土的工程力学性质,具有重要的理论意义和应用价值。原位测试是研究土的电阻率理论的主要方法之一。本文针对目前国内土的电阻率现场测试技术研究的空白,在介绍土的电阻率原位测试原理的基础上,... 土的电阻率是土的基本物性参数之一,可反映土的工程力学性质,具有重要的理论意义和应用价值。原位测试是研究土的电阻率理论的主要方法之一。本文针对目前国内土的电阻率现场测试技术研究的空白,在介绍土的电阻率原位测试原理的基础上,总结了国、内外常用的土电阻率测试方法,并对各种方法的优、缺点进行了概括。文章最后通过购进的多功能原位测试系统(CPTU)中的电阻率探头(RCPT)对典型软土的电阻率测试,分析了电阻率指标在土体基本性质评价中的应用,论证了土的电阻率原位测试技术的可靠性。 展开更多
关键词 土的电阻率 原位测试技术 软土
下载PDF
三角法测量双层土壤接地电阻的误差分析 被引量:11
19
作者 鲁志伟 文习山 《高电压技术》 EI CAS CSCD 北大核心 2002年第7期15-16,21,共3页
针对在双层土壤中采用 5 D— 0 .6 18直线法和 2 D—30°三角法测量变电站接地电阻存在较大误差 ,分析了双层土壤中三角法的布极规律及引起测量误差原因 ,提出了确定补偿点及加长测试极引线等减小误差的措施。
关键词 三角法 测量 双层土壤 接地电阻 误差分析
下载PDF
分层土壤状况下地网接地电阻测量误差分析 被引量:8
20
作者 何宏明 樊灵孟 +3 位作者 钟定珠 陈禾 李谦 彭向阳 《广东电力》 2003年第1期27-32,共6页
分析了理想接地球体状况下,垂直地面方向两层分层和水平方向两层分层的土壤结构对现行规程推荐的0 618法和30°夹角法测量地网接地电阻误差的影响,并对测量引线间互感对测试结果的影响进行了计算分析。
关键词 接地网 分层土壤 接地电阻 测量误差 接地系统
下载PDF