Using a combination of close-range photogrammetry and three-dimensional(3-D) limit equilibrium theory, a determination method for the shear strength parameters of rock-soil mixture is presented. A close-range photogra...Using a combination of close-range photogrammetry and three-dimensional(3-D) limit equilibrium theory, a determination method for the shear strength parameters of rock-soil mixture is presented. A close-range photogrammetry method is used for measurement of the 3-D terrain of the experimental target. Auto CAD Lisp and EXCEL VBA are used to perform 3-D limit equilibrium analysis of the stability of sliding mass and perform backanalysis of shear strength parameters. The presented method was used to determine the shear strength parameters of rock-soil mixtures at the Liyuan Hydropower Station. The 3-D terrain of sliding surface could be measured notably well using of closerange photogrammetry. The computed results reveal that the cohesion and friction angle of rock-soil mixtures were 3.15 k Pa and 29.88o for test A, respectively, and 4.43 k Pa and 28.30o for test B, respectively, within the range of shear strength parameters, as determined by field and laboratory tests. The computation of shear strength parameters is influenced by the mesh grid number, especially the cohesion of the rock-soil mixture. The application of close-range photogrammetry can reduce the siteworks and improve the computational efficiency and accuracy.展开更多
An innovative semisolid technique termed as vibrating cooling slope(VCS)has been applied to producing in-situ Al-25%Mg2Si(mass fraction)composite.The molten Al-16.5Mg-9.4%Si(mass fraction)alloy with 100°C superhe...An innovative semisolid technique termed as vibrating cooling slope(VCS)has been applied to producing in-situ Al-25%Mg2Si(mass fraction)composite.The molten Al-16.5Mg-9.4%Si(mass fraction)alloy with 100°C superheat was poured on the surface of an inclined copper plate(set at 45°inclined angle)while it was vibrated at a frequency of 40 Hz and an amplitude of 400μm.After travelling the length of 40 cm on the slope,the resultant semisolid alloy was cast into a steel mold.For the purpose of comparison,reference composite samples were made by gravity casting(GC)and conventionally still cooling slope casting(CS)methods using the same alloy under identical conditions.The samples were hot extruded at 500°C.It was concluded that the size of Mg2Si particles was decreased by about 50%and 70%for the CS and VCS produced samples respectively when compared to that of the GC produced sample.Despite of their higher porosity contents,both the as-cast and hot-extruded VCS processed samples exhibited higher hardness,shear yield stress(SYS)and ultimate shear strength(USS)values as compared with their GC produced counterparts.These results were attributed to the refined and modified microstructure obtained via this newly developed technique.展开更多
Since the previous strength prediction models for the perfobond rib connector were proposed based upon the results of push-out tests conducted on concretes with compressive strength below 50 MPa, push-out test is perf...Since the previous strength prediction models for the perfobond rib connector were proposed based upon the results of push-out tests conducted on concretes with compressive strength below 50 MPa, push-out test is performed on perfobond shear connectors applying ultra high performance concretes with compressive strength higher than 80 MPa to evaluate their shear resistance. The test variables are chosen to be the diameter and number of dowel holes and, the change in the shear strength of the perfobond rib connector is examined with respect to the strength of two types of UHPC: steel fiber-reinforced concrete with compressive strength of 180 MPa and concrete without steel fiber with compressive strength of 80 MPa. The test results reveal that higher concrete strength and larger number of holes increased the shear strength, and that higher increase rate in the shear strength was achieved by the dowel action. The comparison with the predictions obtained by the previous models shows that the experimental results are close to the values given by the model proposed by Oguejiofor and Hosain [1].展开更多
This work experimentally investigates the effects of shear stud characteristics on the interface slippage of steel-concrete composite push-out specimens. ABAQUS is used to establish a detailed 3D finite element(FE) mo...This work experimentally investigates the effects of shear stud characteristics on the interface slippage of steel-concrete composite push-out specimens. ABAQUS is used to establish a detailed 3D finite element(FE) model and analyze the behavior of push-out specimens. The modeling results are in good agreement with the experimental results. Based on parametrical analysis using the validated FE approaches, the effects of important design parameters, such as the diameter, number, length to diameter ratio, and yield strength of studs, concrete strength and steel transverse reinforcement ratio, on the load-slip relationship at the interface of composite beams are discussed. In addition, a simplified approach to model studs is developed using virtual springs with an equivalent stiffness. This approach is demonstrated to be able to predict the load-displacement response and ultimate bearing capacity of steel-concrete composite beams. The predicted results show satisfactory agreement with experimental results from the literature.展开更多
Steel and ultra⁃high performance concrete(UHPC)composite decks are effective at reducing fatigue cracking and asphalt pavement damage.The shear behavior of innovative open steel tube(OST)connectors in steel⁃UHPC compo...Steel and ultra⁃high performance concrete(UHPC)composite decks are effective at reducing fatigue cracking and asphalt pavement damage.The shear behavior of innovative open steel tube(OST)connectors in steel⁃UHPC composite decks was investigated by conducting push⁃out tests.The test parameter is the presence of reinforcement in the deck.The load⁃slip curves and shear behavior of the push⁃out specimens were obtained and discussed.The test results indicate that as compared with plain concrete specimens,the limit slip of reinforced specimens decreased by 32%and the shear stiffness increased by 10%,but the ultimate shear capacity was almost the same.The use of UHPC influenced the failure process as it was observed that the OST connector was sheared off at its lower semi⁃tube,followed by the pull⁃out failure of the upper semi⁃tube.A finite element model was verified by tests and was then used to analyze the deformation and failure behaviors of the composite deck with open tubes.The model demonstrates that there is a stress concentration zone at the connector root,and the lower semi⁃tube is the main component that is subject to loads.展开更多
A continuous loading push-out test technique was used to measure the interfacial shear strength of SiC fiber reinforced Ti matrix composites. The interfacial shear strength of samples as-fabricated and after heat expo...A continuous loading push-out test technique was used to measure the interfacial shear strength of SiC fiber reinforced Ti matrix composites. The interfacial shear strength of samples as-fabricated and after heat exposed at 700 and 800℃ for 50 h was successfully determined. It has been found that the interfacial shear strength of the specimen exposed at 700℃ was higher than that of as-prepared and exposed samples at 800℃. The shear strength of the as-prepared samples was about 112.45 MPa, and increased to about 153.77 MPa after heat-treating at 700℃ for 50 h, but decreased to 133.11 MPa after treating at 800℃ for 50 h. Scanning electron microscope (SEM) was used to investigate the interfacial morphology of the samples. The brittle phase was the main products of interface for samples exposed at 800℃, and the interface was easily peeled off.展开更多
This paper investigates the design formula for the shear strength at the concrete-to-concrete interface proposed in Eurocode with regard to concrete layers with different strengths. Based upon the results of the study...This paper investigates the design formula for the shear strength at the concrete-to-concrete interface proposed in Eurocode with regard to concrete layers with different strengths. Based upon the results of the study on the applicability of the design formula, push-off test is conducted on specimens with various indented interfaces to evaluate the actual behavior with respect to the surface roughness. The experimental results reveal that the interfacial shear strength increases with higher compressive strength of the concrete layers presenting different strengths and that the shear strength at the indented interface differs by 20% to 50% compared to the value predicted by the design formula. Especially, the shear strength developed between the concrete layers with different strengths appears to be different from the prediction of the design formula as much as the layers present larger difference in their compressive strengths.展开更多
Columnar jointed basalt(CJB) widely distributes in the dam site of the Baihetan Hydropower Station.The columnar joint structure and fracture development of CJB have significant influence on the mechanical properties o...Columnar jointed basalt(CJB) widely distributes in the dam site of the Baihetan Hydropower Station.The columnar joint structure and fracture development of CJB have significant influence on the mechanical properties of rock mass,and the mechanical properties of CJB are of great significance to the Baihetan Hydropower Project.Therefore,in-situ direct shear tests were carried out on ten test adit at different locations in the dam site area to study the shear behavior of CJB.In this study,21 sets of in-situ direct shear tests were conducted for rock types of type Ⅱ_(2),type Ⅲ_(1)and type Ⅲ_(2),with horizontal and vertical shear planes and two different specimen sizes of CJB.Shear strength parameters of CJB were obtained by linear fitting of in-situ direct shear test results based on the Mohr-Coulomb strength criterion.The results indicate that the shear strength parameters of CJB with horizontal shear plane increase as the increase of rock type grade.The shear strength parameters of CJB show obvious anisotropy and the friction coefficient of the horizontal shear plane is greater than the vertical shear plane.The friction coefficient in the horizontal direction of the shear plane is 1.27 times that in the vertical direction of the shear plane.With the increase of rock type grade,the difference of friction coefficient becomes larger.However,the cohesion changes little whether the shear plane is horizontal or vertical.In addition,the size effect of CJB in this area is significant.The shear strength parameters of large size(100 cm × 100 cm) specimens are lower than those of regular size(50 cm × 50 cm) specimens.The reduction of cohesion is greater than that of the friction coefficient.For rock type Ⅲ_(2),the cohesion of large-size specimens is 0.637 of the regular-size specimens.The reduction percentage of the friction coefficient for type Ⅲ_(2)is 1.66 times that of type Ⅲ_(1).The reduction percentage of the cohesion for type Ⅲ_(2)is 1.27 times that of type Ⅲ_(1).The size effect decreases with the increase of rock type grade.The research results of this study can provide an important basis for the selection of rock mechanics parameters in the dam site area of Baihetan Hydropower Station and the stability analysis of the dam foundation and rocky slopes.展开更多
基金the support of the National Natural Science Foundation of China (Grant Nos. 41472272, 41102194)the Key Deployment Project of the Chinese Academy of Sciences (KZZD-EW-05-01)the Science Foundation for Excellent Youth Scholars of Sichuan University (2013SCU04A07)
文摘Using a combination of close-range photogrammetry and three-dimensional(3-D) limit equilibrium theory, a determination method for the shear strength parameters of rock-soil mixture is presented. A close-range photogrammetry method is used for measurement of the 3-D terrain of the experimental target. Auto CAD Lisp and EXCEL VBA are used to perform 3-D limit equilibrium analysis of the stability of sliding mass and perform backanalysis of shear strength parameters. The presented method was used to determine the shear strength parameters of rock-soil mixtures at the Liyuan Hydropower Station. The 3-D terrain of sliding surface could be measured notably well using of closerange photogrammetry. The computed results reveal that the cohesion and friction angle of rock-soil mixtures were 3.15 k Pa and 29.88o for test A, respectively, and 4.43 k Pa and 28.30o for test B, respectively, within the range of shear strength parameters, as determined by field and laboratory tests. The computation of shear strength parameters is influenced by the mesh grid number, especially the cohesion of the rock-soil mixture. The application of close-range photogrammetry can reduce the siteworks and improve the computational efficiency and accuracy.
文摘An innovative semisolid technique termed as vibrating cooling slope(VCS)has been applied to producing in-situ Al-25%Mg2Si(mass fraction)composite.The molten Al-16.5Mg-9.4%Si(mass fraction)alloy with 100°C superheat was poured on the surface of an inclined copper plate(set at 45°inclined angle)while it was vibrated at a frequency of 40 Hz and an amplitude of 400μm.After travelling the length of 40 cm on the slope,the resultant semisolid alloy was cast into a steel mold.For the purpose of comparison,reference composite samples were made by gravity casting(GC)and conventionally still cooling slope casting(CS)methods using the same alloy under identical conditions.The samples were hot extruded at 500°C.It was concluded that the size of Mg2Si particles was decreased by about 50%and 70%for the CS and VCS produced samples respectively when compared to that of the GC produced sample.Despite of their higher porosity contents,both the as-cast and hot-extruded VCS processed samples exhibited higher hardness,shear yield stress(SYS)and ultimate shear strength(USS)values as compared with their GC produced counterparts.These results were attributed to the refined and modified microstructure obtained via this newly developed technique.
文摘Since the previous strength prediction models for the perfobond rib connector were proposed based upon the results of push-out tests conducted on concretes with compressive strength below 50 MPa, push-out test is performed on perfobond shear connectors applying ultra high performance concretes with compressive strength higher than 80 MPa to evaluate their shear resistance. The test variables are chosen to be the diameter and number of dowel holes and, the change in the shear strength of the perfobond rib connector is examined with respect to the strength of two types of UHPC: steel fiber-reinforced concrete with compressive strength of 180 MPa and concrete without steel fiber with compressive strength of 80 MPa. The test results reveal that higher concrete strength and larger number of holes increased the shear strength, and that higher increase rate in the shear strength was achieved by the dowel action. The comparison with the predictions obtained by the previous models shows that the experimental results are close to the values given by the model proposed by Oguejiofor and Hosain [1].
基金Project(2011BAJ09B02)supported by the National Key Technology R&D Program,ChinaProjects(51578548,51378511,51678576)supported by the National Natural Science Foundation of China
文摘This work experimentally investigates the effects of shear stud characteristics on the interface slippage of steel-concrete composite push-out specimens. ABAQUS is used to establish a detailed 3D finite element(FE) model and analyze the behavior of push-out specimens. The modeling results are in good agreement with the experimental results. Based on parametrical analysis using the validated FE approaches, the effects of important design parameters, such as the diameter, number, length to diameter ratio, and yield strength of studs, concrete strength and steel transverse reinforcement ratio, on the load-slip relationship at the interface of composite beams are discussed. In addition, a simplified approach to model studs is developed using virtual springs with an equivalent stiffness. This approach is demonstrated to be able to predict the load-displacement response and ultimate bearing capacity of steel-concrete composite beams. The predicted results show satisfactory agreement with experimental results from the literature.
基金Sponsored by the National Natural Science Foundation of China(Grant No.51478120)。
文摘Steel and ultra⁃high performance concrete(UHPC)composite decks are effective at reducing fatigue cracking and asphalt pavement damage.The shear behavior of innovative open steel tube(OST)connectors in steel⁃UHPC composite decks was investigated by conducting push⁃out tests.The test parameter is the presence of reinforcement in the deck.The load⁃slip curves and shear behavior of the push⁃out specimens were obtained and discussed.The test results indicate that as compared with plain concrete specimens,the limit slip of reinforced specimens decreased by 32%and the shear stiffness increased by 10%,but the ultimate shear capacity was almost the same.The use of UHPC influenced the failure process as it was observed that the OST connector was sheared off at its lower semi⁃tube,followed by the pull⁃out failure of the upper semi⁃tube.A finite element model was verified by tests and was then used to analyze the deformation and failure behaviors of the composite deck with open tubes.The model demonstrates that there is a stress concentration zone at the connector root,and the lower semi⁃tube is the main component that is subject to loads.
文摘A continuous loading push-out test technique was used to measure the interfacial shear strength of SiC fiber reinforced Ti matrix composites. The interfacial shear strength of samples as-fabricated and after heat exposed at 700 and 800℃ for 50 h was successfully determined. It has been found that the interfacial shear strength of the specimen exposed at 700℃ was higher than that of as-prepared and exposed samples at 800℃. The shear strength of the as-prepared samples was about 112.45 MPa, and increased to about 153.77 MPa after heat-treating at 700℃ for 50 h, but decreased to 133.11 MPa after treating at 800℃ for 50 h. Scanning electron microscope (SEM) was used to investigate the interfacial morphology of the samples. The brittle phase was the main products of interface for samples exposed at 800℃, and the interface was easily peeled off.
文摘This paper investigates the design formula for the shear strength at the concrete-to-concrete interface proposed in Eurocode with regard to concrete layers with different strengths. Based upon the results of the study on the applicability of the design formula, push-off test is conducted on specimens with various indented interfaces to evaluate the actual behavior with respect to the surface roughness. The experimental results reveal that the interfacial shear strength increases with higher compressive strength of the concrete layers presenting different strengths and that the shear strength at the indented interface differs by 20% to 50% compared to the value predicted by the design formula. Especially, the shear strength developed between the concrete layers with different strengths appears to be different from the prediction of the design formula as much as the layers present larger difference in their compressive strengths.
基金supported by the National Key Research and Development Program of China (No.2017YFC1501302)the National Natural Science Foundation of China (No.41630643)+1 种基金the Fundamental Research Funds for the Central Universities (No.CUGCJ1701)the Scientific research project of China Three Gorges Corporation Ltd。
文摘Columnar jointed basalt(CJB) widely distributes in the dam site of the Baihetan Hydropower Station.The columnar joint structure and fracture development of CJB have significant influence on the mechanical properties of rock mass,and the mechanical properties of CJB are of great significance to the Baihetan Hydropower Project.Therefore,in-situ direct shear tests were carried out on ten test adit at different locations in the dam site area to study the shear behavior of CJB.In this study,21 sets of in-situ direct shear tests were conducted for rock types of type Ⅱ_(2),type Ⅲ_(1)and type Ⅲ_(2),with horizontal and vertical shear planes and two different specimen sizes of CJB.Shear strength parameters of CJB were obtained by linear fitting of in-situ direct shear test results based on the Mohr-Coulomb strength criterion.The results indicate that the shear strength parameters of CJB with horizontal shear plane increase as the increase of rock type grade.The shear strength parameters of CJB show obvious anisotropy and the friction coefficient of the horizontal shear plane is greater than the vertical shear plane.The friction coefficient in the horizontal direction of the shear plane is 1.27 times that in the vertical direction of the shear plane.With the increase of rock type grade,the difference of friction coefficient becomes larger.However,the cohesion changes little whether the shear plane is horizontal or vertical.In addition,the size effect of CJB in this area is significant.The shear strength parameters of large size(100 cm × 100 cm) specimens are lower than those of regular size(50 cm × 50 cm) specimens.The reduction of cohesion is greater than that of the friction coefficient.For rock type Ⅲ_(2),the cohesion of large-size specimens is 0.637 of the regular-size specimens.The reduction percentage of the friction coefficient for type Ⅲ_(2)is 1.66 times that of type Ⅲ_(1).The reduction percentage of the cohesion for type Ⅲ_(2)is 1.27 times that of type Ⅲ_(1).The size effect decreases with the increase of rock type grade.The research results of this study can provide an important basis for the selection of rock mechanics parameters in the dam site area of Baihetan Hydropower Station and the stability analysis of the dam foundation and rocky slopes.